• Title/Summary/Keyword: Veneering material

Search Result 34, Processing Time 0.017 seconds

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

Spectrophotometric analysis of the influence to shade of zirconia core on the color of ceramic (지르코니아 코아의 색조부여가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석)

  • Baek, Ki-Hyun;Woo, Yi-Hyung;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.409-419
    • /
    • 2008
  • Statement of problem: At all times people have tried to fabricate tooth restorations using tooth colored materials. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. The basic color of zirconia is white to ivory. The color can be partially adapted by veneering it with ceramic materials. However, it would be better if the substructure could already be adapted to the basic color shade of neighboring teeth. By adaptation to the basic shade, it can help to reduce the necessary layer thickness of the veneer ceramic to achieve the desired color. Purpose: The purpose of this study was to spectrophotometrically evaluate the influence of shading of zirconia core on the final shade of all-ceramic restorations using the CIE $L^{*}a^{*}b^{*}$ system. Material and methods: Core specimens (n = 20 per group) of Lava Frame Zirconia, KaVo Everest Zirconia, Digident CAD/CAM Zirconia were fabricated at 20 mm in diameter and 0.5 mm in thickness. Halves of each groups were shaded in A3 color. These core specimens were veneered with A3 porcelain of the recommended manufacturer at thickness of 0.5 mm. CIE $L^{*}a^{*}b^{*}$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan) at 0.5 mm, 0.4 mm, 0.3 mm in thickness. Color differences were calculated using the equation ${\Delta}E^{*}=[({\Delta}L^{*})2+({\Delta}a^{*})2+({\Delta}b^{*})2]1/2$. Results: 1. In the case where porcelain layer has a thickness of 0.5 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, however Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 2. When the thickness of porcelain layer decreased from 0.5 mm to 0.4 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, on the other hand Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 3. When the thickness of porcelain layer decreased from 0.5 mm to 0.3 mm, clinically perceived color differences were observed from all three groups. Conclusions: Ziroconia system, which is possible to allow shade on core, are thought to be much more favorable to reproduce natural shade compared to systems that is impossible to give shade. Therefore, clinicians ought to choose adequate system for certain clinical situation by considering above specific character.

Adaptability of zirconia core fabricated by cold isostatic pressing (냉간 정수압 성형법으로 제작된 지르코니아 코어의 적합도에 관한 연구)

  • Seo, Yoon-Jeong;Yun, Kwi-Dug;Kim, Hyun-Seung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.143-150
    • /
    • 2010
  • Purpose: The purpose of this study is to fabricate the new zirconia block (CNU block) and to evaluate fit of core and porcelain veneered zirconia crown. Material and methods: The experimental blocks were fabricated from the commercial ytrria-stabilized zirconia powder (KZ-3YE Type A). The powder was uniaxial pressing and the green bodies were conducted using the Cold Isostatic Pressing. The zirconia blocks were presintered at $1040^{\circ}C$ and the final sintering was performed at $1450^{\circ}C$. The Kavo Everest ZS $blank{(R)}$ (KaVo, Biberach/ $Ri{\beta}$.) was used as a control group. The linear shrinkage of CNU block and Kavo block were compared. Twenty-one cores for porcelain veneered crowns were fabricated with CAD/CAM system ($Everest{(R)}$, Biberach/ $Ri{\beta}$.). Group I; seven cores fabricated from Kavo blocks, Group II; seven cores fabricated from CNU blocks, Group III; seven cores from CNU blocks and porcelain veneering for crowns. All specimens were cemented and sectioned into two planes; diagonal and bucco-lingual. The measurement of the marginal, internal, and occlusal fit was carried out using SEM ($S-4800^{(R)}$) at $30{\times}$. The results were analyzed by one-way ANOVA test. Results: The linear shrinkage of the CNU block and the KaVo block was 19.00% and 20.09%. The marginal gap of cores ($29.67{\pm}6.58{\mu}m$) fabricated from CNU blocks showed significantly smaller than that of the cores of Kavo blocks ($36.84{\pm}7.18{\mu}m$) (P < .05). The internal gaps of the porcelain veneered crowns ($32.23{\pm}6.33{\mu}m$) were larger than those of the other two groups ($37.57{\pm}6.81{\mu}m$ and $38.14{\pm}6.81{\mu}m$). Conclusion: No statistically significant difference was found in between experimental groups and control group. The experimental groups in marginal gap showed significantly smaller than the control group.

FEA estimates of margin design in all ceramic crowns (완전 도재관을 위한 지대치 형성시 변연 형태에 따른 응력 분포의 유한요소법적 비교)

  • Han, Sang-Hyun;Cho, Jung-Hyeon;Lee, En-Jung;Jeong, Suk-In;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Statement of problem: Over the past decade, increased demand for esthetically pleasing restorations has led to the development of all-ceramic systems. Recent reports suggest that the all-ceramic crowns have excellent physical properties, wear resistance, and color stability. In addition, numerous ceramics have excellent biocompatibility, a natural appearance, and improved physical bonding with resin composite luting agents. However, the brittle nature of ceramics has been a major factor in their restriction for universal usage. Functional occlusal loading can generate stress in the luting agent, and the stress distribution may be affected by the marginal geometry at the finish line. Tooth preparation for fixed prosthodontics requires a decision regarding the marginal configuration. The design dictates the shape and bulk of the all ceramic crowns and influences the fit at the margin. Purpose: The purpose of this study was to evaluate the stress distribution within marginal configurations of all- ceramic crowns (90-degree shoulder, 110-degree shoulder, 135-degree shoulder). Material and methods: The force is applied from a direction of 45 degrees to the vertical tooth axis. Three-dimensional finite element analysis was selected to determine stress levels and distributions. Results and conclusion: The result of stress level for the shoulder marginal configuration was more effective on stress distribution at 135-degree shoulder margin. But the stresses concentrated around at 135-degree shoulder margin. The stress decreased apically at the surface between cements and alumina core, and increased apically at the surface between alumina core and veneering porcelain.