• Title/Summary/Keyword: Vertical Well

Search Result 1,908, Processing Time 0.032 seconds

Unilateral intraoral vertical ramus osteotomy based on preoperative three-dimensional simulation surgery in a patient with facial asymmetry

  • Lee, Jae-Won;Kim, Moon-Key;Kang, Sang-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • Preoperative surgical simulation in orthognathic surgery has progressed in recent years; the movement of the mandible can be anticipated through three-dimensional (3D) simulation surgery before the actual procedure. In this case report, the mandible was moved to the intended postoperative occlusion through preoperative surgical 3D simulation. Right-side condylar movement change was very slight in the surgical simulation, suggesting the possibility of mandibular surgery that included only left-side ramal osteotomy. This case report describes a patient with a mild asymmetric facial profile in which the mandibular menton had been deviated to the right and the lips canted down to the left. Before surgery, three-dimensional surgical simulation was used to evaluate and confirm a position for the condyle as well as the symmetrical postoperative state of the face. Facial asymmetry was resolved with minimal surgical treatment through unilateral intraoral vertical ramus osteotomy on the left side of the mandible. It would be a valuable complement for the reduction of the surgical treatment if one could decide with good predictability when an isolated intraoral vertical ramus osteotomy can be done without a compensatory osteotomy on the contralateral side.

Evaluation of seismic reliability and multi level response reduction factor (R factor) for eccentric braced frames with vertical links

  • Mohsenian, Vahid;Mortezaei, Alireza
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.537-549
    • /
    • 2018
  • Using vertical links in eccentric braced frames is one of the best passive structural control approaches due to its effectiveness and practicality advantages. However, in spite of the subject importance there are limited studies which evaluate the seismic reliability and response reduction factor (R-factor) in this system. Therefore, the present study has been conducted to improve the current understanding about failure mechanism in the structural systems equipped with vertical links. For this purpose, following definition of demand and capacity response reduction factors, these parameters are computed for three different buildings (4, 8 and 12 stories) equipped with this system. In this regards, pushover and incremental dynamic analysis have been employed, and seismic reliability as well as multi-level response reduction factor according to the seismic demand and capacity of the frames have been derived. Based on the results, this system demonstrates high ductility and seismic energy dissipation capacity, and using the response reduction factor as high as 8 also provides acceptable reliability for the frame in the moderate and high earthquake intensities. This system can be used in original buildings as lateral load resisting system in addition to seismic rehabilitation of the existing buildings.

Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses (초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가)

  • Kim, Young-Bae;Kim, Jae-Hong;Sung, Jae-Yong;Lee, Myeong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

An Experimental Study for Vertical Flame Spread Analysis of Aluminum Composite Panel (알루미늄 복합 패널의 수직 화염전파속도 분석을 위한 실험적 연구)

  • Kim, Il-Kwon;Kim, Bong-Chan;Ku, In-hyuck;Seo, Dong-Gu;Lim, Nam Gi;Kwun, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.315-317
    • /
    • 2013
  • To analyze vertical fire spreadability of aluminum composite panel, real scale test of aluminum composite panel and fire retardant aluminum composite panel was conducted as well as analysis of domestic code, test and domestic reaserch resulted in following conclusion. Fire spread risk assessment of aluminum Composite Panel is impossible with the current regulations (Cone Calorimeter Test). It need to changes of regulatory and combustion expanded risk assessment and regulatory changes in the test methods need to be judged. Also, there is quite a big different between the general aluminum Composite Panel and semi-non combustible of aluminum Composite Panel. However it is also deemed to be danger when present in the sidewall to the top consisting of fire spread. From now on, it is needed the study about interpretation of fire spread and sidewall of vertical fire spread analysis not only experiments for aluminum Composite Panel.

