• Title/Summary/Keyword: Vascular measurement

Search Result 121, Processing Time 0.029 seconds

A Review on Clinical Research of Acupuncture Using Electroencephalogram (뇌파를 평가도구로 사용한 침 중재 임상연구 동향)

  • Lim, Jung-Hwa;Cho, Jun-Hee;Kim, Jae-Hyo;Kim, Lakhyung;Kang, Hyung-Won;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.32 no.4
    • /
    • pp.345-378
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the recent trends of clinical research on acupuncture using electroencephalogram (EEG) as the outcome measurement. Methods: Nine domestic and foreign databases were searched to collect related studies published up to November 3, 2021. The participants, intervention, outcomes, results of the included studies were extracted and analyzed. Results: A total of 18 studies were selected. Neurological diseases and mental disorders were included in most studies, and vascular dementia were most frequently investigated. Electroacupuncture and body acupuncture intervention were most frequently conducted in seven studies. The most commonly used outcomes using EEG was EEG abnormality. However, in most studies there was accurate description of the EEG measurement. Most studies showed significant difference in EEG outcomes after intervention. The quality of included studies was poor. Conclusions: EEG as diagnostic markers and outcome measurements is increasingly studied. Standardized EEG measurement and the consistent EEG finding for specific diseases are needed to perform the future rigorous studies on EEG as diagnostic and outcome tools.

A Study of The Correlativity in EAV(Electroacupuncture According to Voll)measurement valvues, Sasang Constitution Classfication and CVA(Cerebrovascular accident) (EAV의 측정치(測定値)와 사상체질유형(四象體質類型) 및 중풍(中風)과의 상관성(相關性)에 관한 연구(硏究))

  • Kim, Jong-Weon;Ko, Bung-Hee;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.7 no.2
    • /
    • pp.59-88
    • /
    • 1995
  • Three groups have participated in this study. 1) The first group consists of 57 patients were who had been treated in the Oriental Medical Hospital at Kyung Hee Medical Center. 2) The second group consists of 37 outpatients who had been treated in the Oriental Medical Hospital at Kyung Hee Medical Center. 3) The third group consists of 76 students of the Oriental Medical School at Kyung Hee University. The following conclusions were made in comparison with EAV measurement values, SaSang Constitution Classfication and CVA. 1. The following conclusions were made in comparison with EAV measurement values and Type(SaSang Constitution Classfication). 1) The analsis of the Correlation in Normal group with EAV measurement values and Type(SaSang Constitution Classfication). 2) The analysis of the correlation in patient group with EAV measurement values showed significant differences in Right meridians(Nerval degeneration vessel, Circulation, Allergy) and in Left meridian(Liver). 3) The analysis of the correlation in Total(Normal+patient)group with EAV measurement values showed significant differences in Right meridians(Large intestine, Nerval degeneration vessel, Circulation, Allergy, Pancreas) and in Left meridians(Lymph vessel, Nerval degeneration vessel, Spleen, liver). 4) The above results showed common-significant differences in Right Allery meridian and in Left Liver meridian. 2. The analysis of the correlation in EAV measurement values and Group (Cerebrovascular accident) showed significant differences in Right meridians(Lymph vessel, Lung, Nerval degeneration vessel, Allergy, Paren & Epith. degeneration vessel, Triple warmer, Heart, Pancreas, Stomach, Fibroid degeneration vessel, Skin, Fatty degeneration vessel, Heart, Stomach, Fibroid degeneration vessel, Skin, Fatty degeneration vessel, Bile duct, Kidney). 3. The analysis of the correlation in EAV measurement values and Para(GROUPS according to PARALYSIS)showed significant differences in Left Stomatch meridian. The analysis of the correlation in EAV measurement values and Para(GROUPS according to PARALYSIS) about the differance of right measurement values and left measurement values showed significant differences in Nerval degeneration vessel, Stomatch, Gall bladder & Bile duct, Kidney and Urinary Bladder meridians. 4. The analysis of the correlation in EAV measurement values and Compl(GROUPS according to COMPLICATION with CVA)showed significant differences in Right meridians(Lymph vessel, Articular degeneration vessel, Fatty degeneration vessel) and in Left meridians(Lung, Stomatch, Fatty degeneration vessel). 5. The analysis of the correlation in Type and MORPHOROGICAL DIAGRAMING (HTOUPS according to MORPHOROGY) showed significant differences in Cranium region, Chest region, Stomatch region and Umbilicum region. 6. The analysis of the correlation in BAZ measurement values and Group(Cerebral Vascular Attack)showed significant differences, the analysis on the correlation of BAZ measurement values and Type(SaSang Constitution Classfication) didn't show any significant differences. 7. In comparison with Actual measurement vales and Voll's measurement values, BAZ measurement values agree with Voll's measurement values but CMP measurement values lower than the Voll's measurement values. Later We have to research further about classifications of race, age, sex etc. The EAV measurement values have Group(Cerebrovascular accident) more correlative than Type(SaSang Constitution Classfication). The EAV may well be that it will be used as an accessory method in SaSang Constitution Classfication and as a diagnostic method in medicine too.

