Journal of Power System Engineering (동력기계공학회지)
- Volume 10 Issue 4
- /
- Pages.71-77
- /
- 2006
- /
- 2713-8429(pISSN)
- /
- 2713-8437(eISSN)
A Study on Dynamic Analysis of Vertical Mixed-Flow Pump for Nuclear Power Plants
원자력 발전소용 입형 사류펌프의 동적해석에 관한 연구
Abstract
This study introduces the seismic qualification of safety related equipments for nuclear power plants to verify the possibility of resonance in regard to the operating speed and the structural integrity due to external piping nozzle loads as well as seismic dynamic loads using El-Centro earthquake, which was occurred in the 1940's previously. As a first step, it is necessary to investigate the natural frequency of the vertical mixed flow pump in order to determine whether static or dynamic equipment comparing with seismic cut-off frequency, 33hz. Also the normal mode analysis was carried out with the introduction of seismic redesign straint at the middle of vertical pump to increase the natural frequency. In terms of structural integrity, the application of static analysis with normal, upset and faulted nozzle loads event was presented for the comparison of material allowable stress. Also the dynamic analysis was performed to show the design adequacy through the application to the case of El-Centro earthquake.
Keywords