• 제목/요약/키워드: Ventilation condition

Search Result 443, Processing Time 0.027 seconds

A Numerical Study on Smoke Movement in Longitudinal Ventilation Tunnel Fires Using a Zone Model (존 모델을 이용한 종류식 배연 터널 화재시 연기 거동에 대한 수치해석적 연구)

  • Kim, Hyun-Jeong;Roh, Jae-Seong;Kim, Dong-Hyeon;Jang, Yong-Jun;Ryou, Hong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1319-1324
    • /
    • 2007
  • Many researches have been performed to analyze the smoke movement in tunnel fires by using field model. Recently, FDS(Fire Dynamics Simulator) v.4, which is one of the field model and developed from NIST(National Institute of Standards and Technology), is widely used. In tunnel fires, FDS can show detail results in local point, but it has difficulties in boundary condition and taking long computing time as the number of grid increases. So, there is a need to use alternative method for tunnel fire simulation. A zone model is different kind of CFD method and solves ordinary differential equation based on conservation and auxiliary equations. It shows good macroscopic view in less computing time compared to field model. In this study, therefore, to confirm the applicability of CFAST in tunnel fire analysis, numerical simulations using CFAST are conducted to analyze smoke movement in longitudinal ventilation reduced-scale tunnel fires. Then the results are compared with experimental results. The differences of temperature and critical velocity between numerical results and experimental data are over $30^{\circ}C$ and 0.9m/s, respectively. These values are out of error range. It shows that CFAST 6.0 is hard to be used for tunnel fire simulation.

  • PDF

Evaluation of the Performance and the Energy Consumption Characteristics of Heat Recovery Ventilators in Apartments (공동주택 열교환기의 성능 및 에너지소비 특성 평가)

  • Kim Sang-Min;Park Byung-Yoon;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.496-504
    • /
    • 2005
  • Heat recovery ventilators (HRV) are developed in order to satisfy both energy conservation and the improvement of indoor air quality as an alternative for current natural ventilation systems and local mechanical ventilation systems in kitchens and bathrooms. However, the performance of HRV system and the consequent effect on heating and cooling energy saving have not been sufficiently validated quantitatively in case of the application of HRVs in real residences. In this study, field measurement and computer simulation were conducted in both summer and winter period to assess the performance and validate energy conservation effect of HRVs. Under the Korea weather condition, average total heat recovery efficiency was $27\%$ in summer and $46\%$ in winter. According to the field measurement, HRV system can save the energy by $10\%$ in summer and 15$\%$ in winter. Furthermore, according to the simulation assessment, HRV system can save the energy by $17\%$ in summer and $17\%$ in winter.

Effect of the Floor on the Ventilation Performance of the Vortex Vent (바닥의 위치가 Vortex Vent의 배기성능에 미치는 영향)

  • Lee, Jin-Won;Lim, Young-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.154-158
    • /
    • 2009
  • The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV can enhance the capture depth by a factor of 3-5 compared to the conventional exhaust hood, in the absence of any solid walls nearby. In real situations there may exist ceiling, side wall and floor, all of which can affect the flow field and suction performance by way of the no-slip condition on the walls. 3D CFD simulation was performed in order to see the effect of the floor on the capture performance of the VV. The presence of floor reduced suction flow velocity, and increased the critical rotational speed which is the rotational speed required for stable vortex formation. Flow velocity profile along the axis could be well approximated by a universal functional form when the distance from the exhaust inlet is non-dimensionalized by the distance to the floor. Capture depth, define by the distance from the exhaust inlet to a point of velocity decreased to 10% of that at the inlet, is reduced by about 10% when the floor distance is 6 times the exhaust hood diameter.

  • PDF

A Study on exposure-Worker to Formaldehyde in the Endoscopy Unit of Hospitals (일부 종합병원 내시경실 근무자의 포름알데히드 노출에 관한 연구)

  • Kim, Jeong Hun;Kim, Dae-Jong;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2009
  • To identify relationship between the airborne concentrations of formaldehyde and the causal factors in the endoscope unit of hospitals, a total of 48 workers selected from 4 hospitals (3 university hospitals and 1 national hospital) were investigated. Airborne formaldehyde samples were collected using passive samplers and subsequently analyzed by HPLC according to the OSHA method 1007. The geometric mean(GM) of airborne formaldehyde concentrations was 0.056 ppm (range: 0.003~0.923 ppm). The rates of exceeding exposure limits of OSHA PEL-TWA and NIOSH REL-TWA were 4.2 % and 83.3%, respectively. The STEL GM concentration was 1.428 ppm(range: 0.103~14.773 ppm). Ventilation condition (p=0.001) and temperature (p=0.017) were statistically significant causal factors for the airborne exposure concentration of formaldehyde in the endoscope unit of hospitals. In conclusion, the workers in the endoscope unit of hospitals were highly exposed to formaldehyde, and adequate controls such as appropriate management of ventilation and temperature are recommended to reduce over exposure to formaldehyde.

A Study on Ventilation Characteristics of LNG Carrier Hood room by PIV and CFD (PIV와 CFD에 의한 LNG선박의 Hood room 환기특성에 관한 연구)

  • Cho, D.H.;Kim, D.C.;Kim, M.E.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.673-679
    • /
    • 2000
  • LNG Carriers are currently known as sole commercial means of shipping natural gas on the sea. They are designed to proven dangerous explosion for shipping a lot of gas over long distance. In this study. In this study, a scaled model chamber was made to investigate ventilation characteristics of the hood room in LNG carrier. Experimental study was performed in model using visualization equipments with laser apparatus and image intensifier CCD camera gated by an AOM controller Twelve different kinds of measuring area were selected as experimental condition. Instant simultaneous velocity vectors at whole field were measured by using 2-D PIV system which software adopts two-frame grey-level cross correlation algorithm. To look into stagnation area of hood room for LNG carrier, a three-dimensional numerical simulation with standard ${\kappa}-{\varepsilon}$ model was carried out by using PHOENICS for three kinds of Reynolds number, $6.5{\times}10^3$, $9.7{\times}10^3\;and\;1.29{\times}10^4$, based on the cavity inlet velocity and cavity height. The flow pattern showed the large scale counter-clockwise forced-vortex rotated at center area, small eddies at each corner and stagnation area located at left-back upper side of model.

  • PDF

The Survey for Environmental Management of Korea Detector Dog (국내 탐지견의 환경 및 위생 관리 현황 조사)

  • Lee, Eun-Chae;Jeong, Ha-Jeong;Hwang, Seong-Gu;Lee, Sang-Rak
    • Journal of Animal Environmental Science
    • /
    • v.20 no.4
    • /
    • pp.177-182
    • /
    • 2014
  • This research was conducted to grasp the present condition of environmental management relating to Korea detector dogs that performed their duties such as detection and lifesaving. We directly conducted a survey throughout visit to five government agencies. In environmental management case, average length and width of kennels were 1.78 m and 3.50 m, respectively. Types of floor were searched as coating cement, tile, ucrete and concrete. Most of government agencies ventilated kennels using ventilation fan systems with natural ventilation. But there were differences between government agencies in frequencies of the sanitary management items. On the other side, major diseases of the German shepherd breed as a major detector dog were in order of arthritis, measles, earache, and dermatosis. And their daily training time was average 4 hours. Finally, it is thought that these results could be used as a basic data of standard breeding management manual of Korea detector dog.

Effect-site Concentration of Alfentanil or Remifentanil for the Relief of Postoperative Pain in the Intensive Care Unit Patients

  • Jang, Hae-Lan;Kang, Hoon
    • International Journal of Contents
    • /
    • v.11 no.2
    • /
    • pp.69-73
    • /
    • 2015
  • This study was performed to determine the optimal doses of alfentanil or remifentanil (effect-site concentrations) required to prevent pain and other suffering after abdominal general surgery in ICU patients. A total of 52 general abdominal surgical patients (ASA IIIII) requiring artificial ventilatory care in the ICU were provided with either alfentanil (24 patients) or remifentanil (28 patients) through target controlled infusion (TCI). Alfentanil and remifentanil concentrations were titrated up and down until the pain score became less than 3 (VAS; Visual Analogue Score < 3). The effect-site concentrations (ng/ml) of alfentanil or remifentanil required to adequately control postoperative pain in the ICU were 64 +/- 12 and 1.9 +/- 0.5 for intubation with artificial ventilation, 57 +/- 9 and 1.7 +/- 0.7 for intubation with spontaneous ventilation, and 41 +/- 10 and 1.2 +/- 0.5 after extubation, respectively. Pain scores and the corresponding opioid concentrations were independent from respiratory condition. The three effect-site concentrations of alfentanil and remifentanil obtained from this clinical trial using the TCI technique can be a guideline in the administration of the same opioids to relieve the discomfort of ICU patients who have undergone abdominal general surgery.

Estimation of Source Emission Rate on Volatile Organic Compounds and Formaldehyde Using Indoor Air Quality Modeling in New Apartment (실내공기질 모델을 이용한 신축공동주택의 VOCs 및 HCHO 배출량 추정)

  • Sim, Sang-Hyo;Kim, Yoon-Shin;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.10
    • /
    • pp.929-933
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time Indoors. Especially when indoor environments have sources of contaminants, exposure to in-door air can potentially pose a greater threat than exposure to ambient air. In this study, estimations of volatile organic compounds and formaldehyde omission rate in indoor environments of new apartments were carried out using mass balance model in indoor environment, because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. Considering the estimated emission rate of volatile organic compounds and formaldehyde, it Is suggested that new apartment should be designed and constructed in the aspect of using construction materials to emit low hazardous air pollutants.

Study of HVAC system with air cleaning system for indoor air quality of subway station (지하철 역사의 실내공기질 개선을 위한 공조기 적용 공기청정장치 선정에 대한 기초연구)

  • Jung, Yee-Kyeong;Park, Jae-Hong;Lee, Ryang-Hwa;Yoon, Ki-Young;Hwang, Jung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.537-540
    • /
    • 2008
  • A numerical study has been carried out on the optimization of an air cleaning system which was installed in a heating, ventilation and air conditioning system (HVAC) system of subway station for particle removal. Required particle removal efficiencies of three different air cleaning systems were calculated from ventilation rate, and indoor/outdoor concentration of PM10. Mass balance equations of PM10 were used to solve the required particle removal efficiencies. Fibrous filter was considered as an air cleaning system. Calculations were carried out about two different places which were waiting area and platform of subway station, respectively. This study proposed optimized design and operation condition of each air cleaning system.

  • PDF

Electrical fire simulation in control room of an AGN reactor

  • Jyung, Jae-Min;Chang, Yoon-Suk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.466-473
    • /
    • 2021
  • Fire protection is one of important issues to ensure safety and reduce risks of nuclear power plants (NPPs). While robust programs to shut down commercial reactors in any fires have been successfully maintained, the concept and associated regulatory requirements are constantly changing or strengthening by lessons learned from operating experiences and information all over the world. As part of this context, it is necessary not only to establish specific fire hazard assessment methods reflecting the characteristics of research reactors and educational reactors but also to make decisions based on advancement encompassing numerical analyses and experiments. The objectives of this study are to address fire simulation in the control room of an educational reactor and to discuss integrity of digital console in charge of main operation as well as analysis results through comparison. Three electrical fire scenarios were postulated and twenty-four thermal analyses were carried out taking into account two turbulence models, two cable materials and two ventilation conditions. Twelve supplementary thermal analyses and six subsequent structural analyses were also conducted for further examination on the temperature and heat flux of cable and von Mises stress of digital console, respectively. As consequences, effects of each parameter were quantified in detail and future applicability was briefly discussed. On the whole, higher profiles were obtained when Deardorff turbulence model was employed or polyvinyl chloride material and larger ventilation condition were considered. All the maximum values considered in this study met the allowable criteria so that safety action seems available by sustained integrity of the cable linked to digital console within operators' reaction time of 300 s.