• 제목/요약/키워드: Ventilation effect

검색결과 647건 처리시간 0.023초

공동주택의 적정 환기량 및 필터의 선정 - 실내입자농도를 중심으로 - (Selection of Ventilation Rate and Filter for a Residential Housing in View of Indoor Particle Concentration)

  • 노광철;정의경;황정호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.517-522
    • /
    • 2008
  • Ventilation rate and filter were selected to simultaneously satisfy indoor air quality and minimize energy consumption in residential housing. The concentrations of indoor particles were calculated using an adapted mass balance model for various ventilation airflow rates. To satisfy the guidelines for indoor concentrations of particles, the minimum ventilation rates of 1.0/h, 0.6/h and 0.4/h were required for MERV11, MERV13 and MERV14, respectively. And the fan power consumptions induced by ducts, a heat exchanger and a filter were calculated for various ventilation airflow rates. The increase in the ventilation rate caused a dramatic increase in the power consumption, but the filter performance did not have much of an effect on the fan power for ventilation airflow rates lower than 0.4/h. The use of the ventilation filter of MERV 14 was suggested at a ventilation rate of 0.4/h when the fan power consumptions were considered in addition to the indoor concentrations of particles and $CO_2$. The use of the MERV14 filter at a ventilation rate of 0.6/h could be more effective than the additional use of an indoor air cleaner when the residential housing unit was ventilated.

  • PDF

윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구 (An Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference)

  • 한동훈;김영식;정한식;정효민;최순호
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.175-184
    • /
    • 2017
  • With the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a "wind turbine," was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of $10^{\circ}C$ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.

플라스틱 단동온실의 천창 종류에 따른 자연환기 효과 (Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse)

  • 라쉬드아드난;이종원;김현태;이현우
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.225-233
    • /
    • 2019
  • 여름철에 자연환기는 온실의 온도를 낮추는데 중요한 역할을 한다. 온실의 형태, 환기창 종류, 환기창의 위치 등은 자연환기 성능에 큰 영향을 미친다. 본 연구에서는 전산유체역학(CFD)을 이용하여 다양한 천창구조에 대하여 측창에 따른 부력환기 효과를 비교분석 하였다. Boussinnesq 가정을 사용하여 전체 계산영역에 대한 부력효과를 시뮬레이션 하였다. 또한 RNG $K-{\varepsilon}$ 난류모델을 사용하였다. 일사량 효과를 시뮬레이션 하기 위해 Solar ray tracing과 함께 Discrete originates (DO) radiation 모델을 사용하였다. 실험온실 내부의 온도를 측정하여 CFD모델을 검증하였으며, 실험값과 계산값이 잘 일치하는 것으로 나타났다. 7가지의 천창구조에 대하여 온실의 내외부 온도차이와 환기횟수를 비교하였다. 내외부온도의 차이는 $3.2{\sim}9.6^{\circ}C$ 범위로 나타났고, 환기횟수는 $0.33{\sim}0.49min^{-1}$ 범위로 나타났다. 고깔형 천창구조 온실의 경우 내외부 온도차이가 $3.2^{\circ}C$로 가장 낮았고 환기횟수도 $0.49min^{-1}$로 가장 높게 나타나 환기효과가 가장 우수한 것으로 나타났다.

혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구 (An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor))

  • 이윤호;이석원;이경호;김현욱
    • 한국산업보건학회지
    • /
    • 제29권3호
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.

경남지역 학교 급식조리실 개선 전후 환기성능 평가 (Evaluation of Ventilation Effectiveness Before and After Kitchen Renovation in Schools of Gyeongsangnam-do)

  • 손종원;김태형;하현철;김병훈
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.35-47
    • /
    • 2024
  • Objectives: Many cases of lung cancer have been reported by school kitchen workers as occupational cancer. Twenty-eight schools in Gyeongsangnam-do Province were selected to evaluate the effect of improved kitchen ventilation systems. Ventilation characteristics before and after renovation were compared and design techniques were identified. Methods: In the design stage for kitchen ventilation systems, expert intervention was used to improve the designs. Ventilation characteristics and air quality were evaluated before and after the renovations. Hood face velocity and fan flow rate were measured and the smoke visualization technique was used to evaluate the capability of protecting worker's breathing zone. The concentrations of PM0.3 were measured at points not adjacent to cooking equipment because these concentrations fluctuate greatly. Results: Mean hood face velocity increased from 0.29 m/s before renovation to 0.7m/s after renovation. The concentrations of PM0.3 showed a roughly 95% reduction. Concentrations of CO showed more than a 75% reduction. Smoke visualization showed greater protection of workers' breathing zone. Conclusions: Advanced design techniques for school kitchen ventilation systems were applied to renovate old kitchen ventilation systems. The performance of the new kitchen ventilation systems was nearly excellent. Further improvement of design techniques is still needed, however.

후면 환기조건에 따른 건물외피용 태양광발전(BIPV) 모듈의 열적 영향에 관한 실험연구 (Experimental Study on the Thermal Effect of BIPV Modules Depending on the Ventilation Type of PV Module Backside)

  • 윤종호;김재웅
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.81-89
    • /
    • 2006
  • Building integrated photovoltaic (BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. On the other hands lots of architectural considerations should be reflected such as Installation position, shading, temperature effect and so on. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated This study is on the combined thermal and PV performance evaluation of BIPV modules. The purpose of this study is to investigate a temperature effect of PV module depending on the ventilation type of PV module backside. Test cell experiment was performed to identify the thermal and power effect of PV modules. Measurement results on the correlation of temperature and power generation were obtained. Those results can be utilized for the development of optimal BIPV installation details in the very early design stage.

The Effect of Xiaohongshu Service Quality on the Stickiness Through the Emotional Responses of Users

  • Jie, Xu;Park, Chanuk;Lee, Sin-Bok
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.183-197
    • /
    • 2021
  • Xiaohongshu is called China's Instagram and is leading overseas product purchases and culture sharing. The purpose of this study is to investigate the structural relationship between Xiaohongshu service quality, emotional response perceived by users, and adhesion to confirm the impact on Xiaohongshu's adhesion at a time when non-face-to-face activities due to COVID-19 have increased. This study distributed and collected questionnaires from October 1st to October 7th, 2021, targeting 210 online shopping mall users. The research results were derived from a total of 206 questionnaires, excluding 4 questionnaires such as omission of record contents, and the causal relationship of the existing PAD model was attempted to be reported by revising and supplementing the existing PAD model. As a result of the study, first, it was confirmed that design among service quality had a positive effect only on ventilation during the user's emotional response. Second, it was confirmed that information among service quality had a positive effect on pleasure and ventilation among users' emotional responses. Third, it was found that security among service quality had a positive effect on pleasure among users' emotional responses. Finally, it was found that pleasure and ventilation had a positive effect on adhesion in the user's emotional response. Based on this result, it is expected that it will be used for operation on other online platforms than the plan for the development of Xiaohongshu.

쏠라 썬루프를 이용한 주차환기 시스템의 효과에 관한 실험적 연구 (An Experimental Study on the Benefit of Pre-ventilation Using Solar Sunroof)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권6호
    • /
    • pp.89-95
    • /
    • 2014
  • This study presented the benefit of the pre-ventilation using solar sunroof with integrated photovoltaic. Recent year, auto-makers make an effort to enhance the fuel efficiency and moreover to clean the cabin passenger's health. Solar energy, one of the alternative energies, adapted in automotive air handling system, in order to pre-ventilation when vehicle parked under the sun in summer. The power generated by a prototype solar sunroof has been used to run blower in a air handing system. And the solar sunroof was installed in a vehicle, and evaluated to find out benefit of the pre-ventilation. The effect of reducing the cabin temperature about $3^{\circ}C{\sim}10^{\circ}C$ with 20 ~ 40W power generator from solar sunroof were obtained in the pre-ventilation test. This reduced thermal load can lead to the reduction of air-conditioning operation time than that of current car. Moreover, fuel economy may increase as a results of the short use of the air-conditioning time. Additionally, Total Volatile Organic Compounds in the cabin is reduced maximum 80% than that of the current vehicle.

자연 배기 터널에서의 연기 거동에 관한 연구 (A Study of Smoke Movement in Tunnel Fire with Natural Ventilation)

  • 김성찬;이성룡;김충익;유홍선
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.976-982
    • /
    • 2002
  • In this study, smoke movement in tunnel fire with natural ventilation shaft has been investigated with various size of fire source. Gasoline pool fire with different size of diameter - 73mm, 100mm, 125mm and 154mm - was used to describe fire source. Experimental data is obtained with 1/20 model tunnel test and its results are compared with numerical results. The computation were carried out using FDS 1.0 which is a field model of fire-driven now. Temperature profiles between measured and predicted data are compared along ceiling and near the ventilation shaft. Both results are in good agreement with each other. In order to evaluating a safe egress time in tunnel fire, horizontal smoke front velocity was measured in model tunnel fire tests and those are compared with numerical results. According to the presence or absence of natural ventilation shaft, ventilation effect are estimated quantitatively. Finally, this paper shows that computational fluid dynamics(CFD) is applicable to predict fire-induced flow in tunnel.

다기능온돌시스템을 이용한 자연환기성능 평가 (Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System)

  • 조동우;유기형;유정연;정해권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF