Analysis of the Vent Path Through the Pressurizer Manway Under the Loss of Residual Heat Removal(RHR) System During Mid-Loop Operation in PWR (가압경수로 부분충수 운전중 잔열제거 (RHR)계통 상실시 가압기 통로를 통한 배출유로 특성 분석)

  • Ha, G.S.;Kim, W.S.;Chang, W.P.;Yoo, K.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.859-869
    • /
    • 1995
  • The present study is to understand the physical phenomena anticipated during the accident with RHR loss under mid-loop operation in a PWR and, at the same time, to examine the prediction capability of RELAP5/MOD3.1 on such an accident, by simulating an integral test relevant to this accident for reliable analysis in an actual PWR. The selected experiment, i.g. BETHSY Test 6.9a, represents the configuration with the pressurizer manway open and steam generators unavailable during the accident. Accordingly, the results of this ok are sure to contribute to understanding both the key events as well as the sensitive parameters, anticipated in the accident, for validity of the actual analysis. In the simulation result overall behavior as well as major phenomena observed in the experiment have been predicted reasonably by RELAP5/MOD3.1, however, the problem associated with enormous computing time .due to small time step size has been encountered. Besides, the code prediction of higher swollen level in the pressure vessel has given rise to overestimation of both pressurizer level and RCS pressure. Subsequently, overprediction of the break flow through the manway has led to earlier core uncovery than that in the experiment by about 400 seconds. As a whole, it is demonstrated from both the experiment and the analysis that gravity feed has not been sufficient to recover the core level and thus additional forced feed has been necessary in this configuration.

  • PDF

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Banded Iron Formations in Congo: A Review

  • Yarse Brodivier Mavoungou;Anthony Temidayo Bolarinwa;Noel Watha-Ndoudy;Georges Muhindo Kasay
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.745-764
    • /
    • 2023
  • In the Republic of Congo, Banded iron formations (BIFs) occur in two areas: the Chaillu Massif and the Ivindo Basement Complex, which are segments of the Archean Congo craton outcropping in the northwestern and southwestern parts of the country. They show interesting potential with significant mineral resources reaching 2 Bt and grades up to 60% Fe. BIFs consist mostly of oxide-rich facies (hematite/magnetite), but carbonate-rich facies are also highlighted. They are found across the country within the similar geological sequences composed of amphibolites, gneisses and greenschists. The Post-Archean Australian Shale (PAAS)-normalized patterns of BIFs show enrichment in elements such as SiO2, Fe2O3, CaO, P2O5, Cr, Cu, Zn, Nb, Hf, U and depletion in TiO2, Al2O3, MgO, Na2O, K2O, Sc, Th, Ba, Zr, Rb, Ni, V. REE diagrams show slight light REEs (rare earth elements; LREEs) compared to heavy REEs (HREEs), and positive La and Eu anomalies. The lithological associations, as well as the very high (Eu/Eu*)SN ratios> 1.8 shown by the BIFs, suggest that they are related to Algoma-type BIFs. The positive correlations between Zr and TiO2, Al2O3, Hf suggest that the contamination comes mainly from felsic rocks, while the absence of correlations between MgO and Cr, Ni argues for negligeable contributions from mafic sources. Pr/Pr* vs. Ce/Ce* diagram indicates that the Congolese BIFs were formed in basins with redox heterogeneity, which varies from suboxic to anoxic and from oxic to anoxic conditions. They were formed through hydrothermal vents in the seawater, with relatively low proportions of detrital inputs derived from igneous sources through continental weathering. Some Congolese BIFs show high contents in Cr, Ni and Cu, which suggest that iron (Fe) and silicon (Si) have been leached through hydrothermal processes associated with submarine volcanism. We discussed their tectonic setting and depositional environment and proposed that they were deposited in extensional back-arc basins, which also recorded hydrothermal vent fluids.

Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.

Monitoring the Alternative Habitat of Kaloula Borealis and Analysis on Meteorological Factors in Pyeongtaek (평택지역의 맹꽁이 대체서식지 모니터링 및 기상요인 분석)