  • PDF

A Study on Dynamic Analysis of Vertical Mixed-Flow Pump for Nuclear Power Plants (원자력 발전소용 입형 사류펌프의 동적해석에 관한 연구)

  • Seo, Y.S.;Lim, W.S.;Chung, H.T.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.71-77
    • /
    • 2006
  • This study introduces the seismic qualification of safety related equipments for nuclear power plants to verify the possibility of resonance in regard to the operating speed and the structural integrity due to external piping nozzle loads as well as seismic dynamic loads using El-Centro earthquake, which was occurred in the 1940's previously. As a first step, it is necessary to investigate the natural frequency of the vertical mixed flow pump in order to determine whether static or dynamic equipment comparing with seismic cut-off frequency, 33hz. Also the normal mode analysis was carried out with the introduction of seismic redesign straint at the middle of vertical pump to increase the natural frequency. In terms of structural integrity, the application of static analysis with normal, upset and faulted nozzle loads event was presented for the comparison of material allowable stress. Also the dynamic analysis was performed to show the design adequacy through the application to the case of El-Centro earthquake.

  • PDF

Vertical isolation of a structure based on different states of seismic performance

  • Milanchian, Reza;Hosseini, Mahmood;Nekooei, Masoud
    • Earthquakes and Structures
    • /
    • v.13 no.2
    • /
    • pp.103-118
    • /
    • 2017
  • In vertical seismic isolation (VSI), a building is partitioned intentionally by vertical layers into two dynamically different substructures for seismic response reduction. Initially, a 1-story frame was partitioned into two substructures, interconnected by viscous and visco-elastic links, and seismic responses of the original and the vertically isolated structures (VIS) were obtained, considering a large number of stiffness and mass ratios of substructures with respect to the original structure. Color contour graphs were defined for presentation and investigation of large amounts of output results. Dynamic characteristics of the isolated structures were studied by considering the non-classical damping of the system, and then the effects of viscous and visco-elastic link parameters on the modal damping ratios were discussed. On this basis, three states of mass isolation, interactional state, and control mass were differentiated. Response history analyses were performed by Runge-Kutta numerical method. In these analyses, interaction of isolation ratios and link parameters, on response control of VIS was studied and the appropriate ranges for link parameters as well as the optimal ranges for isolation ratios were suggested. Results show that by using the VSI technique, seismic response reduction up to 50% in flexible substructure and even more in stiff substructure is achievable.

Seismic fragility analysis of RC frame-core wall buildings under the combined vertical and horizontal ground motions

  • Taslimi, Arsam;Tehranizadeh, Mohsen;Shamlu, Mohammadreza
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.175-185
    • /
    • 2021
  • This study strives to highlight the importance of considering the vertical ground motions (VGM) in the seismic evaluation of RC buildings. To this aim, IDA (Incremental Dynamic Analysis) is conducted on three code-based designed high-rise RC frame-core wall buildings using a suite of earthquake records comprising of significant VGMs. To unravel the significance of the VGM inclusion on the performance of the buildings, IDAs are conducted in two states (with and without the vertical component), and subsequently based on each analysis, fragility curves are developed. Non-simulated collapse criteria are used to determine the collapse state drift ratio and the area under the velocity spectrum (SIm) is taken into account as the intensity measure. The outcome of this study delineates that the inclusion of VGM leads to the increase in the collapse vulnerability of the structures as well as to the change in the pattern of inter-story drifts and failure mode of the buildings. The results suggested that it would be more conservative if the VGM is included in the seismic assessment and the fragility analysis of RC buildings.

