• 제목/요약/키워드: Ventilation facility

검색결과 164건 처리시간 0.027초

공기보다 가벼운 가스 사용시설의 폭발위험장소 설정방안에 대한 연구 (A Study on Classification of Explosion Hazardous Area for Facilities using Lighter-than-Air Gases)

  • 임지표;정창복
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.24-30
    • /
    • 2014
  • There have been controversies over whether explosion hazardous area(EHA) should be classified for facilities which use lighter-than-air gases such as city gas, hydrogen and ammonia. Two view points are confronting each other: an economic piont of view that these gases are lighter than air and disperse rapidly, hence do not form EHA upon release into the atmosphere, and a safety point of view that they are also inflammable gases, hence can form EHA although the extent is limited compared to heavy gases. But various standards such as KS, IEC, API, NFPA do not exclude light gases when classifying EHA and present examples of EHA for light gas facilities. This study calculates EHA using the hypothetical volume in the IEC code where the hole sizes required for the calculation were selected according to various nominal pipe sizes in such a way to conform to the EHA data in the API code and HSL. Then, 25 leakage scenarios were suggested for 5 different pipe sizes and 5 operating pressures that cover typical operating conditions of light gas facilities. The EHA for the minimum leakage scenario(25 mm pipe, 0.01MPa pressure) was found to correspond to a hypothetical volume larger than 0.1 $m^3$(medium-level ventilation). This confirms the validity of classifying EHA for facilities using lighter-than-air gases. Finally, a computer program called HACPL was developed for easy use by light gas facilities that classifies EHA according to operating pressures and pipe sizes.

PET 사이클로트론 시설의 공기 방사화 분석 (Analysis of Air Activation in PET Cyclotron Facility)

  • 장동근;강세식;김창수;김정훈
    • 한국방사선학회논문지
    • /
    • 제10권7호
    • /
    • pp.489-494
    • /
    • 2016
  • 사이클로트론에서 발생되는 핵반응은 불필요한 중성자를 발생시키며, 이로 인해 주변 물질들이 방사화되게 된다. 방사화된 물질은 방사선피폭의 원인으로, 공기가 방사화 되었을 경우 인체에 흡입되어 내부피폭을 발생 시킨다. 이에 본 연구에서는 16.5 MeV의 초소형 사이클로트론의 운영에 따른 내부 공기의 방사화를 분석하고자 하였다. 실험결과 초소형 사이클로트론의 핵반응으로 발생되는 방사화는 종사자에게 매우 낮은 내부피폭을 발생시키는 것을 확인할 수 있었으며, 방사화로 인하여 발생된 방사능을 법적 기준치와 비교하여 보았을 때 기준치 이하로 법적 관리의 대상에서 제외 될 수 있음을 알 수 있었다. 하지만, 사이클로트론의 에너지가 높아짐에 따라 내부피폭의 위험성은 더욱 높아질 우려가 있으며, 이에 따라 국내에 정립 되어 있지 않는 방사선 관련 시설의 환기설비에 대한 기준이 필요할 것으로 사료되었다.

Air Leakage Analysis of Research Reactor HANARO Building in Typhoon Condition for the Nuclear Emergency Preparedness

  • Lee, Goanyup;Lee, Haecho;Kim, Bongseok;Kim, Jongsoo;Choi, Pyungkyu
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.354-358
    • /
    • 2016
  • Background: To find out the leak characteristic of research reactor 'HANARO' building in a typhoon condition Materials and Methods: MELCOR code which normally is used to simulate severe accident behavior in a nuclear power plant was used to simulate the leak rate of air and fission products from reactor hall after the shutdown of the ventilation system of HANARO reactor building. For the simulation, HANARO building was designed by MELCOR code and typhoon condition passed through Daejeon in 2012 was applied. Results and Discussion: It was found that the leak rate is $0.1%{\cdot}day^{-1}$ of air, $0.004%{\cdot}day^{-1}$ of noble gas and $3.7{\times}10^{-5}%{\cdot}day^{-1}$ of aerosol during typhoon passing. The air leak rate of $0.1%{\cdot}day^{-1}$ can be converted into $1.36m^3{\cdot}hr^{-1}$, but the design leak rate in HANARO safety analysis report was considered as $600m^3{\cdot}hr^{-1}$ under the condition of $20m{\cdot}sec^{-1}$ wind speed outside of the building by typhoon. Conclusion: Most of fission products during the maximum hypothesis accident at HANARO reactor will be contained in the reactor hall, so the direct radiation by remained fission products in the reactor hall will be the most important factor in designing emergency preparedness for HANARO reactor.

