• 제목/요약/키워드: Ventilation Fan

검색결과 279건 처리시간 0.022초

다수의 열원을 가지는 공간에서의 환기 조건에 따른 열환경 해석 (Thermal Environment Analysis of a Room in Accordance with Ventilation Condition with Multi-Heat Sources)

  • 김재중;손영갑;장석원;유동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.199-204
    • /
    • 2000
  • This paper reports a thermal environmental analysis of a room in accommodated with multi-heat sources according to ventilation condition. Two case modification have been investigated to obtain the lower temperature distribution in the room. The temperature distribution of the original room were found about $25{\sim}35^{\circ}C$. As a result, the use of, three ventilating fans and two electric fans are useful for room ventilation respectively, and using two electric fan is more recommendable in side of economical efficiency.

  • PDF

돈사용 환기팬을 위한 돈사 내 온도 분포 특성 (Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System)

  • 김현태;김웅
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

CFD-based Design and Analysis of the Ventilation of an Electric Generator Model, Validated with Experiments

  • Jamshidi, Hamed;Nilsson, Hakan;Chernoray, Valery
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권2호
    • /
    • pp.113-123
    • /
    • 2015
  • The efficiency of the ventilation system is a key point for durable and reliable electric generators. The design of such system requires a detailed understanding of the air flow in the generator. Computational fluid dynamics (CFD) has the potential to resolve the lack of information in this field. The present work analyses the air flow inside a generator model. The model is designed using a CFD-based approach, and manufactured by taking into consideration the experimental and numerical requirements and limitations. The emphasis is on the possibility to accurately predict and experimentally measure the flow distribution inside the stator channels. A major part of the work is focused on the design of an intake and a fan that gives an evenly distributed flow with a high flow rate. The intake also serves as an accurate flowmeter. Experimental results are presented, of the total volume flow rate, the total pressure and velocity distributions. Steady-state CFD simulations are performed using the FOAM-extend CFD toolbox. The simulations are based on the multiple rotating reference frames method. The results from the frozen rotor and mixing plane rotor-stator coupling approaches are compared. It is shown that the fan design provides a sufficient flow rate for the stator channels, which is not the case without the fan or with a previous fan design. The detailed experimental and numerical results show an excellent agreement, proving that the results reliable.

DMF를 사용하는 합성피혁 공장 인쇄공정의 산업환기시스템 평가 및 개선 (A Valuation and Improvement of Industrial Ventilation System of Printing Process in Synthetic Leather Factory using Dimethylformamide)

  • 이선우;김태형;김정만;김종철
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.113-126
    • /
    • 2009
  • In the recent years, health effect of dimethylformamide(DMF) has been one of critical industrial hygiene issues. There might be many factors to increase the exposure level of DMF. Among those factors, industrial ventilation would be one of the main factors. In this study, industrial ventilation systems of printing processes in synthetic leather factories were thoroughly surveyed and the improved ventilation systems were proposed. 7 synthetic leather factories were selected for this study. After the ventilation systems were visually inspected, each component of the system was tested by using the appropriate instruments. Hood face velocities, fan exhaust flow rates, fan static pressures, fan rotation rates, etc were measured. In addition, flow visualization techniques were used to observe flow patten around hoods and inside the factory buildings. After gathering all qualitative and quantitative information, the test results were analysed to see if any improvement might be necessary. For the system to be improved, the re-design plans were made by using computational fluid dynamics softwares. The softwares used in this study were AIRPAK and STAR-CD. The effectiveness of the several improvement options were tested, then the best cost effective option was selected. Finally, the standard ventilation systems were proposed to minimize the exposure levels of DMF.

대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구 (Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites)

  • 이창우;웅웬반득
    • 터널과지하공간
    • /
    • 제24권6호
    • /
    • pp.464-472
    • /
    • 2014
  • 환기제어 시설을 설치하지 않고 모든 공간을 개방한 형태의 대단면 주방식 채굴 작업장에 설치하는 국부선풍기의 운전에 따른 기류유동형태는 재순환을 포함하고 있어 복잡하고 정량화가 어렵고 환기효율 또한 매우 낮은 편이다. 본 논문에서는 국부선풍기의 운전에 따라 하류편의 기류 운동에너지 증가 및 정압강하 현상인 벤츄리(venturi) 효과로 인접갱도로부터 기류가 유입되어 기류 유동방향으로 환기량이 증가하는 현상을 선풍기 종류 및 설치방법 별로 CFD분석하였다. 분석대상 선풍기는 축류선풍기 1종류 및 프로펠러 선풍기 2종류이며 축류선풍기 중심점 설치 위치를 1.0, 1.5, 2.0m로 변경함에 따른 벤츄리 효과의 차이를 분석하였다. 연구결과는 공기질 개선을 통한 작업환경 관리를 위한 국부 환기의 경제성 및 효율성을 제고하는데 기여할 것으로 기대된다.

