• Title/Summary/Keyword: Velocity Deviation

Search Result 311, Processing Time 0.025 seconds

Characteristic of Wind Flow around Building Structures for Wind Resource Assessment (풍자원 평가를 위한 건축물 주변의 유동특성)

  • Cho, Kang-Pyo;Jeong, Seung-Hwan;Shin, Seung-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.50-58
    • /
    • 2011
  • To utilize wind resources effectively around buildings in urban area, the magnitudes of wind velocity and turbulence intensity are important, which means the need of the information about the relationship between the magnitude of wind velocity and that of fluctuating wind velocity. In the paper, wind-tunnel experiments were performed to provide the information about Characteristic of Wind flow around buildings with the spanwise distance and the side ratio of buildings as variables. For a single building with the side ratios of one and two, the average velocity ratio was 1.4 and the velocity standard deviation ratio ranged from 1.4 to 2.6 at the height of 0.02m at the corner of the windward side, in which flow separation occurred. For twin buildings with the side ratios of one and two, the velocity ratio ranged from 2 to 2.5 as the spanwise distance varied at the height of 0.02m, and the velocity standard deviation ratio varied near 1.25. For twin buildings with the side ratios of one and two, the maximum velocity ratio was 1.75 at the height of 0.6m, and the maximum velocity standard deviation ratio was 2.1. It was also found from the results of CFD analysis and wind-tunnel experiments that for twin buildings with the side ratios of one and two, the difference between the velocity ratio of CFD analysis and that of wind-tunnel experiments at streamwise distances was near 0.75.

The Minimum Fluidization Velocity of Gaussian Distribution Particle System According to Standard Deviation (Gaussian 분포의 입자군의 표준편차에 따른 최소유동화속도)

  • Jang, Hyun Tae;Park, Tae Sung;Cha, Wang Seog
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.567-570
    • /
    • 2008
  • The present study investigated the applicability of the minium fludization velocity measuring method using linear regression analysis between the standard deviation of pressure fluctuation and gas velocity in multi-particle sand on a fluidized bed 0.109 in inner diameter. We measured minium fludization velocity according to the standard deviation of particle distribution in Gaussian distribution. The measured value compared with other researchers' equations. The minium fludization velocity derived from the linear regression analysis of the standard deviation of pressure fluctuation and pressure drop inside the bed. We also found that the minium fludization velocity of a multi-particle system using the standard deviation of pressure fluctuation must be measured at freely bubbling region.

NUMERICAL STUDY ON FLOW CHARACTERISTIC IN THE HEAT RECOVERY STEAM GENERATOR (배열회수장치의 유동특성에 관한 수치적 연구)

  • Choi, H.K.;Yoo, G.J.;Shin, B.J.;Kim, C.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2010
  • Performance improvements of the heat recovery steam generator(HRSG) can be achieved by improving the flow distribution of exhaust gases for a various type of different equipments. A number of design parameters are systematically investigated and their effects on an index of velocity deviation established. The parameters include the three shape of the transition duct and the wide range of the guide vane angles. The numerical results clearly reveal feature of the flow pattern in the transition duct, velocity deviation and pressure drop at tube bank part.

A Study on Error Characteristics of Large Size Electromagnetic Flowmeter in the Range of Low Velocity (저유속 영역에서 대구경 전자기유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • The large size electromagnetic flowmeter was tested to investigate the variation of its error characteristics in the range of low velocity under 0.6 m/s using flowmeter calibration system. For the two case of valve opening rate 100 % and 50 %, these tests were undertaken three times each for twelve velocity condition from $0.05\;^m/s\;to\;0.6\;^m/s$ with increment of $0.05\;^m/s$. It is shown that error characteristic of electromagnetic flowmeter was stabilized within ${\pm}0.4%$ of rate both higher than $0.25^m/s$ of velocity condition and 50 % of valve opening position. But, measurement deviation of flowmeter for ${\Phi}400mm\;and\;{\Phi}600mm$ was out of expected deviation range. It is necessary to correction with calibration. In conclusion, error characteristic of electromagnetic flowmeter wasn't changed proportion to its size.

Comparison of improvement on Low back pain depending on male inpatient's Pulse wave velocity (남성 입원환자들의 맥파속도에 따른 요통 호전도의 비교 연구)

  • Lee, Jin-Hyuk;Sui, Mu-Chang;Min, Kwan-Sik;Lee, Han;Jeong, Ho-Seok
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.4 no.2
    • /
    • pp.39-45
    • /
    • 2009
  • Objectives : The aim of this study is to compare the improvement of Low back pain (LBP) depending on male Inpatient's Brachlalankle Pulse Wave Velocity (baPWV), Method : We evaluated 35 LBP inpatients who took pulse wave velocity test during admission at Jaseng hospital from November 2008 to september 2009. We used applanation tonometry method to measure pulse wave velocity and numerical rating scale to measure patient's improvement. Result : At admission, standard deviation of normal group's NRS was $7.44{\pm}1.67$ and high risk group's was $7.57{\pm}2.09$(P=0.678). After 5 days of admission, standard deviation of normal group's NRS was $5.67{\pm}1.94$ and high risk group's was $6.00{\pm}2.17$(P=0.680). After 10 days of admission, standard deviation of normal group's NRS was $4.00{\pm}1.80$ and high risk group's was $4.95{\pm}1.96$(P=0.281). After 15 days of admission, standard deviation of normal group's NRS was $2.89{\pm}1.62$ and high risk group's was $4.10{\pm}1.92$(P=0.124). At discharge, standard deviation of normal group's NRS was $5.11{\pm}1.69$ and high risk group's was $4.86{\pm}2.08$(P=0.504). Comparison between admission and discharge, standard deviation of normal group's NRS was $5.11{\pm}1.69$ and high risk group's was $4.86{\pm}2.08$(P=0.504) Conclusion : Low back patients with high Brachialankle Pulse Wave Velocity, showed slower improvement rate compare to patients within normal rate. But statically, had no significance.

  • PDF

GPS Surveying by A Point Positioning (일점측위에 의한 GPS측정)

  • Lee, Y.H.;Mun, D.Y.
    • Journal of Korean Port Research
    • /
    • v.12 no.1
    • /
    • pp.119-130
    • /
    • 1998
  • As a satellite positioning system, GPS is designed to provide the information on three dimensional position, velocity, and time all over the world. The purpose of this paper is to obtain what day has the best accuracy and what time has the best accuracy of measuring of forteen-twenty mimutes for effective using of MAGELLAN G.P.S NAV DLX-10 system. The result of measurement maximum deviation value from November, 1997 to March, 1998 that latitude deviation is 3' .75 and longitude deviation is 2' .1 And the result of measurement maximum deviation value during fourteen minutes of April 29, 1998 that latitude deviation is 3' .75 and longitude deviation is 1' .9. The result of measurement maximum deviation value during twenty minutes of May 6, 1998 that latitude deviation is 4' .75 and longitude deviation is 2' .1 and that is provid 3' .25, 4' .1 to May 13, 1998. So, we expect efficient use of horizontal position for navigation.

  • PDF

Micro PIV measurements of two-fluid flows in a microchannel (Micro-PIV 기법을 이용한 미세유로 내 두 유체 유동 측정)

  • Sung Hyung Jin;Kim Byoung Jae;Liu Ying Zheng
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.90-93
    • /
    • 2004
  • Micro PIV was applied to measure velocity profiles of two-fluid flows in a microchannel. In this work, the two-fluid flow of two glycerol-water mixtures was measured for three cases $(\phi=0\;and\;\phi=0.2;\;\phi=0.1\;and\;\phi=0.5;\;\phi=0\;and\;\phi=0.6)$. The flow rates of two fluids were the same. The experimental velocity profiles agreed well with numerical simulations. However, a slight deviation was found in the fluid with low concentration. Rather than the effects of the varying refractive indices inside the channel, the high velocity gradient effect was thought as the main source of the deviation.

  • PDF

Validity of Wind Generation in Consideration of Topographical Characteristics of Korea (지형에 따른 예상풍력발전단지에 관한 고찰)

  • Moon, Chae-Joo;Jung, Kwen-Sung;Cheang, Eui-Heang;Park, Gui-Yeol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.81-84
    • /
    • 2008
  • This paper discussed the validity of wind force power generation in consideration of the topographical characteristics of Korea. In order to estimate the exact generation of wind power plants, we analyzed and compared wind resources in mountain areas and plain areas by introducing not only wind velocity, the most important variable, but also wind distribution and wind standard deviation that can reflect the influence of landform sufficiently. According to the results of this study, generation was higher at wind power plants installed in southwestern coastal areas where wind velocity was low than at those installed in mountain areas in Gangwondo where wind velocity was high. This suggests that the shape parameter of wind distribution is low due to the characteristics of mountain areas. and the standard deviation of wind velocity is large due to the effect of mountain winds, and therefore, actual generation is low in mountain areas although wind velocity is high.

  • PDF

Line Tracer와 Jansen Mechanism을 이용한 보행 로봇 설계

  • Kim, Yeong-Du;Bang, Jeong-Hyeon;Choe, Yeong
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.592-594
    • /
    • 2017
  • 한국연구재단의 지원을 받는 EDISON CHANLLENGE를 수행하기 위해 작성되었다. 본 논문은 얀센 메커니즘과 아두이노, 적외선 센서를 이용하여 라인 트래이싱을 하기 위해, 최적의 얀센 메커니즘을 설계한다. MATLAB을 이용하여 시뮬레이션을 진행하였다. Ground Score, Average Velocity, Drag Score, 그리고 Standard Deviation of Velocity를 이용하여 최적의 얀센 메커니즘을 설계하였다.

  • PDF