• 제목/요약/키워드: Vertebral

검색결과 961건 처리시간 0.03초

Survey of Sonoanatomic Distances For Lumbar Medial Branch Nerve Blocks in Healthy Volunteers

  • Gharaei, Helen;Imani, Farnad;Solaymani-Dodaran, Masoud
    • The Korean Journal of Pain
    • /
    • 제27권2호
    • /
    • pp.133-138
    • /
    • 2014
  • Background: The precise knowledge of anatomy and the region of transverse process (TP) and superior articular processes (AP) and their distance from the skin are important in blocking and treating lumbar facet syndrome. Evaluation of these anatomic distances from 3rd and 5th lumbar vertebrae in both sides and in different body mass index (BMI) in healthy volunteers might improve knowledge of ultrasound (US) lumbar medial branch nerve blocks (LMBB). Methods: Bilateral US in the 3rd and 5th lumbar vertebrae of 64 volunteers carried out and the distance between skin to TP and skin to AP was measured. These distances were compared on both sides and in different BMI groups. The analysis was done using SPSS 11. Analysis of variance was used to compare the means at three vertebral levels (L3-L5) and different BMI groups. P values less than 0.05 were considered statistically significant. The paired t-test was used to compare the mean distance between skin to TP and skin to AP on both sides. Results: The distance between skin to TP and skin to AP of 3rd vertebrae to 5th vertebrae was increased in both right and left sides (P < 0.001) from up to down. The mean distance from skin to TP were greater on the left side compared to the right in all three vertebral levels from L3 to L5 (P values 0.014, 0.024, and 0.006 respectively). The mean distance from skin to TP and the skin to AP was statistically significant in different BMI groups (P < 0.001). Conclusions: We found many anatomic distances which may increase awareness of US guided LMBB.

An Assessment of Vertebral Left Atrial Size in Relation to the Progress of Myxomatous Mitral Valve Disease in Dogs

  • Kim, Sun Hwa;Seo, Kyoung Won;Song, Kun Ho
    • 한국임상수의학회지
    • /
    • 제37권1호
    • /
    • pp.9-14
    • /
    • 2020
  • Left atrial enlargement (LAE) is an important diagnostic factor in dogs with myxomatous mitral valve disease (MMVD). It is associated with the onset of congestive heart failure (CHF). Recently, a new radiographic left atrial measurement called vertebral left atrial size (VLAS) was introduced. This can be considered as a left atrial enlargement above 2.3. It appears to be related to the severity of MMVD. However, serial changes in VLAS in relation to disease progression and improvement in patients have yet to be studied. This study aims to assess the value of VLAS as a left atrial size monitoring indicator by examining correlations with VHS, LA/Ao ratio and LVIDDN, and comparing serial changes in dogs. A total of 126 dogs were studied with their owners' consent. The dogs were classified into four MMVD groups (Control, B1, B2, C-D) following the ACVIM Guideline by performing a physical examination, radiography and echocardiography. Besides, 24 and 17 dogs were reevaluated to compare values in relation to the progression and improvement of MMVD. VLAS showed significant increase according to the progress of the MMVD stage. This was the same in the Maltese breed group. A strong positive correlation was found between LVIDDN, VHS, LA/Ao ratio, and VLAS. The results of this study found VLAS to be significantly different according to left atrium size, and there was a correlation between disease progression and VLAS levels in each dog. Therefore, VLAS may be used to detect changes in left atrium size as an additional monitoring index of MMVD.