  • PDF

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.

Korean Society of Heart Failure Guidelines for the Management of Heart Failure: Management of the Underlying Etiologies and Comorbidities of Heart Failure

  • Sang Min Park;Soo Youn Lee;Mi-Hyang Jung;Jong-Chan Youn;Darae Kim;Jae Yeong Cho;Dong-Hyuk Cho;Junho Hyun;Hyun-Jai Cho;Seong-Mi Park;Jin-Oh Choi;Wook-Jin Chung;Seok-Min Kang;Byung-Su Yoo;Committee of Clinical Practice Guidelines, Korean Society of Heart Failure
    • Korean Circulation Journal
    • /
    • v.53 no.7
    • /
    • pp.425-451
    • /
    • 2023
  • Most patients with heart failure (HF) have multiple comorbidities, which impact their quality of life, aggravate HF, and increase mortality. Cardiovascular comorbidities include systemic and pulmonary hypertension, ischemic and valvular heart diseases, and atrial fibrillation. Non-cardiovascular comorbidities include diabetes mellitus (DM), chronic kidney and pulmonary diseases, iron deficiency and anemia, and sleep apnea. In patients with HF with hypertension and left ventricular hypertrophy, renin-angiotensin system inhibitors combined with calcium channel blockers and/or diuretics is an effective treatment regimen. Measurement of pulmonary vascular resistance via right heart catheterization is recommended for patients with HF considered suitable for implantation of mechanical circulatory support devices or as heart transplantation candidates. Coronary angiography remains the gold standard for the diagnosis and reperfusion in patients with HF and angina pectoris refractory to antianginal medications. In patients with HF and atrial fibrillation, longterm anticoagulants are recommended according to the CHA2DS2-VASc scores. Valvular heart diseases should be treated medically and/or surgically. In patients with HF and DM, metformin is relatively safer; thiazolidinediones cause fluid retention and should be avoided in patients with HF and dyspnea. In renal insufficiency, both volume status and cardiac performance are important for therapy guidance. In patients with HF and pulmonary disease, beta-blockers are underused, which may be related to increased mortality. In patients with HF and anemia, iron supplementation can help improve symptoms. In obstructive sleep apnea, continuous positive airway pressure therapy helps avoid severe nocturnal hypoxia. Appropriate management of comorbidities is important for improving clinical outcomes in patients with HF.

HISTOMORPHOLOGIC CHANGE AND REGENERATION OF THE ADVENTITIA-STRIPPED AND FROZEN RAT FEMORAL ARTERY:HISTOLOGIC, HISTOMORPHOMETRIC, IMMUNOHISTOCHEMICAL AND SCANNING ELECTRON MICROSCOPIC STUDY (백서 대퇴동맥 외막층 제거후 혈관동결시 조직형태학적 변화 및 재생에 관한 연구)

