• Title/Summary/Keyword: Ventilation condition

Search Result 445, Processing Time 0.027 seconds

Evaluation of Odor Dispersion from Livestock Building through Field Experiment (현장실험을 통한 축산시설로부터 배출되는 축산악취의 확산 평가)

  • Yeo, Uk-Hyeon;Lee, In-Bok;Ha, Tae-Hwan;Decano, Cristina;Kim, Rack-Woo;Lee, Sang-Yeon;Kim, Jun-Gyu;Choi, Young-Bae;Park, You-Me
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.21-30
    • /
    • 2019
  • Livestock odor is comprised of mixed type of odorous compounds. Among these, ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) are the two known major odor causing substances. Because high odor concentration reduces productivity of livestock and causes damage to the surrounding communities, quantitative analysis is needed to manage the odor inside and outside the livestock facilities. It is also necessary to evaluate odor dispersion according to the distance between the receptors taking into account the influence of odor source and weather condition. Therefore, in this study, we tried to evaluate the internal environment and odor dispersion from experimental pig house considering weather conditions. An experimental farm was specifically selected to eliminate the interference of odors generated by adjacent farms. $NH_3$ and complex odor were quantitatively analyzed using a gas detector and air dilution sensory method. The concentration of $NH_3$ and complex odor in pig house showed a distinct concentration difference according to the cleaning and ventilation conditions. $NH_3$ concentration and complex odor was lower than emission standard in the pig house and at the site boundary. The average $NH_3$ concentration (P1~P3) and the $NH_3$ concentration at the site boundary (S1) were strongly correlated with R=0.77. While the correlation for complex odor inside and at the site boundary had R=0.52. The correlation coefficient between $NH_3$ and the complex odor was 0.80.

Efficacy and tolerability of adjunctive perampanel treatment in children under 12 years of age with refractory epilepsy

  • Yun, Yuni;Kim, Dongsub;Lee, Yun-Jeong;Kwon, Soonhak;Hwang, Su-Kyeong
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.7
    • /
    • pp.269-273
    • /
    • 2019
  • Purpose: There is limited data on the use of perampanel in children under 12 years of age. We evaluated the efficacy and tolerability of adjunctive perampanel treatment in children under 12 years of age with refractory epilepsy. Methods: This retrospective observational study was performed in Kyungpook National University Hospital from July 2016 to March 2018. A responder was defined as a patient with ${\geq}50%$ reduction in monthly seizure frequency compared with the baseline. Adverse events and discontinuation data were obtained to evaluate tolerability. Results: Twenty-two patients (8 males, 14 females) aged 3.1-11.4 years (mean, $8.0{\pm}2.5years$) were included in this study. After an average of 9.2 months (range, 0.5-19 months) of follow-up, 15 patients (68%) showed a reduction in seizure frequency, including 5 patients (23%) with seizure freedom. The age at epilepsy onset was significantly lower (P=0.048), and the duration of epilepsy was significantly longer (P=0.019) in responders than in nonresponders. Nine patients (41%) experienced adverse events, including somnolence (23%), respiratory depression (9%), violence (4.5%), and seizure aggravation (4.5%). The most serious adverse event was respiratory depression, which required mechanical ventilation in 2 patients (9%). Eight patients (36%) discontinued perampanel due to lack of efficacy or adverse events. Three out of 4 patients (75%) who discontinued perampanel due to adverse events had an underlying medical condition. Conclusion: Perampanel offers a treatment option for refractory epilepsy in children. Adjunctive treatment with perampanel requires special consideration in those with underlying medical conditions to prevent serious adverse events.