Parkinson's Disease as Risk Factor in Osteoporosis and Osteoporotic Vertebral Fracture : Prevalence Study Using National Inpatient Sample Database in Korea

  • Lee, Jin Yong;Lim, Nam Gu;Chung, Chun Kee;Lee, Jee-Young;Kim, Hyun Joo;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권1호
    • /
    • pp.71-82
    • /
    • 2019
  • Objective : To determine the prevalence of osteoporosis (OP) and osteoporotic vertebral fracture (OVF) in people with Parkinson's disease (PD) in Korea and its association with socioeconomic status. Methods : Using Health Insurance Review and Assessment Service-National Inpatient Sample (HIRA-NIS) data from 2009 to 2013, we estimated the annual prevalence of PD, OP, and OVF and investigated its association with socioeconomic status using data from National Health Insurance (NHI) beneficiaries and Medical Aid (MA) recipients. This study was supported by research funding from Korean Society for Bone and Mineral Research 2015. There were no study-specific biases related to conflicts of interest. Results : The number of PD patients in the HIRA-NIS increased each year from 2009 to 2013. Among patients with PD, the standardized prevalence rates of OP and OVF increased from 2009 to 2013; from 23.2 to 27.8 and from 2.8 to 4.2, respectively. Among patients with PD with OP, the prevalence of OVF were 12.2% and 15.1% in 2009 and 2013, respectively. The standardized prevalence rates of PD with OP and PD with OVF were significantly higher in MA recipients than in NHI beneficiaries. Conclusion : The prevalence of PD both with OP and with OVF increased and the prevalence was higher in MA recipients than in NHI beneficiaries. These findings may suggest that age over 65 years, female and low income may be a significant factor related to PD occurring with OP and OVF.

Adult Trauma Patients with Isolated Thoracolumbar Spinous and Transverse Process Fractures May be Managed Conservatively to Improve Emergency Department Throughput

  • Awad, Kyrillos;Spencer, Dean;Ramakrishnan, Divya;Pejinovska, Marija;Grigorian, Areg;Schubl, Sebastian;Nahmias, Jeffry
    • Journal of Trauma and Injury
    • /
    • 제34권1호
    • /
    • pp.31-38
    • /
    • 2021
  • Purpose: Traumatic vertebral injuries have a prevalence of 4-5% at level I centers. Studies have demonstrated that isolated thoracolumbar transverse process fractures (iTPF) rarely require brace or surgical interventions. We hypothesized that similarly isolated thoracolumbar spinous process fractures (iSPF) would have less need for bracing and operative interventions than SPFs with associated vertebral body (VB) fractures (SPF+VB). We performed a similar analysis for iTPF compared to transverse process fractures associated with VB injury (TPF+VB). Methods: In this single-center, retrospective study from 2012 to 2016, patients were classified into iSPF, SPF+VB, iTPF, and TPF+VB groups. Data including the fracture pattern, neurologic deficits, and operative intervention were obtained. The primary outcome studied was the need for bracing and/or surgery. A statistical analysis was conducted. Results: Of 98 patients with spinous process fractures, 21 had iSPF and 77 had SPF+VB. No iSPF patients underwent surgery, whereas 24 (31.17%) SPF+VB patients did undergo surgery (p=0.012). In the iSPF group, three patients (15%) received braces only for comfort, whereas 37 (48.68%) of the SPF+VB group required bracing (p=0.058). Of 474 patients with transverse process fractures, 335 had iTPF and 139 had TPF+VB. No iTPF patients underwent surgery, whereas 28 (20.14%) TPF+VB patients did (p≤0.001). Of the iTPF patients, six (1.86%) were recommended to receive braces only for comfort, while 68 (50.75%) of the TPF+VB patients required bracing (p<0.001). Conclusions: No patients with iSPF or iTPF required surgical intervention, and bracing was recommended to patients in these groups for comfort only. It appears that these injures may be safely managed without interventions, calling into question the need for spine consultation.

