• Title/Summary/Keyword: Ventilation Noise

Search Result 129, Processing Time 0.027 seconds

Identification of noise characteristics of an automobile alternator (승용차용 교류발전기의 소음 특성 규명)

  • 정진태;서상준;은희준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.40-47
    • /
    • 1989
  • Alternator noises are composed of magnetic noise, mechanical noise, and ventilation noise. These noises depend on the design of magnetic parts and fans, the machining accuracy of each element, and assembled conditions. In running alternator there are various exciting forces which can generate noises and vibrations. In order to identify the noise sources of the alternator, the characteristics of noises and vibrations are analyzed as rotating speed is increased. And the experiment for structural vibration is carried out. From results of experimental study, the noise sources are identified and their contributions to the overall noise level are investigated. Their results can lead the instruction to the noise reduction on the alternator.

A Study on the Fan and Scroll for Ventilation (배기용 Fan Scroll에 대한 연구)

  • Song, S.B.;Park, S.I.;Lee, J.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.402-406
    • /
    • 2000
  • In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

  • PDF

Development of Ventilation Silencer for Noise Reduction of Apartments (공동주택 층간소음 저감을 위한 환기장치용 소음기 개발)

  • Oh, J.W.;Lee, J.S.;Lee, J.H.;Lee, S.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1247-1251
    • /
    • 2006
  • 공동주택의 보급 증가에 따라 화장실과 같이 환기용 덕트를 통한 층간 소음전달 문제가 예상되어 환기용 덕트에 간단히 설치하여 층간 소음 전달을 차단할 수 있는 환기장치용 소음기를 개발하였다. 본 개발품은 소음 차단 기능이 확실하고, 구조가 간단하며 분해조립이 가능하여 설치 및 유지보수가 용이한 제품이다. 또한 습기에 의한 부식이 없고, 먼지와 습기를 쉽게 제거할 수 있는 특징이 있다. 성능시험 결과 환기용 덕트를 통한 소음의 전달을 10dB 이상 저감시킬 수 있고, 삽입에 의한 압력손실 2mmAq 이하가 됨을 확인하였다.

  • PDF

Impact of Soundproofing Wall of Tunnel on Particulate Matter and Noise (서울시 터널 내 방음벽 설치가 입자상 물질 농도 및 소음 수준에 미치는 영향)

  • Cho, Hyun-Woo;Lee, Ji-Yeon;Liu, Xiaoshan;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.411-417
    • /
    • 2010
  • The Seoul metropolitan government has installed soundproofing walls in road tunnels to improve the tunnel environment for pedestrians. To evaluate the efficiency of these soundproofing walls, we measured noise levels and concentrations of $PM_{2.5}$ and ultrafine particles (UFP) in tunnels with or without these walls. Although noise and UFP levels were significantly lower in the tunnels with soundproofing walls, $PM_{2.5}$ levels were significantly higher: but were significantly lowered by use of a ventilation system. When $PM_{2.5}$ and noise levels were simultaneously measured in a tunnel with soundproofing wall, noise level was significantly reduced but $PM_{2.5}$ level was significantly higher. It is concluded that the soundproofing wall can protect pedestrians from noise, but not PM. Installation of a ventilation system is recommended for protection of pedestrians in tunnels with soundproofing walls.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

Tests on Ventilation Control of PRAIRIE for Improving Acoustic Stealth Performance (음향스텔스 성능 향상을 위한 PRAIRIE 공기 분사량 제어 실험)

  • Lee, Heechang;Moon, Youngsun;Kang, Seunghee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.602-608
    • /
    • 2020
  • PRAIRIE(Propeller Air Induced Emission) system is a kind of underwater radiated noise suppression systems to reduce the probability of the identification or classification of our warship's acoustic signature by an enemy ship. It is effective in case of strong cavitation events. This is because air bubbles emitted from the PRAIRIE system mitigate drastic collapses of the cavity bubbles that can generate an intense shock wave. However, when the PRAIRIE system is operated in a non or weak cavitation condition, it might increase the total level of underwater radiated noise and induce the acoustic signatures. Therefore, this paper presents the trial results on ventilation control of PRAIRIE to find a more efficient operation depend on the cavitation condition. Then, we show a variation of the amplitude modulation characteristics according to ventilation control.

A Study on Low Noise Cooling/Ventilation System for Large Electric Motor (대형 전동기 냉각/통풍 시스템의 저소음화 연구)

  • Jo, Hye-Young;Jang, Ji-Sung;Kim, Dong-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.973-974
    • /
    • 2014
  • 대형 전동기의 주요 소음원은 전자기 소음과 냉각/통풍 시스템 소음이며, 이 중 냉각/통풍 시스템이 전체 소음에 큰 영향을 미친다. 본 논문에서는 대형 전동기의 저소음 냉각/통풍 시스템 개발을 위해 저소음 냉각 팬을 개발하고 팬 커버 내부의 유로를 개선하였다. 유동해석은 상용 CFD 소프트웨어를 이용하였으며 팬 커버 내의 scroll 형상 및 air guide, baffle 의 유무에 따라 팬 커버의 압력손실을 계산하였다. 해석을 통해 팬 커버 내부의 난류 유동과 압력손실이 가장 작은 팬 커버 형상을 도출하였으며 개선된 냉각/통풍 시스템이 기존 냉각/통풍 시스템보다 6.5dB 감소된 것을 확인하였다.

  • PDF

Development and Evaluation for Improvement of the Sound Insulation of Balcony Window in Apartment (차음성능 향상을 위한 발코니 창호의 개발 및 평가)

  • Kim, Ha-Geun;Kim, Myung-Jun;Oh, Jin-Kyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.5 s.98
    • /
    • pp.519-526
    • /
    • 2005
  • Recently, the interest on the comfortable dwelling environment is increasing and the effort to solve the problem of exterior noise was tried. The propose of this study is to suggest the design of balcony window in apartment and to evaluate the sound insulation of it. So, we designed five types of balcony window which were considered not only sound insulation but ventilation. The sound reduction index of window was evaluated by the measurement in mock-up room. The results showed that case 2 improved about 6 dB in the weighted apparent sound reduction index than case 1, and case 3 reduced about $39 \%$ in construction cost than case 4.

Development and Evaluation for Improvement of the Sound Insulation of Balcony window in Apartment (차음성능 향상을 위한 발코니 창호의 개발 및 평가)

  • Oh, Jin-Kyun;Kim, Ha-Geun;Kim, Myung-Jun;Kim, Yun-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.445-450
    • /
    • 2004
  • Recently, the interest on the comfortable dwelling environment is increasing and the effort to solve the problem of exterior noise was tried. The propose of this study is to suggest the design of balcony window in apartment and to evaluate the sound insulation of it. So, we designed five types of balcony window which were considered not only sound insulation but ventilation. The sound reduction index of window was evaluated by the measurement in mock-up room. The results showed that case 2 improved about 6dB in the weighted apparent sound reduction index than case 1, and case 3 reduced about 39% in construction cost than case 4.

  • PDF

Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System (다기능온돌시스템을 이용한 자연환기성능 평가)

  • Cho, Dong-Woo;Yu, Ki-Hyung;Yu, Jung-Yeon;Jung, Hae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF