• Title/Summary/Keyword: Vertical Well

Search Result 1,910, Processing Time 0.03 seconds

On the Development of Seakeeping Performance Evaluation System with Establishment a Safety Space (안전공간 설정에 의한 선박 내항성능의 평가시스템 개발에 관한 연구)

  • 김순갑;공길영
    • Journal of the Korean Institute of Navigation
    • /
    • v.16 no.1
    • /
    • pp.14-35
    • /
    • 1992
  • The recently-developed automated vessels require a system which evaluates the operating conditions of the ship at present position from weather information as well as sensors ; forecasting the operations condition in the state to come in foreseeable future ; and suggests the optimum course and speed for ship's safety. According to a study, deck wetness, propeller racing, slamming. rolling, vertical acceleration, lateral acceleration, vertical bending moment at midship etc. were chosen as the factors for evaluating seakeeping performance. As a matter of act, there is no developing the hardware of a system which could consider all the factors on seakeeping performance. This study introduces a theoretical method which makes it possible to evaluate the seakeeping performance by applying a theory from reliability engineering, and thereby establishing a safety space. The author adopts rolling and pitching as the factors on seakeeping performance by clarifying the correlation of stochastic processes the factors presently adopted for evaluation system in consideration of the safety of human being, cargoes and the ship. This method of evaluation shall be of much use in developing the practical system of seakeeping performance of a ship in waves.

  • PDF

Characteristics of Negative Peak Wind Pressure acting on Tall Buildings with Step on Wall Surface

  • Yoshida, Akihito;Masuyama, Yuka;Katsumura, Akira
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.4
    • /
    • pp.283-290
    • /
    • 2019
  • Corner cut, corner chamfered or a building shape change are adopted in the design of tall buildings to achieve aerodynamic superiority as well as response reduction. Kikuchi et.al pointed out that large negative peak external pressures can appear near the inside corner of set-back low rise buildings. It is therefore necessary to pay attention to facade design around steps in building surfaces. Peak wind pressures for corner cut or corner chamfered configurations are given in the AIJ code. However, they cannot be applied where there are many variations of vertical and horizontal steps. There has been no previous systematic research on peak wind pressures around steps in building surfaces. In this study, detailed phenomenon of peak wind pressures around steps in buildings are investigated focusing on vertical and horizontal distances from the building's corner.

Semi-Empirical Analysis of the Mass Transfer Characteristics of the Slug Flow in Vertical Mesoscale Tubes (작은 수직관을 흐르는 슬러그 유동의 물질전달 특성에 대한 반경험적 해석)

  • Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.366-374
    • /
    • 2014
  • Experimental mass transfer data, which were obtained for the $CO_2$-water slug flows in vertical tubes with 2, 5, and 8mm diameters, were analyzed in comparison with the penetration theory. It was found that a penetration model with molecular diffusion coefficient cannot predict the experimental data accurately. An effective diffusion coefficient, which considers enhancement effect of interfacial waves, was suggested to improve prediction. Another empirical factor was also suggested to consider the effect of non-uniform interface velocity. A modified penetration model was found to be capable of predicting the experimental data reasonably well.

Observation of saturation transfer characteristics in solution processed vertical organic field-effect transistors (VOFETs) with high leakage current

  • Sarjidan, M.A. Mohd;Shuhaimi, Ahmad;Majid, W.H. Abd.
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1415-1421
    • /
    • 2018
  • Unlike ordinary organic field-effect transistors (OFETs), saturation current is hardly to be found in vertical OFETs (VOFETs). Moreover, the fabrication process of patterned sourced for VOFETs is quite complex. In this current work, a simple solution processed VOFET with directly deposited intermediate silver source electrode has been demonstrated. The VOFET exhibits a high leakage current that induces an inversion polarity of its transistor behavior. Interestingly, a well-defined saturation current was observed in the linear scale of transfer characteristic. The VOFET operated with high-current density > $280mA/cm^2$ at $V_d=5V$. Overview potential of the fabricated device in display application is also presented. This preliminary work does open-up a new direction in VOFET fabrication and their application.

Primary xanthoma inferior to the right mandibular third molar and intraoral vertical ramus osteotomy

  • Kim, Min-Ji;Kang, Min-Jun;Kang, Sang-Hoon
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.231-238
    • /
    • 2022
  • Intraosseous xanthoma of the mandible is a rare benign disorder. A 17-year-old male patient presented with a suspected abscess in the right mandibular third molar, detected on a panoramic radiograph. The patient had no history of systemic or lipid-related metabolic diseases and complained of no specific symptoms or pain. A radiographic examination revealed a heterogeneous radiolucency extending from the apical to the distal aspect of the right mandibular third molar tooth germ. The lesion measured 9 × 16 × 24 mm (antero-posterior × mediolateral × supero-inferior) and showed a relatively well-defined, multilocular, foamy appearance with hyperostotic borders spreading to the inferior alveolar nerve canal. After excisional biopsy, a diagnosis of central xanthoma was made. The lesion recurred, and intraoral vertical ramus osteotomy was done near the lesion. For the treatment of xanthoma of the mandible, extensive and delicate surgical treatment under general anesthesia should be considered.

