• Title/Summary/Keyword: Vertical pipe

Search Result 319, Processing Time 0.023 seconds

Numerical Study on Taylor Bubble Rising in Pipes

  • Shin, Seung Chul;Lee, Gang Nam;Jung, Kwang Hyo;Park, Hyun Jung;Park, Il Ryong;Suh, Sung-bu
    • 한국해양공학회지
    • /
    • 제35권1호
    • /
    • pp.38-49
    • /
    • 2021
  • Slug flow is the most common multi-phase flow encountered in oil and gas industry. In this study, the hydrodynamic features of flow in pipes investigated numerically using computational fluid dynamic (CFD) simulations for the effect of slug flow on the vertical and bent pipeline. The compressible Reynold averaged Navier-Stokes (RANS) equation was used as the governing equation, with the volume of fluid (VOF) method to capture the outline of the bubble in a pipeline. The simulations were tested for the grid and time step convergence, and validated with the experimental and theoretical results for the main hydrodynamic characteristics of the Taylor bubble, i.e., bubble shape, terminal velocity of bubble, and the liquid film velocity. The slug flow was simulated with various air and water injection velocities in the pipeline. The simulations revealed the effect of slug flow as the pressure occurring in the wall of the pipeline. The peak pressure and pressure oscillations were observed, and those magnitudes and trends were compared with the change in air and water injection velocities. The mechanism of the peak pressures was studied in relation with the change in bubble length, and the maximum peak pressures were investigated for the different positions and velocities of the air and water in the pipeline. The pressure oscillations were investigated in comparison with the bubble length in the pipe and the oscillation was provided with the application of damping. The pressures were compared with the case of a bent pipe, and a 1.5 times higher pressures was observed due to the compression of the bubbles at the corner of the bent. These findings can be used as a basic data for further studies and designs on pipeline systems with multi-phase flow.

Numerical analysis on two-phase flow-induced vibrations at different flow regimes in a spiral tube

  • Guangchao Yang;Xiaofei Yu;Yixiong Zhang;Guo Chen;Shanshan Bu;Ke Zhang;Deqi Chen
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1712-1724
    • /
    • 2024
  • Spiral tubes are used in a wide range of applications and it is significant to understand the vibration introduced by two-phase flow in spiral tubes. In this paper, the numerical method is used to study the vibration induced by the gas-liquid two-phase flow in a spiral tube with different flow regimes. The pressure fluctuation characteristics at the pipe wall and the solid vibration response characteristics are obtained. The results show that the motion of small bubbles in bubbly flow leads to small pressure fluctuations with low-frequency broadband (0-50 Hz). The motion of the gas plug in the plug flow causes small amplitude periodic pressure fluctuation with a shortened low-frequency broadband (0-15 Hz) compared to the bubbly flow. The motion of the gas slug in the slug flow causes large periodic fluctuations in pressure with a significant dominant frequency (6-7 Hz). The wavy flow is very stable and has a distinct main frequency (1-2 Hz). The vibration regime in the bubbly flow and wave flow are close to the first-order mode, and the vertical vibrating component is dominant. The plug flow and slug flow excite higher-order vibration modes, and the lateral vibration component plays more important part in the vibration response.

수직밀패형 지중열교환기의 설계인자가 보어홀 전열저항에 미치는 영향에 관한 연구 (A Study on the Effects of Design Parameters of Vertical Ground Heat Exchanger on the Borehole Thermal Resistance)

  • 장근선;김민준
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.128-135
    • /
    • 2018
  • 현재 지열 열펌프 시스템에 수직밀폐형 지중열교환기가 가장 많이 적용되고 있으며, 수직밀폐형 지중열교환기의 성능에 영향을 미치는 주요 인자로는 지중 열전도율(k)과 보어홀 전열저항($R_b$)이 있다. 본 연구에서는 현장에서 측정된 열응답시험 데이터를 이용하여 보어홀 전열저항을 계산하였으며 지중열교환기 개별 설계인자들(순환수유량, 파이프 수, 그라우팅재)이 보어홀 전열저항에 미치는 영향을 분석하였다. 또한 도출된 그라우팅 열저항은 문헌에 제시된 다양한 상관식과 비교 분석하였다. 시험데이터를 통해 본 시험에서의 지중열교환기 보어홀 전열저항은 0.1303 W/m.K로 나타났으며, 보어홀 전열저항에서 그라우트 열저항이 66.6 %, 파이프 열저항이 31.5 %, 순환수 대류열저항이 1.9 %를 차지하여 그라우트가 보어홀 열전달에 가장 큰 영향을 미치는 인자임을 확인하였다. 또한 각 설계인자의 설계변수가 보어홀 전열저항에 미치는 영향을 분석한 결과 실리카샌드를 혼합하여 그라우트 열전도율를 높이는 방법이 파이프 수 증가나 순환수 유량증가보다 열전달 증진에 더 효과적임을 알 수 있었다.