Implement of Analysis system with Indoor Environment Monitoring Based on IoT (사물인터넷 기반 실내 환경 모니터링 분석 시스템 구현)

  • Nam, Jae-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1687-1692
    • /
    • 2019
  • In the era of the fourth industrial revolution, advanced technologies such as the Internet of Things(IoT) and big data are emerging. However, the level of application of IoT to indoor environment is very weak. Therefore, it is necessary to develop a system for analyzing air pollutants or indoor air quality through real-time monitoring using the IoT. This paper implements a system that measures indoor environmental values using Arduino and various sensors, and stores the information obtained from various sensors into a database of server. The information stored in the server was built as a database and utilized in the ventilation system or air cleaner installed in the home or company's room. In the proposed system, it is possible to check the immediate indoor environmental condition through the LED status display of the monitoring sensor module while reducing the cost of the sensor used to implement IoT technology.

Smart Closet based on Arduino MEGA (아두이노 메가 기반의 스마트 옷장)

  • Mun, Se-Hun;Lee, Ju-Hyon;Lee, Ji-Min;Park, Gun-Hee;Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.949-958
    • /
    • 2022
  • Modern people have many kinds of clothes for individuals, and not just for storing clothes, but also for managing the condition of the closet, and users of smart closets created smart closets that provide daily convenience and optimal closet conditions, suggesting the possibility of developing smart furniture for various environments. In this developed system, smart closet is controlled using app inventor and touch LCD through bluetooth wireless communication, based on Arduino MEGA and user's clothes is recommended depending on the weather. In addition, this smart closet is designed with real-time weather status checking and easy ventilation function. It was implemented through the Arduino and app inventor program so that the weather can be printed on the LCD screen and the user's suitable clothes can be recommended to the application.

Optimum arrangement of stiffener on the buckling behaviour of stiffened composite panels with reinforced elliptical cutouts subjected to non-uniform edge load

  • Kalgutkar, Akshay Prakash;Banerjee, Sauvik;Rajanna, T.
    • Steel and Composite Structures
    • /
    • v.42 no.4
    • /
    • pp.427-446
    • /
    • 2022
  • Cutouts in the beams or plates are often unavoidable due to inspection, maintenance, ventilation, structural aesthetics purpose, and sometimes to lighten the structures. Therefore, there will be a substantial reduction in the strength of the structure due to the introduction of the cutouts. However, these cutouts can be reinforced with the different patterns of ribs (stiffener) to enhance the strength of the structure. The present study highlights the influence of the elliptical cutout reinforced with a different pattern of ribs on the stability performance of such stiffened composite panels subjected to non-uniform edge loads by employing the Finite element (FE) technique. In the present formulation, a 9-noded heterosis element is used to model the skin, and a 3-noded isoparametric beam element is used to simulate the rib that is attached around a cutout in different patterns. The displacement compatibility condition is employed between the plate and stiffener, and arbitrary orientations are taken care by introducing respective transformation matrices. The effect of shear deformation and rotary inertia are incorporated in the formulation. A new mesh configuration is developed to house the attached ribs around an elliptical cutout with different patterns. Initially, a study is performed on the panels with different stiffener schemes for various ply orientations and for different stiffener depth to width ratios (ds/bs) to determine an optimal stiffener configuration. Further, various parametric studies are conducted on an obtained optimal stiffened panel to understand the effect of cutout size, cutout orientation, panel aspect ratio, and boundary conditions. Finally, from the analysis, it can be observed that the arrangement of the stiffener attached to a panel has a major impact on the buckling capacity of the stiffened panel. The stiffener's depth to width ratio also significantly influences the buckling characteristic.

Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs

  • Dalhae, Kim;Won-Gyun, Son;Donghwi, Shin;Jiyoung, Kim;Inhyung, Lee
    • Journal of Veterinary Science
    • /
    • v.23 no.6
    • /
    • pp.68.1-68.8
    • /
    • 2022
  • Background: Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. Objectives: This study evaluated the influence of RR on PPV in mechanically ventilated healthy dogs after hemorrhage. Methods: Five healthy adult Beagle dogs were premedicated with intravenous (IV) acepromazine (0.01 mg/kg). Anesthesia was induced with alfaxalone (3 mg/kg IV) and maintained with isoflurane in 100% oxygen. The right dorsal pedal artery was cannulated with a 22-gauge catheter for blood removal, and the left dorsal pedal artery was cannulated and connected to a transducer system for arterial blood pressure monitoring. The PPV was automatically calculated using a multi-parameter monitor and recorded. Hemorrhage was induced by withdrawing 30% of blood (24 mL/kg) over 30 min. Mechanical ventilation was provided with a tidal volume of 10 mL/kg and a 1:2 inspiration-to-expiration ratio at an initial RR of 15 breaths/min (baseline). Thereafter, RR was changed to 20, 30, and 40 breaths/min according to the casting lots, and the PPV was recorded at each RR. After data collection, the blood was transfused at a rate of 10 mL/kg/h, and the PPV was recorded at the baseline ventilator setting. Results: The data of PPV were analyzed using the Friedman test followed by the Wilcoxon signed-rank test (p < 0.05). Hemorrhage significantly increased PPV from 11% to 25% at 15 breaths/min. An increase in RR significantly decreased PPV from 25 (baseline) to 17%, 10%, and 10% at 20, 30, and 40 breaths/min, respectively (all p < 0.05). Conclusions: The PPV is a dynamic parameter that can predict a dog's hemorrhagic condition, but PPV can be decreased in dogs under high RR. Therefore, careful interpretation may be required when using the PPV parameter particularly in the dogs with hyperventilation.

Enteral Nutrition in Critically Ill Patient With Septic Shock Requiring Vasopressor: Case Report

  • Hee Young Kim;Min Young Noh;Jisun Lee
    • Clinical Nutrition Research
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Nutritional support in critically ill patients is an essential aspect of treatment. In particular, the benefits of enteral nutrition (EN) are well recognized, and various guidelines recommend early EN within 48 hours in critically ill patients. However, there is still controversy regarding EN in critically ill patients with septic shock requiring vasopressors. Therefore, this case report aims to provide basic data for the safe and effective nutritional support in septic shock patients who require vasopressors. A 62-year-old male patient was admitted to the intensive care unit with a deep neck infection and mediastinitis that progressed to a septic condition. Mechanical ventilation was initiated after intubation due to progression of respiratory acidosis and deterioration of mental status, and severe hypotension required the initiation of norepinephrine. Due to hemodynamic instability, the patient was kept nil per os. Subsequently, trophic feeding was initiated at the time of norepinephrine dose tapering and was gradually increased to achieve 75% of the energy requirement through EN by the 7th day of enteral feeding initiation. Although there were signs of feeding intolerance during the increasing phase of EN, adjusting the rate of EN resolved the issue. This case report demonstrates the gradual progression and adherence to EN in septic shock patient requiring vasopressors, and the progression observed was relatively consistent with existing studies and guidelines. In the future, further case reports and continuous research will be deemed necessary for safe and effective nutritional support in critically ill patients with septic shock requiring vasopressors.

A Case of Metapneumovirus Pneumonia-Related Acute Respiratory Distress Syndrome in a Young Adult Patient (젊은 성인 환자에서 인간 메타뉴모바이러스 폐렴에 의한 급성 호흡곤란증후군)

  • Tae Wan Kim;Won-Young Kim
    • The Korean Journal of Medicine
    • /
    • v.99 no.2
    • /
    • pp.111-115
    • /
    • 2024
  • Human metapneumovirus (hMPV) infections commonly present as mild upper respiratory tract infections in healthy adults, although severe respiratory complications have been observed, particularly in elderly and immunocompromised patients. We report a case in whom pneumonia caused by hMPV progressed to acute respiratory distress syndrome (ARDS) in a healthy adult without underlying diseases. A 31-year-old female presented with fever and dyspnea, prompting transfer to our hospital for mechanical ventilation 3 days after symptom onset. Auscultation revealed coarse breath sounds and crackles in both lung fields, and chest X-ray showed non-specific infiltrative nodules with poorly defined borders throughout both lungs. ARDS caused by community-acquired pneumonia was diagnosed. hMPV was identified via rapid testing of respiratory samples for genes that encode pneumonia pathogens and drug resistance markers; we employed reverse transcription polymerase chain reactions to these ends. Six days later, the patient was weaned off the mechanical ventilator, and discharged from the hospital in good clinical condition.

Legal Institutional Improvement Measures for Revitalization of Change in Building use Officetel to Lifestyle Lodging Industry (오피스텔의 생활형 숙박업 용도변경 활성화를 위한 제도적 개선방안 연구)

  • Ho, Han-Cheol;Song, Ho-Chang
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.455-465
    • /
    • 2014
  • This study focuses on some institutional improvement for revitalization of change in building use of officetel to lifestyle lodging industry. First as analysis method, this study establishes a failure factor for change in building use of officetel to lifestyle lodging industry. Second, analyzes an urgent importance to improve it in aspect of a legal institution or management for revitalizing a change of building use of officetel to lifestyle lodging industry. As a result, a failure factor of change in building use from officetel to lifestyle lodging industry is deducted in 4 articles with 13 detailed index. As a result of AHP, 'existing contractor's 100% agreement condition' is the first place, 'commercial /semi-residential area in zoning' is the second place, 'relative cleanup zone' is the fourth place, 'late changes of building use by a complex licensing procedure' is the fifth place, 'operational risk of consignment' is the sixth place, 'deficiency in publicity of related institution' is the eighth place, 'lack of concept in lifestyle lodging industry of building code' is the ninth place, 'basic constructional condition such as parking lot sewage and fire protection system' is the tenth plce, 'installation of ventilation facility' is the eleventh place, 'installation of bathroom and shower room in each room' is the twelfth place, 'installation of kitchen facility' is the thirteenth place.

A Study on the Wind Power Generation Using Vertical Exhaust Air Duct of the High-Rise Apartments (초고층 공동주택의 주방.욕실 배기 풍속을 풍력발전에 활용하는 방안)

  • Lee, Yong-Ho;Kim, Seong-Yong;Hwang, Jung-Ha;Park, Jin-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.1-10
    • /
    • 2012
  • The purpose of this study was to promote the utilization of wind velocity of kitchen and bathroom exhaust ducts for wind power generation in high-rise apartments. The research content can be summarized as follows: 1) Nine high-rise apartments were examined for the installation of kitchen and bathroom exhaust ducts located in the pipe shaft (PS) section. After selecting simulation candidates, a simulation was performed with the STAR-CCM+ Ver 5.06 program. 2) Of nine high-rise apartments, seven had kitchen and bathroom exhaust ducts, whose cross section was in the range of $0.16m^2{\sim}0.4m^2$. The area ratio between the exhaust ducts and PS section (cross section of exhaust duct/area of PS section ${\times}$ 100) was on average 3.2%. 3) The simulation results were analyzed. As a result, the smaller cross section kitchen and bathroom exhaust ducts had, the more advantages there were for increasing exhaust wind velocity. If an out air inlet duct is installed to the old kitchen and bathroom exhaust ducts, it will increase exhaust wind velocity by 3.01~3.98m/s and contribute to the proper wind velocity level (3.0m/s). 4) When the simultaneous usage rate between the kitchen and bathroom exhaust fan increased from 20% to 60%, exhaust wind velocity increased. The "entire house holds" condition for exhaust fan operation provided more even exhaust wind velocity than the "some house holds" condition. 5) Exhaust wind velocity increased in the order of amplified (T-3), induced (T-2) and vertical (T-1) top of kitchen and bathroom exhaust ducts. Of them, the amplified type (T-3) was under the least influence of external wind velocity and thus the most proper for kitchen and bathroom exhaust duct tops.