Dynamic characteristic for vibration mount of MG-Set (전동-발전기의 방진 마운트에 기인한 공진현상 및 동특성 규명)

  • Yoo, Musang;Oh, Kyonghan;Joo, Ingouk;Kim, Hyojin;Roh, Cheolwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.816-821
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of generator-motor set. The generator is driven at 1800rpm by induction integral motor. The vibration is below alarm limits, but the dominant frequency of vibration is sub-synchronous and close to that of bearing fault signal in spite of new bearings. To find an mechanism of abnormal vibration, ODS and Modal analysis is carried out. The measured modal characteristics were compared with those of FE Analysis. The ODS mode at rated speed is consistent with system natural frequency mode that is excited by bearings. To reduce vibration level, the isolation mount at system base is changed with new rubber mount for lower natural frequency.

  • PDF

Development of Vibration Diagnosis System for Rotating Machine (회전기계의 이상진동진단 시스템의 개발)

  • 양보석;장우교;김호종
    • Journal of KSNVE
    • /
    • v.6 no.3
    • /
    • pp.325-332
    • /
    • 1996
  • One of the greatest shortcoming in today's predictive maintenance program is the ability to diagnose the mechanical and electrical problems within the machine when the vibration exceeds preset overall and spectral alarm levels. In this study, auto-diagnosis system is constructed by using A/D converter to convert analog to digital singal. With this device the system analyses input signal to diagonosis machine condition. Many plots, which display machine condition, and input values of every channel are calculated in this system. If the falut is found, the system diagnoses automatically using fuzzy algorithm and trend monitoring. Prediction is also performed by the grey system theory. Operator finds out eh machine operating condition intuitively based on with personal computer CRT in using this system.

  • PDF

Vibration Characteristics of a Synchro Clutch Coupling for Steam Turbine (증기터빈용 Synchro Clutch Coupling의 진동 특성)

  • Shim, Eung-Gu;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.66-72
    • /
    • 2008
  • The vibration of steam turbine is caused by Mass unbalance, Shaft misalignment, Oil whip and rubbing etc. But in turbine which is normally operated and maintained, the Mass unbalance component possesses the greatest portion. Our power plant has two steam turbines in capacity of 200 MW and 135 MW respectively and each turbine is supported by 6 journal bearings. However, we had many difficulties because the vibration amplitude of #3 and #4 Bearings was high during the start-up and operation mode change of steam turbine. But, with this study, we completely solved the vibration problem caused by the mass unbalance of #1 steam turbine. Until a recent date, #3 and #4 bearings which support high pressure turbine for #1 steam turbine had shown about $135{\mu}m$ in vibration amplitude (sometimes it increased to $221{\mu}m$ maximum. alarm: 6 mils, trip: 9 mils) at base load. After applying the study, they decreased to about $45{\mu}m$ maximum. It is a result from that we did not change the setting value of bearing alignment and only changed the assembly position of internal parts in Synchro clutch coupling rachet wheel which links between high pressure turbine and low pressure turbine, and increased the internal gap and machining of the Pawl cage surface. In the operation of steam turbine, if the vibration value increases by 1X, we should reduce the vibration of bearing by weight balancing. However, unless the vibration of bearing is declined by the balancing, we will have to disassemble and check the component and find the cause. In this study, we researched the way to lower mass unbalance that is 1X vibration component which has the greatest portion of vibration generated by steam turbine and we got good result by applying the findings of this study.

  • PDF

A study on Mass Unbalance Vibration Generated from 200MW Steam Turbine Synchro Clutch Coupling (증기터빈용 Synchro Clutch Coupling에서 발생하는 진동에 관한 연구)

