Acute Pulmonary Thromboembolism: 14 Years of Surgical Experience

  • Park, Jiye;Lim, Sang-Hyun;Hong, You Sun;Park, Soojin;Lee, Cheol Joo;Lee, Seung Ook
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.78-84
    • /
    • 2019
  • Background: Pulmonary thromboembolism (PTE) is a life-threatening disease with high mortality. This study aimed to assess the outcomes of surgical embolectomy and to clarify the sustained long-term effects of surgery by comparing preoperative, postoperative, and long-term follow-up echocardiography outcomes. Of 22 survivors, 21 were followed up for a mean (median) period of $6.8{\pm}5.4years$ (4.2 years). Methods: We retrospectively reviewed 27 surgical embolectomy cases for massive or submassive acute PTE from 2003 to 2016. Immediate and long-term follow-up outcomes of surgical embolectomy were assessed on the basis of 30-day mortality, long-term mortality, postoperative complications, right ventricular systolic pressure, and tricuspid regurgitation grade. Results: The 30-day and long-term mortality rates were 14.8% (4 of 27) and 4.3% (1 of 23), respectively. Three patients had major postoperative complications, including hypoxic brain damage, acute kidney injury, and endobronchial b leeding, respectively (3.7% each). Right ventricular systolic pressure (median [range], mm Hg) decreased from 62.0 (45.5-78.5) to 31.0 (25.7-37.0, p<0.001). The tricuspid valve regurgitation grade (median [range]) decreased from 1.5 (0.63-2.00) to 0.50 (0.50-1.00, p<0.05). The improvement lasted until the last echocardiographic follow-up. Conclusion: Surgical embolectomy revealed favorable mortality and morbidity rates in patients with acute massive or submassive PTE, with sustained long-term improvements in cardiac function.

Effect of the Brain Death on Hemodynamic Changes and Myocardial Damages in Canine Brain Death Model -Electrocard iographic and Hemodynamic Changes in the Brain Death Model Induced by Gradual Increase of Intracranial Pressure- (잡견을 이용한 실험적 뇌사모델에서 뇌사가 혈역학적 변화와 심근손상에 미치는 영향 -제2보 : 뇌압을 점진적으로 증가시켜 유발한 뇌사모델의 심전도 및 혈역학적 변화-)

  • 조명찬;이동운
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • We developed an experimental model of brain death using dogs. Brain death was induced by increasing the intracranial pressure (ICP) gradually by continuous Infusion of saline through an epidural Foley catheter in 5 mongrel dogs (weight, 18~22kg). Hemodynamic and electrocardiographic changes were evaluated continuously during the process of brain death and obtained the following results. 1. The average volume and time required to induce brain death was 4.8$\pm$1.0ml and 143.0$\pm$30.9minutes respectively. 2. There was a steady rise of the ICP after starting the constant infusion of saline, and ICP rised continuously until the brain death (122.0$\pm$62.5mmHg). After reaching to the maximal value (125.0$\pm$47.7mmHg) at 30 minutes after brain death, the ICP dropped and remained approximately constant at the slightly higher level than the mean arterial pressure (MAP). 3. MAP showed no change until the establishment of brain death and it declined gradually. The peak heart rate reached to 172.6$\pm$35.3/min at 30 minutes after the brain death. 4. Even though the body temperature and all hemodynamic variables, such as cardiac output, mean pulmonary arterial pressure, left ventricular (LV) end-diastolic pressure and LV maximum + dp/dt, were slightly greater than those of basal state, at the point of brain death, there was no statistically significant change during t e process of brain death. 5. There was no remarkable arrhythmias during the experiment except ventricular premature beats which was observed transiently in one dog at the time of brain death. Hemodynamic changes in the brain death model induced by gradual ICP increment were inconspicuous, and arrhythmias were rarely seen. Hyperdynamic state, which was observed at the point of brain death in another brain death model caused by abrupt ICP increase, was not observed.

  • PDF

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

Surgical Experience of Idiopathic Hypertrophic Subaortic Stenosis - Report of A case - (특발성 비후성 대동맥판하 협착증의 수술적 치험 1례 보)

  • 강경훈
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.610-618
    • /
    • 1987
  • A 23-y-o male patient was suffered from intermittent fainting and dyspnea on exertion [NYHA Class IIIIV]. 2-D - Echocardiogram and cardiac catheterization with cineangiogram showed typical IHSS findings those were asymmetrical septal hypertrophy [ASH], systolic anterior motion of anterior mitral leaflet [SAM] which induced mild mitral regurgitation [Seller Grade I/IV] and pressure gradient about 60 mmHg between left ventricle and the aorta. Medical treatment with 8-adrenergic blockade [propranolol] and Ca" channel antagonist [Verapamil] had no response. So, we performed trans-aortic ventricular septal myotomy and mymectomy. Resected rectangular muscle bar was 1 Cm x 1 Cm x 4.5 Cm. Post-operative pressure gradient between the left ventricle and the aorta was less than 10 mmHg and SAM. was disappeared with decreased mitral regurgitation grade. Post-operative course was smooth and his symptoms and signs were free without any medication during 12 months follow-up.w-up.