불규칙 단파가 신월저류배수시설의 수리적 안정성에 미치는 영향에 대한 실험 연구 (An experimental study on the influence of undular bore on the hydraulic stability at Shinwol rainwater storage and drainage system)

  • 오준오
    • 한국수자원학회논문집
    • /
    • 제52권5호
    • /
    • pp.313-323
    • /
    • 2019
  • 대심도 터널은 기 개발된 도시의 부족한 배수관망 능력을 보강하기 위하여 지하에 설치하는 대규모 도시홍수 배제 시설물로 역 사이펀 관로 형태를 하고 있는 시설물이다. 대심도 터널과 같은 구조에서는 하류에서 발생한 불규칙 단파에 의하여 터널의 수리적 안정성에 문제가 발생한다. 본 연구에서는 국내 최초로 건설 중인 '신월 빗물저류배수시설'의 수리적 안정성에 불규칙 단파가 미치는 영향을 알아보기 위하여 다양한 홍수유입 시나리오에 대하여 수리모형실험을 실시하였다. 본 연구에서 수행한 수리모형실험 결과 하류에서 발생한 불규칙 단파가 상류로 이동하면서 관 내 포집되어 압축상태인 공기덩어리를 밀어내는데, 이 공기덩어리가 상류 수직유입구를 통하여 급배기 되는 과정에 수직유입구를 질식시키고 홍수유입을 차단하여 월류가 발생하는 것으로 판단된다. 또한 불규칙 단파의 이동속도를 분석한 결과 불규칙 단파가 이동하면서 에너지를 전달하고 이때 관 내 압력 상승 및 불규칙 단파의 속도 증가분이 발생하는 것으로 판단된다. 대심도 터널의 수리적 안정성에 중요한 역할을 하는 불규칙 단파의 크기 및 속도 예측을 위한 추가 연구가 필요할 것으로 판단된다.

모형실험에 의한 경사말뚝의 거동 특성 (Behavior Characteristics of Batter Piles by Model Test)

  • 권오균;이활;석정우
    • 한국지반공학회논문집
    • /
    • 제20권8호
    • /
    • pp.59-66
    • /
    • 2004
  • 본 연구에서는 연직말뚝과 경사말뚝에 대하여 모형실험과 수치해석을 실시하여 경사말뚝의 거동 특성을 분석하였다. 상대밀도 79%인 모래지반에 경사각도 0$^{\circ}$, $10^{\circ}$, 20$^{\circ}$, 30$^{\circ}$의 강관말뚝을 항타 관입하여 하중재하실험을 실시하였고, 상용 유한요소 프로그램인 PENTAGON 3D를 이용하여 수치해석을 수행하였다. 모형실험에 의한 경사말뚝의 축방향 지지 력은 경사각도가 $10^{\circ}$, 20$^{\circ}$, 30$^{\circ}$에서 연직말뚝에 비하여 111, 95, 81%로 나타났고, 수치해석의 결과도 다소 차이는 있지만 비슷하게 나타났다. 그러나 Petrasovits & Award의 결과는 경사각 $10^{\circ}$에서 모형실험 결과와 유사하지만, 경사각 20$^{\circ}$와 30$^{\circ}$에서는 모형실험결과를 과대평가하였다. 경사각도에 따른 주면마찰력과 선단하중은 모형실험과 수치해석 모두 $10^{\circ}$경사에서 최대값을 나타낸 후, 경사각도가 증가함에 따라 감소하였고, 전체하중에서 주면마찰력과 선단하중의 구성비율은 경사각도에 관계없이 거의 비슷하게 나타났다.

방향성 소구경 굴착의 입자 이송특성에 관한 연구 (An Experimental Study of Cuttings Transport in Directional Slim Hole Drilling)

  • 한상목;김정환;황영규;우남섭;김영주
    • 한국해양공학회지
    • /
    • 제26권2호
    • /
    • pp.20-25
    • /
    • 2012
  • During drilling, the precipitation velocity of cuttings within an annulus depends on the density and configuration of the cuttings, and on the density, viscosity, and rheological characteristics of the drilling fluid. In directional drilling in particular, it is difficult to adjust and control the cuttings. In contrast to vertical drilling, it is very important to evaluate the flow characteristics of a drilling flow field. However, research on the transfer features of cuttings is inadequate. In this study, in order to identify transfer features of cuttings, an experiment was performed under wide-ranging conditions by constructing a slim hole annulus ($44mm{\times}30mm$) device. In this experiment, the particle volume fraction were influenced by particle size, particle concentration within the flow, pipe rotation, flow volume, and inclination of the annulus. In addition, a mathematical formula for volumetric concentration was deduced and compared to the test results and behavior of cuttings under the other drilling condition was made to be predicted. Therefore, this study can provide meaningful data for vertical and horizontal drilling, and for directional drilling.

