• 제목/요약/키워드: Vertical circulation

검색결과 240건 처리시간 0.027초

대공간 열환경 특성에 관한 수직순환기류의 영향 (Effect of the Vertical Air Circulation on the Thermal "Environment in a Large Space)

  • 김경환;강석윤;최충현;조영진;이재헌;오명도
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.581-588
    • /
    • 2000
  • This paper describes the effect of vertical air circulation on the thermal environment in an airport passenger terminal with induced flow by jet fans. In comparing the level of thermal comfort at the breathing line of 1.5 m in height, the results from the two models with or without the vertical air circulation, show that the average PPD is 8% in the former and 23% in the latter, respectively. It is thought that vertical air circulation lends to improved thermal comfort for human in respect of ventilation in a large space.

  • PDF

박물관 대공간(Major Space)의 동선구조 형식과 특성에 관한 연구 (A Study on the Type and Characteristics of the Circulation in Major Space of Museums)

  • 박세민;정성욱
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.209-213
    • /
    • 2008
  • This study is intended to propose a plan index that can be used in the early stage of a museum design based on theoretical review of a major space of a museum including its spatial division, functions and roles. The scope of the study includes functions and roles of circulation in a major space based on precedent studies. The spatial range is limited to a major space among exhibition spaces in a museum. This study analyzes overseas 14 museums. In terms of methodology, the study analyzes circulation in a descriptive way only In the focusing on floor plan and section composition. The results of this study are as follows. First, vertical elements should be critically considered in a circulation plan for functional performance of dimensional circulation distribution in a major space. Second, a plan by location of vertical and horizontal moving elements related to a major space affects a circulation relation more than a connection type between a major space and an exhibition area.

  • PDF

Townscape in a High-rise: Imageability and Accessibility of Vertical Malls in Hong Kong

  • Tan, Zheng
    • 국제초고층학회논문집
    • /
    • 제4권2호
    • /
    • pp.143-152
    • /
    • 2015
  • The increasing integration of public space and consumerism in Hong Kong has yielded new urban forms. The emergent vertical malls in Hong Kong and other East Asian metropolises have overturned the existing vertical order of the city. This vertical order is determined by the level of accessibility, but is being challenged by widely adopted vertical circulation technology. Inspired by Fredric Jameson's and Rem Koolhaas' reflections on the cultural significance of vertical transportation, this article examines the conflict between market logic and urban design requirements in the vertical interior spaces. "Departmentalization," as the current programming formula for vertical malls, can be further optimized by critically applying urban design doctrines such as Kevin Lynch's five elements of city image. It concludes with a statement that the knowledge base of vertical urbanism should be open to a set of new terminology informed by a new technological environment.

두 가지 연직혼합방안에 따른 해양대순환모형 혼합층깊이 및 상층수온 모사 민감도 비교 (A Comparison of Two Vertical-Mixing Schemes on the Simulation of the Mixed Layer Depth and Upper Ocean Temperature in an Ocean General Circulation Model)

  • 이동원;장찬주;예상욱;박태욱;신호정;김동훈;국종성
    • Ocean and Polar Research
    • /
    • 제35권3호
    • /
    • pp.249-258
    • /
    • 2013
  • Vertical and horizontal mixing processes in the ocean mixed layer determine sea surface temperature and temperature variability. Accordingly, simulating these processes properly is crucial in order to obtain more accurate climate simulations and more reliable future projections using an ocean general circulation model (OGCM). In this study, by using Modular Ocean Model version 4 (MOM4) developed by Geophysical Fluid Dynamics Laboratory, the upper ocean temperature and mixed layer depth were simulated with two different vertical mixing schemes that are most widely used and then compared. The resultant differences were analyzed to understand the underlying mechanism, especially in the Tropical Pacific Ocean where the differences appeared to be the greatest. One of the schemes was the so-called KPP scheme that uses K-Profile parameterization with nonlocal vertical mixing and the other was the N scheme that was rather recently developed based on a second-order turbulence closure. In the equatorial Pacific, the N scheme simulates the mixed layer at a deeper level than the KPP scheme. One of the reasons is that the total vertical diffusivity coefficient simulated with the N scheme is ten times larger, at maximum, in the surface layer compared to the KPP scheme. Another reason is that the zonal current simulated with the N scheme peaks at a deeper ocean level than the KPP scheme, which indicates that the vertical shear was simulated on a larger scale by the N scheme and it enhanced the mixed layer depth. It is notable that while the N scheme simulates a deeper mixed layer in the equatorial Pacific compared to the KPP scheme, the sea surface temperature (SST) simulated with the N scheme was cooler in the central Pacific and warmer in the eastern Pacific. We postulated that the reason for this is that in the central Pacific atmospheric forcing plays an important role in determining SST and so does a strong upwelling in the eastern Pacific. In conclusion, what determines SST is crucial in interpreting the relationship between SST and mixed layer depth.

