• Title/Summary/Keyword: Vault

Search Result 215, Processing Time 0.021 seconds

Analysis of the Research Trend of Artistic Gymnastics on the Sports Biomechanics (기계체조의 운동역학적 연구동향 분석)

  • Han, Yoon-Soo;Kwon, Oh-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.93-101
    • /
    • 2007
  • The purpose of this study was to analyze the research trends of artistic gymnastics on the kinetics. This study analyzed the 76 published papers in the Journal of Korean Alliance for Health, Physical Education, Recreation & Dance and Korean Journal of Sport Biomechanics between 1995 and 2006. Papers were split into two groups for analysis, 1995-1999 and 2000-2006, and classified according to research methods, areas, and main topics. Conclusions are as follow. First, method of research were kinematical research(80.3%), kinetic(17.1%), and EMG research(2.6%). Second, areas of research were hi-bar(31.6%), vault(23.7%), parallel bars(21.1%), floor exercise(13.2%), rings(3.9%), balance beam(3.9%), uneven bars(2.6%). Last, main topic of research were focused on vault Tsukahara skill(13.9%), hi-bar flight skill(11.4%), parallel bars support skill(10.1%), hi-bar dismount skill(8.9%), floor exercise salto skill(8.9%).

Mechanical Behavior and Cracking Characteristics of Tunnel Lining by Model Experiment (모형 실험에 의한 터널 복공의 역학적 거동 및 균열 특성에 관한 연구)

  • 이대혁;김영근;이희근
    • Tunnel and Underground Space
    • /
    • v.8 no.1
    • /
    • pp.53-66
    • /
    • 1998
  • Considering the mechanical cracking in the concrete lining of tunnels occurring in relatively short period of time after the construction, there is a need for the study on the mechanical behavior and the cracking characteristics of double lining support system(shotcrete and concrete lining). For the proposed study, downscaled lining models of Kyung-Bu High Speed Railway tunnels were tested. Most longitudinal cracks at about 93 percentage developed within 30 arch degree from the vault. Cracking load was about 30 percentage of the failure load and the deflection under the cracking load was 10 percentage of the deflection under the failure load. The overbreak around the vault contributed to the reduction of the capacity for cracking and failure by the percentage greater than the reduced effective depth. Of several rock block types considered in this research, the triangular block was the most critical, and the right triangular block under eccentric load was secondly critical for the stability of the tunnel lining system. The dimensionless support reaction curves were derived from the experimental results for single and double lining. The general equation to compute the designed flexural moment was modified.

  • PDF

The analysis for flooding prevention countermeasures of Electrical facility and Transformer Vault on Foreign (국외 수변전실 및 지상 전력기기 침수방지 대책에 관한 조사연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong;Lee, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.305-307
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-tying shore by heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment (Pad-mounted Transformer and Switch). So we research the flooding prevention countermeasures of electrical facility and Transformer Vault on Foreign. We conform the site facility and related regulation for flooding prevention on Foreign.

  • PDF

The analysis of Yurchenko's 900 Degree Twist Technique with Stretched Body (도마 Yurchenko 몸 펴 900도 비틀기 기술 분석)

  • Yeo, Hong-Chul
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.165-173
    • /
    • 2006
  • The purpose of this study was to analyze Yurchenko's 900 degree twist technique between the highly scored and the lowly scored subjects during the 2003 TaeGu Universiad Championship. The following results was obtained by analyzing horizontal, vertical and resultant velocities on 1st, 2nd, 3rd and 4th phases. The highly scored subject took longer total performance time but shorter time in 2nd and 300 phases. The highly scored subject also took longer performance time in 4th phase. In the board contact phase the highly scored subject had bigger elbow joint angle and shoulder joint angle. The highly scored subject had longer flying time and had more higher vertical height but lower horizontal and resultant velocities on 4th phase.

Optimal design of double layer barrel vaults considering nonlinear behavior

  • Gholizadeh, Saeed;Gheyratmand, Changiz;Davoudi, Hamed
    • Structural Engineering and Mechanics
    • /
    • v.58 no.6
    • /
    • pp.1109-1126
    • /
    • 2016
  • The present paper focuses on size optimization of double layer barrel vaults considering nonlinear behavior. In order to tackle the optimization problem an improved colliding bodies optimization (ICBO) algorithm is proposed. The important task that should be achieved before optimization of structural systems is to determine the best form having the least cost. In this study, an attempt is done to find the best form then it is optimized considering linear and non-linear behaviors. In the optimization process based on nonlinear behavior, the geometrical and material nonlinearity effects are included. A large-scale double layer barrel vault is presented as the numerical example of this study and the obtained results indicate that the proposed ICBO has better computational performance compared with other algorithms.

