• 제목/요약/키워드: Ventilation condition

검색결과 444건 처리시간 0.024초

유해물질 제거를 위한 국소배기장치 후드의 흡입력 증가에 관한 연구 (A Study on Inhalation Force Improvements of Ventilation Hood For Removed a Pollution Source)

  • 양호동;김영선;오율권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2327-2332
    • /
    • 2007
  • This study investigates on the inhalation force improvements of hood consisted one of the local ventilation systems attached the new device named as gas-guidance-device for removed a pollution source. The numerical method applying finite element method is calculated the velocity and pressure distributions of a moving fluid at the beginning and the inside of a hood with and without the gas-guidance-device in hood. And, the experimental study is measured the wind velocity using the anemometer at the same condition of numerical study. Also, the optimum shape of gas-guidance-device which is suitable for hood shape derived from the numerical and experimental results. The results of this study is supplied the important data to an industrial field for control of a pollution source in the engineering aspect. Moreover, the introduced technique of hood attached the gas-guidance-device is very useful to remove the harmful materials such as dust and waste happened in the manufacturing factory.

  • PDF

차내 환기구 형상변화에 대한 연구 (A Study ono the Type-Change of Automotive Register)

  • 김종원;윤종갑;배한;원성필
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.123-134
    • /
    • 1999
  • Nowadays since the automobile is regarded as the third living space, comfortable conditions are required in the passenger compartment. The customer's concern on air-conditioning/heating, ventilation and demisting/defrosting performances has been much increased. Both ventilation and demisting /defrosting performances are directly influenced by register location, shape of regist guide vane, ventilation flow rate, air distribution , and air circulation pattern. Diffuse plume of air from the register is desirable not only to maintain comfort when the comfort when the comfortable condition has been satisfied but to improve demisting /defrosting performance. In this study, experimental and numerical investigation about the flow field of six different register vane types were carried out , respectively. The numerical analysis, based upon the $textsc{k}$-$\varepsilon$ turbulence model , was applied to the air flow field. The results show that the shape of register guide vane should be considered as an important design paramter.

  • PDF

터널 환기용 제트홴의 성능 향상을 위한 수치최적화 (Numerical Optimization for Performance Improvement of a Tunnel Ventilation Jet fan)

  • 김준형;김진혁;김광용;윤준용;최영석;양상호
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.63-68
    • /
    • 2011
  • This paper presents an optimization procedure for performance improvement of a tunnel ventilation jet fan. Optimization techniques based on response surface approximation (RSA) are employed to improve the aerodynamic performance of a tunnel ventilation jet fan. For numerical analysis, three-dimensional Renolds- averaged Navier-Stokes (RANS) equations with shear stress transport turbulence model are discretized by using finite volume approximations and solved on hexahedral grids to evaluate the total efficiency at the operating condition as the objective function. Four geometric variables defining the meridional length and the thickness profile at the hub and shroud in the jet fan rotor are selected as design variables for the numerical optimization. The results of the numerical optimization show that the total efficiency of the optimized model is significantly improved in comparison with the base model.

Gas Fuelled Ship FGS 시스템에 대한 가스누출 조건 검토 및 CFD 해석 (Gas Leakage Condition and CFD analysis on Gas Fuelled ship FGS system)

  • 김기평;강호근;박재홍;정정호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2011
  • According to the requirement of Res.MSC.285(86) for natural gas-fueled engine installations in ships, pump and compressor rooms should be fitted with effective mechanical ventilation system of the under pressure type, providing a ventilation capacity of at least 30 air changes per hour. It generally considered that gas leakage is more likely from a Fueled Gas Supply System(FGS) room as compared to other places, where installed in many kind of machinery or equipments like gas supply high-pressure pipes, valves, flanges and etc. Furthermore, leaked gas may be dispersed in a short time in an enclosed space, especially a FGS room, due to high pressure. However, the present requirement in Res.MSC.285(86) just considers the ventilating capacity of air changes per hour but the capacity of leaked gas. Hence, the current requirements may not meet effectively when enforcing the new propulsion systems as marine fuel. This study is conducted for the purpose of safety evaluation about the dispersion and ventilation efficiency with estimated leakage scenario. Numerical analysis predictions as the result of this paper are explained to know the features of flow pattern and the diffusion of natural gas concentration.