내부순환유동을 고려한 연소하는 액적들의 상호작용 (Interaction of burning droplets with internal circulation)

  • 조종표;김호영;정진택
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.183-191
    • /
    • 2004
  • The burning characteristics of interacting droplets with internal circulation in a convective flow are numerically investigated at various Reynolds numbers. The transient combustion of 2-dimensionally arranged droplets, both the fixed droplet distances of 5 radii to 40 radii horizontally and 4 radii to 24 radii vertically, is studied. The results obtained from the present numerical analysis reveal that the transient flame configuration and retardation of droplet internal motion with the horizontal or vertical droplet spacing substantially influence lifetime of interacting droplets. At a low Reynolds number, lifetime of the two droplets with decreasing horizontal droplet spacing increases monotonically, whereas their lifetime with decreasing vertical droplet spacing decreases due to flow acceleration. This flow acceleration effect is reversed when the vertical droplet spacing is smaller than 5 radii in which decreasing flame penetration depth causes the reduction of heat transfer from flame to droplets. At a high Reynolds number, however, lifetime of the first droplet is hardly affected by either the horizontal droplet spacing or flow acceleration effect. Lifetime with decreasing vertical droplet spacing increases due to reduction of flame penetration depth. Lifetime of interacting droplets exhibits a strong dependence on Reynolds number, the horizontal droplet spacing and the vertical droplet spacing and can be con-elated well with these conditions to that of single burning droplet.

  • PDF

미술계뮤지엄의 다층화에 따른 동선체계의 변화에 관한 연구 - 유럽 소재 뮤지엄을 중심으로 - (A Study on Circulation System in conjunction with the multi-floored Art Museum - With reference to art museum in Europe -)

  • 문정묵
    • 한국실내디자인학회논문집
    • /
    • 제19권2호
    • /
    • pp.107-116
    • /
    • 2010
  • In Europe, traditionally the low-rised buildings for public art museum have been constructed since the 18th century like any other buildings and these are because of the technical issue for construction difficulty. Even if the low-rised art museum buildings are still continued for it's construction, gradually the high-rised art museum buildings begin to be build due to the development of contemporary technology in high-dense modern urban space. This tendency of high-rised art museum building in recent years is expected to affect on the interior space of it and most of all the spatial change in conjunction with circulation system variation is remarkable. Because the circulation system in art museum means tourist's spatial experience and it normally controls the experience of knowledge in art museum. This study is to understand how the multi-floored art museums in Europe affect to the spatial structure and how this is related to the circulation system. And also the study raised an issue on what it's social meaning is. Through these analysis the study can provide the meaning of multi-floored art museum and basic indication in art museum planning. To understand this, the study calculated the number of stories, number of vertical circulation and number of ring-structure space. Also the study tired to use space syntax tools, which are connectivity, integration value, integration value in major space, integration value in vertical circulation and intelligibility value. those tools alculated topological transfiguration of the whole space.Throughout the study, it was concluded that the influence of high-rised art museum in Europe changed the spatial structure and circulation system. The topological center of art museum that has been the grand space since 18th century changed to the vertical circulation due to the it's roll of distributing visitors to each floor. It became a starting point of spatial deployment and experience in art museum.

소형 자연순환 수직형 증발기 해석 및 성능실험 (Performance Analysis and Test of a Small-Scale Natural Circulation Vertical Evaporator)

  • 차상진;김내현;유진상
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.595-603
    • /
    • 2011
  • In this study, an effort has been made to analyze the subcooled boiling heat transfer in a natural circulation vertical evaporator. To verify the analysis, a small-scale model was made and tested. The friction correlation by Ueda, void fraction and quality correlation by Saha and Zuber along with the superposition heat transfer model by Rohsenow yielded a satisfactory agreement with the model test data. The analysis was extended to simulate a 1 ton/day concentration system. Comparison with the test results of 1 ton/day prototype revealed that the data were overpredicted by 13%. The capacity of the prototype was 1.2 ton/day with COP of 5.77.

