• 제목/요약/키워드: Ventilation plan

검색결과 138건 처리시간 0.022초

아파트 평면형에 따른 여름철 맞통풍 효과 비교 (A Comparative Study on the Cross-Ventilation Effect by the Floor Plan Type of Apartment House during Summer)

  • 김정민;최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.301-306
    • /
    • 2005
  • The purpose of this study is to make clear the cross-ventilation effect by floor plan type in apartment house during summer. The questionnaire survey was carried out during the 26$^{th}$ of August ${\sim}$ the 4$^{th}$ of September 2004. The respondents were 174 residents living in two subject apartment estates. One subject estate (we call A estate) was consisted apartment houses having cross-ventilation floor plan. The other subject estate (we cail B estate) was constructed apartment houses having ordinary floor plan. The field measurements of indoor thermal elements reflecting natural cooling effect by cross-ventilation were carried out at A house in A estate and at B house in B estate. The measurements in two subject houses were taken on simultaneously the 27$^{th}$ of August. The residents living in A apartment estate planed cross-ventilation type show positive responses on thermal sensation and airflow sensation. The averages indoor temperature and air velocity in the A house were 0.9 $^{\circ}$C lower and 0.29 m/s higher than the B house. Therefore, it was found that indoor thermal environment during summer in the house having cross-ventilation floor plan maintained more comfortable than the house having ordinary floor plan by natural cooling effect of cross-ventilation.

  • PDF

초고층 건물에서 연기이동 복합력에 의한 환기계획 (The Ventilation Plane Due to Smoke Driving Combined Forces in Super High-Rise Buildings)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.82-87
    • /
    • 2016
  • 초고층 건물의 환기계획에서 설비의 효율적인 운영을 위해 환기설비는 제연설비 겸용으로 사용되고 있다. 본 연구에서는 지하 4층 지상 59층의 초고층 건물을 분석모델로 선정하고 수치해석을 통해 연기이동력에 의한 층별 압력분포를 검토하였으며, 분석모델 건물에서의 연기이동력이 환기 및 제연에 미치는 영향을 규명하였다. 또한 이들 결과를 바탕으로 분석모델 건물의 환기계획에서 주방용 환기댐퍼를 환기-제연 겸용으로 설계할 때 연기이동의 복합력과 요구되는 댐퍼의 개폐력과의 관계를 운동해석 시뮬레이션을 통해 결정하였고, 그 결과로부터 적합한 댐퍼의 구동장치를 선정하였다.

이중외피시스템을 적용한 고층 주거용건물의 자연환기 성능평가 (A Study on Natural Ventilation Performance for a Double-Skin Facade System in Apartment Buildings)

  • 석호태;김동화;최정민
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.119-126
    • /
    • 2003
  • The purpose of this study is to evaluate the natural ventilation performance for variable external wind speed as a preliminary step to determining the seasonal operating modes of the Double-skin Facade System applied to apartment buildings. For this purpose, two simulation programs are used to compare the Double-Skin Facade System with the Double Sash Window. First, TAS is used to plan a schedule for natural ventilation during the intermediate season and to analyze the cooling loads. Second, CFD is used for a more detailed airflow analysis on a typical floor plan of the model building. The results of the simulations on natural ventilation performance show that the Double-Skin Facade System can reduce the cooling load by 10.5% compared to the Double Sash Window.

Cool Tube System 사례를 활용한 환기부하 절감방안 (Ventilation Load Reduction Plan Using Cool Tube System Case)

  • 정민영;박진철;양영권
    • 토지주택연구
    • /
    • 제10권1호
    • /
    • pp.25-32
    • /
    • 2019
  • In this study, the case analysis data on underground temperature are presented. In addition, numerical analysis of the ventilation load reduction plan was derived according to the residence schedule change for the building with cool tube. The research scope and method are as follows. The overall system principle was examined through reviewing the theory of the Cool tube system. Case study and analysis were conducted. Numerical simulation was used to examine the change in energy usage. Also, the change of load energy in case of varying amount of ventilation was derived based on actual building room schedule. When the Cool tube system was applied to the residential buildings, the cooling load was reduced from 3,331 kW to 193 kW, which showed a reduction effect of about 90%.The heating load was reduced from 42,276kW to 32,575kW by 23%.Also, result shows that the cooling load decreased by 24% and the heating load decreased by 66% when the number of ventilation according to the occupancy schedule was applied.

80년대 표준설계 초등학교 단위 교실의 환경친화적 리노베이션에 관한 연구 (A Study on the Sustainable Renovation for the Classroom unit of Elementary school designed by Standard Plan in 1980s)

  • 박지현;이선영
    • 교육시설
    • /
    • 제13권2호
    • /
    • pp.25-33
    • /
    • 2006
  • Majority of elementary school in Korea are built by standard plan in 1980s. Being deteriorated and uniform, they have lots of problems to meet the new education curriculum and generate environmental problems in terms of its performances. This research intends to review the conditions of classroom units related with the environmental issues and provide the directions of sustainable renovation to meet the updated curriculum focusing on daylighting and ventilation systems for the classroom built by standard plan in 1980s.

