• Title/Summary/Keyword: Vein graft

Search Result 235, Processing Time 0.021 seconds

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF

Femoral Vein Thrombosis Associated with Distal Femoral Osteochondroma - A Case Report - (원위 대퇴골 골연골종으로 인한 대퇴 정맥 혈전증 - 증례 보고 -)

  • Oh, Joo-Han;Kim, Jae-Yoon;Gong, Hyun-Sik;Kim, Woo-Sung;Shin, Sang-Ik
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.83-88
    • /
    • 2006
  • Osteochondroma is a hyperplasic bony lesion caused by subperiosteal displacement of physeal cartilages, and the most common benign bone tumor. Osteochondromas rarely cause vascular complications, but when encountered, acute ischemia, phlebitis, and arterial puncture are the most common. They are caused by the mass effect or by the sharp end of the tumor. Deep vein thrombosis may be caused by impaired venous blood flow or a hypercoagulable blood state, but sometimes no predisposing cause can be found. We experienced a patient with deep vein thrombosis caused by the mass effect of an asymptomatic osteochondroma, and treated him successfully by excising the osteochondroma and performing a saphenous vein graft after resecting obstructed vein.

  • PDF

Comparison of Radial Artery and Saphenous Vein Composite Y Grafts during Off-pump Coronary Artery Bypass

  • Wi, Jin-Hong;Joo, Hyun-Chel;Youn, Young-Nam;Song, Suk-Won;Kim, Tae Hoon;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.265-273
    • /
    • 2013
  • Background: The safety and efficacy of arterial composite grafts for total arterial revascularization have been demonstrated. The saphenous vein (SV) is a widely used graft because of its accessibility, sufficient length, and ease of manipulation. Our aim was to compare mid-term outcomes of saphenous vein Y-grafts with radial artery Y-grafts joined by anastomosis to the left internal thoracic artery. Materials and Methods: Records of off-pump coronary artery bypass grafting with composite Y-grafts based on the left internal thoracic artery technique in 552 patients were analyzed retrospectively. After propensity score matching, 79 radial arterial (RA) composite grafts (RA group) and 79 saphenous vein composite grafts (SV group) were compared. The duration of mean follow-up was $24.6{\pm}14.6$ months (range, 1 to 55 months). Results: There were no differences in surgical mortality, all-cause mortality, or morbidity among the groups. Rates of 4-year survival were 91.7% and 96.3% in the RA and SV groups, respectively (p=0.519). The coronary reintervention-free survival rate and freedom from major adverse cardiovascular or cerebrovascular events were similar in the two groups (p=0.685, p=0.564). Conclusion: Construction of composite Y-grafts using the radial artery or saphenous vein showed similar mid-term results. Long-term follow-up and randomized trials will be needed to confirm our present conclusions.

Morphological Traits of Selected Chestnut Races and its Propagation Studies (밤나무 우량품종(優良品種)의 형태학적(形態學的) 특징(特徵)과 증식(增殖)에 관(關)한 연구(硏究))

  • Yim, Kyong-Bin;Kwon, Ki-Won
    • Journal of Korean Society of Forest Science
    • /
    • v.22 no.1
    • /
    • pp.49-62
    • /
    • 1974
  • 1. In the comparison of survival ratio among three different methods(bark graft, veneer graft, root graft), bark graft showed the highest survival ratio and root graft was the lowest. It was shown to be significant at the level of 5% in the analysis of variance for the results. It was able to be supposed that one of the main causes for the results was the different amounts of ferric tannic acid which was formated owing to the reaction of grafting knife with tannic acid oozing from cutting faces of the tree. In juvenile tissue graft, the survival ratio of inverted radicle graft was a little higher than that of juvenile stem graft, but there was no significant difference between two methods in analysis of variance. 2. The most hairs of chestnut tree leaves were recognized as stellates on the most part of leaves except for venation. The number of rays in the stellates was ranged from 4 to 8 generally. It was shown to be highly significant differences at the level of 1% among the each race growing at the similar environmental condition in the length of ray and the distributed ratio of the stellates having different ray number. 3. Excepting for the basal width of serration there were no significant differences between $Imakita_1$, $Imakita_2$ as well as between $Teteuchi_1$, $Teteuchi_2$ at the each point of experimental items in this study. Such results made this study more useful. 4. Among the races that were growing in the similar environmental condition, there were highly significant differences at the level of 1% in the length and the width of serration. 5. The rolling of hair, the angle of serration from the leaf margin, the existence of lateral vein in the serration, the intrusion of main vein into the serration and the width of main vein were observed to be somewhat useful as the subsidiary methods for the identification of chestnut races.

  • PDF

Reduced Burst Release from ePTFE Grafts: A New Coating Method for Controlled Drug Release

  • Nam, Hye-Yeong;Kim, Dae-Joong;Lim, Hyun-Jung;Lee, Byung-Ha;Baek, In-Su;Park, Sang-Hun;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.422-426
    • /
    • 2008
  • Hemodialysis graft coated with paclitaxel prevents stenosis; however, large initial burst release of paclitaxel causes many negative effects such as drug toxicity and inefficient drug loss. Therefore we developed and tested a novel coating method, double dipping, to provide controlled and sustained release of paclitaxel locally. Expanded polytetrafluoroethylene (ePTFE) grafts were dipped twice into a solution of several different paclitaxel concentrations. In vitro release tests of the double dipping method showed that early burst release could be somewhat retarded and followed by sustained release for a long time. We observed the effect of paclitaxel coating by double dipping in porcine model of arterio-venous (AV) grafts between the common carotid artery and the external jugular vein. 12 weeks after constructing AV grafts, cross sections of the graft venous anastomosis were obtained and analyzed. Paclitaxel coated ePTFE grafts by double dipping were observed to prevent neointimal hyperplasia and therefore reduced stenosis of the arteriovenous hemodialysis grafts, especially at the graft venous anastomosis sites. Our results demonstrate that second dipping of ePTFE graft, which was already coated once with paclitaxel, washes off the drug on a surface of the graft and affects the ratio of paclitaxel on the surface to that of the inner space, possibly by diffusion: thus the early burst of drug can be somewhat reduced.

