• Title/Summary/Keyword: Via-Filling

Search Result 149, Processing Time 0.027 seconds

Dynamic Characteristics of Liquidity Filling Materials Mixed with Reclaimed Ash (매립석탄회를 혼합한 유동성 충진재의 동적거동특성)

  • Chae, Deokho;Kim, Kyoungo;Shin, Hyunyoung;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.4
    • /
    • pp.5-11
    • /
    • 2014
  • Recently, there have been various lifeline installations constructed in the underground space of urban area due to the effective use of land. For newly installed lifelines or the management of the installed lifelines, many construction activities of excavation and backfilling are observed. Around these area, there are possibilities of collapse or excessive settlement due to the leaking of the pipe or unsatisfactory compaction of backfill material. Besides, construction costs can be saved since the on-site soils are used. The application of this liquidity filling material is not only to the lifeline installation but also to underpin the foundation under the vibrating machinery. On the evaluation of the applicability of this method to this circumstance, the strength should be investigated against the static load from the machine load as well as the vibration load from the activation of the machine. In this study, the applicability of the liquidity fill material on the foundation under the vibrating machinery is assessed via uniaxial compression and resonant column tests. The liquidity filling material consisting of the on-site soils with loess and kaolinite are tested to investigate the static and dynamic characteristics. Furthermore, the applicability of the reclaimed ash categorized as an industrial waste is evaluated for the recycle of the waste to the construction materials. The experimental results show that the shear modulus and 7 day uniaxial strength of the liquidity filling material mixed with reclaimed ash show higher than those with the on-site soils. However, the damping ratio does not show any tendency on the mixed materials.

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF

Design of US PCS Duplexer for wireless systems (무선 시스템용 US PCS FBAR Duplexer 설계)

  • Lee, Eun-Kyu;Choi, Hyung-Rim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.210-211
    • /
    • 2009
  • In this study, we propose characteristics improvement methods according to via hole plating method for FBAR Duplexer with US PCS($T_x$:1850MHz~1910MHz, $R_x$:1930MHz~1990MHz) bandwidth which is used for wireless systems. Also, we designed and fabricated 3.8*3.8*1.8mm size microminiature FBAR Duplexer based on this proposal. First of all, in this study, we fabricated pentagon shape resonators by different size to make filter combination, and their quality factor(Q) are 687 with 6.6% of $k_{eff}^2$. Using this resonators, designed 3*2Type $T_x$ filter and 3*4Type $R_x$ filter. The transmission line, which works as phase shifter, is designed with $210{\mu}m$ in width and 18mm in length Stripline type. Inductor, which is used for matching component, is designed with width of $75{\mu}m$, a technically achievable minimum width. And adopted plating method of filling via hole with conductive epoxy for improved grounding and thermal conductivity. Using these configuration with all of the matching component values, we found Duplexer characteristics of -1.57dB ~ -1.73dB in insertion loss, -56dB in attenuation at 1850MHz~1910MHz of $T_x$ band. Also, found -2.71 dB ~ -3.23dB in insertion loss, -58dB in attenuation at 1930MHz~1990MHz of $R_x$ band.

  • PDF

펄스전해증착에서 첨가제가 나노쌍정구리의 형성에 미치는 영향

  • Seo, Seong-Ho;Jin, Sang-Hyeon;Choe, Jae-Wan;Park, Jae-U;Yu, Bong-Yeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.38.2-38.2
    • /
    • 2011
  • 구리는 현재 반도체 배선으로 가장 많이 사용되는 재료이다. 배선기술이 발전함에 따라 배선두께가 얇아지게 되었고 배선간의 간격 또한 좁아지게 되었다. 간격의 감소는 RC delay 문제점을 야기하였고 이를 해결하기 위해 배선 사이에 Low-k물질을 채우는 노력이 지속되었다. 이상적으로 가장 낮은 유전율을 나타내는 물질은 공기 즉, 아무것도 채우지 않는 것이다. 하지만 이렇게 되면 기계적인 문제가 발생하는데 이를 해결하기 위해서 구리의 강도를 향상시켜야 한다. 강도를 높이려면 Hall-Petch 관계에 의해 결정립의 크기를 작게 만들어야 한다. 그렇지만 이는 곧 전기전도도의 감소를 나타내기 때문에 소자의 구동에 문제가 되어왔다. 이 문제를 해결하기 위해 펄스전해증착을 통한 나노사이즈의 쌍정구조를 가지는 구리의 개발이 진행되었다. 나노쌍정구리는 결정립이 정합면으로 이루어져 있는 쌍정구조로 이루어져 있어 전기전도도의 감소를 최소화하고 강도를 비약적으로 향상시킬 수 있을뿐더러 연신율도 높일 수 있다는 장점을 가지고 있다. 이렇게 고강도 저저항을 나타내는 나노쌍정구리는 Via filling, Through Silicon Via(TSV)에서의 칩간 연결 배선, 2차전지의 전극 등에 적용 가능성이 매우 높다. 이들은 주로 첨가제와 함께 전해증착을 통해 제작된다. 하지만 이러한 첨가제를 넣고 나노쌍정구리를 합성하기 위해 펄스전해증착을 시행할 경우, 나노 쌍정구리의 형성이 억제되고, Off-time이 존재하지 않는 일반 전해증착에서와는 다른 현상이 나타나게 된다. 이러한 이유로 본 연구에서는 현재 가장 많이 사용되고 있는 첨가제인 Poly (ethylene glycol) (PEG, 억제제)와 bis (3-sulfopropyl) disulfide (SPS, 가속제)을 사용하여 그 이유를 알아보고 첨가제를 사용하면서 나노쌍정구리의 밀도를 높일 수 있는 방안에 대해서 실험을 진행하였다.

