• Title/Summary/Keyword: Vent Port

Search Result 13, Processing Time 0.022 seconds

Numerical Study on the Effect of Area Changes in Air Inlets and Vent Ports on the Ventilation of Leaking Hydrogen (급·배기구 면적 변화가 누출 수소 환기에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.385-393
    • /
    • 2022
  • Hydrogen has reduced greenhouse gas (GHG) emissions, the main cause of global warming, and is emerging as an eco-friendly energy source for ships. Hydrogen is a substance with a lower flammability limit (LFL) of 4 to 75% and a high risk of explosion. To be used for ships, it must be sufficiently safe against leaks. In this study, we analyzed the effect of changes in the area of the air inlet / vent port on the ventilation performance when hydrogen leaks occur in the hydrogen tank storage room. The area of the air inlet / vent port is 1A = 740 mm × 740 mm, and the size and position can be easily changed on the surface of the storage chamber. Using ANSYS CFX ver 18.1, which is a CFD commercial software, the area of the air inlet / vent port was changed to 1A, 2A, 3A, and 5A, and the hydrogen mole fraction in the storage chamber when the area changed was analyzed. Consequently, the increase in the area of the air inlet port further reduced the concentration of the leaked hydrogen as compared with that of the vent port, and improved the ventilation performance of at least 2A or more from the single air inlet port. As the area of the air inlet port increased, hydrogen was uniformly stratified at the upper part of the storage chamber, but was out of the LFL range. However, simply increasing the area of the vent port inadequately affected the ventilation performance.

A Study on the Shock Wave Caused by VCE in Enclosure (밀폐공간에서의 VCE에 의한 충격파 고찰)

  • Leem, Sa-Hwan;Lee, Jong-Rark;Huh, Yong-Jeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • In order to establish detailed plans for fire protection and reduce the possible fire accidents in the future, a study on the shock wave caused by VCE(Vapor Cloud Explosion) is very important. Destruction phenomena of structure by gas explosion is due to the explosion pressure and heat. Explosion pressure is a kind of energy converted from the gas mixture explosion. Therefore, the propagation progress of shock wave and flame is very important. This study investigated the shock wave caused by VCE in enclosure with opened vent port. From a result, the vent port of top at the straight line of ignition and leak location was opened most rapidly, and the vertical vent port not opened.

A Study on the Shock Wave caused by VCE in Enclosure (밀폐공간에서의 VCE에 의한 충격파 고찰)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Lee, Jong-Rark
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.54-59
    • /
    • 2007
  • In order to establish detailed plans for fire protection and reduce the possible fire accidents in the future, a study on the shock wave caused by VCE(Vapor Cloud Explosion) is very important. Destruction phenomena of structure by gas explosion is due to the explosion pressure and heat. Explosion pressure is a kind of energy converted from the gas mixture explosion. Therefore, the propagation progress of shock wave and flame is very important. This study investigated the shock wave caused by VCE in enclosure with opened vent port. From a result, the vent port of top at the straight line of ignition and leak location was opened most rapidly, and the vertical vent port not opened.

  • PDF

Development of a Vent Analysis Method for Multiple Compartments Connected Through Multiple Ports (다중 Port로 연결된 다중 격실 Vent 해석 기법 개발)

  • Ok, Ho-Nam;Kim, In-Sun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.547-550
    • /
    • 2006
  • An analysis method is developed for the prediction of venting in multiple compartments which are connected in series or parallel through multiple ports. The existing method by the authors is modified to remove the limitation in number of ports and compartments, and the more general polytropic relation or solution of the additional energy equation replaces the previous isentropic relation allowing the prediction of pressure rise in addition to pressure drop. The accuracy of the method is verified by comparison with the results by NASA Flap code for the problem of pressure drop in a payload in the Space Shuttle cargo bay. It is expected that this method will be a useful tool in prediction of the pressure variation in a payload or payload capsule without mentioning the payload fairing itself.

  • PDF

PREDICTION OF THE ORIFICE DISCHARGE COEFFICIENT USING COMPUTATIONAL FLUIDS DYNAMICS (전산유동해석을 이용한 ORIFICE 방출 계수 예측)

  • Ok, H.;Kim, I.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.147-150
    • /
    • 2006
  • Vent ports are installed on the walls of closed compartments of a launch vehicle to control the pressure drop in the compartments. The ports can be modelled as an orifice, and the accurate prediction of the discharge coefficient of an orifice is essential for the design of vent ports. Experimental methods have been used to determine the discharge coefficients for various shapes of orifices, and extensive databases are available. Wind tunnel tests have been also done to evaluate the effect of interaction between venting outflow and freestream for limited conditions. The goal of the present research is to predict the discharge coefficient of an orifice using CFD and evaluate the accuracy of the method, especially for the orifices exposed to the external flow.