  • Kim, Tae-Deug;Kim, Kyung-Wook;Lee, Jae-Hoon;Kim, Chang-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.281-294
    • /
    • 1999
  • Vasospasm causes microvascular surgery to fail as a main factor in the loss of transferred flap dye to the diminution of blood flow in reconstruction surgery. Although there has been extensive research to resolve the vasospasm problem, no one has reached an ideal solution to date. However, cryotherapy, which is often used for destruction of tumor lesions, is being presented as a new way of releasing vasospasm. After making a histomorphometric measurement on vasodialation during the course of 1, 3 and 7 days, 2 and 4 weeks, and 5 months periods and observing the change of blood vessel in a histologic, immunohistochemical, and scanning electronic microscopic approach, the results were as follows : 1. Vascular inner diameters of the experimental 1 and 3 days groups were measured $476.3{\pm}28.20{\mu}m$, $497.15{\pm}48.79{\mu}m$ respectively showing statistically meaningful vasodilation(P<0.05), which continued by the experiment 4 weeks group. However, in the experimental 5 months group, the vascular inner diameter appeared similar to the control groups. Even though the thickness of smooth muscular layers come out to be thinner in all the experimental groups compared to the control group, it was difficult to find any statistical meaningfulness. In addition, the vascular external diameters of every experimental groups were shown to be longer than the control group. 2. In light microscopic view, severe injury was evident on the smooth muscular layer cell from the experimental 1 day group, started recovering partially from the experimental 7 days group, and was mostly restored in the experimental 4 weeks group and layer of adventitial stripping were nearly recoverd 2 weeks group. 3. The PCNA positive cells of smooth muscular layer were observed from the experimental 7 days group and had a tendency to increase by the experimental 2 weeks group. In the experimental 4 weeks and 5 months group, the number of PCNA possitive cells observed was comparable to the control group. 4. ${\alpha}$-SMA level of smooth muscular layer cells, having been significantly lower than the control group in the severly damaged experimental 1 day group. It was seen to be increased in the experimental 7 days group and turned out to show similar ${\alpha}$-SMA level in 4 weeks to the control group. 5. In the view of SEM, the endothelial cells were destructed and falling off, and also present the appearance of flattening in the experiment 1 day group. The endothelial layer cells started partially recovering from the 7 days group after the freezing injury. On 4 weeks and 5 months, the endothelial cells were fully coverd the damaged area, also it's appearance is similar to control group. In conclusion, the vascular freezing after the removal of adventitia caused damages to smooth muscular layer cells, and brought about vasodilation, which continued by the 4th week. The smooth muscular layer cells started partially reviving from the 7rd day after the damage by vascular freezing, and recovered their similar figure to the control group's 4 weeks later. This was considered the result of cells which surround the damaged blood vessel being influxed into the smooth muscular layers. Therefore, this local freezing injury on the blood vessel was thought to be applied clinically to relieve severe vasospasm which cannot be treated by vasodilation drug, a microvascular surgery.

  • PDF

Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals (다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상)

  • Jung, Woon-Mo;Sim, Myeong-Heon;Jung, Sang-O;Kim, Min-Yong;Yoon, Chan-Sol;Jung, In-Chol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

Reliable Measurement and Analysis System for Ubiquitous Healthcare (고신뢰 유비쿼터스 헬스케어 데이터 측정 및 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Kim, Jong-Jin;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.293-297
    • /
    • 2009
  • This paper describes a real-time reliable measurement and analysis system for ubiquitous healthcare based on IEEE802.15.4 standard. In order to obtain and monitor physiological body signals continuously, wearable pulse oximeter is designed in wrist that could used to measure oxygen saturation of a patient unobtrusively. The measured data was transferred to a central PC or server by using wireless sensor nodes via a wireless sensor network for storage and analysis purposes. LabVIEW server program was designed to monitor and process the measured photoplethysmogram(PPG) to accelerated plethysmogram(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

  • PDF

Usefulness of 3D Rotational Angiography for Cerebral Vascular Diameter Measurement (뇌혈관 직경측정을 위한 3차원 회전 혈관조영술의 유용성)

  • Seung-Gi, Kim;Sang-Hyun, Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • When measuring cerebrovascular with 3D rotational angiography, the accuracy was verified by comparing the actual size and measurement size, respectively. It is intended to help select therapeutic materials and instruments during cerebrovascular intervention by comparing the average error rates for measured values in the 3DRA and CTA methods by examining with protocols such as brain CTA, which are always performed in emergency situations. The mean error rate between the groups of measurers was ±3.655% for radiation technologist and ±3.331% for university students, and the mean error rate of the student group was within tolerance (±10%), and the independent sample T-test result t =0.879, p=0.394 (p>0.05) showed no statistically difference between the two. In addition, the average error rate measured by both groups by 3DRA was measured below ±5% within the tolerance error rate (±10%), and most of CTA was measured within the tolerance range (±10%), but showed an average error rate of up to 5.65%, and the independent sample T-test result was statistically more accurate than 3DRA. Both the 3DRA method and the brain CTA method for measuring cerebrovascular size could be accurately measured within tolerance, but it would be better to measure cerebrovascular blood vessels using a more accurate 3DRA method during cerebrovascular intervention.

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF

Pulse wave analysis system using wrist type oximeter for u-Health service (u-Health 서비스 지원을 위한 착용형 옥시미터를 이용한 맥파 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • This paper describes a real time reliable monitoring method and analysis system using wrist type oximeter for ubiquitous healthcare service based on IEEE 802.15.4 standard. Photoplethysmograph(PPG) is simple and cost effective technique to measure blood volume change. In order to obtain and monitor physiological body signals continuously, a small size and low power consumption wrist type oximeter is designed for the measurement of oxygen saturation of a patient unobtrusively. The measured data is transferred to a central PC or server computer by using wireless sensor nodes in wireless sensor network for storage and analysis purposes. LabVIEW server program is designed to monitor stress indicator from heart rate variability(HRV) and process the measured PPG to accelerated plethysmograph(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.