A Case of Canine Hydrocephalus with Nonsuppurative Encephalitis (비화농성 뇌염을 동반한 개 수두증 1례)

  • 한정희;서강문
    • Journal of Veterinary Clinics
    • /
    • v.17 no.2
    • /
    • pp.470-474
    • /
    • 2000
  • A Shih Tzu Puppy had clinical onset of anotexia crying and progression of neurological sings when enlargement of the cranial vault at 1 month old and died after showing clinical signs during 2 months period. Radiological and pathological examinations were performed. Radiological findings were homogeneous appearance of the calvaria with cortical thinning, loss of the normal convolutional skull markings and persistent fontanelles. Grossly enlargement of the cranial vault thinning of the bone and defective closure of the fontanelles were also observed. The entire subcortical area of the cerebral hemispheres with severe, dilatation of ventricles and cerebrospinal fluid(CSF) wits absent. There was parenchyma atrophy affecting chiefly in the white mater and the cerebral cortices, axon degeneration and necrosis and gitter cell infiltration in the whiter matter and the subependymal area. Mononuclear perivacular cuffing in the cerebrum and the pons was shown. Based on the radiological, gross and histopathological findings, this case was believed to have congenital hydrocephalus with nonsuppurative encephahitis. Possible etiology on the case is also discussed.

  • PDF

A Case Study on the Safety Assessment for Groundwater Pathway in a Near-Surface Radioactive Waste Disposal Facility

  • Park, Joo-Wan;Chang, Keun-Moo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.232-241
    • /
    • 2002
  • A safety assessment is carried out for the near-surface radioactive waste disposal in the reference engineered vault facility. The analysis is mainly divided into two parts. One deals with the release and transport of radionuclide in the vault and unsaturated zone. The other deals with the transport of radionuclide in the saturated zone and radiological impacts to a human group under well drinking water scenario. The parameters for source-term, geosphere and biosphere models are mainly obtained from the site specific data. The results show that the annual effective doses are dominated by long lived, mobile radionuclides and their associated daughters. And it is found that the total effective dose for drinking water is far below the general criteria of regulatory limit for radioactive waste disposal facility.

The inspection and seismic design method of electrical facility instated in the building (건축물에 시설되는 수변전설비 내진설계 및 검사 방법에 관한 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Kang, Min-Hee;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.332-335
    • /
    • 2009
  • Incase of not considered seismic design at transformer vault which is made of many informant electrical facility, facility is damaged, electrical fire breaks out and second damage is able to break out at generating earthquake. But seismic design yet is not applied to at transformer vault in the country. Regard to seismic design method of electrical facility installed in the building internal, we present the seismic design of electrical facility using "Building construction design standard" in internal and "Manual of seismic design and construction for Building Electrical facility" in japan. This paper will be used detail seismic design of pipe and facility. reliability inspection plan for seismic design and construction of electrical facility

  • PDF

Multi-biometric feature based fuzzy vault (다중 생체 특징 기반 퍼지볼트)

  • Sohn, Ho-Sik;Ro, Yong-Man
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.1057-1060
    • /
    • 2008
  • 생체 암호 시스템에서 키로 사용하는 인간의 생체 특징은 외부 환경이나 인간적 요소를 포함하고 있기 때문에 항상 같은 개수, 같은 값의 데이터를 얻을 수 없는 불확실성을 가지고 있다. 퍼지볼트 체계 (Fuzzy vault scheme) [1]는 이러한 불확실성을 가지고 있는 데이터의 특성을 효과적으로 반영 할 뿐만 아니라, 등록된 생체 데이터의 보안을 보장해 주는 알고리즘으로서 얼굴, 지문이나 홍채와 같은 단일 생체 특징으로의 적용 방법이 소개되어 왔다 [2,4,5]. 본 논문에서는 퍼지볼트 시스템의 인식 성능을 높이기 위해 이러한 단일 생체 데이터의 불확실성을 보완할 수 있는 다중 생체 특징 (얼굴과 지문) 데이터를 퍼지볼트 체계에 적용하는 방법을 제안하고 실효성을 검증한다.