  • PDF

건축물의 대공간 집회시설의 실내공기질 개선방안에 관한 연구 (A Study of the Indoor Air Quality Improvement for Large Scale Assembly Facilities)

  • 임태섭;강승모
    • 한국실내디자인학회논문집
    • /
    • 제20권4호
    • /
    • pp.183-190
    • /
    • 2011
  • Lately majority of churches have preferred to enlarge their worship area to both horizontal and vertical axis. According to expand their area which brings more devotees to the limited service area. Transform from a small church into a large church is no longer unprecedented issue in South Korea. As the size of church getting bigger, many unexpected issues become matters. One of the significant problem is that the number of people have experienced either fall a sleep or feel a doziness during their service period. Due to the limited condition for the specific building type such as religion facility(church), IAQ improvements is seriously concerned. Therefore, we are going to examine by using simulation tool, CF, a difference of ventilation efficiency about the location and number of windows, and find the best way of the ventilation efficiency in a multi-stories type church by changing the exhaust pipes location and size. Furthermore, in this thesis, by changing a ceiling height from the existing building to confirm that $CO_2$ have been satisfied for both the ventilation efficiency and IAQ.

신축 공동주택 베이크 아웃시 환기.습도 변화에 따른 실내오염물질 저감비교 (Studying indoor contaminant value according to vary ventilation and humidity, when operating bake-out on a new apartment)

  • 조연효;신성우;이지원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.702-707
    • /
    • 2008
  • Improving quality of life and wellbeing of the residential environment and increased interests and importance is growing confidentiality, insulation, high-rise due to a lack of ventilation and indoor air pollution. Several human diseases caused tremendously due to the indoor air which consists of formaldehyde, radon, pollutants such as volatile substances that is called the phenomenon of a new house syndrome. It has become a world-wide issue that the United States, Japan and several other countries of Europe are showing more interests. Furthermore, a lot of damages caused by the syndrome occurs in the new house should be resolved by somehow is urgent. Thus, this study would like to propose the measures based on the whether condition and the way of heating in korea against a new house syndrome via analysis of indoor contaminant Reduction comparison according to vary ventilation and humidity when operating bake-out on a new apartment.

  • PDF

CFD 툴을 활용한 패키지형 수소충전시스템의 안전성 향상 연구 (A Study on the Safety Improvement by CFD Analysis for Packaged Type Hydrogen Refueling System)

  • 황순일;강승규;허윤실
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.243-250
    • /
    • 2019
  • In this study, to ensure the safety of the packaged hydrogen refueling system, the improvement plan was derived by using 3-dimensional CFD program (FLACS). We also confirmed the effectiveness of risk reduction and the suitability of safety standard. By ventilation performance evaluation according to the position of the vent, it demonstrated that the vent should be installed at the ceiling to safely ventilate without stagnation of the leaked gas. In case of ventilation system according to KGS standard, risk situation could be resolved after about 5 minutes in the worst leaked condition. The result showed that jet fire and explosion inside the packaged system could affect the surrounding facilities. This proves that the standard for installing flame detectors, emergency shut down system and protection wall is appropriate.

겨울철 학교교실의 실내열.공기환경 실태와 학생들의 주관적 반응 (A Study of Indoor Thermal and Air Quality in Middle and High School Classrooms during Winter)

  • 최윤정;나선희;조수연
    • 한국생활과학회지
    • /
    • 제18권2호
    • /
    • pp.509-522
    • /
    • 2009
  • This is a basic study to improve air quality of school classrooms in winter time. The purposes are to check indoor thermal and air environment in school classrooms during winter and to analyze influencing factors on indoor environment. The measurements of students' physical elements with questionnaire surveys were carried out in a total of 6 classrooms. As a result, this research shows that the temperature of one classroom was below indoor thermal standard level, three classrooms had lack of heat, and two classrooms are heated much, which induce relatively low humidity. All of 6 classrooms had lack of ventilation, being high level of $CO_2$ concentration and 2 classrooms are in condition of high PM10 concentration. The majority of students(76%) answered that the cause of their 'heated space syndrome' is because of the lack of ventilation. Students' opening windows for ventilations is hardly carried out at normal times, except that indoor temperature is over standard. That is, we can suggest one of solutions, which is to enable students to operate heating and ventilating system by themselves according to students' physical condition.

