• Title/Summary/Keyword: Vertical Distraction

Search Result 32, Processing Time 0.022 seconds

Effect of Chitosan-Calcium Sulfate Mixture on Early Bony Consolidation in Osteodistracted Dogs (개의 골신연술에서 키토산과 황화칼슘합제가 조기 골경화에 미치는 영향)

  • 강원모;장광호;장인호
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.165-173
    • /
    • 2002
  • The purpose of this study was to evaluate the effect of chitosan-calcium sulfate mixture on early bony consolidation in osteodistracted dogs. The experimental group was divided into 3 groups: saline group(Control), chitosan group(Group CH) and chitosan-calcium sulfate mixture group(Group CH+CS). Four dogs were allocated to each group and classified into B week observation subgroups and 5 week observation subgroups, respectively. Two dogs were allocated to each subgroup. The lateral surface of the left mandibular body was exposed in the subperiosteal plane and vertical osteotomy was carried out on the mandibular body. An external distraction device was applied to the mandibular body. Mandibular distraction was started 5 days after the osteotomy at a rate of 1 m per day for a total of 10 w distraction for 10 days. After completion of distraction, chitosan, chitosan-calcium sulfate and saline were injected into the distracted zone of the group CH, group CH+CS and control. The external device was left in place for 3 or 5 weeks to allow for bony consolidation. Serial radiographs were carried out every week. Two dogs of each group, six dogs in total, were sacrificed at 3 weeks, and the other six dogs at 5 week after distraction. Bone specimens of the distracted mandibles were taken for histologic examination. New bone was not noted in the distracted zone of 3 week observation subgroups in the control and group CH. However, new bone was developed in the group CH+CS with a narrow fibrous interzone in the area of the distracted zone. While osteogenesis was mild in the margin of the distracted Bone of 5 week observation subgroup in the control, new bone was noted much in the group CH and group CH+CS. However, osteogenesis was noted more significantly in the group CH+CS than that of group CH. In conclusion, chitosan-calcium sulfate mixture was more effective on early bony consolidation in distraction osteogenesis

VERTICAL DISTRACTION OSTEOGENESIS FOR IMPLANT INSTALLATION ON THE RECONSTRUCTED MANDIBLE WITH FREE FIBULAR FLAP (하악골 재건시 사용된 유리비골피판에서 임플란트 식립을 위한 수직적 골신장술)

  • Paeng, Jun-Young;Lee, Jin-Yong;Myoung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.579-585
    • /
    • 2006
  • Introduction: The fibular free flap is now considered as the first choice for long mandibular discontinuity defect. In spite of its good bone quality for implant installation, its diameter is too narrow to rehabilitate the masticatory function with implant installation. In this report, distraction osteogenesis was used for the augmentation of bone to install the dental implant in the mandible which was reconstructed with a vascularized fibular free flap. Patients and Methods: Three patients undertook the vertical augmentation of grafted fibular bone and dental implants were installed. On the day 8 post-surgery, the activation of the distractor was started at the rate of 1 mm twice a day. The total amount of distraction was 15 mm in two patients and 12.5 mm in one patient. Twelve implants were installed in three patients. Dental implants were simultaneously installed during removal of the distraction device in two patients. In one patient, the implant installation was delayed after device had been removed. All three patients showed the symptoms of mild to severe postoperative infection during the activation and consolidation. However, the distracted site showed undisturbed bone regeneration. Conclusion: The distraction osteogenesis showed the reliable results for the vertical augmentation of fibular bone which was used for the mandibular reconstruction. However, the great tendency of postoperative infection must be considered and clinically controlled.

Maxillary Anterior Segmental Distraction with Rigid External Device: Case Report (구순구개열환자의 상악 전방분절 골신장술식을 이용한 교정 치험례)

  • Yoo, Seong-Hun;Choi, Hye-Young;Yu, Hyung-Seog;Baik, Hyoung-Seon;Cha, Jung-Yul
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.14 no.1_2
    • /
    • pp.19-28
    • /
    • 2011
  • Maxillary anterior segmental distraction osteogenesis (DO) has been the alternative treatment option for patients with midfacial retrusion. The patient showed unilateral cleft lip and palate, and premaxillary distraction with rigid external device (RED) was planned to solve midface deficiency and to create alveolar space. Significant advancement of A point was observed, but relapse of A point was detected during consolidation period. The vertical position of the ANS was found to have moved downward. Axis of upper incisor decreased after DO. Maxillary anterior segmental DO is effective for treatment of patient with cleft lip and palate. The alveolar space is regained successfully, and the facial profile is improved without velopharyngeal problems.