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

Bilateral Partitioning of Systemic Venous Chamber in Conjunction with Atriopulmonary Anastomoses [Fontan - Kreutzer] - A new technique - (체정맥환류이상을 동반한 복잡심기형환자에 있어 체정맥심방 양분을 이용한 Fonatan 씨 술식 체험 -새로운 수술방법-)

  • Kim, Jin-Guk;Kim, Yong-Jin;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.21 no.5
    • /
    • pp.948-953
    • /
    • 1988
  • A technique applicated for physiologic correction of complex congenital cardiac disease suitable for Fontan procedure in which drainage of left superior vena cava and hepatocardiac vein to left atrium combined is described. We made one systemic venous baffle from left hepatocardiac vein to left superior vena cava and another systemic venous baffle from right inferior vena cava to the right superior vena cava with rigid prosthetic material[0.5mm thickness PTFE patch]. And then we anastomosed directly between the right sided atrial appendage and right pulmonary artery, and left-sided atrial wall beneath the appendage and left pulmonary artery. We believe that this procedure is superior to the method using intraatrial tube graft to divert the left hepatocardiac venous blood to right atrium, and applicable for physiologic correction of any complex congenital cardiac disease suitable for Fontan-type procedure in which anomalies of systemic venous drainage combined.

  • PDF

False aneurysm of right common carotid artery due to gun shot wound: report of a case (총창으로 인한 우측 총경동맥의 가성 동맥류 치험 1)

  • 남구현
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.488-491
    • /
    • 1984
  • Vascular injuries from gun shot wound is rare in these days, in Korea. A Case of false aneurysm of the right common carotid artery due to penetrating injury to the neck by carbine. The confirmatory diagnosis was made by right carotid angiogram which revealed bean-sized aneurysmal sac at the mid-portion of the right common carotid artery. Despite of no symptoms, emergency false aneurysmectomy and reconstruction with on-lay vein patch graft using left greater saphenous vein for threat of rupture and embolization from mural thrombi. During repair of common carotid artery, cerebral circulation was maintained with internal shunt. The postoperative course was uneventful except limit of motion of right upper extremity due to initial injury.

  • PDF

Surgical treatment of unstable angina -Experience in 6 patients- (불안정형 협심증의 외과적 치료 -6예 경험-)

  • 조형곤
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.595-605
    • /
    • 1986
  • From February 1986 through September 1986, the authors have experienced 6 cases of coronary artery bypass graft for patients with unstable angina. There were five males and one female who ranged from 39 to 65 years [mean, 53.3 years]. The extent of coronary disease was as follows: one-, two- and three-vessel diseases, all 2 cases respectively, and among them, 1 case had left main disease. Distal anastomoses were performed first with using saphenous vein grafts as conduits in all cases and sequential bypass methods were employed in 5 cases. Numbers of vein grafts were two in 2 cases and one in 4 cases. The mean time wasted for one distal anastomosis was 36 minutes. Post operative complications were leg-wound disruption [2 cases], transient psychosis [1 case] and perioperative myocardial infarction [MI] [1 case]. Sixty three year-old male patient associated with cardiomegaly, prior MI, ventricular arrhythmia, cardiac dysfunction and endocrinologic diseases preoperatively was expired in the operating room due to perioperative Ml. All survivors were asymptomatic and on discontinuing medical therapy on follow-up varying from 1 to 8 months.

  • PDF

Chondrocutaneous posterior auricular artery perforator free flap for single-stage reconstruction of the nasal tip: a case report

  • Lee, Jun Yong;Seo, Jeong Hwa;Jung, Sung-No;Seo, Bommie Florence
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.6
    • /
    • pp.337-340
    • /
    • 2021
  • Full-thickness nasal tip reconstruction is a challenging process that requires provision of ample skin and soft tissue, and intricate cartilage structure that maintains its architecture in the long term. In this report, we describe reconstruction of a full-thickness nasal tip and ala defect using a posterior auricular artery perforator based chondrocutaneous free flap. The flap consisted of two lay ers of skin covering conchal cartilage, and was based on a perforating branch of the posterior auricular artery. A superficial vein was secured at the posterior margin. The donor perforator was anastomosed to a perforating branch of the lateral nasal artery. The superficial vein was connected to a superficial vein of the surrounding soft tissue. The donor healed well after primary closure. The flap survived without complications, and the contour of the nasal rim was sustained at follow-up 6 months later. As opposed to combined composite reconstructions using a free cartilage graft together with a small free flap or pedicled nasolabial flap, the posterior auricular artery perforator free flap encompasses all required tissue types, and is similar in contour to the alar area. This flap is a useful option in single-stage reconstruction of nasal composite defects.