• Title/Summary/Keyword: Vent system

Search Result 206, Processing Time 0.022 seconds

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

Application of Spring Vent System for the Manufacturing of Solid Tire (솔리드 타이어 제조를 위한 스프링 벤트 시스템의 적용)

  • Son, Jong Nam;Jeong, Young Cheol;Cho, Young Tae;Jung, Yoon Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.8
    • /
    • pp.659-663
    • /
    • 2014
  • Manufacturing processes of industrial tire are composed of mixing, extrusion, curing, trimming and inspecting. Among them curing is the most important process in the production of industrial tire. In this study the newly developed spring vent system was designed in order to solve rubber intrusion problem inside spring vent system in the curing process. After the experiment it is concluded that rubber intrusion was caused by angled stem head part. New spring vent system was manufactured and new design of spring vent system is proper to use for industrial tire curing process.

A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation (박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Rhee, Han-Cheol;Cheong, Jae-Woan;Choi, Gyeong Lee
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

Design of ventilated disc for Improvement using reverse engineering (역설계를 이용한 상용 벤틸레이티드 디스크의 성능향상을 위한 설계)

  • Park I.B.;Lee S.D.;Kwon T.W.;Lee S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.383-384
    • /
    • 2006
  • Ventilated disc was improved for reducing judder and heat. But the crack among vent holes occurs due to stress concentration. We investigate the stress distribution of vent holes. The vent holes with shape of a right angle, a chamfer and rounding was analyzed. The result of FEA was that rounded vent holes have a minimum stress. Also Maximum stress distributed within holes. Therefore We suggest that the rounded vent holes is good to reduce the crack.

  • PDF

Optimal design of escape vent for the dome type coonstrip shrimp (Pandalus hypsinotus) pot (반구형 도화새우통발에 있어서 적정 탈출구의 설계)

  • Kim, Seong-Hun;Lee, Ju-Hee;Kim, Hyung-Seok;Park, Seong-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.2
    • /
    • pp.115-125
    • /
    • 2010
  • In order to design the optimal escape vent for the coon strip shrimp pot, the tank experiments were conducted with the model pot of five different slit height and slit width, respectively. The optimal height and width of escape vent were determined to 20mm and 40mm by tank experiments, respectively. These were determined by the 50% selection carapace length which was denoted to 25mm in selectivity curve. The escape experiments were conducted to determine a number of escape vent with the original shrimp pot to be set the designed escape vent from 2 vents to 10 vents increasing at intervals of 2 vents in tank. The optimal number of escape vents denoted 8 vents. Therefore, to apply the escape vent in commercial shrimp pot will be efficient to reduce small size shrimps to catch.

Dynamic PIV analysis of High-Speed Flow from Vent Holes of Fill-Hose in Curtain type Airbag (Dynamic PIV 기법을 이용한 커튼에어백 Vent Hole 고속유동 해석)

  • Jang, Young-Gil;Choi, Yong-Seok;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.17-20
    • /
    • 2006
  • Passenger safety is fundamental factor in automobile. Among much equipment for passenger safety, the air bag system is the most fundamental and effective device. Beside of the front air bag system which installed on most of all automobiles, a curtain-type air bag is increasingly adapted in deluxe cars fur protecting passengers from the danger of side clash. Curtain type airbag system consists of inflator housing, fill hose, curtain airbag. Inflator housing is a main part of the curtain-type air bag system for supplying high-pressure gases to deploy the air bag-curtain. Fill hose is a passageway to carry the gases from inflator housing to each part of curtain airbag. Therefore, it is very important to design the vent holes of fill hose for good performance of airbag deployment. But, the flow information from vent holes of fill hose is very limited. In this study, we measured instantaneous velocity fields of a high-speed flow ejecting from the vent holes of fill hose using a dynamic PIV system. From the velocity Held data measured at a high frame-rate, we evaluated the variation of the mass flow rate with time. From the instantaneous velocity fields of flow ejecting from the vent holes in the initial stage, we can see a flow pattern of wavy motion and fluctuation. The flow ejecting from the vent holes was found to have very high velocity fluctuations and the maximum velocity was about 480m/s at 4-vent hole region. From the mass flow rate with time, the accumulated flow of 4-vent hole has occupied about 70% of total flow rate.

  • PDF

The Evaluation of Thermal Performance of Double Vent Window System (Double Vent 창호 시스템의 단열성능평가)

  • Ryu, Seung-Ho;Park, Jin-Woo;Moon, Hyeun-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.557-560
    • /
    • 2008
  • Window system is an essential component for ventilation, lighting, and thermal environment in buildings. However, window system has the lowest insulation performance and may cause high energy consumptions, if it is not properly designed. Thus, performance of window systems play an important role in built environment. This study proposes a new window systems for balcony, which has double vents and analyses the thermal performance using an intergrated simulation method with Therm 6.1 and Widow 6.1. The result shows higher U-factor than conventional window systems. It is expected that the double vent window system can increase thermal performance and save energy in apartment houses.

  • PDF

A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX (CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

Design and Development of Vent Relief Valve for Oxidizer Tank (산화제 탱크용 벤트릴리프밸브 설계 및 개발)

  • Koh, Hyeon-Seok;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.854-856
    • /
    • 2011
  • A vent relief valve for oxidizer tank has been designed for liquid propellant feeding system of the space launch vehicle. The vent relief valve ensures oxidizer tank ventilation during filling and its protection from overpressure after filling. Tank ventilation during filling is ensured by vent valve and tank protection is ensured by combined operation of relief valve and vent valve. Numerical analysis predicted that pneumatic behavior and dynamic characteristics met the valve requirements. After manufacturing the prototype model, we have been conducting the tests to evaluate the performance of the vent relief valve.

  • PDF

Development of roll - up ventilation system for pipe- constructed plastic film greenhouse (파이프 비닐온실용 권취식 창개폐기의 개발)

  • 이기명;박규식;김유일;김태홍
    • Journal of Bio-Environment Control
    • /
    • v.4 no.2
    • /
    • pp.232-239
    • /
    • 1995
  • This study was carried out to get required torque data needed to design and develop a roll-up ventilation system in a pipe-constructed plastic film green-house. The results obtained from this study are as follows : 1. The required torques of a roll-up ventilation system in greenhouse are the functions of its length. The torques should multiplied by the conversion coefficients (2.0 in ceiling vent, 1.8 in side vent) in case of application. 2. In constructing pipe-constructed plastic film greenhouse, a shaft pipe is the largest essential element in roll - up shaft weight constitution which have an effect on the required torques. Therefore, the pipe should be light using nonferrous materials like aluminum alloy. 3. A planetary reduction ventilator of differential ring gear type is suitable for a roll-up ventilation system, because it can make high efficient reduction just using the first step shift.

  • PDF