  • Min-Ho Choi;Yang-Seop Bae
    • Journal of Life Science
    • /
    • v.34 no.4
    • /
    • pp.264-270
    • /
    • 2024
  • This study is conducted to analyze environmental factors that affect the ecology of boreal digging frog and use them as basic data for selecting (or creating) suitability of alternative habitats for survival and monitoring method from 2020 to 2022 after boreal digging frog were relocated to the alternative habitats in 2019. Analyzing the environment of the alternative habitats showed that the criteria suited the followings: distance from wetlands, grasslands and rivers was within 5 m, the low-rise grassland was 6,000 m2, soft soil was at a depth of ≥20 cm, and the area of permanent wetlands was 5,000 m2 wide. As a result of the correlation analysis between meteorological factors and population (n) and breeding, there was a significant correlation between rainfalls and breeding (p<0.01). During the monitoring, it was confirmed that the SVL (Snout-Vent Length) and BM (Body Mass) of the translocated population were maintained (p>0.05), and it was found that the proximity of the habitat and spawning pond, securing food space (grasslands), soil quality, and wetlands could function as an alternative habitat if conditions were met. As a result of analyzing the meteorological factors affecting the population of boreal digging frog, the SVL had a statistical impact on the minimum temperature, maximum temperature, relative humidity, and the rainfall (p<0.05). In the case of breeding, rainfall was found to be affected (p<0.01), and the population was statistically affected by the average temperature, minimum temperature, and relative humidity (p<0.05).

Study on size diversity according to the sex, period, and habitat of three new Korean Hynobius salamanders: Hynobius geojeensis, H. perplicatus, and H. unisacculus (한국산 도롱뇽 3종 거제도롱뇽, 숨은의령도롱뇽, 꼬마도롱뇽의 성별, 시기 그리고 서식지에 따른 크기 다양성 연구)

  • Yu-Jeong Jeong;Yikweon Jang;Kyo Soung Koo
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.4
    • /
    • pp.557-569
    • /
    • 2023
  • Amphibians are the world's most threatened group of animals, with approximately 41% facing extinction. Contrary to this global trend, the number of amphibian species in Korea has increased by approximately 53.3% over the past 20 years. In particular, salamanders within the genus Hynobius showed even greater diversity, with the number increasing three-fold from two species to seven. However, morphological and ecological traits required for the clear differentiation of these animals are yet to be determined, leading to much confusion. In this study, we investigated the validity of using size traits for species identification, as this method is currently considered a rule of thumb when differentiating Geoje salamanders (Hynobius geojeensis), cryptic Uiryeong salamanders (H. perplicatus), and Korean small salamanders (H. unisacculus). Our study revealed that sex, study period, and habitat were all factors associated with significant differences in snout-vent length, head width, and body weight. Differences in these size traits were evident both between and within species. Our results show that body size traits applied in the recent classification of the three new salamander species could not be seen as a suitable criterion. Such identification methods based solely on body size not only cause great confusion in the field but will also limit future research on Korean Hynobius salamanders.

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Petrological Characteristics and Origin of Volcaniclasts within the Massive Tuff Breccia Formation from Dokdo Island, Korea (독도 괴상 응회질 각력암층에서 나타나는 화산암편의 암석학적 특성과 기원)

  • Shim, Sung-Ho;Im, Ji-Hyeon;Jang, Yun-Deuk;Choo, Chang-Oh;Park, Byeong-Jun;Kim, Jung-Hun
    • The Journal of the Petrological Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.141-156
    • /
    • 2010
  • Dokdo Island, Korea, is located in the East Sea belonging to back arc basin. In this study we examined petrology and geochemistry of massive tuffaceous breccia (MTB) from Dongdo (Eastern islet) and Seodo(Western islet), the two largest islands of Dokdo. Field studies and chemical analysis distinguish the MTB in Dongdo and Seodo. The Dongdo MTB (DMTB) is exposed up to 50 m on the ocean cliff and it has dominant basalt and trachybasalt with moderate amount of trachyte and scoria. On the other hand, Seodo MTB (SMTB), which is preserved between trachyte dike and trachyandesite, is composed of roughly equal amounts of basalt, trachybasalt and trachyte. The location of the islets were related to the source vent having in contact with underlying trachyte lava and differential pyroclastic deposits made them different characteristics. According to trace element analysis of trachytic volcanic clasts, the Ba concentration ranges from 66 to 103 ppm and Sr varies from 44 to 56 ppm in DMTB. However, Br and Sr in SMTB correspondingly showed relatively wide ranges: Br 785-1259 ppm and Sr 466-1230 ppm. These differential trends between DMTB and SMTB, along with the difference in P and Ti, indicate that the crystallization of alkali feldspar, feldspathoid, biotite, apatite and titanium took place differently. Nevertheless, DMTB and SMTB are similar in REE patterns and they are correspondingly characterized by high LREE, low HREE and similar $(La/Yb)_N$ values with 23.9-40.2 in DMTB and 27.4-32.9 in SMTB. These patterns suggest that Dongdo and Seodo might be originated from coeval magma suites. Dokdo island shows high concentrations of Ba, K and Rb. These signatures mark a result attributed to the mantle upwelling because the magma derived from the asthenosphere was metasomatized with subduction-related fluids.