Assessment of seismic load incident angle effects on structural integrity of a spent nuclear fuel dry storage facility (지진하중 입사각이 사용후핵연료 건식 저장시설의 구조건전성에 미치는 영향 분석)

  • Dong-Hyeon Kwak;Yoon-Suk Chang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.65-74
    • /
    • 2021
  • This study aims to assess the effect of postulated seismic loads on the structural integrity of a spent nuclear fuel dry storage facility. Firstly, three-dimensional modal and response spectrum analyses were carried out. With regard to the latter analysis, the effect of incident angles against two horizontal and one vertical response spectra was also considered. Results showed that even though two critical locations were predicted at the longitudinal axis central part of upper flow path as well as the end discontinuity part of upper and lower flow paths connector, their maximum principal stress values were less than the tensile strength. Moreover, since the influence of vertical angle was 87% higher than that of horizontal angle in particular, which should be carefully handled to demonstrate integrity of the facility.

Disposal Characteristics of Dredged Material from the Hopper Dredger (호퍼준설선의 투기특성)

  • Jeong, D.D.;Lee, J.W.
    • Journal of Korean Port Research
    • /
    • v.11 no.2
    • /
    • pp.203-214
    • /
    • 1997
  • Hydraulic dredgers(Hopper dredger) are the most important piece of equipment in the entire harbor engineering field, and most suitable for the removal of sand and weakly consloidated sediment such as silt. In maintenance dredging, specially confined harbor or congested passage area, Hopper dredger is user most popularly because less obstruction and danger to navigation than other mostly stationary dredgers. Investigation of the physical behave of dredged material disposal in coastal water from the Hopper dredger includes estimations of pattern as well as thickness of material on the bottom. Calculation based on vertical settling and horizontal advection of single particles ignore the effects of bulk properties of the disposed marterial, vertical and horizontal diffusion. and material dilution due to the entrainment of ambient water during descent. This paper focuses on the analysis of dredging and dumping characteristics and the spatial and temporal changes in the dumping fields for the water column and bottom at a hypothetically confined coastal water. This model accounts the behavior of material after release from the hopper dredger. It is shown that the model describes the qualitative feature of prototype dumping process and its response.

  • PDF

Two-fluid modelling for poly-disperse bubbly flows in vertical pipes: Analysis of the impact of geometrical parameters and heat transfer

  • Andrea Allio ;Antonio Buffo ;Daniele Marchisio;Laura Savoldi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1152-1166
    • /
    • 2023
  • The bubbly flow of air or steam in subcooled water are investigated here in several test cases, characterized by different pipe sizes, bubble dimensions and flow rates, by means of CFD using a Eulerian-Eulerian approach. The performance of models that differ for the turbulence closure in the continuous phase, as well as for the description of the lift force on the dispersed phase, are compared in detail. When air is considered, the space of the experimental parameters leading to a reasonable performance for the selected models are identified and discussed, while the issues left in the modelling of the concurrent condensation are highlighted for the cases where steam is used.

Full mouth rehabilitation in a severe worn dentition with vertical dimension gaining: A case report (마모가 심한 환자에서 수직 고경 증가를 동반하여 수복한 증례)

  • Kim, Ji-Sun;Lee, Ji-Hyoun;Jhin, Min-Ju
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.132-139
    • /
    • 2016
  • The progressive attrition of teeth is a normal process by aging. However, excessive tooth wear with decreased vertical dimension of occlusion and collapse of occlusal plane may cause pathologic pulpal condition, occlusal disharmony, functional disorders and esthetic problems. The change of vertical dimension is required in case that there is no sufficient clearance for restoration or in case that the occlusal relationship is modified. For gaining the vertical dimension, a careful diagnosis is essential prior to starting the restoration treatment. After evaluating adaptation of neuromuscular system of patient during provisional phase, the final restorations can be fabricated. In this case, a 78 year old male with severely worn down dentition was treated. To improve the esthetic appearance and to achieve the ideal occlusal relationship, the full mouth rehabilitation with minimal increase of vertical dimension is planned and diagnostic wax-up was performed at the increased vertical dimension. After evaluation of provisional restorations for 12 weeks, final restorations were fabricated and routine clinical assessments were made. After 1 year, the restorations with newly established occlusal scheme are well maintained without significant complications and esthetically and functionally satisfactory results were obtained.

Analysis of PVD Degree of Consolidation with Various Core Types (코어형태에 따른 연직배수재의 압밀도 분석)

  • Shin, Eun-Chul;Kim, Sung-Hwan;Zhanara, Nazarova
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.4
    • /
    • pp.15-20
    • /
    • 2007
  • Recently, the demand for industrial and residental land are increasing with economic growth, but it is difficult to acquire areas for development with good ground condition. For efficient and balanced development of land, new development projects are being carried out not only the areas with inland but those with the soft ground as well. As soft grounds have complex engineering properties and high variations such as ground subsidence especially when their strength is low and depth is deep, we need to accurately analyze the engineering properties of soft grounds and find general measures for stable and economic design and management. Vertical drain technology is widely used to accelerate the consolidation of soft clay deposits and dredged soil under pre-loading and various types of vertical drain are used with there discharge capacity. Under field conditions, discharge capacity is changed with various reason, such as soil condition, confinement pressure, long-term clogging and folding of vertical drains and so on. Therefore, many researcher and engineer recommend the use of required discharge capacity. In this paper, the experiment study were carried out to obtain the discharge capacity of six different types of vertical drains by utilizing the large-scale model tests and discharge capacity, degree of consolidation with the time elapsed.

  • PDF