Fractal dimension analysis on CBCT scans for detecting low bone mineral density in postmenopausal women

  • Carvalho, Bruno Fontenele;de Castro, Julia Goncalves Koehne;de Melo, Nilce Santos;Figueiredo, Paulo Tadeu de Souza;Moreira-Mesquita, Carla Ruffeil;de Paula, Ana Patricia;Sindeaux, Rafael;Leite, Andre Ferreira
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.53-60
    • /
    • 2022
  • Purpose: The aim of this study was to compare the fractal dimension (FD) measured at 2 bone sites (second cervical vertebra and mandible) on cone-beam computed tomography (CBCT). The research question was whether FD could serve as an accessory tool to refer postmenopausal women for densitometric analysis. Therefore, the reliability and accuracy of FD were evaluated. Materials and Methods: In total, 103 postmenopausal women were evaluated, of whom 52 had normal bone mineral density and 51 had osteoporosis, according to dual X-ray absorptiometry of the lumbar spine and hip. On the CBCT scans, 2 regions of interest were selected for FD analysis: 1 at the second cervical vertebra and 1 located at the mandible. The correlations between both measurements, intra- and inter-observer agreement, and the accuracy of the measurements were calculated. A P value less than 0.05 was considered to indicate statistical significance for all tests. Results: The mean FD values were significantly lower at the mandibular region of interest in osteoporotic patients than in individuals with normal bone mineral density. The areas under the curve were 0.644 (P=0.008) and 0.531 (P=0.720) for the mandibular and vertebral sites, respectively. Conclusion: FD at the vertebral site could not be used as an adjuvant tool to refer women for osteoporosis investigation. Although FD differed between women with normal BMD and osteoporosis at the mandibular site, it demonstrated low accuracy and reliability.

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

Assessment of pharyngeal airway in Korean adolescents according to skeletal pattern, sex, and cervical vertebral maturation: A cross-sectional CBCT study

  • Elagib, Tassneem;Kyung, Hee-Moon;Hung, Bui Quang;Hong, Mihee
    • 대한치과교정학회지
    • /
    • 제52권5호
    • /
    • pp.345-353
    • /
    • 2022
  • Objective: To investigate airway volumes using cone-beam computed tomography (CBCT) by skeletal patterns, sex, and cervical vertebral maturation (CVM) stages in Korean adolescents. Methods: The sample consisted of pretreatment CBCT and cephalograms of 95 adolescents (aged 12-19) obtained out of 1,611 patients examined for orthodontic treatment from 2018 to 2020 in Kyungpook National University Dental Hospital. The samples were classified into two sex groups; three skeletal pattern groups, four chronological age groups and four CVM stages. Nasopharyngeal volumes (NPV), oropharyngeal volumes (OPV), total pharyngeal airway volume (TAV) and minimum cross-sectional area (MCA) measurements were taken from the CBCT. Multiple linear regression analyses to find out which one of the independent variables are good predictors for airway variables. Significant factors were analyzed by two-way multivariate analysis of variance (MANOVA) then multiple comparisons were analyzed using a t-test, and Fisher least significant difference. Results: Age, sex, CVM, and Sella-Nasion-B point have significant influence on airway variable. Males and females showed similar patterns of change in chronological age groups 1-3; however, males had larger NPV, OPV, and MCA at CVM in group 4. According to CVM stages, males had larger OPV, TAV, and MCA at CVM stage 6 (p-value: 0.019, 0.021, 0.015, respectively) and no sex differences at CVM stages 3, 4, and 5. Conclusions: Skeletal patterns have an effect on airway volume. Sex differences were found in CVM 6.

양식산 참조기(Larimichthys polyactis) (민어과) 자치어의 골격발달 (Osteological Development of Larvae and Juveniles of the Cultured Small Yellow Croaker Larimichthys polyactis (Sciaenidae))

  • 이강현;조정현;김진구
    • 한국수산과학회지
    • /
    • 제56권2호
    • /
    • pp.228-242
    • /
    • 2023
  • We examined the osteological development of the cranium, visceral skeleton, pectoral girdle, vertebral column, fins, and pterygiophore of small yellow croaker Larimichthys polyactis cultured at the Jeju Fisheries Research Institute. At 5.89 mm NL (notochord length), the larvae already had ossified frontal and basioccipital bones, parasphenoids, and vomer in the cranium. All elements of the visceral skeleton except the metapterygoid were ossified at 5.89 mm NL. Preorbital bone was ossified at 8.11 mm SL (standard length), and suborbital bones were ossified at 12.90 mm SL. In the vertebral column, ossification proceeded from the first to last centrum. The urostyle ossified at 7.41 mm SL. The caudal skeleton ossified at 6.78 mm NL, along with three hypural bones. In the pectoral girdle, the cleithrum, supracleithrum, postcleithrum, and post-temporal bones ossified at 5.89 mm NL. Caudal fin ossification began at 6.19 mm SL and was complete at 7.16 mm SL. Dorsal and anal fin ossification began at 7.16 mm SL and was complete at 8.62 mm and 8.11 mm SL, respectively. Anal and dorsal pterygiophore bone ossification was complete at 9.86 mm and 11.54 mm SL, respectively, and that of the supraneural bones was complete at 9.60 mm SL.