배기열 회수용 종이 열교환기의 성능에 영향을 미치는 인자에 관한 연구 (A Study on the Factors Affecting the Performance of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 정민호;유성연
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.956-964
    • /
    • 2005
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery The purpose of this research is to find the factors affecting the performance of paper heat exchanger for exhaust heat recovery, which can be applied directly to the conventional ventilation unit, air-purifier, and air-conditioning system. In this study, thermal performance and pressure loss of the paper heat exchanger are measured and compared at various operating conditions. The effectiveness of sensible, latent and total heat at the face velocity of 0.75 m/s are $77\%,\;47\%\;and\;57\%$ in the cooling condition and $77\%,\;59\%,\;and\;\%$ in the heating condition, respectively. The effectiveness for sensible heat is only affected by velocity. On the other hand, the effectiveness for latent heat is affected. by temperature and relative humidity.

치과병·의원 환기방법에 따른 실내공기질 자각증상 수준 및 근무환경 만족요인 (A Subjective Symptom Level and Satisfaction Factor by Indoor Air Quality According to Ventilation System in Dental Clinic)

  • 최미숙;지동하;최재호
    • 치위생과학회지
    • /
    • 제11권4호
    • /
    • pp.353-359
    • /
    • 2011
  • 본 연구는 치과위생사가 근무하는 병원의 미세먼지(PM-10), 포름알데히드(HCHO), 이산화탄소($CO_2$), 일산화탄소(CO), 휘발성유기화합물(VOCs) 등에 의해 오염된 실내공기가 치과위생사의 건강 및 작업능률에도 많은 영향을 끼친다는 사실을 인식하여 치과위생사를 대상으로 근무하는 병원의 냉 반방 방식 및 창문개폐를 통한 환기 횟수에 따른 실내공기질에 대한 신체자각증상 정도를 비교하고, 근무하는 병원의 실내공기질과 관련된 환경 만족에 미치는 요인을 분석하므로써 치과위생사의 건강관리를 위한 효율적인 근무환경개선방안을 제시하기 위하여 시도되었다. 조사대상자는 전국 치과병 의원에 근무하는 치과위생사로 하였으며 2010년 10월 1일 부터 2011년 1월 21일까지 자기기입식 설문조사 방식으로 582부의 설문지를 수집하여 SPSS 12.0 프로그램을 이용하여 분석하였다. 1. 냉 난방 방식별 창문 개폐를 통한 하루 환기 횟수를 비교한 결과 창문개폐를 통한 환기가 편리한 개별 냉 난방 방식에서 높은 것으로 나타났다. 2. 치과위생사는 실내공기질과 관련된 자각증상으로 인하여 불편함을 가장 많이 느끼는 시간은 오후 2시 전 후이며 불편함을 느끼기 시작한 지 1시간 경과 후인 3시 전 후에 불편함의 정도가 가장 심한 것으로 조사되었다. 3. 치과위생사의 자각증상에 따른 불편함 수준을 냉 난방 방식 및 하루 창문개폐를 통한 환기 횟수와 비교하여 분석한 결과 창문 개폐를 이용하여 자연환기가 유리한 개별 냉 난방 방식의 사무실에 근무하는 치과위생사의 수준이 낮은 것으로 나타났다. 4. 근무하는 병원의 만족에 미치는 요인을 실내공기 조건과 관련된 항목을 독립변수로 하여 중회귀 분석을 실시한 결과 "병원 공기의 냄새가 기분 좋게한다", "병원 실내 온도조건은 근무하기에 편하다", "병원의 조명은 일하기에 적당한 편이다", "병원의 환기가 잘 된다", "병원 시끄러움", "병원공기가 신선하다고 느낀다", "병원 더움" 순으로 유의하게 나타났으며 설명력은 42.9%인 것으로 나타났다.