• 제목/요약/키워드: Vent

검색결과 554건 처리시간 0.022초

주조방식에 따른 티타늄 주조체의 내부결함 비교 (Comparison of internal porosity of dental titanium castings with different casting machines)

  • 이경은;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.129-140
    • /
    • 2007
  • The purpose of this study was to evaluate the titanium castability (internal porosity) between pressure type casting machine & centrifugal casting machine with air-vent or not. Internal porosity is a well-known problem in dental titanium casting, resulting in inferior mechanical properties of dental restorations. To evaluate the castability, the square plate was chosen. 40 plate patterns($20{\times}20{\times}1.8mm$)were attached to funnel-shaped sprue. Then 20 plate patterns were attached air-vent. They were invested in titanium investment material and cast in a pressure type casting machine(20castings) and centrifugal casting machine(20castings). Each group were divided with air-vent(10castings) or not(10castings). The titanium castings were evaluated by radiographic photograph for the location of the internal porosities. The percentage porosity of each specimen was determined using standardized digital radiographs. The results were analyzed with analysis of variance and t-test for paired comparison between two groups.

  • PDF

A Study on Flow Characteristics of Polluted Air in Rectangular Tunnel Models Using a PIV System

  • Koh, Young-Ha;Park, Sang-Kyoo;Yang, Hei-Cheon;Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.825-832
    • /
    • 2010
  • The objective of this study is to investigate flow behaviors of polluted air in order to prevent the impact of disaster in a tunnel. This paper presents the experimental results qualitatively in terms of flow characteristics in two kinds of rectangular tunnel models in which each distance from the centerline above the inlet vent to the exhaust vent is 0 and 60 mm, respectively. The olive oil is used as the tracer particles. The flow is tested at the flow rate of $14.16{\times}10^{-4}\;m^3/s$ and the inlet vent velocity of 1.1 m/s with the kinematic viscosity of air. The aspect ratio of the model test section is 10. The average velocity vectors, streamlines, and vorticity distributions are measured and analyzed by the Flow Manager in a particle image velocimetry(PIV) system. The PIV technology gives three different velocity distributions according to observational points of view for understanding the polluted air flow characteristics. The maximum value of mean velocity generally occurs in the inlet and outlet vent regions in the tunnel models.

수치해석에 의한 고압다이캐스팅용 금형설계 및 주조공정해석 (Analysis of the High Pressure Die Casting Process by Computer Simulation)

  • 이창호;최재권;남태운
    • 한국주조공학회지
    • /
    • 제20권6호
    • /
    • pp.400-406
    • /
    • 2000
  • Computer simulation for the predictions of casting defects is very important to produce high quality castings with less cost. Complicate shaped Al solenoid housing part was selected to be cold chamber die cast and a numerical simulation technique was applied for the optimization of the chill vent position and gating. A first design led to insufficient central flow. This flow left the last filled areas falling into the inner portion of the part. And last filled area did not fit the chill vent position. So these resulted in a high possibility of air entrapment in the casting and the design was not proper for the part. The design was improved by using a proper gating system, a more chill vent and proper overflow positions. New design provided a homogenous mold filling pattern and the last filled areas that being located at the overflow and chill vent. Casting plan which produce good quality solenoid housing part was established by using the computer simulation.

  • PDF

인체모델을 고려한 자동차 실내의 에어컨 토출구 위치 변화에 따른 냉방성능 및 온열쾌적성 평가 (Evaluation of Thermal Comfort and Cooldown Performance inside Automotive Cabin according to Air-conditioning Vent Location)

  • 서진원;박재홍;최윤호
    • 한국자동차공학회논문집
    • /
    • 제20권5호
    • /
    • pp.120-129
    • /
    • 2012
  • As the recent advancement of automobile industry, there has been a great interest in the thermal comfort of the passengers inside the cabin of an automobile. Thermal comfort is affected by temperature, velocities, and mean radiation temperature of air, thermal resistance of clothes and physical active level of human. The present study performed computational analysis to select the location of air-conditioning vent that improves thermal comfort inside the cabin. In order to do this, we considered various air vent positions, and thermal flow analysis of each case is performed using CFD for the cabin with four passengers. The thermal comfort is evaluated using the computational results and the optimum location of air vent is suggested.

전산모사에 의한 웨이브 히트싱크의 열유동 특성 해석 (Heat Flow Analysis in the Newly Developed Wave Heat Sink by Computational Simulation)

  • 이인규;이상웅;강계명;장시영
    • 한국재료학회지
    • /
    • 제14권12호
    • /
    • pp.870-875
    • /
    • 2004
  • Heat flow characteristics in the newly developed Wave Heat Sink were analyzed under natural and forced convections by Icepak program using the finite volume method. Temperature distribution and thermal resistance of Wave Heat Sink with/without air vent hole on the top of fin were compared with those of a commercial Al extruded heat sink(Intel Heat Sink). Under the natural convection, the maximum temperature was $45.1^{\circ}C$ in the air vent hole typed Wave Heat Sink, which was superior to that of Intel Heat Sink. The thermal resistance was $2.51^{\circ}C/W$ in the air vent hole typed Wave Heat Sink, and it changed to $2.65^{\circ}C/W\;and\;2.16^{\circ}C/W$ with changes of gravity direction and fin height, respectively. Under the forced convection, the maximum temperature became lower than that under the natural convection. In addition, the thermal resistance lowered in the air vent hole typed Wave Heat Sink with higher fin height and it decreased with increasing the air flux.