공동주택 화장실의 기계 환기시스템에 관한 연구 (A Study on the Mechanical Ventilation System of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

주거환기용 시로코홴의 내부모터 형상에 따른 공력특성 연구 (A STUDY ON AERODYNAMIC CHARACTERISTICS DEPENDING ON SHAPE OF AN INTERNAL MOTOR IN A SIROCCO FAN FOR RESIDENTIAL VENTILATION)

  • 차경훈;김진혁;김광용
    • 한국전산유체공학회지
    • /
    • 제16권4호
    • /
    • pp.1-6
    • /
    • 2011
  • Aerodynamic characteristics depending on the shape of an internal motor in a small-size sirocco fan for residential ventilation have been investigated. For the aerodynamic analyses of the sirocco fan, three-dimensional Reynolds-averaged Navier-Stokes equations are solved with the shear stress transport model for turbulence closure. The flow analyses are performed on hexahedral grids using a finite-volume solver. The validation of the numerical results at steady-state is performed by comparing with experimental data for the pressure and efficiency. In order to investigate the aerodynamic characteristics depending on shape of an internal motor in a sirocco fan, the reference shape is analyzed compared to the case without internal motor. Additionally, two shape parameters, height and width of the internal motor in a sirocco fan, are tested to investigate their effects on the aerodynamic characteristics. The results show that the shape of the internal motor in a sirocco fan is an important factor to improve the aerodynamic performances.

주거환기용 시로코홴의 내부모터 형상에 따른 공력특성 연구 (A STUDY ON AERODYNAMIC CHARACTERISTICS DEPENDING ON SHAPE OF AN INTERNAL MOTOR IN A SIROCCO FAN FOR RESIDENTIAL VENTILATION)

  • 차경훈;김진혁;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.321-326
    • /
    • 2011
  • Aerodynamic characteristics depending on the shape of an internal motor in a small-size sirocco fan for residential ventilation have been investigated For the aerodynamic analyses of the sirocco fan, three-dimensional Reynolds-averaged Navier-Stokes equations are solved with the shear stress transport model for turbulence closure. The flaw analyses are performed on hexahedral grids using a finite-volume solver. The validation of the numerical results at steady-state is performed by comparing with experimental data for the pressure and efficiency. In order to investigate the aerodynamic characteristics depending on shape of an internal motor in a sirocco fan, the reference shape is analyzed compared to the case without internal motor. Additionally, two shape parameters, height and width of the internal motor in a sirocco fan, are tested to investigate their effects on the aerodynamic characteristics. The results show that the shape of the internal motor in a sirocco fan is an important factor to improve the aerodynamic performances.

  • PDF

초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석 (A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types)

  • 노광철;이승철;오명도
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

고준위 방사성 폐기물 처분장 설계를 위한 Diagonal 환기 회로 내 공기량 분배에 관한 연구 (A Study on the Airflow Distribution in the Diagonal Ventilation Circuit for the Design of a High Level Radioactive Waste Repository)

  • 황인필;최희주;노장훈;김진
    • 터널과지하공간
    • /
    • 제22권3호
    • /
    • pp.173-180
    • /
    • 2012
  • 본 연구에서는 방사성 폐기물 처분장 설계 시 필요할 수 있는 공기 유동 방향의 제어에 이점을 가진 Diagonal 환기 회로에 대해서 연구하였다. 연구 결과, Diagonal 환기 회로에서도 Diagonal 갱도(Branch)로 유입시킬 공기량과 공기 유동 방향을 미리 정한다면 다른 직 병렬 회로와 마찬가지로 수식이나 프로그램에 의한 공기량을 산정할 수 있음을 알 수 있었다. 이를 적용하기 위해 앞으로 처분될 고준위 방사성 폐기물의 추정 데이터를 통해 Diagonal 환기 회로와 병렬식 환기 회로가 적용된 고준위 방사성 폐기물 처분장의 설계안을 마련하였다. 마련된 설계안 별 비교 및 예상 운영 결과를 얻기 위해서 환기 네트워킹 프로그램인 Ventsim 프로그램을 통해 환기 네트워크 시뮬레이션을 수행하였다. 그 결과 저항 증가가 큰 수치로 발생할 것으로 예상되었던 Diagonal 처분장은 병렬식 환기 회로가 적용된 처분장과 비교하였을 때, 팬 압력은 1570 pa, 총 유량 84 $m^3/s$, 팬 효율 76.4%, 팬 소요 전력 181.2 kW 및 연간 팬 운영 비용 178,710,838원으로 압력과 유량값에서 최대 8% 정도의 차이를 보였고, 운영 비용 측면에서는 1.5%의 차이를 보였다.