  • Shim, Eung-Gu;Kim, Young-Kyun;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.232-235
    • /
    • 2008
  • The vibration of steam turbine is caused by Mass Unbalance, Shaft Misalignment, Oil Whip and Rubbing etc. but in turbine which is normally operated and maintained, the Mass Unbalance component possesses the greatest portion. Our power plant has two steam turbines in capacity of 200MW and 135MW respectively and each turbine is supported by 6 journal bearings. However, we had many difficulties because the vibration amplitude of No 3 and 4 Bearings was high during the start-up and operation mode change of steam turbine. But, with this study, we completely solved the vibration problem caused by the mass unbalance of No 1 steam turbine. Until a recent date, No 3 and 4 bearings which support high pressure turbine for No 1 steam turbine had shown about 135${\mu}$m in vibration amplitude (sometimes it increased to 221${\mu}$m maximum. alarm: 6mils, trip: 9mils) at base load. After applying the study, they decreased to about 40${\mu}$m maximum. It is a result from that we did not change the setting value of Bearing Alignment and only changed the assembly position of internal parts in Synchro Clutch Coupling Rachet Wheel which links between high pressure turbine and low pressure turbine, and increased the internal gap and machining of the Pawl stopper surface. In the operation of steam turbine, if the vibration value increases by 1X, we should reduce the vibration of bearing by weight balancing. However, unless the vibration of bearing is declined by the balancing, we will have to disassemble and check the component and find the cause. In this study, We researched the way to lower mass unbalance that is 1X vibration component which has the greatest portion of vibration generated by steam turbine and We got good result by applying the findings of this study.

  • PDF

Vibration-Based Damage Monitoring in Model Plate-Girder Bridges under Uncertain Temperature Conditions (불확실한 온도 조건하의 모형 강 판형교의 진동기반 손상 모니터링)

  • Park, Jae-Hyung;Hong, Dong-Soo;Cho, Hyun-Man;Kim, Jeong-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.75-82
    • /
    • 2008
  • A vibration-based damage-monitoring scheme is proposed that would generate an alarm showing the occurrence and location of damage under temperature-induced uncertainty conditions. Experiments on a model plate-girder bridge are described, for which a set of modal parameters was measured under uncertain temperature conditions. A damage-alarming model is formulated to statistically identify the occurrence of damage by recognizing the patterns of damage-driven changes in the natural frequencies of the test structure and by distinguishing temperature-induced off-limits. A damage index method based on the concept of modal strain energy is implemented in the test structure to predict the location of damage. In order to adjust for the temperature-induced changes in the natural frequencies that are used for damage detection, a set of empirical frequency correction formulas is analyzed from the relationship between the temperature and frequency ratio.

A Fuzzy Expert System Based on Hybrid Database for Fault Diagnosis of Industrial Turbomachinery (산업용 터보기기 결함 진단을 위한 복합적 데이터베이스 구조의 퍼지 전문가 시스템)

  • 백두진;김승종;김창호;장건희;이용복
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.703-712
    • /
    • 2003
  • This paper suggests a fuzzy expert system for fault diagnosis of rotating machinery, based on modulated databases. In the proposed system, alarm and trip levels are set based on ISO, considering operating condition, machinery type and maintenance history. Input signals for diagnosis, such as sub-and super-harmonic components of vibration and mean value, are normalized from 0 to 1 under the threshold level and otherwise equal to one so that chronic faults slightly below the threshold level can be monitored. The database for diagnosis consists of two modules: the well-known Sohre's chart module and if-then type rules. The Sohre's chart is utilized for the most common problems of high-speed turbomachinery, while the rule-based module, which was collected from many papers and reports, is for diagnosing peculiar faults according to the type of machinery. To infer the results from two modules, a fuzzy operation of Yager sum was adopted. Using a simulator constructed in laboratory, experimental verification was performed for the cases of unbalance and resonance which were intended. The experimental results show that the proposed fuzzy expert system has feasibility in practical diagnosis of rotating machinery.

A Hybrid Fuzzy Expert System Based on Module-type Database for Fault Diagnosis of Turbomachinery (모듈 구조 데이터베이스 기반의 터보기기 결함 진단용 하이브리드 퍼지 전문가 시스템)

  • 백두진;김승종;김창호;곽현덕;장건희;이용복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.303-312
    • /
    • 2003
  • This paper suggests a fuzzy expert system for fault diagnosis of rotating machinery, based on modulated databases. In the proposed system, alarm and trip levels are set based on ISO, considering operating condition, machinery type and maintenance history. Input signals for diagnosis, such as sub- and super-harmonic components of vibration and mean value, are normalized from 0 to 1 under the threshold level and otherwise equal to one so that chronic faults slightly below the threshold level can be monitored. The database for diagnosis consists of two modules: the well-known Sohre's chart module and if-then type rules. The Sohre's chart is utilized for the most common problems of high-speed turbomachinery, while the rule-based module, which was collected from many papers and reports, is for diagnosing peculiar faults according to the type of machinery. To infer the results from two modules, a fuzzy operation of Yager sum was adopted. Using a simulator constructed in laboratory, experimental verification was performed for the cases of resonance and housing looseness which were intended. The experimental results show that the proposed fuzzy expert system has feasibility in practical diagnosis of rotating machinery.

  • PDF

Development of Diagnosis System for LNG Pump (LNG 펌프 고장 진단 시스템 개발)

  • Hong S. H.;Lee Y. W.;Hwang W G.;Ki Ch. D.;Kim Y. B.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.3
    • /
    • pp.88-95
    • /
    • 1998
  • Vibration analysis of rotating machinery can give an indication of possible faults thus allowing maintenance before further damage occurs. Current predictive maintenance system installed in Pyung-tak has the ability to diagnose the mechanical problems within the LNG Pump when the vibration exceeds preset overall alarm levels. In this study, LNG pump auto-diagnosis system based upon Windows NT and DSP Board is developed. This system analysis velocity signal acquired from dual accelerometer input monitor system to diagnose pump condition. Many plots which display machine condition are shown and features of vibration are stored in every time. If the fault is found, the system diagnoses automatically using expert system and trend monitoring. Operator checks pump condition intuitively using personal computer monitor.

  • PDF

Hybrid Damage Monitoring Technique for Plate Girder Bridges using Acceleration-Impedance Signatures (판형교의 가속도-임피던스 신호를 이용한 하이브리드 손상 모니터링 기법)

  • Hong, Dong-Soo;Cho, Hyun-Man;Na, Won-Bae;Kim, Jeong-Tae;Park, Gyu-Hae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.197-202
    • /
    • 2008
  • In this paper, a hybrid vibration-impedance approaches is newly proposed to detect the occurrence of damage, the location of damage, and extent of damage in steel plate-girder bridges. The hybrid scheme mainly consists of three sequential phases: 1) to alarm the occurrence of damage, 2) to classify the alarmed damage, and 3) to estimate the classified damage in detail. Damage types of interest include flexural stiffness-loss in girder and bolts-loose in supports. In the first phase, the global occurrence of damage is alarmed by monitoring changes in acceleration features. In the second phase, the alarmed damage is classified into subsystems by recognizing patterns of impedance features. In the final phase, the location and the extent of damage are estimated by using modal strain energy-based damage index method and root mean square deviation method. The feasibility of the proposed system is evaluated on a laboratory-scaled steel plate-girder bridge model for which hybrid vibration-impedance signatures were measured for several damage scenarios.

  • PDF

Subjective Responses for the Fire Signal Sound of Acoustic Reporting Equipment Depending on Visual Information (시각정보 변화에 따른 음향통보장치 신호음의 청감반응)

  • Song, Hyuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.313-319
    • /
    • 2005
  • Instruction and prevention of the safety for a fire have been performed continuously by nation. However, the accident due to a fire is not decreasing and causes a serious calamity to people. It is at the initial stage of fire burning that the most effective way to reduce damage is to evacuate and fight a fire. When a fire burns, the equipments reporting to other person or organization concerned are called 'acoustic reporting equipment'. Among those equipments reporting to person, 'a fire bell' is the easiest equipment to approach. Observing the behaviors of people when a fire burning, some are in a quiet indoor, some in a room with other people, some in a square with many people and some in indoor filled with smoke etc. This study aims to find out an acoustic reporting signal appropriate for visual information. For the experiments, visual-auditory experiments were performed through reporting signals and visual informations with several situations that is able to be faced at when a fire burns.