• Title/Summary/Keyword: Ventilation effect

Search Result 647, Processing Time 0.031 seconds

Analysis on Living Factor and Present Condition of Indoor Thermal Environment in Apartment Units during Winter (아파트의 겨울철 실내온열환경 실태와 생활요인 분석)

  • Choi, Yoon-Jung;Jeong, Youn-Hong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.281-284
    • /
    • 2008
  • The purposes of this study were to make clear the present condition of indoor thermal environment in apartment units and to analyze the relation of the living factors with indoor thermal elements. The field surveys consisted of measurements on physical elements and observations on living factors and interview on resident's subjective responses were carried out in 20 apartment units. The field surveys were carried out during the $January{\sim}March$ 2007. Measuring elements were air temperature, globe temperature, and relative humidity. As results, the averages of indoor temperature each houses were $21.2{\sim}27.2^{\circ}C$, the number of houses exceed the comfort zone were 4. The averages of globe temperature each houses were $21.3{\sim}27.5^{\circ}C$, 6 houses exceeded the comfort zone. The means of relative humidity were $19.5{\sim}58.8%$, relatively dry condition. The clothing value of residents were $0.39{\sim}0.89$ clo(average 0.68 clo). The average of thermal sensation ratings each room were $4.2{\sim}4.8$, 'neutral'$\sim$'slightly warm'. The results of regression analysis on relations of living factors with the thermal elements are as follow; ventilation time(outdoor air exchange), door opening time with balcony, and gas cooker use time had significant effect on indoor temperature.

  • PDF

A Study on the Eco-Tecnique of EcoCenter - Focused on the Building Material and Solar System - (에코센터의 생태건축기술에 관한 연구 - 건축재료와 태양에너지활용시스템을 중심으로 -)

  • Choi, Young-Ho;Shim, Woo-Gab
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Ecological architecture enables people to recycle and reuse architectural resources within the category of ecosystem and also to minimize the effect on environment in a whole process, including architectural planning, usage and exhaustion to use sustainable energies. Rammed earth wall construction method utilized in EcoCenter located in Crystalwaters ecological village in Austrailia is a good example, which maximizes its advantages and also covers its limits to use soil and wood as structural resources. In a case of wood, they used non-treated timber to minimize environmental load and utilized used materials in openings. In the roofs, aluminum coated steel which is plated with zinc collects rain effectively even though it is not regenerable. Nontoxic finishes and insulation in floor and ceiling with used papers are able to minimize its environmental load. Solar energy system applied in EcoCenter enables them to market extra energy with electricity companies as well as support needs of its own buildings to utilize photovoltaic panel system with PV panels. Passive solar system is planned effectively in heating and cooling to apply regenerative walls in a use of rammed earth wall construction and natural ventilation systems through openings.

Greenhouse Cooling by Fog System (FOG SYSTEM 을 이용한 여름철 온실냉방)

  • 서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.60-71
    • /
    • 1999
  • This study was performed to improve underirable warm greenhouse environment by fog cooling system in summer season. The resultsof droplet size analysis and cooling effects for fog cooling system are summarized as follows ; 1. At the pump pressure of 70kgf/$\textrm{cm}^2$ , the mean (SMD) drop size was 22.6${\mu}{\textrm}{m}$ and the maximum and minimum drop size was 45.68${\mu}{\textrm}{m}$ and 1.73${\mu}{\textrm}{m}$ , respectively, and almost all of the drop size was less than 40${\mu}{\textrm}{m}$. 2. The temperature of fog cooling greenhouse with 60% shading was dropped more than 2$^{\circ}C$ below the ambient temperature , while the greenhouse temperature without shading was 1$^{\circ}C$ higher than the ambient temperature. 3. It was found that fog spraying intervals were significantly influential on cooling effect. 4. When the greenhouse was ventilated sufficiently by natural vent system, green house temperature could be maintained by 2.5$^{\circ}C$ lower than the ambient temperature, while it was difficult to drop the greenhouse temperature below ambient temeperature without sufficient ventilation. 5. It was found that the temperature of experimental greenhouse could be maintained 3$^{\circ}C$ to 14$^{\circ}C$ lower that of control greenhouse though there were variations depending on experimental and weather conditions.

  • PDF

The Effect of Chest Physical Therapy on Improvement of Pulmonary Function in the Patients with Stroke (호흡기계 물리치료가 뇌졸중환자의 폐기능 증진에 미치는 영향)

  • Kim Jae-Hyun;Hong Wan-Sung;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.133-144
    • /
    • 2000
  • The purpose of this study was to determine whether respiratory physical therapy might increase the pulmonary function of the patients with stroke or not. Twenty patients with stroke were randomly assigned to experimental and control group. During four weeks, both groups participated in the conventional physical therapy and only the experimental group added in a program of respiratory physical therapy. Respiratory physical therapy consisted of chest mobilization, resistive ventilatory muscle training used the method of PNF technique and relaxed diaphragm breathing. Baseline and post-test measurements were made of vital capacity. inspiratory capacity, expiratory reserve volume, farced vital capacity, forced expiratory volume at one second, $FE1/FVC(\%)$ and maximal voluntary ventilation. Ater four weeks, the experimental group showed the significant improvement in VC(p<.05). FVC(p<.05), FFV1(p<.05) md MVV(p<.05). However, the controll group showed no significant differnece. As compared th the relationship of dependent variables between the experimental group and control group. experimental group showed the significant difference in VC(p<.01), FEV1(p<.05) and MVV(p<.05). These findings suggest that respiratory physical therapy can be used to improve pulmonary function in stroke patients. Also, respiratory physical therapy should be performed for at least four weeks and be followed by the continuous respiratory exercise programs.

  • PDF

Investigation on Conservation Environment of the Seokguram Grotto (National Treasure No. 24) (국보 제24호 석굴암의 보존환경)

  • Hong, Jung-Ki;Eom, Doo-Sung
    • 보존과학연구
    • /
    • s.24
    • /
    • pp.169-184
    • /
    • 2003
  • Yearly mean temperature and relative-humidity of the Seokguram Grotto was measured $19~23^{\circ}C$, 40~44% from May, 1998 to December,2002. The measurement has little differences comparing to the optimum guideline (temperature : $20^{\circ}\pm2^{\circ}C$, relative-humidity : $50^{\circ}\pm5%$). It is necessary to increase humidity in the Seokguram Grotto during winter because of heating and decrease the temperature during summer because of a higher temperature of outside. In addition, the diurnal range keep in $4^{\circ}C$ of temperature and in 10% of relative-humidity. Yearly mean concentration of $CO_2$(carbon dioxide) was measured538~658ppm that is higher than concentration of normal atmosphere(360 ppm). The $CO_2$ has an cumulative effect on the surface of stone cultural properties as a form of carbonic acid($H_2CO_3$) after reaction with water. HVAC (Heating, Ventilation and Air Conditioning) system should be operated to maintain ideal state for the preservation according to the optimum guideline. Also, the entrance into the Seokguram Grotto should be controlled to prevent a sudden fluctuation of humidity and temperature. Human could carry small particles like a microdust, microbe, etc., into the Seokguram Grotto and also could damage the surface by a direct touch.

  • PDF

Effects of educational intervention on single-rescuer respiratory-assistant therapy using a bag valve mask (백-밸브-마스크를 이용한 1인 호흡보조요법 교육의 효과)

  • Lee, Yong-Jae;Uhm, Dong-Choon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.3
    • /
    • pp.29-40
    • /
    • 2019
  • Purpose: This study was conducted to identify the effects of educational intervention on pre-test and post-test tidal volume, endotracheal peak pressure, and ventilation interval measurements during single-rescuer respiratory-assistant therapy by paramedic students. Methods: The present study, with a quasi-experimental design, included a pre-test and post-test nonequivalent control group. A total of 62 paramedic students (31, experimental group; 31, control group) participated in this study. The intervention lasted 80 minutes. Data were collected from each student before the intervention and two weeks after the intervention, between September 3 and 21, 2018. The collected data were analyzed using IBM SPSS Statistics for Windows, Version 25.0. Results: Tidal volume (p<.001) and endotracheal peak pressure (p=.002) measurements after the intervention were significantly different between the two groups. Analysis of covariance was used to control the variance (the pretest value of endotracheal peak pressure) in order to identify the effect of the intervention in the two groups. Endotracheal peak pressure was not significantly different between the two groups. Conclusion: Education and training of paramedic students in emergency medical services on single-rescuer respiratory-assistant therapy is necessary for the emergency care of patients with respiratory arrest.