원형바닥젵의 유속구조 해석 (Analysis of Velocity Structure of Round Wall Jet)

  • 김대근;서일원
    • 한국수자원학회논문집
    • /
    • 제30권5호
    • /
    • pp.467-475
    • /
    • 1997
  • 본 연구에서는 실험개수로에 온수방류용 방류규가 있는 방파제의 모형을 설피하여 바닥\ulcorner의 유속분포를 측정하였다. 또한 3차원의 모형인 Fluent 모형을 이용하여 방파제의 방류구로부터 배출된 바닥젵의 유속구조를 수치모의하여 실험결과와 비교.검증하였으며 흐름특성을 규명하였다. 바닥젵은 자유젵에 비하여 흐름의 확립구간이 짧았으며, 종방향거리에 대한 젵 중앙유속의 감쇠율이 자유젵보다 크게 나타나고 있음이 밝혀졌다. 단순젵과 부력젵의 젵 중앙선에서의 종방향유속을 비교한 결과, 방류구 근처에서는 부력\ulcorner의 유속이 크게 발생하나 x/lQ가 15보다 큰 구간에는 도리어 작게 된다. 종방향유속의 연직분포를 비교한 결고, 방류구로부터 멀어질수록 저층에서는 단순젵의 유속이 크게 나타나며 상충에서는 단순젵의 부의 유속이 크게 나타나고 있음이 밝혀졌다. 또한 부력젵의 경우 자유수면에서의 유속의 분리가 단순젵보다 방류구로부터 가까운 거리에서 발생한다. 부력젵의 연직방향으로의 폭은 단순젵의 폭보다 빨리 확장된다.

  • PDF

Modeling and simulation of air-water upward annular flow characteristics in a vertical tube using CFD

  • Anadi Mondal;Subash L Sharma
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2881-2892
    • /
    • 2024
  • Annular flow refers to a special type of two-phase flow pattern in which liquid flows as a thin film at the periphery of a pipe, tube, or conduit, and gas with relatively high velocity flows at the center of the flow section. This gas also includes dispersed liquid droplets. The liquid film flow rate continuously changes inside the tube due to two processes-entrainment and deposition. To determine the liquid holdup, pressure drop, the onset of dryout, and heat transfer characteristics in annular flow, it is important to have proper knowledge of flow characteristics. Especially a better understanding of entrainment fraction is important for the heat transfer and safe operation of two-phase flow systems operating in an annular two-phase flow regime. Therefore, the objective of this work is to develop a computational model for the simulation of the annular two-phase flow regime and assess the various existing models for the entrainment rate. In this work, Computational Fluid Dynamics (CFD) in ANSYS FLUENT has been applied to determine annular flow characteristics such as liquid film thickness, film velocity, entrainment rate, deposition rate, and entrainment fraction for various gas-liquid flow conditions in a vertical upward tube. The gas core with droplets was simulated using the Discrete Phase Model (DPM) which is based on the Eulerian-Lagrangian approach. The Eulerian Wall Film (EWF) model was utilized to simulate liquid film on the tube wall. Three different models of Entrainment rate were implemented and assessed through user-defined functions (UDF) in ANSYS. Finally, entrainment for fully developed flow was determined and compared with the experimental data available in the literature. From the simulations, it was obtained that the Bertodano correlation performed best in predicting entrainment fraction and the results were within the ±30 % limit when compared to experimental data.

10MW급 해양온도차발전을 위한 라이저 개념설계 (Conceptual Design of a Riser for 10 MW OTEC)

  • 정동호;권용주;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권1호
    • /
    • pp.29-35
    • /
    • 2015
  • 본 연구에서는 10 MW 용 라이저의 개념설계를 수행하며, 수치해석을 통하여 개념설계안에 대한 동적거동 특성을 분석한다. 전체 시스템은 크게 두 가지 개념으로 제안하며, 라이저가 자유롭게 매달린 형상을 가지는 경우에 대하여 라이저의 단면 설계를 수행한다. 라이저의 단면계수를 증가시키고, 비중을 조절하기 위하여 라이저 두께에 따라 중공을 형성하는 설계안에서는 라이저 아래 끝단에 중량체를 설치한다. 중공 없이 균일한 FRP 재질로 이루어진 라이저는 끝단 중량체 없이 자유롭게 매달린 형상으로 설계된다. 두 가지 설계 개념에 대하여 거동 특성 분석과 안전성 평가를 위하여 동적 거동해석을 수행한다. 끝단 중량체가 설치된 중공을 가지는 라이저의 응력은 중량체의 중량에 지배되는 것을 알 수 있다. 중량체 없이 자유롭게 매달린 라이저는 강한 조류가 작용하는 환경에서 파랑 및 부유체 가진이 작용하는 경우에, 해수면 부근에 응력이 집중되는 것을 알 수 있다. 자유롭게 매달린 대구경 라이저의 설계에서 조류는 매우 중요한 설계 요소라는 것을 알 수 있으며, 라이저 하부 끝단에 중량체를 설치함으로써 응력을 일부 줄일 수 있다는 것으로 나타났다.

건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구 (A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation)

  • 이용호;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.