  • PDF

Experimental Study on Ventilation Efficiency of Leakage Gas Based on Supply and Exhaust Vent Location (밀폐공간에서 급·배기구 위치에 따른 누출 가스의 환기효과에 관한 실험적 연구)

  • Ha-Young Kim;Seong-Min Lee;Byeol Kim;Kwang-Il Hwang
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.274-283
    • /
    • 2024
  • Climate change is currently one of the most pressing environmental issues, primarily caused by carbon emissions from fossil fuel usage. As a result, alternative fuels that effectively reduce carbon emissions are garnering more attention. Among these alternatives, hydrogen has numerous advantages, such as its ability for large-scale storage and transport. However, it is crucial to prioritize safety measures, particularly in facilities that handle hydrogen, due to its highly flammable and fast-spreading nature. This study aims to compare and analyze the placement of supply and exhaust vents to efficiently release hydrogen in the event of a leak in an enclosed space. The experiments involved six different scenarios, each with various combinations of supply and exhaust vents. To ensure the experimental process's safety, helium, which shares similar physical properties with hydrogen, was used to analyze the internal oxygen concentration during ventilation system operations. The results revealed that among the six scenarios, Case 2, which employed a lower side supply vent and an upper side exhaust vent, exhibited the shortest ventilation time of 4 minutes and 30 seconds. Additionally, the decrease rate in oxygen concentration was examined in the upper, middle, and lower areas. Ventilation utilizing an upper surface supply vent and two exhaust vents on the upper surface and upper side (Case 6), showed lower oxygen concentration values in the upper area, while Case 2 yielded lower values in the middle and lower areas. Therefore, it is crucial to select an appropriate supply and exhaust vent configuration considering the space's characteristics and usage environment.

A Design on the Discharge Vent for Gas Experimental Booth (가스 폭발 Booth의 방출구 설계)

  • Huh, Yong-Jeong;Ma, Sung-Jun;Jeong, Pil-Young;Leem, Sa-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.362-366
    • /
    • 2007
  • As the industry of 21C has been developed, the gas industry has been grown and its convenience but it accompany risk for using gas. Therefore, we designed a vent area to prevent the collapse of the booth by the explosion pressure during test. The explosion booth was installed fur training safety supervisors to aware the risk of gas explosion. The vent area was designed based on the exhaust model of NFPA 68. It was calculated at $2.8297m^2$ for LPG and at $3.0518m^2$ for NG.

  • PDF

Acoustic and Electrical Analysis of Microspeaker for Mobile Phones (모바일 폰용 마이크로스피커의 음향 및 전기 해석)

  • Park, Seok-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.525-536
    • /
    • 2014
  • In this paper, GUI program for microspeaker system simulation program was developed and verified through closed box, vent box and 6th order bandpass enclosure system. By using the pseudo loudspeaker model concept, TS parameters and rear volume of microspeaker were identified. Their suitabilities were proved by comparing test results with simulations of electrical impedance and sound pressure response curves for the three box types; closed box, vent box and 6th order bandpass box. Also, MSSP was found to be effective regardless of the microspeaker's shape, either circular or rectangular shape. MSSP can be used for the microspeaker system simulation, and can give a general prediction of such as; sound pressure level curve, electrical impedance, diaphragm velocity and displacement curve according to multiple design parameters; diaphragm mass, compliance, force factor, front and rear volume, front and rear port's diameter and length.

A Study on Optimum Pressure Vent of Experimental Booth by Gas Explosion

  • Leem, Sa-Hwan;Lee, Jong-Rark;Huh, Yong-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.59-63
    • /
    • 2007
  • The purpose of this paper is to find optimum vent port of the booth for gas explosion experiment. Also, it is to understand the safety of the booth for explosion experiment which is installed to let the trainees for legal education which is managed by IGTT(Institute of gas technology training) blow the riskiness of explosion. Since the booth for gas explosion experiment is a confined space, we used the exhaust model for indoor explosion. As the result, it was safety calculated when the amount of leaking gas was close to the maximum of explosion limit on the explosion experiment.

  • PDF

A study of the shape and tailoring of frock coats in the Korean Empire - Park Ki-Jong's frock coat - (대한제국기 프록코트의 형태와 제작법에 관한 연구 - 박기종 유물 조사를 중심으로 -)

  • Choi, Eunjoo
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.3
    • /
    • pp.439-453
    • /
    • 2015
  • This research is regarding Park Ki-Jong's Western-style court costume and emphasizes the shape and style peculiarities of Western-style court costumes in the Korean Empire from the 1876 Port Opening to the 1910 annexation of Korean to Japan. Park Ki-Jong's frock coat was made during the period of the established law from 1900 to 1910. 1) The brand was ASADA TAILOR from Kyung-Sung. 2) The shape was long at the front and back, and it featured a picked lapel and double breast with six buttons to fasten and two buttons for decoration on the upper part. 3) The frock coat's materials were black wool fabric and black ridged silk. The lining's material was black plain silk and the sleeve's lining was white with blue striped silk. 4) The front separated the upper and bottom parts. The bottom was composed of a one-piece A-line skirt that continued from the front to back. The top of the back was separated by the princess line and the center-back seam was also separated with a vent. However, the center-back of the waistline was not separated, and it continued to one piece. The sleeve shape was a two-piece sleeve style with a phony vent and two wrapping buttons.