• Title/Summary/Keyword: Vertical wall

Search Result 1,037, Processing Time 0.03 seconds

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

A Comparative Considerations of the Moat at the East and West (동.서양 해자(垓字)의 비교 고찰)

  • Jung, Yong-Jo;Park, Joo-Sung;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.29-38
    • /
    • 2010
  • A moat is a pond or waterway paved on the outside of a fortress that is one of the facilities to prevent enemy from approaching the fortress wall or classify it as the boundary space, and this study was undertaken to find out the characteristics of the moat that was existed in the East and the West from ancient time to medieval time with the following result. First, the moat in the East was installed of natural moat and artificial moat at the same time while the moat in the West had the fortress built in naturally advantageous site to use natural most substantially more. Second, the moats of Korea were smaller in scale compared to other countries (Japan, China and the Western countries). Third, the fortresses in the East were built to protect towns or royal palace while the West had the fortress to protect the residence of kings, lords, great wealthy persons and the like, and they were used jointly with the natural moat and artificial moat to defend against the infiltration of enemy. Fourth, the Pungsujiri in the Orient is one of the numerous ideologies forming the supplementary ideologic system of Korean people that could not be denied as the perception that influences on Korean people after the Silla Dynasty, and this Pungsujiri was considered when determining the location of the castle. The moat surrounding the castle had the role to keep the good energy in the castle from escaping away. Fifth, the Ha-Ha technique in the west was designed to prevent the external power from infiltration by digging the ditch on the place applicable to the boundary of the garden site, rather than the fence. While walking around along the water-side path without knowing the existence of this ditch, when the road is discovered with the cut off in the ditch, people had the exclamation without actually recognizing such astonishment. It was originally the dike for military purpose during the medieval time that was designed to look into the garden without physical boundary surrounded with the vertical fence in the garden that by having the deep ditch like shape on the boundary line of the garden which was designed to form the farm by preventing various types of cattle from coming inside the garden and bring in the garden element for farms, forestry, agricultural land and the like.

A Feasibility Study on the Deep Soil Mixing Barrier to Control Contaminated Groundwater (오염지하수의 확산방지를 위한 대체 혼합차수재의 적용에 관한 연구)

  • 김윤희;임동희;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.53-59
    • /
    • 2001
  • There is a lot of method to manage the insanitary landfill but vertical cutoff walls have been widespreadly used and were installed into the subsurface to act as a barrier to horizontal groundwater flow, The stabilized material such as specialized cement or mixed soil with additives has been generally applied for the materials of the deep soil mixing barrier in korea. The amount of the stabilized material is dependent on the field conditions, because the mixing ratio of the material and the field soil should achieve a requirement in the coefficient of permeability, lower than 1.0$\times$$10^{7}$cm/sec. This study determined the quantity and optimized function ratio of the stabilized material in the formation process of the mixed barrier that was added with stabilized material on the field soil classified into SW-SC under USCS (Unified Soil Classification System). After that the fly ash and lime were selected as an additives an that could improve the function of the stabilized material and then the method to improve the functional progress in the usage of putting into the stabilized material as an appropriate ratio was studied and reviewed. The author used the flexible-wall permeameter for measuring the permeability and unconfined compressive strength tester for compressive strength, and in the view of environmental engineering the absorption test of heavy metals and leaching test regulated by Korean Waste Management Act were performed. As the results, the suitable mixing ratio of the stabilized material in the deep soil mixing barrier was determined as 13 percent. To make workability easy, the ratio of stabilized material and water was proven to be 1 : 1.5. With the results, the range of the portion of the additives(fly ash : lime= 70 : 30) was proven to be 20-40% for improving the function of the stabilized material, lowering of permeability. In heavy metal absorption assessment of the mixing barrier system with the additives, the result of heavy metal absorption was proved to be almost same with the case of the original stabilized material; high removal efficiency of heavy metals. In addition, the leaching concentration of heavy metals from the leaching test for the environmental hazard assessment showed lower than the regulated criteria.

  • PDF

The influence of composite resin restoration on the stress distribution of notch shaped noncarious cervical lesion A three dimensional finite element analysis study (복합레진 수복물이 쐐기형 비우식성 치경부 병소의 응력 분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Lee, Chae-Kyung;Park, Jeong-Kil;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.69-79
    • /
    • 2007
  • The purpose of this study was to investigate the effects of composite resin restorations on the stress distribution of notch shaped noncarious cervical lesion using three-dimensional (3D) finite element analysis (FEA). Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072 ; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). ANSYS (Swanson Analysis Systems, Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid or flowable resin and each restoration was simulated with adhesive layer thickness ($40{\mu}m$) A static load of 500 N was applied on a point load condition at buccal cusp (loading A) and palatal cusp (loading B). The principal stresses in the lesion apex (internal line angle of cavity) and middle vertical wall were analyzed using ANSYS. The results were as follows 1. Under loading A, compressive stress is created in the unrestored and restored cavity. Under loading B, tensile stress is created. And the peak stress concentration is seen at near mesial corner of the cavity under each load condition. 2. Compared to the unrestored cavity, the principal stresses at the cemeto-enamel junction (CEJ) and internal line angle of the cavity were more reduced in the restored cavity on both load con ditions. 3. In teeth restored with hybrid composite, the principal stresses at the CEJ and internal line angle of the cavity were more reduced than flowable resin.

Activation Evaluation of Radiation Shield Wall (Concrete) in Cyclotron room using the Portable Nclide Analyzer Running Title: Activation Evaluation of Concrete in Cyclotron room (휴대용 핵종분석기를 활용한 사이클로트론실 내 차폐벽 방사화 평가)

  • Kim, Seongcheol;Gwon, Da Yeong;Jeon, Yeoryeong;Han, Jiyoung;Kim, Yongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose There are many cyclotrons compared to the land area of the Republic of Korea. Because GMP certification is required and the nuclear medicine test does not apply for insurance, the number of examinations for nuclear medicine is decreasing. Therefore, there is a high probability of early decommissioning of the cyclotron. However, we do not unusually perform the radioactivation evaluation on concrete that can be classified as radioactive waste during the decommissioning of the cyclotron. In this study, we aim to confirm the radioactivation in the concrete surface using Handheld Radionuclide Identification Devices (RIDs). Materials and Methods Because there is no cyclotron being decommissioning in the Republic of Korea, it was impossible to perform the coring of concrete for radioactivation analysis. In this study, we used the KIRAMS-13 and analyzed the concrete surface in the target direction in the cyclotron room. After setting the target direction as the center, radionuclides were measured for about five months at thirty points with vertical and horizontal intervals of 30 cm. We used the RIIDEye(Detector: NaI(Tl) detector, manufacturer: Thermo) in this study and set the measurement time per point to one day (24 hours). Results Co-60 and Cs-137 were detected in some measurement points, and we confirmed the radioactivity of Co-60 detected at the most points. As a result, we found that the radioactivity of Co-60 was high in the diagonal direction (from the lower-left direction to the upper right direction) based on the center of the target. However, we think it is impossible to apply the corresponding results to all cyclotrons because we performed the study using only one cyclotron. Conclusion In thirty measurement points, we could confirm the radioactive nuclides and the relative radioactivity using the results of portable nuclides analyzer. Therefore, we expect that we can use the portable nuclides analyzer to select the coring position of concrete during the decommissioning of the cyclotron. Also, if we secure the radioactivation data for several years, we expect to make a more accurate estimate of radioactive waste during the preparation period of decommissioning of the cyclotron.

Studies on the Functional Interrelation between the Vestibular Canals and the Extraocular Muscles (미로반규관(迷路半規管)과 외안근(外眼筋)의 기능적(機能的) 관계(關係)에 관(關)한 연구(硏究))

  • Kim, Jeh-Hyub
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.1-17
    • /
    • 1974
  • This experiment was designed to explore the specific functional interrelations between the vestibular semicircular canals and the extraocular muscles which may disclose the neural organization, connecting the vestibular canals and each ocular motor nuclei in the brain system, for vestibuloocular reflex mechanism. In urethane anesthetized rabbits, a fine wire insulated except the cut cross section of its tip was inserted into the canals closely to the ampullary receptor organs through the minute holes provided on the osseous canal wall for monopolar stimulation of each canal nerve. All extraocular muscles of both eyes were ligated and cut at their insertio, and the isometric tension and EMG responses of the extraocular muscles to the vestibular canal nerve stimulation were recorded by means of a physiographic recorder. Upon stimulation of the semicircular canal nerve, direction if the eye movement was also observed. The experimental results were as follows. 1) Single canal nerve stimulation with high frequency square waves (240 cps, 0. 1 msec) caused excitation of three extraocular muscles and inhibition of remaining three muscles in the bilateral eyes; stimulation of any canal nerve of a unilateral labyrinth caused excitation (contraction) of the superior rectus, superior oblique and medial rectus muscles and inhibition (relaxation) of the inferior rectus, inferior oblique and lateral rectos muscles in the ipsilateral eye, and it caused the opposite events in the contralateral eye. 2) By the overlapped stimulation of triple canal nerves of a unilateral labyrinth, unidirectional (excitatory or inhibitory) summation of the individual canal effects on a given extraocular muscles was demonstrated, and this indicates that three different canals of a unilateral vestibular system exert similar effect on a given extraocular muscles. 3) Based on the above experimental evidences, a simple rule by which one can define the vestibular excitatory and inhibitory input sources to all the extraocular muscles is proposed; the superior rectus, superior oblique and medial rectus muscles receive excitatory impulses from the ipsilateral vestibular canals, and the inferior rectus, inferior oblique and lateral rectus muscles from the contralateral canals; the opposite relationship applies for vestibular inhibitory impulses to the extraocular muscles. 4) According to the specific direction of the eye movements induced by the individual canal nerve stimulation, an extraocutar muscle exerting major role (a muscle of primary contraction) and two muscles of synergistic contraction could be differentiated in both eyes. 5) When these experimental results were compared to the well known observations of Cohen et al. (1964) made in the cats, extraocular muscles of primary contraction were the same but those of synergistic contraction were partially different. Moreover, the oblique muscle responses to each canal nerve excitation appeared to be all identical. However, the responnes of horizontal (medial and lateral) and vertical (superior and inferior) rectus muscles showed considerable differences. By critical analysis of these data, the author was able to locate theoretical contradictions in the observations of Cohen et al. but not in the author's results. 6) An attempt was also made to compare the functional observation of this experiment to the morphological findings of Carpenter and his associates obtained by degeneration experiments in the monkeys, and it was able to find some significant coincidence between there two works of different approach. In summary, the author has demonstrated that the well known observations of Cohen et al. on the vestibulo-ocular interrelation contain important experimental errors which can he proved by theoretical evaluation and substantiated by a series of experiments. Based on such experimental evidences, a new rule is proposed to define the interrelation between the vestibular canals and the extraocular muscles.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.