• 제목/요약/키워드: Ventilation frequency

검색결과 143건 처리시간 0.021초

Aerodynamic measurements of across-wind loads and responses of tapered super high-rise buildings

  • Deng, Ting;Yu, Xianfeng;Xie, Zhuangning
    • Wind and Structures
    • /
    • 제21권3호
    • /
    • pp.331-352
    • /
    • 2015
  • A series of wind tunnel tests were conducted on tapered super high-rise buildings with a square cross section by applying synchronous pressure measurement technology. The effects of global strategy of chamfered modification on aerodynamic loads and wind-induced responses were investigated. Moreover, local aerodynamic strategies of opening a ventilation slot in the corner of equipment and refuge floors were carried out. Results show that the global strategy of tapered elevation increased the vortex shedding frequency, but reduced vortex shedding energy, leading to reduction of across-wind aerodynamic loads and responses. Chamfered modification suppressed the across-wind vortex shedding effect on tapered buildings. Opening the ventilation slot further suppressed the strength of vortex shedding and reduced the residual energy related to vortex shedding in aerodynamic loads of chamfered buildings. Finally, the optimized locations of local aerodynamic strategies were suggested.

업무효율성이 향상된 경찰 우의 개발을 위한 경찰 우의 착의실태 조사 (A Study on the Wearing Conditions for Developing Police Raincoat with Advanced Work Efficiency)

  • 유승민;김동은
    • 한국의류학회지
    • /
    • 제40권5호
    • /
    • pp.910-920
    • /
    • 2016
  • This study is to understand the problems of current police raincoats for professional policemen and conscripted policemen. Interviews and a survey were completed to investigate the wearing conditions of current police raincoats. The questionnaire was composed of questions on current wearing conditions of raincoat, motional adaptability, dimensional compatibility, design suitability and demographic information on the research target. The results indicated that the wearing frequency of raincoats had significant difference according to duty and age range. The main reason for the low wearing frequency was the uncomfortableness of working while wearing the raincoat, followed by the inconvenience of managing the raincoat after use and feeling hot while wearing the raincoat. The three most important factors when wearing a raincoat was pleasantness, activity capability and the functionality of the fabric. The satisfaction on body parts during motions tended to be evaluated lower as the raincoat size increased. The results of the dissatisfaction factors indicated that the raincoat hood had the most problems. There was inconvenience when using the equipment belt because officers have to wear their belts inside the raincoat. In regards to the fabric satisfaction level, respondents were less satisfied with ventilation, hygroscopicity, and drying time. Therefor it appeared that the current raincoat had problems due a lack of functionality in regards to ventilation, hygroscopicity, and quick drying; in addition, the satisfaction on motional adaptability had a significant difference according to raincoat size.

컴프레션웨어의 디자인과 제품구성요소 분석 (An Analysis of Compression Wear Designs and Structural Elements)

  • 이정화;전정일;최경미
    • 한국의류산업학회지
    • /
    • 제16권3호
    • /
    • pp.421-433
    • /
    • 2014
  • The aim of this study was to provide compression wear manufacture brands with information needed for product development. 8 tops and 7 bottoms from widely recognized compression wear manufacture brands were selected, and their product structural elements were analyzed, too. The results showed that most compression wear designs were applications of cutting lines designed considering muscle movements of the human body. The average number of cutting lines for patterns and designs were 14 for tops and 15 for bottoms. Different colored material was mainly used on the top for areas that require ventilation or high movement during sports for tops, and for areas that require muscle and joint support during sports for bottoms. The functionality of top materials were found to be stretch, muscle support, moisture absorption and high speed drying, warmth and ventilation for tops, in order of frequency, and stretch, muscle support, moisture absorption and high speed drying, and pressure for bottoms, in order of frequency. Tops were cut in the direction of the lengthwise grain, and bottoms were not only cut in the direction of the lengthwise grain, but also in the direction of the crosswise grain and bias for many products. Tops consisted of an average of 13 organically connected panels, and bottoms consisted of an average of 18 organically connected panels, which was analyzed to improve functionality. The average clothing surface area stretch rate was 85.7% for tops and 70.0% for bottoms, indicating that bottoms were designed to have higher strain rates compared to tops.

수소충전소 성능평가 장비 안전성 평가 연구 (Risk Assessment for Performance Evaluation System of Hydrogen Refueling Station)

  • 강승규;이동훈
    • 한국수소및신에너지학회논문집
    • /
    • 제33권3호
    • /
    • pp.232-239
    • /
    • 2022
  • This study performed qualitative and quantitative risk assessment of equipment for evaluating the protocol of hydrogen refueling stations and suggested measures to improve safety. Hazard and operability study was performed for qualitative risk assessment, and Hy-KoRAM was used for quantitative risk assessment. Through a qualitative risk assessment, additional ventilation devices were installed, simultaneous venting of the storage container was prohibited, and the number of repeated refilling of the evaluation equipment was identified to manage the number of fillings of the container. Through quantitative risk assessment, the area around the device was set as a restricted area when evaluating the station, and measures were suggested to reduce the frequency of accidents.