IoT 기반 실내 공기질 모니터링 시스템 (Indoor Air Quality Monitoring Systems in the IoT Environment)

  • 오창세;서민석;이정혁;김상현;김영돈;박현주
    • 한국통신학회논문지
    • /
    • 제40권5호
    • /
    • pp.886-891
    • /
    • 2015
  • 최근 전 세계적으로 인류의 건강을 위협하는 요소로 대기오염이 대두되고 있는 가운데 세계보건기구(WHO : World Health Organization)의 발표에 의하면 대기오염으로 인해 사람의 건강을 해친다고 발표했으며, 서울시의 '2011~2014년 7월 다중이용시설 실내 공기 질 측정 결과'에 의하면 대부분의 다중이용시설에서 실내공기오염도 기준을 위반한 것으로 조사되었다. 이러한 실내에서 발생하는 대기오염은 폐 질환, 천식, 기관지염 등의 질병을 유발하며 본 논문에서는 이와 관련하여 환경센서를 이용하여 실내공기질을 측정하고, 측정된 데이터를 분석하여 환기 개선에 필요한 액츄에이터 신호를 생성하고 실시간으로 실내 공기 질 측정 모니터링 시스템을 구현하여, 우리 생활에서 대기오염을 자율적으로 관리할 수 있도록 한다.

아리랑2호 영상을 이용한 3차원지형 분석 및 적지분석 (3D Terrain Analysis and Suitability Analysis Using KOMPSAT 2 Satellite Images)

  • 한승희;이진덕
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2008년도 춘계 종합학술대회 논문집
    • /
    • pp.436-440
    • /
    • 2008
  • 단지계획 또는 특정 목적의 시설물 설립을 위한 적지선정은 제반여건과 주변환경을 면밀하게 고려해야 한다. 특히, 인간의 생활공간이라면 채광 및 통풍, 부지활용의 효용성 등이 중요한 요소이다. 이를 위해서 3차원 지형모델링과 가상 시뮬레이션을 통한 다각적인 입체분석이 필요하다. 이러한 지형모델링에 필수적인 고해상 위성영상이 아리랑2호 위성(KOMPSAT2)을 통해 국내기술로 제공되고 있으므로 저렴한 비용으로 처리가 가능해 졌다. 본 연구에서는 특정목적의 단지계획을 위해 몇 개의 후보지를 선정하고 3차원 지형모델링과 토지정보를 이용하여 적지분석을 하고자 하였다. 이를 위해 필지분석, 지가산정, 경사도 분석, 향분석을 실시하였으며 각 후보지 별 평가지표를 마련하여 정량적인 평가를 시도한 결과 효율적이며 합리적으로 적지선정을 할 수 있었다.

  • PDF

제주지역 원도우 베이커리 종사자의 직무환경이 경영성과에 미치는 영향 (The effects of job environments for window bakery employee in Jeju on the management performance)

  • 김철곤
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.35-48
    • /
    • 2019
  • 본 연구는 제주지역 원도우 베이커리 종사자의 직무환경이 경영성과에 미치는 영향을 조사하였다. 그 결과 제주지역 윈도우 베이커리 종사자의 직무환경요인은 인적환경, 작업환경, 시설환경, 복지환경, 편리환경으로 나타났으며, 경영성과 요인으로는 경제적 성과, 고객적 성과, 종사원 성과 요인으로 나타났다. 직무환경요인이 경영성과 중 경제적 성과에는 작업환경(.176), 편리 환경(.227)이 영향력이 있는 것으로 나타났으며, 고객적 성과에는 인적환경(.147), 작업환경(.095)이 영향력이 있는 것으로 나타났으며, 종사원 성과에는 인적환경(.195), 작업환경(.135), 복지환경(.129)이 영향력이 있는 것으로 나타났다. 따라서 제주지역 원도우 베이커리의 직무환경은 경영성과에 유의한 정(+)에 영향을 미칠 것이다라는 가설은 부분채택 되었으며, 경영성과 요인에 모두 영향을 미치는 직무환경 요인으로는 작업환경으로 적당한 습도, 환기 및 작업 동선을 고려한 공간의 배치가 제일 중요한 것으로 나타나, 윈도우 베이커리의 직무환경 중 작업환경개선이 필요한 것으로 나타났다.

온라인 위생교육프로그램의 지속적 제공이 어린이급식소 위생관리 수행도에 미치는 영향 (The Effect of Continuous Provision of On-line Hygiene Education Program on Hygiene Management Performance of Children's Cafeterias)

  • 이경아
    • 급식외식위생학회지
    • /
    • 제2권2호
    • /
    • pp.97-102
    • /
    • 2021
  • The purpose of this study was to investigate the effect of developing and continuously providing on-line hygiene education programs on the improvement of hygiene conditions in children's cafeterias. As a result of the 2020 sanitation and safety checklist analysis, 6 items (personal hygiene, separate use, clean ventilation, temperature control of refrigerators, country of origin, food distribution) were derived and on-line hygiene education programs for each of 6 items were produced. ① Customized educational materials and self-inspection checklists were provided to 208 children's cafeterias. After that, educational videos were provided through Kakao Talk twice a week for 6 months, and they were made available for viewing at any time through YouTube upload, ③ Kakao Talk Through this, a quiz related to the educational video was conducted to give feedback for interaction with the cook. As a result of analyzing the total hygiene and safety checklist score of all registered facility catering centers by visit order, in 2020 it was 82.8 points/100 points, but in 2021, it was 84.2 points (1st round), 89.3 points (2nd round), 91.4 points (3 points) The score improved significantly (p<0.001) as the on-line hygiene education program continued. As a result, significant (p<0.001) changes were observed in the items of 'Knife, chopping board' and 'Sanitation clothes, sanitary hat, sanitary shoes, apron, and sanitary gloves', confirming a clear improvement effect. Therefore, it is considered that the on-line hygiene education program will play a positive role in showing a lasting effect on improving hygiene management in children's cafeterias.

