Calibration Kit for 4-Port Horizontal/Vertical Probing (4-포트 수평/수직 겸용 프로브용 교정키트)

  • Kim, Taeho;Kim, Jonghyeon;Kim, Sungjun;Kim, Kwangho;Pu, Bo;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.559-575
    • /
    • 2014
  • In this paper, we propose a horizontal/vertical calibration kit for calibrating a vector network analyzer(VNA) to measure the vertical connector pin. If the conventional calibration kit is used, we should change the arm for a probe or need an assistant device and it takes a long time. In addition there is a risk of precision degradation caused by the position change of the probe tip sensitive to the surroundings. We suggest a 4-port vertical calibration kit to make up for the aforementioned shortcomings. The calibration kit was manufactured for the SOLT calibration method. 'Short', 'Open', and 'Load' are available in the horizontal plane, 'Thru' is available not only in the horizontal plane on the two planes of a PCB, but in the vertical plane between the two planes according to the positions of the probes. We complemented the conventional calibration kit to make a vertical calibration kit to be used for the vertical measurement method. We compared and analysed their reflection/transfer characteristics of the SOLT calibration standards of the proposed calibration kit and conventional one, we get a ${\pm}0.1$ dB differences of transfer characteristics in the range from 300 kHz to 8.5 GHz. In order to demonstrate usefulness, and we performed a case study for horizontal and vertical cases, and compared the results of the proposed calibration kit and conventional one.

Relationship between vertical components of maxillary molar and craniofacial frame in normal occlusion: Cephalometric calibration on the vertical axis of coordinates

  • Han, Ah-Reum;Kim, Jongtae;Yang, Il-Hyung
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.15-22
    • /
    • 2021
  • Objective: The aim of this study was to evaluate the correlation between the vertical position of maxillary first molar and vertical skeletal measurements in lateral cephalograms by using new linear measurements on the vertical axis of coordinates with calibration. Methods: The vertical position of maxillary first molar (U6-SN), and the conventionally used variables (ConV) and the newly derived linear variables (NwLin) for vertical skeletal patterns were measured in the lateral cephalograms of 103 Korean adults with normal occlusions. Pearson correlation analyses and multiple linear regression analyses were performed with and without calibration using the anterior and posterior cranial base (ACB and PCB, respectively) lengths to identify variables related to U6-SN. Results: The PCB-calibrated statistics showed the best power of explanation. ConV indicating skeletal hyperdivergency was significantly correlated with U6-SN. Six NwLin regarding the position of palatal plane were positively correlated with U6-SN. Each multiple linear regression analysis generated a two-variable model: sella and nasion to palatal plane. Among the three models, the PCB-calibrated model yielded highest adjusted R2 value, 0.880. Conclusions: U6-SN could be determined by the vertical position of the maxilla, which could then be used to plan the amount of molar intrusion and estimate its clinical stability. Cephalometric calibration on the vertical axis of coordinates by using PCB for vertical linear measurements could strengthen the analysis itself.

Calibration of Structured Light Vision System using Multiple Vertical Planes

  • Ha, Jong Eun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.438-444
    • /
    • 2018
  • Structured light vision system has been widely used in 3D surface profiling. Usually, it is composed of a camera and a laser which projects a line on the target. Calibration is necessary to acquire 3D information using structured light stripe vision system. Conventional calibration algorithms have found the pose of the camera and the equation of the stripe plane of the laser under the same coordinate system of the camera. Therefore, the 3D reconstruction is only possible under the camera frame. In most cases, this is sufficient to fulfill given tasks. However, they require multiple images which are acquired under different poses for calibration. In this paper, we propose a calibration algorithm that could work by using just one shot. Also, proposed algorithm could give 3D reconstruction under both the camera and laser frame. This would be done by using newly designed calibration structure which has multiple vertical planes on the ground plane. The ability to have 3D reconstruction under both the camera and laser frame would give more flexibility for its applications. Also, proposed algorithm gives an improvement in the accuracy of 3D reconstruction.

On-Site vs. Laboratorial Implementation of Camera Self-Calibration for UAV Photogrammetry

  • Han, Soohee;Park, Jinhwan;Lee, Wonhee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.4
    • /
    • pp.349-356
    • /
    • 2016
  • This study investigates two camera self-calibration approaches, on-site self-calibration and laboratorial self-calibration, both of which are based on self-calibration theory and implemented by using a commercial photogrammetric solution, Agisoft PhotoScan. On-site self-calibration implements camera self-calibration and aerial triangulation by using the same aerial photos. Laboratorial self-calibration implements camera self-calibration by using photos captured onto a patterned target displayed on a digital panel, then conducts aerial triangulation by using the aerial photos. Aerial photos are captured by an unmanned aerial vehicle, and target photos are captured onto a 27in LCD monitor and a 47in LCD TV in two experiments. Calibration parameters are estimated by the two approaches and errors of aerial triangulation are analyzed. Results reveal that on-site self-calibration excels laboratorial self-calibration in terms of vertical accuracy. By contrast, laboratorial self-calibration obtains better horizontal accuracy if photos are captured at a greater distance from the target by using a larger display panel.