표면에 다수의 구멍을 뚫고 차단 주파수 영역의 선택이 가능한 풍압저감형 방음벽 (Wind Pressure Reducing Soundproof Wall Which Has Many Holes on the Surface and Selectable Stop-Frequency Ranges)

  • 김상훈;이돈출
    • 대한토목학회논문집
    • /
    • 제36권2호
    • /
    • pp.191-196
    • /
    • 2016
  • 파동의 에돌이와 공명식 머플러 원리를 이용하여 통풍형 방음을 구현하고 그 이론을 설명하였다. 이 방음기술은 차단하고자 하는 주파수영역의 선택이 가능하다. 방음벽을 이중으로 만들고 그 사이를 비워, 방음벽의 구멍을 통해 들어온 음파가 내부에서 공진하여 소멸되도록 하였다. 두께 8cm인 공진통마다 직경 5cm의 공기구멍을 2개씩 뚫고 실험한 결과 넓은 주파수영역대서 평균 25dB정도의 차음효과가 있었다. 일본 컴넥스사의 산란에 의한 투과손실만 있는 경우와의 차음효과를 비교한 결과 같은 통풍능력인 경우에 적어도 10dB이상 차음효과가 높았다. 또한 컴넥스사의 기술은 차음주파수 영역을 선택할 수 없다는 한계가 있었다.

Clinical Practice Guideline of Acute Respiratory Distress Syndrome

  • Cho, Young-Jae;Moon, Jae Young;Shin, Ein-Soon;Kim, Je Hyeong;Jung, Hoon;Park, So Young;Kim, Ho Cheol;Sim, Yun Su;Rhee, Chin Kook;Lim, Jaemin;Lee, Seok Jeong;Lee, Won-Yeon;Lee, Hyun Jeong;Kwak, Sang Hyun;Kang, Eun Kyeong;Chung, Kyung Soo;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • 제79권4호
    • /
    • pp.214-233
    • /
    • 2016
  • There is no well-stated practical guideline for mechanically ventilated patients with or without acute respiratory distress syndrome (ARDS). We generate strong (1) and weak (2) grade of recommendations based on high (A), moderate (B) and low (C) grade in the quality of evidence. In patients with ARDS, we recommend low tidal volume ventilation (1A) and prone position if it is not contraindicated (1B) to reduce their mortality. However, we did not support high-frequency oscillatory ventilation (1B) and inhaled nitric oxide (1A) as a standard treatment. We also suggest high positive end-expiratory pressure (2B), extracorporeal membrane oxygenation as a rescue therapy (2C), and neuromuscular blockage for 48 hours after starting mechanical ventilation (2B). The application of recruitment maneuver may reduce mortality (2B), however, the use of systemic steroids cannot reduce mortality (2B). In mechanically ventilated patients, we recommend light sedation (1B) and low tidal volume even without ARDS (1B) and suggest lung protective ventilation strategy during the operation to lower the incidence of lung complications including ARDS (2B). Early tracheostomy in mechanically ventilated patients can be performed only in limited patients (2A). In conclusion, of 12 recommendations, nine were in the management of ARDS, and three for mechanically ventilated patients.

가정용 인공 호흡기를 사용하는 소아의 임상적 고찰 (Clinical Study of Children Using Home Mechanical Ventilation)