  • PDF

Double Chambered Right Ventricle: -A Report Of 3 Cases- (이 강 우 심 실 -3 예 보 고-)

  • Jo, Dae-Yoon;Rho, Joon-Rhyang;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.269-273
    • /
    • 1979
  • Obstruction of the right ventricular outflow tract occurs in many various positions. Recently, obstruction due to anomalous muscle bundle has been clearly recognized. This anomaly is caused by a large anomalous muscle bundle, which creates an obstruction low in the body of the right ventricle and divides it into two chambers. Three cases of double chambered right ventricle were treated surgically utilizing cardiopulmonary bypass in the Department of Chest Surgery, College of Medicine, Seoul National University. 1] All of the 3 cases were female. 2] In 2 cases, FKG findings were RVH and RAD, but in case 2, normal EKG findings. 3] In case 2, no pressure gradient between the inflow portion and outflow portion of the right ventricle was observed, but in case 1 and 3, pressure gradients were 70 and 64 mmHg, respectively. 4] In 2 of the 3 cases, type II VSD was combined to double chambered right ventricle. 5] All of the 3 cases were discharged with symptomatic improvement after operation.

  • PDF

의공산업의 현황과 전망

  • 고영환
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.91-93
    • /
    • 1989
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

Fermented ginseng, GBCK25, ameliorates hemodynamic function on experimentally induced myocardial injury

  • Aravinthan, Adithan;Antonisamy, Paulrayer;Kim, Bumseok;Kim, Nam Soo;Shin, Dong Gyu;Seo, Jeong Hun;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.40 no.4
    • /
    • pp.462-465
    • /
    • 2016
  • In the present study, we investigated whether treatment with GBCK25 facilitated the recovery of hemodynamic parameters, left ventricle systolic pressure, left ventricular developed pressure, and electrocardiographic changes. GBCK25 significantly prevented the decrease in hemodynamic parameters and ameliorated the electrocardiographic abnormality. These results indicate that GBCK25 has distinct cardioprotective effects in rat heart.

Hemodynamic Evaluation of Monoleaflet Polymer Valve (단엽식 고분자판막의 혈역학적 성능평가)

  • 김상현;장병철
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 1995
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane. To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medicals prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volllme and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

Effect of Nifedipine in Acute Episode of Postoperative Pulmonary Hypertension and Right Heart Failure (심장 수술후에 발생한 급성 폐동맥 고혈압및 우심부전증 환자에서 nifedipine의 효과)

  • Choe, Sun-Ho;Choe, Jong-Beom;Yun, Hyang-Seok
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.736-738
    • /
    • 1992
  • We report the successful use of Nifedipine in the treatment of acute pulmonary hypertension in an young child after a cardiac operation. This patient had undergone patch closure of large ventricular septal defect. She had signs of severe pulmonary artery hypertension unresponsive to hyperventilation, oxygenation, sedation, and a myriad of vas-oactive drugs. Nifedipine, 0.3mg /kg every 4 hours, effectively treated her pulmonary artery hypertension and allowed for a smooth postoperative course and positive outcome. The drug lowered systemic diastolic pressure, but not systolic pressure.

  • PDF

Impact of Hemodialysis on Left Ventricular Performance: A Doppler Echocardiographic Study (혈액투석 유지요법 환자에서 투석 전후의 좌심실 Doppler 심초음파를 이용한 기능지표의 변화)

  • Kang, Dong-Oh;Lee, Du-Ha;Kim, Hyun-Seo;Kim, Hyun-Su;Kim, Sung-Rok;Park, Jong-Seon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.309-317
    • /
    • 1999
  • Background: Left ventricular diastolic filling is an important determinant for maintenance of cardiac output during hemodialysis. Few investigators have studied the influence of hemodialysis on diastolic function. To evaluate the change of left ventricular systolic and diastolic function. we performed M-mode and Doppler echocardiographic studies before and after hemodialysis. Methods: The study population consisted of 30 patients(15 patients were male, mean age $45{\pm}10$ years) with CRF on maintenance hemodialysis. They have normal left ventricular systolic function(Fractional shortening>30%) and no evidence of valvular heart disease or regional wall motion abnormalities. The ejection fraction (EF) was measured using M-mode echocardiography and Doppler indices such as peak E velocity, peak A velocity, isovolumetric relaxation time(IVRT), deceleration time(DT). and left ventricular ejection time(LVET) obtained from Doppler echocardiography. The index of myocardial performance (IMP) was calculated from each of the Doppler velocity indices. Results: The weight reduction after hemodialysis was $2.1{\pm}1.0kg$(p<0.0001), After hemodialysis, there was some decrease in blood pressure(p<0.05), but no significant change in heart rate, EF and fractional shortening, mean VCF, peak A velocity, and DT. And significant reduction in peak E velocity, E/A ratio(p<0.0001. p<0.001), and significant increase in IVRT and IMP(p<0.05, p<0.0001) were noted. Conclusion: In conclusion, preload reduction is the main mechanism that accounts for changes in Doppler diastolic indices after hemodialysis. And an increased IMP suggests that diastolic function may be aggravated after hemodialysis, and that implies impaired left ventricular filling and disturbed left ventricular compliance.

  • PDF