주방 환기에 대한 조리사들의 인식도 연구 - 서울 지역을 대상으로 - (A Study on the Recognition of Cooks about the Kitchen Ventilation)

  • 반주원;허준
    • 한국조리학회지
    • /
    • 제11권4호
    • /
    • pp.228-244
    • /
    • 2005
  • The objective of the study is to observe cooks first from the kitchen and those who care health and to grasp the impression regarding the kitchen environment. Also, it grasped the recognition degree of cooks against the elements of kitchen ventilation and kitchen ventilation equipments. We surveyed against 385 cooks who work in the kitchen of special grade hotels and family restaurants, used 5 scales for the object, and executed the analysis. The results of this study are as follows: (1) Health condition of the cooks appeared most highly pain in the shoulder and the neck. (2) for the impression regarding the kitchen environment, temperature was high and the insufficiency of ventilation is answered highly. (3) The importance of kitchen ventilation of cooks was recognized very high. (4) The combustion gas was recognized as very high percentage and the most effective element of the kitchen on the human body to remove first inside the kitchen. (5) Most cooks were recognized that the improvement of ventilation equipments is necessary. (6) The object of ventilation equipments is appeared to maintain comfortable kitchen environment. (7) The optimum operation method of ventilation equipment uses the automatic system of ventilation equipment from the kitchen and it is necessary to maintain the optimum. This research is based on preceding studies, investigating special grade hotels and family restaurants in Seoul. The ventilation plan of the kitchen should be accomplished to improve the health of cooks and productivity.

  • PDF

공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구 (A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance)

  • 김승철;윤종호;백남춘;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF

학교건물의 공기질 개선을 위한 환기시스템 적용에 관한 연구 (A Study on the using of the Ventilation System as the Method of Improvement of Air Quality in the Schools)

  • 안철린;김좌진;금종수;박효순
    • 교육시설
    • /
    • 제11권2호
    • /
    • pp.17-23
    • /
    • 2004
  • The purpose of this study concerns the improvement of air quality in school classrooms. Polluted indoor air is improved by efficient ventilation systems. So it is important to measure the amount of ventilation needed in classrooms. First, the amount of natural ventilation were measured through a tracer gas method. And we have established a heat recovery ventilation system from 4 cases of airflow in classrooms, and we have measured the change of $CO_2$ density. According to air quality measurements in the classrooms, the density of $CO_2$ is well above environmental standards which are acceptable. When the amount of ventilated airflow increases, indoor air quality is improved. It is surveyed that the most suitable amount of external inducted air is 770 CMH to satisfy $CO_2$ less than 1,000 ppm in classrooms. For improvement of air quality in classrooms, we must consider a suitable ventilation plan and installation of ventilation systems when constructing school buildings.

학교 교실의 창호 배치 및 개방면적비에 따른 중간기 자연환기량 및 쾌적성 평가에 관한 연구 (A Study on Evaluation of Natural Ventilation Rate and Thermal Comfort during the Intermediate Season considering by Window Layout and Open Window Ratio)

  • 김여진;최정민
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.207-214
    • /
    • 2019
  • Natural ventilation through openings such as windows in school buildings is an efficient resource for natural cooling during the intermediate season of the year. Because the natural ventilation uses the wind outside the building, the amount of ventilation will depend not only on the wind speed and wind direction but also on the window layout and open window ratio. Therefore, in this study, the natural ventilation plans of school classroom windows are divided into 4 types and 8 cases as shown in Table 1. The characteristics of cooling effect by natural ventilation are simulated by applying Energyplus's Airflow Network Model and the comfort of the occupants is evaluated by the number of hours included in the 80% acceptability range of the ASHRAE Standard 55-2010 adaptive comfort model for the weekdays (Monday-Friday) and the class hours (08: 00-19: 00). Based on the analysis results of the above, this study presents basic data related to classroom cooling plan using intermediate season natural ventilation.

아연도금 부스 환기시스템 개선에 관한 수치해석 (Numerical Analysis on the Improvement of Zinc Plating Booth Ventilation System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2021
  • The purpose of this study is to suggest the optimal shape for a local air ventilation system for fume removal, which is operated in a zinc galvanizing factory, and to propose the improvement plan for a ventilation system used in a zinc galvanizing factory through flow analysis. A part of the air sprayed by an air curtain goes out. It will be necessary to research the position of an air curtain, its spray angles, and its nozzle shape. In addition, additional research needs to be conducted on the shape of the fan installed before a hood in order to make it easy to induce fume. In a local air ventilation system, air is inhaled from the outside. The higher an inlet negative pressure is, the easier fume is removed. It was found that it was necessary to install an appropriate hole in the wall on the back of a push nozzle in order to reduce an inlet negative pressure.