  • 안영준;이승현;김효빈;박성종;고태성;홍수종
    • Clinical and Experimental Pediatrics
    • /
    • 제48권4호
    • /
    • pp.401-405
    • /
    • 2005
  • 목 적 : 급성 호흡부전증, 호흡중추장애, 신경근 질환 등으로 인한 만성 호흡부전 환자들이 가정용 인공 호흡기의 도입으로 가정에서 기계 환기를 받을 수 있게 되어 생명을 연장시키고, 삶의 질을 향상시킬 수 있어 그 사용하는 예가 증가하고 있다. 그러나 이에 대한 임상자료가 거의 없어 저자들은 인공 호흡기를 장착한 환아들을 대상으로 임상실태를 조사하였다. 방 법 : 1997년부터 2003년까지 서울아산병원 소아 중환자실에 입원 후 가정용 인공 호흡기를 장착한 21명의 환아들을 대상으로 하여 후향적으로 의무기록을 분석하고 전화면담을 시행하였다. 결 과 : 대상 환아들은 21명으로 남아 15명, 여아 6명이었다. 인공 호흡기를 장착하였을 때 중간 연령은 31개월(범위 : 2-150개월)이었으며, 호흡기를 장착한 중간 기간은 25개월(범위 : 2-68개월)이었다. 환아들의 원인 질환으로는 호흡중추장애를 포함한 신경근 질환이 16례, 급성 호흡곤란을 포함한 폐질환이 4례, 유전성 대사질환이 1례였다. 인공 호흡기 양식은 압력 조절 양식이 16례(76%), 용적 조절 양식이 5례(24%), 산소가 필요한 경우는 13례(62%)였고, 인공 호흡기를 조금이라도 이탈할 수 있었던 경우는 3례(14%)였다. 기계고장은 19개월마다 1회 발생하였고, 인공 호흡기 장착 후 평균 입원 횟수는 매년 1.7회, 그 원인으로는 폐렴(68%)이 가장 많았다. 추적 관찰한 결과 사망한 환아는 9명(43%)이었고, 사망원인은 기관지 튜브 폐쇄가 4례였다. 인공 호흡기 대여, 산소발생기, 영양식, 진찰 및 치료비용 등을 포함한 모든 의료비용은 월간 평균 111만원이었다. 결 론 : 최근 가정용 인공 호흡기 사용이 증가하고 있으며, 사망원인으로 기관지 튜브 폐쇄가 많아 주의 및 관리를 필요로 하고 인공 호흡기를 장착한 가정에 경제적 어려움이 있어 사회적 관심과 제도적 지원이 필요할 것으로 사료된다.

최근 4년간 극소 저출생 체중아의 인공 호흡기 치료율과 경과 변화에 관한 연구 (A Study on the Changes in Ventilator Care Rate and Outcome of Very Low Birth Weight Infants During Last Four Years)

  • 정변경;김영주;이상길
    • Clinical and Experimental Pediatrics
    • /
    • 제46권11호
    • /
    • pp.1073-1079
    • /
    • 2003
  • 목 적 : 1,500 gm 미만의 극소 저출생 체중아에서 호흡부전시 인공 호흡기 치료에만 의존하던 과거와는 달리 신생아 집중치료의 획기적 발전과 의료환경의 개선으로 새로운 관점에서 인공 호흡기 치료의 시도가 요구되고 있다. 저자들은 1998년부터 기관내 삽관율과 인공 호흡기 치료기간, 합병증 등의 연도별 변화가 있는지를 조사하여 향후 인공 호흡기 치료 방향에 기초적 도움을 주고자 본 연구를 시행하였다. 방 법: 1998년 1월부터 2001년 12월까지 본원 출생아로서 1,500 gm 미만의 극소 저출생 체중아이며 신생아 집중 치료실에서 입원 치료한 뒤 퇴원한 환아 274명을 대상으로 하였으며, 대상아는 병력지를 기초로 재태 연령과 출생 체중을 분석하였고, 인공 호흡기 치료군에서 분만 방법과 임상 특징, 원인 질환, 인공 호흡기 설정시 초기 조건, 사용 방법, 기간, 합병증 등을 후향적으로 분석하였다. 결 과 : 1) 연도별 재태 주수에 따른 인공 호흡기 치료 빈도의 변화 : 27-29주 미숙아의 경우 최근 4년간 인공 호흡기 치료군은 큰 변화 없이 극소 저출생 체중아의 약 76.1%에 해당되었다. 30-33주 미숙아의 경우는 최근 4년간 인공 호흡기 치료 빈도가 감소하는 추세로 1998년, 1999년에 각각 61.9%, 52.9%에서 인공호흡기 의존도를 나타냈으나 2000년에는 48.6%였고, 2001년에는 37.5%에서만이 인공 호흡기의 의존도를 나타내었다. 또한 전체 환아에서 1998년은 69.7%에서 인공 호흡기 치료를 받았으나, 2001년은 42.5%로 감소하였다 2) 인공 호흡기 치료군에서 임상적 특징 : 평균 재태 연령, 출생 체중은 큰 변화가 없었으며, 4년간 모두 반 수 이상에서 남아이고, 분만 방식으로 제왕 절개술에 의한 분만이 60% 이상이었으며, 최근 증가하는 추세이다. 원인 질환으로 중등도 신생아 호흡 곤란 증후군 단독인 경우가 60% 이상이었고, 신생아 호흡곤란 증후군과 동반된 가사 및 무호흡이 있었다 3) 인공 호흡기 치료군에서 동맥혈 가스 분석, 인공 호흡기 설정 및 호흡 지표의 변화 : $PaO_2$는 42.4-44.8 mmHg였고, 평균 기도압은 5.7-6.0 $cmH_2O$, 산소화 지수(OI)는 9.2-11.6이었으며, 인공 호흡기 치료 24-48시간 경과 후 시행한 동맥혈 가스 검사에서 $PaO_2$는 89.3-92.5 mmHg로 호전되었고, 평균 기도압은 4.4-4.7 $cmH_2O$로 낮아졌으며, 산소화 지수는 2.3-2.6 정도로 호전되었다. 4) 인공 호흡기 치료 평균 기간 : 인공 호흡기 치료 기간은 최근 4년간 뚜렷이 감소하는 추세로 7일 이상 장기간 인공 호흡기 치료를 받은 환아는 1998년에 23.9%에서 2001년에는 6.4%로 감소하였고, 4일에서 6일 동안 치료를 받은 경우는 1998년에 76.1%에서 2001년에 9.7%로 감소하였다. 또한 3일 이하의 단기간 치료를 받은 군은 1999년에 28.1%이던 것이 2001년에는 83.9%로 증가하였다. 연도별 평균 치료 기간도 1998년, 1999년에 각각 6.0일, 5.5일에서 2000년, 2001년에 3.6일, 2.7일로 감소하였다. 5) 인공 호흡기 사용 방법과 주요 합병증 : 1998년에는 HFV와 IMV에 의한 인공 호흡기 치료가 주였고, 2000부터 비강내 CPAP을 활성화 하였으며, 2001년에는 HFV와 IMV, 비강내 CPAP의 병용 사용이 35.4%로 늘어났다. 인공 호흡기 치료를 받은 환아들의 주요 합병증으로는 동맥관 개존이 가장 많았으며, 병기 3이상의 미숙아 망막증, grade III 이상의 뇌실내 출혈, 공기 누출 증후군, 만성 폐질환, 뇌실주위 백질연화증 순으로 나타났다. 결 론 : 1,500 gm 미만의 원내 출생한 극소 저출생 체중아의 경우 중증의 신생아 호흡곤란 증후군이 감소하는 추세에 있으며, 인공 호흡기 의존율과 치료 기간 역시 점차 낮아지는 경향이다. 따라서 비강내 CPAP의 조기 사용으로 기도 삽관을 통한 침습적인 인공 호흡기 치료관리 기회를 줄일 수 있을 것으로 기대된다.

CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구 (Smoke Control Performance of a Serial Structure Using "CONTAM")

  • 김미선;서동길;구선환;유영민;송영주
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.53-62
    • /
    • 2019
  • 최근 건축물은 대지 이용의 효율성을 높이기 위해 주상 복합화·고층화되는 추세이며, 이에 따른 화재의 발생빈도 및 잠재적인 위험요소도 증가하고 있다. 특히, 고층 공동주택의 경우 비상용승강기와 별도로 승용승강기 중 1대 이상을 피난용승강기로 설치하게 되어 특별피난계단 부속실, 비상용승강기 승강장 겸용의 경우 피난용승강기 승강장과 직렬형태의 구조가 되어 새로운 형태의 제연구역 이 발생한다. 따라서 비상용승강기 승강장과 피난용승강기 승강장의 직렬형태 구조에 대한 제연구역 선정의 제시가 필요하며, 새로운 형태에서 제연성능을 달성하는 것에 대한 문제가 대두되고 있다. 따라서 본 논문에서는 이러한 문제를 해결하기 위해 CONTAM을 이용하여 각 제연구역 형식(비상용승강기 승강장 단독제연, 피난용승강기 승강장 단독제연, 비상용승강기 승강장과 피난용승강기 승강장 동시제연 누설틈새 적용·미적용)의 방연풍속, 차압을 확인하고, 직렬형태 구조에 대해 제연성능을 확보하기 위한 방안을 제시하고자 한다.

전시마취시 흡입압력기준의 양압조절호흡이 폐포환기 정도에 미치는 영향 (Effects of Inspiratory Pressure Preset on Alveolar Gas Exchange Using Anesthetic Ventilator)

  • 서일숙;강희주;김흥대
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.105-110
    • /
    • 1988
  • 흡입전신마취시에 마취호흡기를 사용할 겨우 환자에게 가장 적절한 1회 호흡량을 흡입시킬수 있는 방법을 알아보기 위하여 전신마취환자 30명에서 흡입기압력 $10cmH_2O$가 되도록 용량조절마취호흡기의 1회 호흡량을 조절하고 호흡수를 분당 12회로 하여 기계조절양압호흡을 유지시켜 보았던 바 다음과 같은 결과를 얻었다. 1) PH : $7.39{\pm}0.01$로서 정상범위내 이었다. 2) $PaCO_2$ : $34{\pm}0.6mmHg$ 로서 약간의 과환기상태 이었다. 3) $PaO_2$ : $228.0{\pm}8.2mmHg$ 이었다. 4) Buffer base : $20.7{\pm}0.3mEq/{\ell}$로서 약간의 염기부족상태 이었다. 이상의 결과로 미루어 보아 전신마취시 충분한 근 이완상태에서 기계조절호흡을 시행하는 경우 1회 호흡량 조절은 흡기압력을 $10cmH_2O$로 유지함이 가장 바람직한 것으로 사료된다.

  • PDF