  • PDF

A Study on Improvement of FBAR Duplexer for Wireless Systems (무선 시스템용 FBAR 듀플렉서 특성 개선 연구)

  • Lee, Eun-Kyu;Choi, Hyung-Rim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.388-396
    • /
    • 2010
  • In this study, we propose characteristics improvement methods according to via hole plating method for FBAR Duplexer with bandwidth($T_x4: 1850 MHz ~ 1910 MHz, $R_x$:1930 MHz ~ 1990 MHz) which is used for wireless systems. Also, we designed and fabricated $3.8{\times}3.8{\times}1.8mm$ size microminiature FBAR Duplexer based on this proposal. First of all, in this study, we fabricated pentagon shape resonators by different size to make filter combination, and their quality factor(Q) are 687 with 6.6% of ${k_{eff}}^2$. Using this resonators, we designed $3{\times}2$ Type $T_x$ filter and $3{\times}4$ Type $R_x$ filter. The transmission line, which works as phase shifter, is designed with 210 ${\mu}m$ in width and 18 mm in length Stripline type. Inductor, which is used for matching component, is designed with width of 75 ${\mu}m$, a technically achievable minimum width. And adopted plating method of filling via hole with conductive epoxy for improved grounding and thermal conductivity. Using these configuration with all of the matching component values, we found Duplexer characteristics of -1.57 dB ~ -1.73 dB in insertion loss, -56 dB in attenuation at 1850 MHz ~ 1910 MHz of $T_x$ band. Also, found -2.71 dB ~ -3.23 dB in insertion loss, -58 dB in attenuation at 1930 MHz ~ 1990 MHz of $R_x$ band.

A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

  • Bae, Seong Hwan;Jeong, Dae Kyun;Go, Ju Young;Park, Heeseung;Kim, Joo Hyoung;Lee, Jae Woo;Kang, Taewoo
    • Archives of Plastic Surgery
    • /
    • v.46 no.5
    • /
    • pp.421-425
    • /
    • 2019
  • Background The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. Methods Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. Results Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. Conclusions We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.

Adhesion and Diffusion Barrier Properties of $TaN_x$ Films between Cu and $SiO_2$ (Cu 박막과 $SiO_2$ 절연막사이의 $TaN_x$ 박막의 접착 및 확산방지 특성)

  • Kim, Yong-Chul;Lee, Do-Seon;Lee, Won-Jong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.19-24
    • /
    • 2009
  • Formation of an adhesion/barrier layer and a seed layer by sputtering techniques followed by electroplating has been one of the most widely used methods for the filling of through-Si via (TSV) with high aspect ratio for 3-D packaging. In this research, the adhesion and diffusion-barrier properties of the $TaN_x$ film deposited by reactive sputtering were investigated. The adhesion strength between Cu film and $SiO_2$/Si substrate was quantitatively measured by $180^{\circ}$ peel test and topple test as a function of the composition of the adhesive $TaN_x$ film. As the nitrogen content increased in the adhesive $TaN_x$ film, the adhesion strength between Cu and $SiO_2$/Si substrate increased, which was attributed to the increased formation of interfacial compound layer with the nitrogen flow rate. We also examined the diffusion-barrier properties of the $TaN_x$ films against Cu diffusion and found that it was improved with increasing nitrogen content in the $TaN_x$ film up to N/Ta ratio of 1.4.

  • PDF

A Study on Stress, Hardiness, and Self-care in Kidney Transplant Patients (신장이식환자의 스트레스, 강인성, 자가간호에 대한 연구)

  • Bae, Go Oon;Lee, Young Whee;Kim, Wha Soon;Im, Ji Young
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.1
    • /
    • pp.136-145
    • /
    • 2006
  • Purpose: This study was performed to identify relationships among stress, hardiness, and the level of self-care in kidney transplant patients and use the results of this study as baseline data for developing self-care promotion programs. Method: Subjects were 41 patients who undergone a kidney transplantation surgery at least one month before and were receiving regular follow-up care via OPD. Four researchers interviewed each subjects by filling out questionnaires. Results: The mean score of the level of stress was 2.32(SD=0.54) on a 4 point scale and the mean score of hardiness was 4.68(SD=0.62) on a 6 point scale. The mean score of self-care among the subjects was 3.83(SD=0.55). There was statistically a significant positive relationship between selfcare and hardiness(r=0.42). Especially, relationships between self-care and commitment (r=.51) and control(r=.36) as the subdimensions of hardiness were significant. The item suggested as most stressful was economic burden and the item suggested as least stressful was sexual activity. Conclusion: Although transplant patients have various stressors, the positive self-care activities of the patients could be increased if the commitment and control were enhanced by proper intervention programs.

  • PDF

EXPERIMENTAL STUDY ON MEASUREMENT OF EMISSIVITY FOR ANALYSIS OF SNU-RCCS

  • CHO YUN-JE;KIM MOON OH;PARK GOON-CHERL
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.99-108
    • /
    • 2006
  • SNU-RCCS is a water pool type RCCS (Reactor Cavity Cooling System) developed for VHTR (Very High Temperature Reactor) application by SNU (Seoul National University). Since radiation heat transfer is the major process of passive heat removal in a RCCS, it is important to determine the precise emissivity of the reactor vessel. Review studies have used a constant emissivity in the passive heat removal analysis, even though the emissivity depends on many factors such as temperature, surface roughness, oxidation level, wavelength, direction, atmosphere conditions, etc. Therefore, information on the emissivity of a given material in a real RCCS is essential in order to properly analyze the radiation heat transfer in a VHTR. The objectives of this study are to develop a method for compensation of the factors affecting the emissivity measurement using an infrared thermometer and to estimate the true emissivity from the measured emissivity via the developed method, especially in the SNU-RCCS environment. From this viewpoint, we investigated factors such as the attenuation effect of the window, filling gas, and the effect of background radiation on the emissivity measurements. The emissivity of the vessel surface of the SNU-RCCS facility was then measured using a sight tube. The background radiation was subsequently removed from the measured emissivity by solving a simultaneous equation. Finally, the calculated emissivity was compared with the measured emissivity in a separate emissivity measurement device, yielding good agreement with the emissivity increase with vessel temperature in a range of 0.82 to 0.88.

Retroperitoneal Hematoma as a Serious Complication of Endovascular Aneurysmal Coiling

  • Murai, Yasuo;Adachi, Koji;Yoshida, Yoichi;Takei, Mao;Teramoto, Akira
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.88-90
    • /
    • 2010
  • Retroperitoneal hematoma (RH) due to radiologic intervention for an intracranial lesion is relatively rare, difficult to diagnose, and can be lifethreatening. We report a case of RH that developed in a patient on anticoagulant therapy following endovascular coiling of a ruptured anterior communicating artery (AcoA) aneurysm. An 82-year-old man presented with a 12-day history of headache. Computed tomography (CT) on admission demonstrated slight subarachnoid hemorrhage, and left carotid angiography revealed an AcoA aneurysm. The next day, the aneurysm was occluded with coils via the femoral approach under general anesthesia. The patient received a bolus of 5,000 units of heparin immediately following the procedure, and an infusion rate of 10,000 units/day was initiated. The patient gradually became hypotensive 25 hours after coiling. Abdominal CT showed a huge, high-density soft-tissue mass filling the right side of the retroperitoneum space. The patient eventually died of multiple organ failure five days after coiling. RH after interventional radiology for neurological disease is relatively rare and can be difficult to diagnose if consciousness is disturbed. This case demonstrates the importance of performing routine physical examinations, sequentially measuring the hematocrit and closely monitoring systemic blood pressures following interventional radiologic procedures in patients with abnormal mental status.