Wave Forces Acting on Vertical Cylinder and Their Wave Transformations by 3-Dimensional VOF Method (3차원 VOF법에 의한 연직 주상구조물에 작용하는 파력과 구조물에 의한 파랑변형 해석)

  • Lee, Kwang-Ho;Lee, Sang-Ki;Sin, Dong-Hoon;Kim, Chang-Hoon;Kim, Do-Sam
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.2 s.75
    • /
    • pp.12-21
    • /
    • 2007
  • As the economy grows and the population increases, we need to develop our coastal area and make use of it for various purposes. Specifically, investigation of the wave interactions on and around the vertical cylinders is very important in the design of the offshore or coastal structures. The nonlinear potential analysis developed so far, although very useful, has been found to be limited in application, as strong nonlinear waves generated by the interference between multilayered cylinders and wave impact forces by breaking waves can hardly be estimated. In this study, using a 3-Dimensional volume tracking method VOF(Volume of Fluid), based on Namer-Stokes equations, was developed to simulate highly nonlinear effects, such as breaking waves at the interface or complicated interference waves among structures. A numerical method for nonlinear interaction wave and vertical cylinders is newly proposed. The wave forces and wave transformations computed by the newly proposed numerical simulation method were compared to the other researcher's experimental results, and the results agree well. Based on the validation of this study, this numerical method is applied to the two vertical cylinders to discuss their nonlinear wave forces and wave transformations, according to the variations of separate distance of vertical cylinders.

The Effects of Size and Array of N-GaN Contacts on Operation Voltage of Padless Vertical Light Emitting Diode (N-GaN 접촉 전극의 크기 및 배열 변화에 따른 패드리스 수직형 발광다이오드의 구동전압의 변화에 관한 연구)

  • Rho, Hokyun;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.1
    • /
    • pp.19-23
    • /
    • 2014
  • For the application of light-emitting diodes (LEDs) for general illumination, the development of high power LEDs chips became more essential. For these reasons, recently, modified vertical LEDs have been developed to meet various requirements such as better heat dissipation, higher light extraction and less cost of production. In this research, we investigate the effect of Size and Array of N-GaN contact on operation voltage with new structured padless vertical LED. We changed the size and array of N-electrodes and investigated how they affect the operation voltage of LEDs. We simulated the current crowding and expected operation voltage for different N-contact structures with commercial LED simulator. Also, we fabricated the padless vertical LED chips and measured the electrical property. From the simulation, we could know that the larger size and denser array of n-electrodes could make operation voltage decrease. These results are well in accordance with those measured values of real padless vertical LED chips.

Vertical equipment isolation using piezoelectric inertial-type isolation system

  • Lu, Lyan-Ywan;Lin, Ging-Long;Chen, Yi-Siang;Hsiao, Kun-An
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.195-211
    • /
    • 2020
  • Among anti-seismic technologies, base isolation is a very effective means of mitigating damage to structural and nonstructural components, such as equipment. However, most seismic isolation systems are designed for mitigating only horizontal seismic responses because the realization of a vertical isolation system (VIS) is difficult. The difficulty is primarily due to conflicting isolation stiffness demands in the static and dynamic states for a VIS, which requires sufficient rigidity to support the self-weight of the isolated object in the static state, but sufficient flexibility to lengthen the isolation period and uncouple the ground motion in the dynamic state. To overcome this problem, a semi-active VIS, called the piezoelectric inertia-type vertical isolation system (PIVIS), is proposed in this study. PIVIS is composed of a piezoelectric friction damper (PFD) and a leverage mechanism with a counterweight. The counterweight provides an uplifting force in the static state and an extra inertial force in the dynamic state; therefore, the effective vertical stiffness of PIVIS is higher in the static state and lower in the dynamic state. The PFD provides a controllable friction force for PIVIS to further prevent its excessive displacement. For experimental verification, a shaking table test was conducted on a prototype PIVIS controlled by a simple controller. The experimental results well agree with the theoretical results. To further investigate the isolation performance of PIVIS, the seismic responses of PIVIS were simulated numerically by considering 14 vertical ground motions with different characteristics. The responses of PIVIS were compared with those of a traditional VIS and a passive system (PIVIS without control). The numerical results demonstrate that compared with the traditional and passive systems, PIVIS can effectively suppress isolation displacement in all kinds of earthquake with various peak ground accelerations and frequency content while maintaining its isolation efficiency. The proposed system is particularly effective for near-fault earthquakes with long-period components, for which it prevents resonant-like motion.