신발금형의 가스 배출량 측정 장치와 영상정보를 이용한 가스벤트 자동 교환 시스템의 개발 (A study on the development of gas measurement system in shoes mold and automatic gas-vent exchange machine with computer vision)

  • 권장우;홍준의;윤동업;최흥호;길경석
    • 센서학회지
    • /
    • 제15권1호
    • /
    • pp.20-27
    • /
    • 2006
  • This paper presents a gas measurement system for deciding hole positions on a PU middle-sole mold from computed gas amount. The optimal number of holes and their positions on the shoe mold are decided from statistical experiment results to overcome the problem of excessive expenses in gas vent exchange. This paper also describes a gas vent exchange mechanism using computer vision system. The gas hole detecting process is based on computer vision algorithms represented as a simple Pattern Matching. The experimental result showed us that the system was useful to calculate the number of holes and their positions on the shoes mold.

Vent의 형성이 도재전장 비귀금속합금 주조체의 변연부 적합도에 미치는 영향 (The effect of vent on the marginal discrepancy of the PFM base metal castings)

  • 김태석;이성욱;오세윤;김웅철;김지환;유진호
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.45-53
    • /
    • 2001
  • This study was performed to investigate the effect of vent on the marginal discrepancy of PFM base metal castings. Eighteen identical wax patterns of a maxillary 3 unit anterior bridge were fabricated. Nine cases out of them were vented with $\phi$2.5mm sprue wax, for direct comparison as to the marginal discrepancy of the castings with the other non vented 9 ones. The mean value of marginal discrepancies of the vented castings was $85.02{\pm}25.57{\mu}m$, and that of the non vented was $163.21{\pm}69.88{\mu}m$ respectively. Statistical analysis revealed that marginal discrepancy of the vented casting was significantly reduced(p<0.05).

  • PDF

카본 세라믹 복합재 디스크의 벤트 구조 최적화를 통한 냉각성능 향상에 관한 연구 (A Study on Improvement of Cooling Performance through Vent Structure Optimization of Carbon Ceramic Composite Disc)

  • 심재훈;신웅희;이중희;전갑배;김병철;곽정후;임동원;현은재;전태형;이재만
    • 자동차안전학회지
    • /
    • 제11권1호
    • /
    • pp.23-29
    • /
    • 2019
  • Recently, use of composite materials has been increasing for body structures and chassis parts in the car industry because of weight reduction effect and excellent mechanical thermal characteristics. However, application of composite materials in brake system is very difficult because it is hard to obtain enough brake performance due to low heat storage capacity of the composite materials. In this paper, we will present new carbon ceramic composite disc with high flow characteristic. To obtain this characteristic, new vent structures were designed by using ARIZ method and substance-field model analysis. The flow effect of these vent structures on the brake performance was verified by pugh matrix and cooling test. The test results show improvement of cooling performance up to $30^{\circ}C$. Finally, These results will improve brake the reliability of the brake performance for the high performance vehicles and electric vehicles.

맨홀과 연결된 지하 열수송설비의 부식 원인 및 재질 내식성 평가 (Cause of Corrosion and Evaluation of Material Corrosion Resistance on Underground Heat Transport Facilities Connected to Manhole)

  • 송민지;최가현;김우철;이수열
    • 열처리공학회지
    • /
    • 제35권4호
    • /
    • pp.193-202
    • /
    • 2022
  • Manholes and underground spaces are installed to manage the buried heat transport pipes of the district heating system, and the corrosion damage of the equipment placed in this space often occurs. The purpose of this work is to identify locations with a high risk of corrosion damage in the air vent and to establish preventive measures based on precise analysis via sampling of heat transport pipes and air vents that have been used for about 30 years. The residual thickness of the air vent decreased significantly by reaching ~1.1 mm in thickness, and locations of 60~70 mm away from a transport pipe were the most vulnerable to corrosion. The energy dispersive X-ray spectroscopy (EDS) analysis was performed in the corroded oxides, and it was found that chloride ion was contained in the corrosion products. Anodic polarization tests were carried out on the air vent materials (SPPS250, SS304) with varying the amounts of chloride ions at two different temperatures (RT, 80℃). The higher concentration of chloride ions and temperature are, the lower corrosion resistances of both alloys are.

열수송관에 연결된 에어벤트에 적용 가능한 부식 방지 방안 (Corrosion Protective Method Applicable to Air Vent Connected with a Heat Transport Pipe)

  • 송민지;최가현;김우철;이수열
    • Corrosion Science and Technology
    • /
    • 제22권2호
    • /
    • pp.115-122
    • /
    • 2023
  • This study aimed to elucidate causes of corrosion of heat transport pipes and air vents installed under a manhole of heat transport facilities and suggest effective anticorrosive measures by applying paints or adhesive tapes. It was found that air vent corrosion was attributed to corrosion under insulation caused by the inflow of water and the enrichment of chloride ions. The infiltrated water caused a hydrolysis of polyurethane foam (PUF) insulation by concentrating chloride ions at the interface between a pipe and the PUF. As insulator deteriorated, more chloride ions were eluted as confirmed by ion chromatograph (IC) analysis. As an effective method to prevent air vent corrosion, different types of paints and adhesive tapes with higher corrosion resistance on chloride ions were applied and environmental resistance tests were performed with those samples. Based on environmental test results of samples exposed to 10% HCl solution, it was revealed that a wax tape was the most adequate from a viewpoint of stability at operating condition, environmental resistance, surface treatment, and field applicability.