Mineralogical and Fluid Inclusion Study on Seafloor Hydrothermal Vents at TA25 Subsea Caldera in Tongan Waters (통가 TA25 해저산 칼데라 해저열수 분출구의 광석광물 산상 및 유체포유물 연구)

  • Choi, Sun Ki;Lee, Kyeong-Yong;Pak, Sang Joon;Choi, Sang-Hoon;Lee, In-Kyeong
    • Economic and Environmental Geology
    • /
    • v.48 no.4
    • /
    • pp.273-285
    • /
    • 2015
  • The extensive hydrothermal deposits have been found, for the first time, on the western TA25 seamount caldera in the Tonga arc. The seafloor hydrothermal vents are active and immature, emitting the transparent fluids of which temperatures range from $150^{\circ}C$ to $242^{\circ}C$ (average=$203^{\circ}C$). The recovered hydrothermal sulfides are mainly composed of sphalerite, pyrite, marcasite, galena, chalcopyrite, covellite, tennantite, enargite and sulfates such as barite, gypsum/anhydrite. Predominant sphalerite categorize it into Zn-rich hydrothermal ore body. Zn-rich sulfide ores have minor enargite, indicating that mineralization occurred in high sulfidation environment. The proportion and FeS content of sphalerite increase from outside to inside of the hydrothermal ores, respectively. In particular, sphalerite has a great silver content (up to ~10 wt.%). Chalcopyrite is more frequently observed in mound than in the chimney, implying mineralization temperature in the mound is higher than in the chimney. Homogenization temperatures and salinities from fluid inclusions in barite at the mound range from $148^{\circ}C$ to $341^{\circ}C$ (average=$213^{\circ}C$) and 0.4 to 3.6 equiv. wt.% NaCl, respectively. Homogenization temperatures suggest that sulfides in the mound mineralized at a higher temperature (${\geq}200^{\circ}C$) than in the chimney.

Reproduction Cycle and Litter Size of Red-tongued viper snake (Gloydius ussuriensis) (쇠살모사의 생식주기와 한배의 출산수)

  • Kim, Byoung-Soo;Oh, Hong-Shik
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.5
    • /
    • pp.531-541
    • /
    • 2014
  • This research investigated the reproduction cycle, litter size, and the effects of factors of red-tongue viper snake inhabiting in Jeju Island, to delve into their life strategy. Field survey was conducted in Jeju Island from May 2006 to November 2008. Reproduction cycle was analyzed through measurements of testis and follicle sizes in laboratory from March 2009 to December 2010. According to the research results, the sizes of red-tongue viper snake's testis and follicle clearly changed seasonally. The number of eggs within the oviduct were greater on the right side ($2.6{\pm}1.0$ eggs, n=16) than on the left side ($1.8{\pm}0.5$ eggs, n=16) (t=-2,721, p<0.05). Average (${\pm}SD$) of survival litter size (SLS) was $4.4{\pm}1.7$ (1~9, range), while total litter size (TLS) was $4.7{\pm}1.5$ (3~9, range), which were not statistically significant. However, their litter sizes were similar to the number of eggs within the oviduct (t=0.039, P>0.05). Relative litter mass (RCM) was $0.42{\pm}0.13$ (0.18~0.79, n=33), and tended to increase, as maternal condition of pre-parturition (MCPPI) was getting better. The sexual ratio of delivered litters showed no significant difference between male and female red-tongue viper snakes (♂:♀ = 1.15:1, n=73 ; ${\chi}^2$=0.342, P>0.5). Average neonate mass showed a weak correlation with maternal mass of pre-parturition (MMPP1) (r=0.387, P<0.05, n=33). Average neonate Snout-vent length (SVL) also demonstrated a weak correlations with maternal SVL (r=0.399, P<0.05, n=33) and MMPP1 (r=0.344, P<0.05, n=33). Average neonate mass and maternal SVL approached significant probability (r=0.323, P=0.067, n=33). This indicates that mother snakes can bear bigger litter due to its larger size. In some cases, litter's weight decreases as mother snakes are bearing more litter; however, the red-tongued viper snake did not show such exchange relationship. From this, it can be conjectured that a red-tongued viper snake has peculiarity of its own species. The research results are predicted to be used as the basis to find a life history of red-tongued viper snake.