• 제목/요약/키워드: Vi Sensor

검색결과 29건 처리시간 0.022초

Nano Structured Potentiometric Sensors Based on Polyaniline Conducting Polymer for Determination of Cr (VI)

  • Ali, Mohammad-Khah;Ansari, Reza;Delavar, Ali Fallah;Mosayebzadeh, Zahra
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권4호
    • /
    • pp.1247-1252
    • /
    • 2012
  • In this paper, a potentiometric sensor based on polyaniline conducting polymer for potentiometric determination of Cr (VI) ions is reported. Polyaniline was synthesized electrochemically (cyclic voltammetry method) onto a micro pencil graphite electrode (0.7 mm diameter) in the presence of HCl and diphenylcarbazide (termed as (PGE/PAni/DPC). Some initial experiments were performed in order to find out the optimized conditions for preparation of the introduced Cr (VI) sensor electrode. The plot of E vs. log [Cr (VI)], showed a linear response in the range from $1.0{\times}10^{-6}$ to $1.0{\times}10^{-1}$ M. High repeatability with the detection limit of $8.0{\times}10^{-7}$ M was obtained.

A STUDY ON INTER-RELATIONSHIP OF VEGETATION INDICES USING IKONOS AND LANDSAT-7 ETM+ IMAGERY

  • Yun, Young-Bo;Lee, Sung-Hun;Cho, Seong-Ik;Cho, Woo-Sug
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.852-855
    • /
    • 2006
  • There is an increasing need to use data from different sensors in order to maximize the chances of obtaining a cloud-free image and to meet timely requirements for information. However, the use of data from multiple sensor systems is depending on comprehensive relationships between sensors of different types. Indeed, a study of inter-sensor relationships is well advanced in the effective use of remotely sensed data from multiple sensors. This paper was concerned with relationships between sensors of different types for vegetation indices (VI). The study was conducted using IKONOS and Landsat-7 ETM+ images. IKONOS and Landsat-7 ETM+ image of the same or about the same dates were acquired. The Landsat-7 ETM+ images were resampled in order to make them coincide with the pixel sizes of IKONOS. Inter-relationships of vegetation indices between images were performed using at-satellite reflectance obtained by converting image digital number (DN). All images were applied to topographic normalization method in order to reduce topographic effect in digital imagery. Also, Inter-sensor model equations between two sensors were developed and applied to other study region. In the result, the relational equations can be used to compute or interpret VI of one sensor using the VI of another sensor.

  • PDF

가스 유량 변화에 따른 식각 공정 결과: VI Probe 활용 가능성 제안 (Gas Flow Rate Dependency of Etching Result: Use of VI Probe for Process Monitoring)

  • 송완수;홍상진
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.27-31
    • /
    • 2021
  • VI probe, which is one of various in-situ plasma monitoring sensor, is frequently used for in-situ process monitoring in mass production environment. In this paper, we correlated the plasma etch results with VI probe data with the small amount of gas flow rate changes to propose usefulness of the VI probe in real-time process monitoring. Several different sized contact holes were employed for the etch experiment, and the etched profiles were measured by scanning electron microscope (SEM). Although the shape of etched hole did not show satisfactory relationship with VI probe data, the chamber status changed along the incremental/decremental modification of the amount of gas flow was successfully observed in terms of impedance monitoring.

Experimental Results of Ship-To-Ship Lightering Operations Applied Velocity Information GPS

  • Yoo, Yun-Ja;Pedersen, Egil;Kouguchi, Nobuyoshi;Song, Chae-Uk
    • 한국항해항만학회지
    • /
    • 제38권6호
    • /
    • pp.577-583
    • /
    • 2014
  • A ship-to-ship (STS) lightering operation takes place in order to transfer cargo (e.g. crude oil or petroleum products) between an ocean-going ship and a service ship alongside it. Instrumental measurements to accurately determine the relative speeds and distances during the approach between the vessels would benefit the operational safety and efficiency. A velocity information GPS (VI-GPS) system, which uses the instantaneous velocity measures from carrier-phase Doppler measurement, has been applied in a field observation onboard a service ship (Aframax tanker) approaching a ship-to-be-lightered (VLCC) in open waters. This article proposes to apply VI-GPS as the input sensor to a guidance and decision-support system aiming to provide accurate velocity information to the officer in charge of an STS operation. A method for precise velocity measurement using VI-GPS was described and the measurement results were compared each other with the results of Voyage Data Recorder (VDR) and VI-GPS that showed the concept of a guidance and decision-support system applying VI-GPS with the field test results during STS operations. Also, it turned out that VI-GPS has sufficient accuracy to serve as an input sensor from the field test results.