척추의 중심점과 Modified U-Net을 활용한 딥러닝 기반 척추 자동 분할 (Deep Learning-based Spine Segmentation Technique Using the Center Point of the Spine and Modified U-Net)

  • 임성주;김휘영
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권2호
    • /
    • pp.139-146
    • /
    • 2023
  • Osteoporosis is a disease in which the risk of bone fractures increases due to a decrease in bone density caused by aging. Osteoporosis is diagnosed by measuring bone density in the total hip, femoral neck, and lumbar spine. To accurately measure bone density in the lumbar spine, the vertebral region must be segmented from the lumbar X-ray image. Deep learning-based automatic spinal segmentation methods can provide fast and precise information about the vertebral region. In this study, we used 695 lumbar spine images as training and test datasets for a deep learning segmentation model. We proposed a lumbar automatic segmentation model, CM-Net, which combines the center point of the spine and the modified U-Net network. As a result, the average Dice Similarity Coefficient(DSC) was 0.974, precision was 0.916, recall was 0.906, accuracy was 0.998, and Area under the Precision-Recall Curve (AUPRC) was 0.912. This study demonstrates a high-performance automatic segmentation model for lumbar X-ray images, which overcomes noise such as spinal fractures and implants. Furthermore, we can perform accurate measurement of bone density on lumbar X-ray images using an automatic segmentation methodology for the spine, which can prevent the risk of compression fractures at an early stage and improve the accuracy and efficiency of osteoporosis diagnosis.

Accuracy of Thoracolumbar Spine K-Wire Placement in Toy, Small and Medium Breed Dogs: Novice Surgeons with 3D Printed Patient-Specific Guide versus an Experienced Surgeon with Freehand Techniques

  • Hwa-Joeng Shin;Hae-Beom Lee;Yoon-Ho Roh
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.294-301
    • /
    • 2022
  • Three-dimensional (3D) printing technique has been widely used for accurate screw and pin placement in orthopedic surgery and neurosurgery. However, there are few reports comparing the accuracy between the patient-specific guides and freehand Kirschner wire (K-wire) placement in toy, small and medium breed dogs. This study aimed to assess the accuracy of 3D printed patient-specific guides (PSGs) in pin insertion in the thoracolumbar vertebrae of toy breed dogs and compare the outcomes between novice and experienced surgeons. The experiment was conducted on the thoracolumbar vertebrae of 21 euthanized toy breed dogs (median weight, 5.95 kg). The optimal insertion angle placement was determined and patient-specific guides for K-wire insertion were designed and 3D printed using computed tomography (CT) and a 3D computer-aided design program of three vertebrae (Thoracic 12-Lumbar 1). K-wire tracts were made by experienced and novice surgeons and compared to assess the accuracy based on postoperative CT. Based on postoperative CT, in the experienced group, 61 out of 63 pins (96.8%) were fully contained inside the vertebral body and lamina, whereas two pins (3.2%) had perforated the vertebral canal (grade 3, 2-4 mm breach). However, all the pins in the novice group were fully contained. The use of 3D printed PSGs for pin insertion in the thoracolumbar region is an accurate and safe alternative to freehand screw placement by novice surgeons in toy, small and medium breed dogs. Operations with 3D printed PSGs allow novice surgeons to achieve better or similar outcomes in accurate placement of pin/screws in vertebrae.