A Comparative Analysis between Rigorous and Approximate Approaches for LiDAR System Calibration

  • Kersting, Ana Paula;Habib, Ayman
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.6_2
    • /
    • pp.593-605
    • /
    • 2012
  • LiDAR systems provide dense and accurate topographic information. A pre-requisite to achieving the potential accuracy of LiDAR is having a proper system calibration, which aims at estimating all the systematic errors in the system measurements and the mounting parameters relating the different components. This paper presents a rigorous and two approximate methods for LiDAR system calibration. The rigorous approach makes use of the LiDAR equation and the system raw measurements. The approximate approaches utilize simplified LiDAR equations using some assumptions, which allow for less strict requirements regarding the raw measurements. The first presented approximate method, denoted as quasi-rigorous, assumes that we are dealing with a vertical platform (i.e., small pitch and roll angles). This method requires time-tagged point cloud and trajectory position data. The second approximate method, denoted as simplified, assumes that we are dealing with parallel strips, vertical platform, and minor terrain elevation variations compared to the flying height above ground. Such method can be performed using the LiDAR point cloud only. Experimental results using a real dataset, whose characteristics deviate to some extent from the utilized assumptions in the approximate methods, are presented to provide a comparative analysis of the outcome from the introduced methods.

A Study on improving the Reliability of Thrust Measurement System (추력측정장치의 신뢰도 향상 방안에 관한 연구)

  • Kang, Donghyuk;Joo, Seongmin;Kim, Jong-gyu;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1188-1191
    • /
    • 2017
  • Thrust is one of the crucial performance parameter of a combustion chamber in the combustion chamber development test. So it is very important to measure an accurate thrust. Thrust calibration test was performed to identify the system characteristics, resistance and linearity of a vertical thrust measurement system(TMS) for accurate thrust measurement. It has been found 6.9% ~ 8.6% errors between the measured thrust by TMS calibration equations and theoretical thrust. It has been confirmed that the TMS calibration is necessary to be performed with the propellant lines connected to the combustion chamber for accurate thrust measurement.

  • PDF

Comparison of Calibration Methods of Phase Center Variations for Precise GPS Monument Positioning (정확한 GPS 기준국 좌표산출을 위한 위상중심 변동량 계산방법 비교)

  • Won Ji-Hye;Park Kwan-Dong;Ha Ji-Hyun;Kim Sang-Ho
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.9-14
    • /
    • 2006
  • A determinated position with GPS (Global Positioning System) data processing is the position of the phase center of a GPS antenna. The phase center of a GPS antenna is. not a stable point and depends on the azimuth and elevation angles of GPS satellites. It is known that the phase center variations (PCV) of a GPS antenna are greater in the vertical than the horizontal directions. The PCV calibration models for a GPS. antenna has two approaches: relative and absolute. In this study. we compared the two calibration models using the six operational permanent GPS stations in South Korea and analysed the PCV of each station. In addition, we. tested two different kinds of GPS antennas and compared the results. The accuracy and precision of the relative calibration was worse than the absolute calibration.

  • PDF

Preliminary Analysis of Data Quality and Cloud Statistics from Ka-Band Cloud Radar (Ka-밴드 구름레이더 자료품질 및 구름통계 기초연구)

  • Ye, Bo-Young;Lee, GyuWon;Kwon, Soohyun;Lee, Ho-Woo;Ha, Jong-Chul;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2015
  • The Ka-band cloud radar (KCR) has been operated by the National Institute of Meteorological Research (NIMR) of Korea Meteorological Administration (KMA) at Boseong National Center for Intensive Observation of severe weather since 2013. Evaluation of data quality is an essential process to further analyze cloud information. In this study, we estimate the measurement error and the sampling uncertainty to evaluate data quality. By using vertically pointing data, the statistical uncertainty is obtained by calculating the standard deviation of each radar parameter. The statistical uncertainties decrease as functions of sampling number. The statistical uncertainties of horizontal and vertical reflectivities are identical (0.28 dB). On the other hand, the statistical uncertainties of Doppler velocity (spectrum width) are 2.2 times (1.6 times) larger at the vertical channel. The reflectivity calibration of KCR is also performed using X-band vertically pointing radar (VertiX) and 2-dimensional video disdrometer (2DVD). Since the monitoring of calibration values is useful to evaluate radar condition, the variation of calibration is monitored for five rain events. The average of calibration bias is 10.77 dBZ and standard deviation is 3.69 dB. Finally, the statistical characteristics of cloud properties have been investigated during two months in autumn using calibrated reflectivity. The percentage of clouds is about 26% and 16% on September to October. However, further analyses are required to derive general characteristics of autumn cloud in Korea.

Study on the partially premixed flames produced by a coflow burner as temperature calibration source (동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구)

  • Park, Chul-Woung;Hahn, Jae-Won;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.160-167
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a coflow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.