Green Synthesis of Multifunctional Carbon Nanodots and Their Applications as a Smart Nanothermometer and Cr(VI) Ions Sensor

  • Li, Lu;Shao, Congying;Wu, Qian;Wang, Yunjian;Liu, Mingzhu
    • Nano
    • /
    • 제13권12호
    • /
    • pp.1850147.1-1850147.14
    • /
    • 2018
  • In this work, water-soluble and blue-emitting carbon nanodots (CDs) were synthesized from apple peels for the first time via one-step hydrothermal method. The synthetic route is facile, green, economical and viable. The as-prepared CDs were characterized thoroughly by transmission electron microscopy (TEM), X-ray diffraction (XRD), Raman, Fourier transform infrared (FT-IR), X-ray photoelectron (XPS), fluorescence and UV-Vis absorption spectroscopy in terms of their morphology, surface functional groups and optical properties. The results show that these CDs possessed ultrasmall size, good dispersivity, and high tolerance to pH, ionic strength and continuous UV irradiation. Significantly, the CDs had fast and reversible response towards temperature, and the accurate linear relationship between fluorescence intensity and temperature was used to design a novel nanothermometer in a broad temperature range from 5 to $65^{\circ}C$ facilely. In addition, the fluorescence intensity of CDs was observed to be quenched immediately by Cr(VI) ions based on the inner filter effect. A low-cost Cr(VI) ions sensor was proposed employing CDs as fluorescent probe, and it displayed a wide linear range from 0.5 to $200{\mu}M$ with a detection limit of $0.73{\mu}M$. The practicability of the developed Cr(VI) sensor for real water sample assay was also validated with satisfactory recoveries.

USN응용과 범용목적에 적용가능한 센서 신호처리기 (Sensor signal processing device for USN application and general purpose)

  • 박찬원;김일환;전삼석
    • 센서학회지
    • /
    • 제19권3호
    • /
    • pp.230-237
    • /
    • 2010
  • In sensor signal conditioning and processing, offset and drift characteristics of an operational amplifier are an important factor when the amplifier is used for a precise sensor signal amplifier. In order to use it in high accuracy, an expensive trimming or a complex compensation circuit is required. This paper presents the improved sensor signal conditioning and processing device for ubiquitous sensor network(USN) application or general purpose by developing a hardware of the circuit for reducing the offset voltage and drift characteristics, and a software for its control and sensor signal processing. We realize better offset voltage and drift characteristics of the signal conditioning circuit using low cost operational amplifiers. The experimental results show that this technique is effective in improving the performance of the sensor signal processing device.

다중분광광학센서를 활용한 농업가뭄의 토양수분-식생-이산화탄소 플럭스 관계 분석 (Assessment of soil moisture-vegetation-carbon flux relationship for agricultural drought using optical multispectral sensor)

  • 서찬양;남원호
    • 한국수자원학회논문집
    • /
    • 제56권11호
    • /
    • pp.721-728
    • /
    • 2023
  • 농업적 가뭄이 발생하면 토양의 수분이 감소하여 식생의 광합성 및 성장을 저해한다. 광합성을 통해 대기 중의 이산화탄소가 흡수되며 산소 생산량이 증가하는데, 이러한 광합성에 부정적인 영향이 생긴다면 대기 중의 이산화탄소 농도가 증가한다. 본 연구에서는 다중분광광학센서인 MODerate resolution Imaging Spectroradiometer (MODIS) 산출물을 이용하여 토양수분, 식생 활력 및 대기 중의 이산화탄소 농도 간의 관계를 분석하였다. 토양수분의 경우, 기존의 마이크로웨이브 센서는 낮은 공간 해상도로 제공되는 특징으로 인해 소규모 연구 지역 분석에 한계가 있어서 상대적으로 고해상도인 광학센서를 이용한 토양수분 산정 방법을 적용하였다. 또한, MODIS 총일차생산량(Gross Primary Productivity, GPP) 산출물을 이용하여 식생의 호흡과의 관계식을 이용하여 이산화탄소 플럭스를 계산하였다. 원격탐사 기반의 토양수분, 식생지수와 이산화탄소 플럭스를 국내의 극한 가뭄 발생시기인 2014년과 2015년도에 대하여 지점 관측 자료인 플럭스타워 값과 비교 분석하였다. 분석한 결과 토양수분과 식생지수 사이에는 한 달의 지체시간, 식생지수와 이산화탄소 플럭스 사이에는 2주 지체시간이 발생했을 때, 상관성이 높게 나타났다.