Numerical Study on High-Speed railway Tunnel Entrance Hood (고속철도 터널 입구후드에 관한 수치해석적 연구)

  • 김희동;김동현
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.604-611
    • /
    • 1998
  • High-speed railway trains entering and leaving tunnels generate finite amplitude pressure wave which propagate back and forth along the tunnels, reflecting at the open ends of the tunnels and at other discontinuities such as ventilation shafts and the train themselves. In present day railways, the magnitudes of the pressure waves are much too small to cause structual damage, but they are a serious potential source of aural discomport for passengers on unsealed trains. Almost always do the pressure waves propagating along the tunnels lead to a hazardous impulse noise near the exit portal of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Desirable hood shape for reduction of the pressure transients and impulse noise was found to be of abrupt type hood with its cross-sectional area 2.5times the tunnel area.

  • PDF

Effects of Five-month Training of Playing Harmonica on Pulmonary Function in Patients With Neuromuscular Disease: A Pilot Study

  • Kim, Bit-na-rae;Cynn, Heon-seock
    • Physical Therapy Korea
    • /
    • v.25 no.3
    • /
    • pp.60-67
    • /
    • 2018
  • Background: Progressive muscle weakness is aggravated not only in the skeletal muscles but also in the respiratory muscles in many patients with neuromuscular diseases (NMD). Inspiratory muscle training (IMT) has been reported as therapy for pulmonary rehabilitation to improve respiratory strength, endurance, exercise capacity, and quality of life, and to reduce dyspnea. Objects: The purpose of this study was to determine the effect of playing harmonica for 5 months on pulmonary function by assessing the force vital capacity (FVC), peak cough flow (PCF), maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP), and maximal voluntary ventilation (MVV) in patients with NMD. Methods: Six subjects with NMD participated in this study. The subjects played harmonica once a week for 2 hours at a harmonica academy and twice a week for 1 hour at home. Thus, training was performed thrice a week for 23 weeks. The examiner assessed pulmonary function by measuring FVC in the sitting and supine positions and PCF, MIP, MEP, and MVV in the sitting position at the beginning of training and once a month for 5 months. Results: Both sitting and supine FVC significantly increased after playing harmonica (p=.042), as did MIP (p=.043) and MEP (p=.042). Conclusion: Playing harmonica can be used as an effective method to improve pulmonary function in patients with NMD.

Effect of Nozzle Geometry on the Suction Flow Rate in a Ejector (이젝터의 노즐 형상이 흡입유량에 미치는 영향)

  • Kim, Yoo-Jun;Park, Joung-Woo;Seo, Lee-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.6
    • /
    • pp.13-17
    • /
    • 2009
  • Ejector is an equipment devised for making use of the low pressure occurring from the fast fluid injection and it is a transportation equipment which can obtain vacuum using the kinetic energy of the fluid. This ejector system is, nowadays, widely used for construction machinery, heavy equipments, the cooling and ventilation of electronic devices and for the various fluid transportation and pumps. In this study, it is attempted to perform a numerical analysis and an experiment to find out the characteristics of fluid quantity, velocity and the pressure distribution of the induction pipe by changing the length and the radius ratio of the nozzle of ejector. From the results, it is investigated that the distributions of velocity and pressure of induction pipe attached are changing with the length and the radius ratio of the nozzle. In addition, it is shown that for the small and large ejector, the efficiency is the maximum when the length of the nozzle arrived to the neck of the ejector, however, if it is installed at below or above the neck the efficiency is rather decreased.

Prediction of Useful Life by Heat Aging of Motor Fan Isolating Rubber (모터팬 방진고무부품의 노화수명 예측)

  • Kim, W.S.;Woo, C.S.;Cho, S.J.;Kim, W.D.
    • Elastomers and Composites
    • /
    • v.37 no.2
    • /
    • pp.107-114
    • /
    • 2002
  • This paper discusses the accelerated heat aging tests were carried out to predict the useful life of EPDM isolating rubber components of ventilation fan motor for clean room. 20% compression set results changes as the threshold are used for assessment of the useful life and the time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. The useful life at variable temperatures and activation energy are obtained from the Arrhenius relationship. An accelerated test program to assess useful life can be represented an appreciable investment in time was designed. We also considered the effect of antioxidant agents.