• Title/Summary/Keyword: Vendors

Search Result 470, Processing Time 0.019 seconds

Implimentation of MMS using JNI (JNI를 이용한 MMS 구현)

  • Jang, Kyung-Soo;Shin, Dong-Ryeol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.1
    • /
    • pp.135-145
    • /
    • 2000
  • Manufacturing Message Specification (MMS) is designed as a communication standard protocol, ISO/IEC 9506, on factory automation for messaging between heterogeneous programmable unit controller, PLC, NC, Robot, of different vendors on the networks. MMS is also a standard protocol of OSI reference model application layer, In this paper, we show an implementation of MMS over TCP/IP using ANSI-C programming language on the unix environment, and make java classification using java native interface (NJI) with MMS library. The use of java classification provides a basic environment ot overcome a difficult programming with different MMS application programming interface (MMS-I) which requires a siklled programming technique of graphic user interface (GUI). In this paper, we implement a MMS application program of the automated assembly model for printed circuit board based on WWW which shows the operation, control and monitoring of real manufacturing device (RMD) with web browser providing users for consistent user interface.

  • PDF

Guidelines for Cardiovascular Magnetic Resonance Imaging from Korean Society of Cardiovascular Imaging (KOSCI) - Part 1: Standardized Protocol

  • Jo, Yeseul;Kim, JeongJae;Park, Chul Hwan;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Kim, Pan Ki;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.296-315
    • /
    • 2019
  • Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.

Implementation of FlexRay Protocol Specification and its Application to a Automobile Advance Alarm System (FlexRay 프로토콜 설계 및 자동차 경보 시스템 응용)

  • Xu, Yi-Nan;Yang, Sang-Hoon;Chung, Jin-Gyun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.98-105
    • /
    • 2008
  • FlexRay is a high-speed communications protocol with high flexibility and reliability. It was devised by automotive manufacturers and semiconductor vendors and implemented as on vehicle LAN protocol using x-by-wire systems. FlexRay provides a high speed serial communication, time triggered bus and fault tolerant communication between electronic devices for automotive applications. In this paper, we first design the FlexRay communication controller, bus guardian protocol specification and function parts using SDL (Specification and Description Language). Then, the system is re-designed using Verilog HDL based on the SDL source. The FlexRay system was synthesized using Samsung $0.35{\mu}m$ technology. It is shown that the designed system can operate in the frequency range above 76 MHz. In addition, to show the validity of the designed FlexRay system, the FlexRay system is combined with automobile advance alarm system in vehicle applications. The FlexRay system is implemented using ALTERA Excalibur ARM EPXA4F672C3. It is shown that the implemented system operates successfully.

Determination of ginsenosides in Asian and American ginsengs by liquid chromatography-quadrupole/time-of-flight MS: assessing variations based on morphological characteristics

  • Chen, Yujie;Zhao, Zhongzhen;Chen, Hubiao;Brand, Eric;Yi, Tao;Qin, Minjian;Liang, Zhitao
    • Journal of Ginseng Research
    • /
    • v.41 no.1
    • /
    • pp.10-22
    • /
    • 2017
  • Background: Asian ginseng and American ginseng are functional foods that share a close genetic relationship and are well-known worldwide. This article aims to investigate the correlation between morphological characteristics and the inherent quality of Asian and American ginsengs. Methods: In this study, an ultra-HPLC-quadrupole/time-of-flight MS (UHPLC-Q/TOF-MS) method was established for the quantitative analysis of 45 ginseng samples. The method developed for determination was precise and accurate. Results: The results showed that Asian ginseng samples with the same growing time (with the same or similar number of stem scars) that had a thinner main root, a longer rhizome and more branch roots contained greater amounts of ginsenosides. For American ginseng, two tendencies were observed in the relationship between the diameter of the main root and contents of ginsenosides. One tendency was that samples with thinner main roots tended to contain higher levels of ginsenosides, which was observed in the samples sold under the commercial name pao-shen. Another tendency was that samples with thicker main roots contained higher contents of ginsenosides, which was observed in the samples sold under the commercial name pao-mian, as well as in samples of American ginseng cultivated in Jilin, China. Conclusion: An approach using ultra-HPLC-quadrupole/time-of-flight MS was successfully established to link morphology and active components for evaluating the quality of Asian and American ginsengs. Clear correlation between visible morphological features and quality of Asian and American ginsengs was found. People can see the difference; this means consumers and vendors can evaluate ginseng by themselves.

Legal and Regulating Improvement for Distribution of Used Medical Equipments (중고 의료기기의 유통에 대한 법적 규제 개선)

  • Choi, Yong Jeon;Kwon, Jun Cheol;Jung, Yong Gyu
    • Journal of Service Research and Studies
    • /
    • v.4 no.1
    • /
    • pp.109-121
    • /
    • 2014
  • Used medical equipment utilized in medical technology, most are not human or environmental risks likely to in normal medical technology. Therefore, the risk is close to zero so that medical devices are classified into Class 1 medical device, such as little or no risk by treating. It can be minimized without arising unnecessary and waste of time. As handlers in the medical device vendors are expanding the area of the business, we can uplift operators' commitment to the business and for the people's choice. In this paper, our research are presented to improve the legal and regulatory directions for the distribution of used medical devicesin in order to establish and promote a fair deal of diversity.

  • PDF

The study of hot cathode ionization vacuum gauges (열음극 전리진공계 특성연구)

  • 홍승수;정광화;신용현;임종연;이상균
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.4
    • /
    • pp.277-284
    • /
    • 1998
  • To establish the calibration system of hot cathode ionization gauges as transfer gauges, researches were concentrated on measurements of the pressure ratio, the orifice conductance as well as the porous plug conductance of a ultrahigh vacuum standards system. Two ionization gauges obtained from two different vendors were calibrated in the pressure range of $7{times}10^{-7}$ to $4{times}10^{-3}$ Pa by injecting argon gas into the standards system. As a result, a 4% difference was revealed in non-linearity of the extractor ionization gauge due to the pressure difference between high vacuum and ultrahigh vacuum, and 3% for the stabil ionization gauge. It has been understood that the extractor ionization gauge is able to be used within the 10% error, the uncertainty of the extractor ionization gauge, if properly regulating the sensitivity of the gas. The stabil ionization gauge was also proved to be useable in the maximum error margin of 4% without the control of the gas sensitivity.

  • PDF

Study of Static Analysis and Ensemble-Based Linux Malware Classification (정적 분석과 앙상블 기반의 리눅스 악성코드 분류 연구)

  • Hwang, Jun-ho;Lee, Tae-jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.6
    • /
    • pp.1327-1337
    • /
    • 2019
  • With the growth of the IoT market, malware security threats are steadily increasing for devices that use the linux architecture. However, except for the major malware causing serious security damage such as Mirai, there is no related technology or research of security community about linux malware. In addition, the diversity of devices, vendors, and architectures in the IoT environment is further intensifying, and the difficulty in handling linux malware is also increasing. Therefore, in this paper, we propose an analysis system based on ELF which is the main format of linux architecture, and a binary based analysis system considering IoT environment. The ELF-based analysis system can be pre-classified for a large number of malicious codes at a relatively high speed and a relatively low-speed binary-based analysis system can classify all the data that are not preprocessed. These two processes are supposed to complement each other and effectively classify linux-based malware.

A Study on the Implementation of Register Based VXIbus System (Register Based VXIbus 시스템의 구현에 관한 연구)

  • 노승환;전동근;김성욱;강민호;김덕진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.11
    • /
    • pp.1219-1227
    • /
    • 1992
  • VXIbus is a standard for compatibility of instruments of multi-vendors and originated from the VMEbus. The devices for implementing VXIbus system can be categorized into the register based device and the message based device. In this paper we organized the A/D conversion module and the slot0 module, which form the register based VXIbus subsystem. The A/D conversion module is used as a digital voltmeter and LAN is used for communication between an external control computer and the slot0 module. The SCPI(Standard Commands for Programmable Instruments), which is a standard language for instruments, is transmitted from the external control computer to the slot0 module as the ASCII form, and then to the A/D conversion module after changing to the binary digit command. From the experiment. We verified that the measured voltage can be observed on external control computer and user interface can be improved by the modified graphic processing.

  • PDF

Malicious Traffic Detection Using K-means (K-평균 클러스터링을 이용한 네트워크 유해트래픽 탐지)

  • Shin, Dong Hyuk;An, Kwang Kue;Choi, Sung Chune;Choi, Hyoung-Kee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.2
    • /
    • pp.277-284
    • /
    • 2016
  • Various network attacks such as DDoS(Distributed Denial of service) and orm are one of the biggest problems in the modern society. These attacks reduce the quality of internet service and caused the cyber crime. To solve the above problem, signature based IDS(Intrusion Detection System) has been developed by network vendors. It has a high detection rate by using database of previous attack signatures or known malicious traffic pattern. However, signature based IDS have the fatal weakness that the new types of attacks can not be detected. The reason is signature depend on previous attack signatures. In this paper, we propose a k-means clustering based malicious traffic detection method to complement the problem of signature IDS. In order to demonstrate efficiency of the proposed method, we apply the bayesian theorem.

PinMemcheck: Pin-Based Memory Leakage Detection Tool for Mobile Device Development (PinMemcheck: 이동통신 기기 개발을 위한 Pin 기반의 메모리 오류 검출 도구(道具))

  • Jo, Kyong-Jin;Kim, Seon-Wook
    • The KIPS Transactions:PartA
    • /
    • v.18A no.2
    • /
    • pp.61-68
    • /
    • 2011
  • Memory error debugging is one of the most critical processes in improving software quality. However, due to the extensive time consumed to debug, the enhancement often leads to a huge bottle neck in the development process of mobile devices. Most of the existing memory error detection tools are based on static error detection; however, the tools cannot be used in mobile devices due to their use of large working memory. Therefore, it is challenging for mobile device vendors to deliver high quality mobile devices to the market in time. In this paper, we introduce "PinMemcheck", a pin-based memory error detection tool, which detects all potential memory errors within $1.5{\times}$ execution time overhead compared with that of a baseline configuration by applying the Pin's binary instrumentation process and a simple data structure.