Effect of Electrical Muscle Stimulation Training With and Without Superimposed Voluntary Contraction on Rectus Femoris and Vastus Intermedius Thickness and Knee Extension Strength

  • Weon, Young-soo;Kim, Jun-hee;Gwak, Gyeong-tae;Lee, Do-eun;Kwon, Oh-yun
    • 한국전문물리치료학회지
    • /
    • 제29권2호
    • /
    • pp.140-146
    • /
    • 2022
  • Background: The superimposed technique (ST) involves the application of electrical muscle stimulation (EMS) during voluntary muscle action. The physiological effects attributed to each stimulus may be accumulated by the ST. Although various EMS devices for the quadriceps muscle are being marketed to the general public, there is still a lack of research on whether ST training can provide significant advantages for improving quadriceps muscle strength or thickness compared with EMS alone. Objective: To compare the effects of eight weeks of ST and EMS on the thicknesses of the rectus femoris (RF) and vastus intermedius (VI) muscles and knee extension strength. Methods: Thirty healthy subjects were recruited and randomly assigned to either the ST or EMS groups. The participants underwent ST or EMS training for eight weeks. In all participants, the thicknesses of the RF and VI muscles were measured before and after the 8-week intervention by ultrasonography, and quadriceps muscle strength was measured using the Smart KEMA tension sensor (KOREATECH Co., Ltd.). Results: There were significant differences in the pre- and post-intervention thicknesses of the RF and VI muscles as well as the quadriceps muscle strength in both groups (p < 0.05). RF thickness was significantly greater in the ST group (F = 4.294, p = 0.048), but there was no significant difference in VI thickness (F = 0.234, p = 0.632) or knee extension strength (F = 0.775, p = 0.386). Conclusion: EMS can be used to improve quadriceps muscle strength and RF and VI muscle thickness, and ST can be used to improve RF thickness in the context of athletic training and fitness.

13.56 MHz 임피던스 자동 정합 시스템을 위한 임피던스 에러율 향상 알고리즘 (Error Rate Enhancement Algorithm for 13.56 MHz Impedance Automatic Matching System)

  • 장광호;박수연;최진주;이동헌
    • 한국전자파학회논문지
    • /
    • 제29권7호
    • /
    • pp.484-490
    • /
    • 2018
  • 본 논문은 13.56 MHz 임피던스 자동 정합 시스템 내의 VI 센서를 이용하여 전압 신호와 전류 신호를 측정하고, 부하임피던스를 계산하는 새로운 알고리즘에 대해서 기술하였다. 기존의 $50{\Omega}$ 교정 부하로 하던 방식에서 벗어나 임의의 복소수 교정 부하를 사용하여 에러율이 향상되는 알고리즘을 제안한다. 에러율은 $R_{IN}$ 평균 1 % 이하, $X_{IN}$은 평균 20 %이하 목표로 한다. 일차적으로 믹서를 사용하여 IF 주파수를 계산하여 에러율을 줄였고, 두 번째로 임의의 복소수 부하를 교정 부하로 사용하였을 때 에러율이 $R_{IN}$은 평균 2.7 %에서 평균 0.3 %로 감소하였고, $X_{IN}$은 평균 102 %에서 평균 18.3%까지 감소하였습니다.

25.8kV급 N2 절연 지중다회로 개폐기 진단알고리즘 개발 (Development of Diagnosis Algorithm for 25.8kV N2 insulated Pad-mounted Switchgear)

  • 김춘원;장성일;최정환;김광호
    • 산업기술연구
    • /
    • 제34권
    • /
    • pp.67-70
    • /
    • 2014
  • In this paper, we propose a diagnosis algorithm for 25.8kV $N_2$ insulated Pad-mounted Switchgear in oder to improve reliability by preventing of fault in advance. The proposed algorithm can diagnose the problems of Pad-mounted Switchgear such as gas leakage and VI(Vacuum Interrupter) trouble (contact abrasion, coil aging etc.) by using pressure sensor, stroke sensor and coil current sensor.

  • PDF