접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가 (Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process)

  • 우재민;김동준;신지훈;민기홍;이채관;양원호
    • 한국환경보건학회지
    • /
    • 제49권2호
    • /
    • pp.78-88
    • /
    • 2023
  • Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.

Assessment of Occupational Health Risks for Maintenance Work in Fabrication Facilities: Brief Review and Recommendations

  • Dong-Uk Park;Kyung Ehi Zoh;Eun Kyo Jeong;Dong-Hee Koh;Kyong-Hui Lee;Naroo Lee;Kwonchul Ha
    • Safety and Health at Work
    • /
    • 제15권1호
    • /
    • pp.87-95
    • /
    • 2024
  • Background: This study focuses on assessing occupational risk for the health hazards encountered during maintenance works (MW) in semiconductor fabrication (FAB) facilities. Objectives: The objectives of this study include: 1) identifying the primary health hazards during MW in semiconductor FAB facilities; 2) reviewing the methods used in evaluating the likelihood and severity of health hazards through occupational health risk assessment (OHRA); and 3) suggesting variables for the categorization of likelihood of exposures to health hazards and the severity of health effects associated with MW in FAB facilities. Methods: A literature review was undertaken on OHRA methodology and health hazards resulting from MW in FAB facilities. Based on this review, approaches for categorizing the exposure to health hazards and the severity of health effects related to MW were recommended. Results: Maintenance workers in FAB facilities face exposure to hazards such as debris, machinery entanglement, and airborne particles laden with various chemical components. The level of engineering and administrative control measures is suggested to assess the likelihood of simultaneous chemical and dust exposure. Qualitative key factors for mixed exposure estimation during MW include the presence of safe operational protocols, the use of air-jet machines, the presence and effectiveness of local exhaust ventilation system, chamber post-purge and cooling, and proper respirator use. Using the risk (R) and hazard (H) codes of the Globally Harmonized System alongside carcinogenic, mutagenic, or reprotoxic classifications aid in categorizing health effect severity for OHRA. Conclusion: Further research is needed to apply our proposed variables in OHRA for MW in FAB facilities and subsequently validate the findings.

하수처리오니 알칼리 안정화 처리시설에서의 암모니아 발생특성 (Characteristics of Ammonia in Alkaline Stabilization Facility of Sludge from Sewage Treatment Plant)

  • 김용준;정다위;정미정;유혜영;윤철우;신선경
    • 유기물자원화
    • /
    • 제24권3호
    • /
    • pp.23-33
    • /
    • 2016
  • 본 연구는 하수처리시설의 유기성슬러지가 알칼리 안정화 처리시설을 거쳐 발생되는 암모니아의 특성을 조사하였다. 암모니아 검지관을 통해 알칼리 안정화 처리시설의 혼합 및 양생 공정에서 87.78 ppm($66.62mg/m^3$) ~ 1,933 ppm($1,467.01mg/m^3$) 으로 높은 농도의 암모니아가 검출 되었다. 이는 하수처리오니의 질소산화물이 생석회와 혼합되며 암모니아로 변환되는 것으로 예상된다. 일부 시설에서는 황화수소, 메틸메르캅단이 비교적 높은 농도로 검출되었으나, 대부분의 시설에서는 암모니아를 제외한 악취 물질은 검출되지 않았다. 공정 중 암모니아의 농도는 일반적으로 혼합 > 양생 > 반출 > 저장 > 건조 > 입고 순으로 높게 나타났다. 현재 운영 중인 5개 알칼리 안정화 처리시설에서 발생된 악취 물질들은 황산과 차아염소산 등을 사용하여 습식처리하는 것으로 조사되었다. 각 시설은 1 ppm($0.76mg/m^3$), 50 ppm($37.95mg/m^3$) 또는 100 ppm($75.89mg/m^3$)으로 방출되도록 설계되었으나 설계 기준을 만족하지 못하는 것으로 나타났다. 암모니아의 경우, 일부 알칼리 안정화 처리시설은 노동부가 정한 노출기준을 초과하는 것으로 조사되었다. 이것은 향후 근로자의 안전을 위해 적절한 환기가 필요함을 의미하고 있다. 또한, 암모니아를 포함한 악취물질이 시설의 부지경계선에서 검지관으로 검출되지 않았으나, 현재의 운전상태로 볼 때, 미량의 악취물질이 존재할 것으로 판단된다.