• Title/Summary/Keyword: Vertical or Horizontal displacement

Search Result 63, Processing Time 0.034 seconds

Lateral Load Test for Various Aseismatic Methods of Pile Heads of Pier Type Quay Walls (잔교식 안벽의 말뚝 두부 내진 보강기법에 따른 수평재하실험)

  • 이용재;한진태;장인성;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.98-106
    • /
    • 2003
  • To construct pile-supported wharf structures that must support heavy horizontal loads, both vertical piles and batter piles are used. Batter piles are used to secure the bearing capacity against the horizontal loads. However, past case histories have shown that the heads of batter piles are vulnerable because these heads are subjected to excessive axial loads during earthquakes. Therefore, the aseismatic reinforcement method must be developed to prevent batter pile heads from breaking due to excessive seismic loads. Two different connecting methods of either inserting rubber or ball-bearing between batter pile head and upper plate were proposed to improve the aseismatic efficiency. Three large-scale pile head models(rubber type model, ball-bearing type model, and fixed type model) were manufactured and horizontal loading tests were peformed for these models. The results showed that the force-displacement relationship of the fixed type model was linear, but that of the rubber type model and the ball-bearing type model was bilinear. The increase in the horizontal displacement led to the increase in the horizontal stiffness of the rubber type models and the decrease in that of the ball-bearing type model. Compared with the values for fixed type model, the damping ratios of the rubber type model and the ball-bearing type model increased about 33~185% and 263~269%, respectively.

  • PDF

Horizontal Behavior Characteristics of Umbrella-Type Micropile Applied in Soft Clay Ground subjected to Seismic Motion (연약점토지반에 적용한 우산형 마이크로파일의 지진시 수평거동 특성)

  • Kim, Soo-Bong;Son, Su-Won;Kim, Jin-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.687-695
    • /
    • 2020
  • Micropile is used to improve the stability of existing structures as well as solve various geotechnical problems, such as suppressing slope activity and shearing keys of retaining walls. The existing micropile method has a significantly less capacity to resist a horizontal force than a vertical force0355 Therefore, it is necessary to develop and study an umbrella-type micropile method with excellent seismic performance that can secure seismic performance economically while minimizing structures and ground disturbance areas in the limited space of existing structures. In this study, numerical analysis was performed on the umbrella-type micropile, in which the sloped pile and vertical pile were combined, and the horizontal behavior in soft clay ground during earthquakes was analyzed. Numerical analysis showed that umbrella-type micropile suppresses horizontal displacement in soft ground, and the effect of reducing the horizontal displacement was more pronounced when the embedded depth of the slope pile was 15 m or more. The embedded depth of the micropile and horizontal displacement suppression effect was proportional. Therefore, the umbrella-type micropile has an excellent effect of suppressing horizontal displacement during earthquakes on soft clay ground.

Characterization of stacked geotextile tube structure using digital image correlation

  • Dong-Ju Kim;Dong Geon Son;Jong-Sub Lee;Thomas H.-K. Kang;Tae Sup Yun;Yong-Hoon Byun
    • Computers and Concrete
    • /
    • v.31 no.5
    • /
    • pp.385-394
    • /
    • 2023
  • Displacement is an important element for evaluating the stability and failure mechanism of hydraulic structures. Digital image correlation (DIC) is a useful technique to measure a three-dimensional displacement field using two cameras without any contact with test material. The objective of this study is to evaluate the behavior of stacked geotextile tubes using the DIC technique. Geotextile tubes are stacked to build a small-scale temporary dam model to exclude water from a specific area. The horizontal and vertical displacements of four stacked geotextile tubes are monitored using a dual camera system according to the upstream water level. The geotextile tubes are prepared with two different fill materials. For each dam model, the interface layers between upper and lower geotextile tubes are either unreinforced or reinforced with a cementitious binder. The displacement of stacked geotextile tubes is measured to analyze the behavior of geotextile tubes. Experimental results show that as upstream water level increases, horizontal and vertical displacements at each layer of geotextile tubes initially increase with water level, and then remain almost constant until the subsequent water level. The displacement of stacked geotextile tubes depends on the type of fill material and interfacial reinforcement with a cementitious binder. Thus, the proposed DIC technique can be effectively used to evaluate the behavior of a hydraulic structure, which consists of geotextile tubes.

A Study on the Stability and Behavior of upward Soil-nailing (상향으로 설치된 쏘일네일링의 안정성 및 거동에 관한 연구)

  • Kim, Jae-Yoon;Lee, In;Choi, Geun-Hyeok;Kim, Hong-Taek
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1086-1091
    • /
    • 2009
  • The purpose of this study is to provide the technical information of the stability change and behaviour characteristics in case upward direction of soil nailing is installed. Generally, the soil nailing which installed in case of vertical excavation or for the purpose of the slope stability is installed between 5 to 15 degree of downward direction. The downward direction of the soil nailing method has lots of advantages such as the increase of the stability, the convenience of the grout compared to upward direction of soil nailing. Even though the upward direction of the soil nailing has the disadvantages in terms of the stability and the grout construction, horizontal displacement tends to be decreased.

  • PDF

Finite Element Analysis of Gabled Hyperbolic Paraboloid Shells Subjected to Support Movements (지점변형을 하는 모임지붕형 쌍곡포물선쉘의 유한요소 해석)

  • Kim, Seung-Nam;Yu, Eun-Jong;Rha, Chang-Soon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.4
    • /
    • pp.57-69
    • /
    • 2012
  • This study investigated the behaviors of the gabled hyperbolic paraboloid shell structure subjected to differential settlement and the horizontal displacement due to the elongation of tie rod/beam on supports. Two types of shell structure with different roof slopes are used in study; conventional type which has perimeter beams around the shell panel, and simple type which removes the edge beams along the slab edge line. The effect of the removal of edge beam under vertical or horizontal displacement on supports, and the roof slope was compared using the finite element analysis.