현 기후 모델에서 모의되는 20세기 후반 해들리 순환 변화의 특징 (The Characteristics of the Change of Hadley Circulation during the Late 20th Century in the Current AOGCMs)

  • 신상희;정일웅
    • 대기
    • /
    • 제22권3호
    • /
    • pp.331-344
    • /
    • 2012
  • The changes in the Hadley circulation during the second half of the 20th century were examined using observations and the 20C3M (Twentieth Century Climate in Coupled Models) simulations by the 21 IPCC AR4 models. Multi-model ensemble (MME) mean shows that the mean features of the Hadley circulation, such as the intensity, magnitude, and the seasonal variations, are very realistically reproduced, compared to the ERA40 reanalysis. But the long-term trends of the Hadley circulation in 20C3M MME are quite different to those of observations. The observed intensity of the Hadley cell is persistently enhanced, particularly during boreal winter. In comparison, the meridional overturning circulations reproduced in the MME mean remains invariant in time, and even weakened in boreal summer. This discrepancy between the ERA40 and 20C3M MME is consistently shown in the overall structure of the Hadley circulations, such as mass streamfunction, the velocity potential, the vertical shear of meridional wind, and the vertical velocity in the tropical region. This results indicate that the current climate models are skill-less to capture the long-term trend of Hadley circulation yet, and should be improved in simulation of the large-scale features to enhance the confidence level of future climate change projection.

여객-화물 복합열차의 화물 배치방법에 관한 연구 (A Study on the Baggage Allocation Method of Passenger-Baggage Hybrid Train)

  • 최용훈;신상훈;한기평
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3426-3433
    • /
    • 2015
  • 본 논문은 제한된 철도 수송능력 환경에서 여객과 화물을 동시에 수송하기 위한 복합화물열차의 화물 배치를 위한 방법 중, 라운드 컨베이어 시스템과 세로형 순환식 시스템. 가로형 순환식 시스템을 각각 P 택배사의 지역간 운송 화물량을 기준으로 부산에서 대구, 대전, 오송을 거쳐 서울에 도착함을 가정하여 각각 도착역별로 상하차 시간을 계산하였다. 그 결과 가로형 순환식 시스템은 화물 적재 가능량도 적었으며 상하차 시간도 434초로 가장 많이 소요되었고 세로형 순환식 시스템이 상차 시간이 다소 많이 소요되었지만, 총 소요시간에서는 408초로 가장 우수한 특성을 보였다. 각각 시스템별로 상하차 시간을 비교함으로 향후 복합화물열차 제작시에 유용한 방법을 제시하고 복합화물열차의 화물 운송 효율을 증진하고자 한다.

박물관에 있어서의 수직동선 요소에 대한 기초적 연구 (A Basic Study on the Vertical Circulation Elements in a Museum)

  • 심승현
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.3964-3973
    • /
    • 2010
  • 본 연구는 박물관에 있어서 계단, 엘리베이터 등의 수직동선 요소에 대한 분석을 하고자 한다. 연구 방법에 있어 가장 기초 단계라는 의미로 각 요소별의 개수를 분석하여 수치적으로 접근하였다. 공간적 범위를 우리나라로 한정하였다. 연구의 결론은 다음과 같다. 첫째, 수직동선 요소를 가장 많이 지닌 사례는 8개이며, 3~4개가 50%를 차지하였다. 연구 초기에 생각했던 것보다 높은 수치의 사례가 있어 다양한 박물관의 실상을 알 수 있었다. 계단의 경우 5개가 제일 높았으며, 일반적으로는 2개의 계단을 가진 것이었다. 엘리베이터의 경우는 1개를 가진 사례가 79%였다. 경사로는 38개 사례 중 9개의 사례에서만 볼 수 있었으며, 1개를 가진 사례가 66%를 차지하였다. 3개 가진 사례도 있었으며, 앞으로의 건축설계의 추세를 보면 더 많은 경사로를 지닌 사례가 나올 것으로 예측된다. 둘째, 코어의 구성에 있어 계단 단독, 엘리베이터 단독, 경사로 단독, 엘리베이터 + 계단, 계단 + 경사로의 구성을 찾을 수 있었으나 엘리베이터 + 경사로, 엘리베이터 + 계단 + 경사로의 조합은 아직 찾을 수 없었다. 계단 + 경사로의 사례는 단 1개이다. 앞으로 계단 + 경사로, 엘리베이터 + 경사로, 엘리베이터 + 계단 + 경사로의 조합을 이용하여 설계한다면 다양한 모습의 박물관이 나타날 수 있을 것으로 예상된다.