  • PDF

EFFECT OF PULSED ELECTROMAGNETIC FIELD STIMULATION ON THE EARLY BONE CONSOLIDATION AFTER DISTRACTION OSTEOGENESIS IN RABBIT MANDIBLE MODEL (가토 하악골 골신장 후 맥동전자기장이 조기 골경화에 미치는 효과에 대한 연구)

  • Hwang, Kyung-Kyun;Cho, Tae-Hyung;Song, Yun-Mi;Kim, Do-Kyun;Han, Sung-Hee;Kim, In-Sook;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.2
    • /
    • pp.123-131
    • /
    • 2007
  • Introduction: Distraction osteogenesis is widely used as for bone lengthening in patients with maxillofacial deformity and alveolar bone atrophy. One of the major problems in distraction osteogenesis is long consolidation period for 2-3 months, in which the devices have to be fixed on the bone to prevent relapse. It results in scar formation on the face, disturbance of mastication and speech. This study was performed to evaluate the stimulating effect of pulsed electromagnetic field on the early bone consolidation in distraction osteogenesis. Materials and methods: Total 10 rabbit were used (5 for control group, 5 for experimental group). A vertical osteotomy in the mandibular body was performed and the distraction device was fixed. After 5 days distraction was done 1mm per a day for 7 days. A pulsed electromagnetic field (38 Gauss, 60 Hz) was applied for 8 hours per day and it continued for 5 days immediately after distraction in the experimental group. Both groups were sacrificed after 2 weeks. Histological specimens with H&E and Masson Trichrome staining were made and histomorphometrically analysed with image analyser. Results: The device for distraction osteogenesis was displaced in one animal for each group, therefore, only four animals in both groups were evaluated. In both groups, a new bone formation was observed in the distracted area after 2 weeks. The bone formation was enhanced in the experimental groups ($31.76{\pm}8.68%$) compared with control group ($9.94{\pm}3.23%$), its difference was statistically significant (p<0.001). Conclusion: This study suggests that electrical stimulation with electromagnectic field may be effective in the early bone formation after distraction osteogenesis. Further studies with large number of animals are needed before clinical application.

A 3-D finite element analysis on the mandibular movement pattern and stress distribution during symphyseal widening (하악 이부확장 시 하악골 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Lee, Do-Hoon;Hong, Hyun-Sil;Chae, Jong-Moon;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.13-30
    • /
    • 2008
  • Objective: The objective of this study was to evaluate the displacement pattern and the stress distribution of the finite element model 3-D visualization during symphyseal widening according to the osteotomy position, osteotomy type, and distraction device. Methods: The kinds of distraction devices used were tooth-borne type, hybrid type, bone-borne type and tooth-borne type $30^{\circ}$ angulated, and the kinds of osteotomy design were vertical osteotomy line between the central incisors and step osteotomy line through the symphysis. Results: All reference points of the mandible including the condyles were displaced laterally irrespective of the osteotomy position, osteotomy method and distraction device. The anteroposterior or vertical displacements showed small differences between the groups. The widening pattern of the osteotomy line in the tooth-borne type of device was v shaped, and that of bone-borne type was a reverse v shape. However, the pattern in the hybrid type was parallel. The lateral displacement of the mandibular angle by the bone-borne device was more remarkable than the other types of devices. The displacement by the $30^{\circ}$ angulated tooth-borne type was different between the left and right sides in both the transverse and anteroposterior aspects. Conclusion: The design of the distraction devices and osteotomy line can influence the displacement pattern and the stress distribution during mandibular symphyseal distraction osteogenesis procedures.

EFFECTS OF COMPRESSION ON DISTRACTED AREA DURING MANDIBULAR DISTRACTION IN RABBITS (가토에서 하악골신장술시 신장부에 대한 가골압축의 효과)

  • Park, Hong-Ju;An, Jin-Suk;Kook, Min-Suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Cho, Jin-Hyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • Purpose: To evaluate the effect of compression on the distracted area in new bone formation during mandibular distraction osteogenesis in rabbits. Materials and method: Sixteen rabbits, weighing approximately 2 Kg, and the prefabricated distraction device were used. With the rabbits under general anesthesia, we performed vertical osteotomies between the anterior and posterior mandibular teeth and then placed the distraction device. After a 5 -day latency period, the mandible was distracted to a length of 10.0 mm at a rate of 1 mm/day and then immediately compressed 4 mm in the experimental group (n=8). In the control group (n=8), the mandible was distracted to a length of 6.0 mm at a rate of 1 mm/day. Rabbits in the control group were killed at 2 and 8 weeks during the consolidation period. The specimens were evaluated with light microscope after H & E stain. Histomorphometric analysis was done at 8 week specimens. Results: All experimental animals showed mandibular elongation on the macroscopical and radiographic evaluations. At 2 week, immature bone formation was observed from the surface of the host bone margins with collagen fibers arranged parallel to the direction of distraction in the control group; in the experimental group, immature bone formation was observed adjacent to the host bone, and the collagen fibers were not arranged uniformly. At 8 week, spindle-shaped new bone formation was seen in the direction of distraction in distracted area of the control group, while in the experimental group, the newly formed bone was arranged in a multidirectional manner, like the pattern of trabeculae. In the histomorphometric analysis of 8 weeks, the area of bone deposition was $2.12{\pm}\;0.75\;inch^2$ in the experimental group and $0.87{\pm}0.51\;inch^2$ in the control group (p<0.01). The bone deposition ratio was $29.60{\pm}10.50%$ in the experimental group and $12.10{\pm}7.17%$ in the control group (p<0.01). Conclusion: These results suggest that compression after over-distraction during the mandibular distraction osteogenesis is an effective method of increasing the amount of newly formed bone in distracted area.

EFFECTS OF OSSEOINTEGRATION ACCORDING TO IMPLANT PLACEMENT TIMING IN THE DISTRACTED ALVEOLAR BONE OF DOGS (치조골 신연 후 임프란트 매식 시기에 따른 골유착 효과)

  • Jung, Hyun;Oh, Hee-Kyun;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.3
    • /
    • pp.238-244
    • /
    • 2000
  • The present study was aimed to investigate the effect of osseointegration according to implant placement timing in the distracted alveolar bone using intraoral distraction device. Six adult mongrel dogs of either sex, weighing about 15kg, were used. The animals were divided into 4-week and 8-week groups according to the timing of implant installation. The left upper and lower premolars and first molars were extracted and an alveoloplasty was performed to simulate an atrophic ridge. After 12 weeks of healing, a segmental osteotomy was made and an intraoral distraction device which was designed for augmentation of vertical height of the edentulous ridge was applied. Latency period was allowed for 5 days and then distraction was made at a rate of 1.2mm/day for 8 days. Four or eight weeks after distraction, implants were installed. Twelve weeks after implant installation, the animals were sacrificed. Macroscopic, radiographic, and histologic examinations of distracted alveolar ridge were performed. No significant abnormalities such as infection and dehiscence of overlying soft tissue were observed. Radiographically, there was slight bone resorption around the medial and distal edges of the alveolar bone segment, and a new bone deposition was observed in the neighboring alveolar crest area in the both groups. The satisfactory osseointegration was achieved in the distracted gap of the both groups, but fibrous tissue appeared on the buccal side of implant in the distracted gap in 4-week group. These results suggest that proper timing of implant installation is 8 weeks rather than 4 weeks after distraction when dental implant is to be placed onto the distracted bone.

  • PDF

A STUDY ON THE VERTICAL AUGMENTATION OF THE ALVEOLAR RIDGE BY DISTRACTION OSTEOGENESIS IN DOGS (성견에서 치조골 신장술을 이용한 수직적 골 증강에 관한 연구)

  • Lee, Joo-Ho;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.107-118
    • /
    • 2007
  • Statement of problem: Implant-type distractor uses a removable distraction device that has an appearance similar to that of a dental implant and utilizes many of the same techniques for placement as are used for dental implants. Material and method: In this study, 48 implant type titanium distractors were inserted into the osteotomized alveolar bone of 12 beagle dogs. After a 7-day latency period, the alveolar bone was augmented by 5mm vertically at a rate of 1.0 mm/day. The dogs were sacrificed after 4weeks, 8weeks and 12 weeks for radiographic, histologic, and histomorphometric analysis. Result: Copper equivalent value showed significant difference between 4 weeks and the other weeks(8, 12 weeks)(p<0.05). But there was no significant difference between maxillary and mandibular groups. In the bone to metal contact analysis, there was a significant difference between 4 weeks and 12 weeks(p<0.05). On the contrary, there was no significant difference between maxilla and mandible. The bone area showed significantly higher values in 12 weeks compared to 4 weeks(p<0.05). Histologically mineralization began at the host bone margins. At 12 weeks, increasing accumulation of $Ca^{++}$ element was confirmed. Conclusion: From the results above, the new bone formation was increased according to consolidation period. Especially there was significant difference between 4 weeks and 12 weeks(p<0.05). Implant type distractors used in this study to augment vertical ridge defect may prove to be a clinically useful treatment option in selected cases.

A case report about the reconstruction procedures of the previously failed cylinderical implants site using distraction osteogenesis

  • Lee, Jung-Tae;Park, Shin-Young;Yi, Yang-Jin;Kim, Young-Kyun;Lee, Hyo-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.2
    • /
    • pp.84-89
    • /
    • 2015
  • We report the eventually successful treatment of a huge bone defect and peri-implantitis following reconstruction of a previously failed intra-mobile cylinder implant system (IMZ) implant site using distraction osteogenesis (DO). In the anterior mandible, two IMZ implants failed and surgical debridement was performed in accordance to the patient's needs. Thereafter, mobility and suppuration were decreased and the patient visited the dental clinic on a regular basis for oral health maintenance. However, the inflammation did not resolve, and the bone destruction around the implants progressed for 4 years. Finally, the implants failed and a severe bone defect remained after implant removal. To reconstruct the bone defects, we attempted bone graft procedures. Titanium mesh was unsuccessfully used to obtain bone volume regeneration. However, DO subsequently was used to obtain sufficient bone volume for implant placement. The new implants were then installed, followed by prosthetic procedures. In conclusion, progression of peri-implantitis could not be arrested despite surgical intervention and repeated maintenance care for 3 years. Reconstruction of the peri-implantitis site was complicated due to its horizontal and vertical bone defects. Lesions caused by implant failure require an aggressive regenerative strategy, such as DO. DO was successful in reconstruction of a peri-implantitis site that was complicated due to horizontal and vertical bone defects.