Response of structure with controlled uplift using footing weight

  • Qin, X.;Chouw, N.
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.555-564
    • /
    • 2018
  • Allowing structures to uplift in earthquakes can significantly reduce or even avoid the development of plastic hinges within the structure. The permanent deformations in the structure can thus be minimized. However, uplift of footings can cause additional horizontal movements of a structure. With an increase in movement relative to adjacent structures, the probability of pounding between structures increases. This experimental study reveals that the footing mass can be used to control the vertical displacement of footing and thus reduce the horizontal displacements of an upliftable structure. A four storey model structure with plastic hinges and uplift capability was considered. Shake table tests using ten different earthquake records were conducted. Three different footing masses were considered. It is found that the amplitude of footing uplift can be greatly reduced by increasing the mass of the footing. As a result, allowing structural uplift does not necessary increase the horizontal displacement of the structure. The results show that with increasing footing weight, the interaction between structural and footing response can increase the contribution of the higher modes to the structural response. Consequently, the induced vibrations on secondary structure increase.

Experimental Study on the Relation Between the Longitudinal Articulation Part of a Spacer Damper and Subspan Oscillations (스페이서댐퍼 클램프의 선로방향 관절부와 서브스판진동과의 관계 실험적 고찰)

  • Lee, Hyung-Kwon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.447-450
    • /
    • 2009
  • In order to protect conductors from oscillations or vibrations due to winds, spacer dampers are installed on overhead transmission lines. Generally the spacer damper clamp can move slightly according to oscillation directions, namely in longitudinal, vertical & horizontal directions. This is for reducing fatigue phenomena of the conductor. But the high longitudinal- displacement of the clamp raises a doubt for its necessity. Then this paper carried out oscillation tests by using 4 bundle test lines, to know the relation between longitudinal displacement and oscillation. and suggests design necessity of the longitudinal articulation part for spacer damper clamps.

An experimental study on the behavior of the helical tiebacks in the flexible retaining walls

  • Majid Khanjani;Hamid Reza Saba;Seyed Hamid Lajevardi;Seyed Mohammad Mirhosseini;Ehsanollah Zeighami
    • Geomechanics and Engineering
    • /
    • v.36 no.6
    • /
    • pp.527-543
    • /
    • 2024
  • In the implementation of most civil structures, especially underground, deep excavations with a vertical slope are required. Using flexible retaining walls is applied as one of the ways to stabilize vertical holes. Therefore, it is necessary to know the parameters affecting the performance of such walls in reducing their horizontal movement. In this research, by building a suitable laboratory model, the parameters of the amount of flexibility, the embedment depth of the wall, the type and number of tieback in the wall were investigated for 42 static laboratory models. The purpose of this research is to study the flexible retaining wall with helical tieback compared to simple tieback at different heights, which shows the best performance in terms of reducing horizontal displacement in proportion to increasing or decreasing flexibility. On the other hand, one of the parameters affecting the flexibility of the wall, which is its bending stiffness, was extracted by numerical software outputs and studied on the results such as relative flexibility, stiffness, safety and numerical stability of the wall.The results of this study show that among the parameters, in the first place, the effect of the type of tieback is inhibited and in the second place, the ratio of thickness to wall height is known as the most important parameter. the best performance for walls with the helical tiebacks in reducing their horizontal displacement can be economically, flexibly and stability assigned to a wall that tiebacks is in the range of H2/t to H4/t and its flexibility ratio is 2/3.

Experimental study for the spacer damper clamp displacement due to subspan oscillations (가공선로 서브스판진동이 스페이서댐퍼 클램프 변위에 미치는 영향 실험적 고찰)

  • Lee, H.K.;Han, H.J.;Bang, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2094-2095
    • /
    • 2008
  • In order to protect conductors from oscillations or vibrations due to winds, spacer dampers or spacers are installed on bundled conductors in overhead transmission lines. Generally the spacer damper clamp can move slightly according to oscillation directions, namely conductor direction, vertical & horizontal direction This is for reducing fatigue phenomena of the clamps. Sometimes movement of the clamp to conductor direction raises a doubt for its necessity. Then this paper carried out oscillation tests to know clamp displacement due to the subspan oscillation.

  • PDF

An Analysis on Stress Distribution within Soft Layer Subject to Embomkment Loading (유안요소법에 의한 식중응력의 해석)

  • Park, Byeong-Gi;Lee, Mun-Su;Lee, Jin-Su
    • Geotechnical Engineering
    • /
    • v.1 no.1
    • /
    • pp.73-84
    • /
    • 1985
  • This Paper aims at investigating the distribution of stresses and the displacement of soft foundation layer subject to embankment load by the finite elements method (FEM). The stresses include the volumetric stress, the Pore water Pressure, the vertical stress. The horizontal stress and the shear stress. The Christian-Boehmer's method was selected as technique for FEM and the general elasticity model and modified Cam-clay model as the governing equations under Plain-strain condition depending on drained and undrained conditions. The results obtained are as follows: 1. The volumetric stress is almost consistent with the pore water pressure. This means that the total stress is the same value with the pore water pressure under the undrined condition 2. The vertical stress appears in the same value regardless of the drained or undrained condition and the model of the constitutive equations. 3. The horizontal stress has almost same value with the drain condition model. 4. depending on the constitutive model. The shear stress is affected by both the drain condition and the constitute model. The resulted value by the modified Cam-clay model has the largest. 5. The direction of the displacement vector turns outward near the tip of load during the increasing load. 6. The magnitude of displacement due to the modified Cam.clay model is as twice large as that due to elastic model.

  • PDF