• 제목/요약/키워드: Variations

검색결과 13,771건 처리시간 0.046초

생체내 혈중 납 표준물질의 제조 (In Vivo Preperation of Standard Reference Materials of Lead in Blood)

  • 정규철;최호춘
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권4호
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF

한국과 일본에서 유행하는 장염비브리오의 병원성 인자와 유전자의 특성 (Genetic Characteristics and Virulence Factors of Pandemic Vibrio parahaemolyticus Isolated in South Korea and Japan)

  • 홍석원;문지영;이복권;김영부
    • 생명과학회지
    • /
    • 제17권3호통권83호
    • /
    • pp.386-395
    • /
    • 2007
  • 본 연구는 1999년에서 2001년도 걸쳐서 3년간 국내에서 분리된 환자유래 장염비브리오 18균주와 일본 후쿠오카 지역에서 2002년도에 환자에서 분리한 장염비브리오 9균주 등 총 27균주에 대하여 toxR 유전자의 검출, 혈청형별 검사, 약제내성의 양상, tdh, trh1 및 trh2 유전자의 보유상태 및 urease 생성성을 살펴보고, 혈청형 O3:K6 균주에 대하여 TDH의 생성성 검사, tdh 양성균주의 RFLP 형별, ORF 8의 분포, PFGE법과 RAPD법을 실시하였으며 결과는 다음과 같다. 1. 한국 및 일본의 환자유래 균주 대부분에서 urease음성이었으며, toxR 유전자로 확인 동정하였고 혈청형의 분포는 국내 분리 주의 O3:K6, O4:K9, O6:K46, O3:K57, O5:Kl5와 일본 분리주의 O3:K6, O1:K38, O4:K68, O4:Kl2의 혈청형으로 나타났다. 2. 항생제 감수성 시험에서는 vancomycin과 oxacillin은 27균주 (100%), penicillin은 26균주 (96.3%)로 높은 내성을 나타내었고, 14균주 (51.9%)가 4가지 이상의 항생제에 다제내성을 나타내었다. 항생제의 내성양상은 6종류로 혈청형에 관계없이 vancomycin, oxacillin, penicillin에 내성을 나타내는 V형이 15균주 (55.6%)로 가장 많이 나타났다. 3. tdh 유전자는 26균주가 PCR법과 DNA probe hybridization법의 결과에서 양성으로 나타났으며, urease양성이었던 일본 환자유래 혈청형 O3:K6 1균주만이 tdh유전자 음성, trh2 유전자 양성을 나타냈다. 혈청형 O3:K6의 TDH 생성성역가는 전 균주가 256배에서 2,048배 정도로 나타났으며, RFLP 양상은 모든 균주가 11.5 kb와 4.3 kb에 tdh 유전자를 보유하고 있었다. 또한 혈청형 O3:K6 균주들은 RAPD법과 PFGE법으로 유전자형별을 비교 검토한 결과 8형으로 거의동일한 유전자형별의 결과를 나타내었다. 4. ORF 8의 분포는 혈청형 O3:K6 전 균주에서 양성이었고, 특히 혈청형 O6:K46 4균주 모두에서 ORF 8 양성을 나타내어 새롭게 나타난 유행균주일 가능성을 시사 하였다. 따라서 ORF 8 유전자의 검출은 범세계적으로 유행하는 균주들을 동정하는데 있어 genetic marker로서 매우 유용한 것으로 사료된다.

심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성 (Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium)

  • 팽진철;임일한;김기봉;이동수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권4호
    • /
    • pp.285-291
    • /
    • 2008
  • 목적: 심근관류 SPECT에서 자동정량화 소프트웨어를 이용해 관류 및 기능에 대한 객관적이고 재현성 높은 정량 값을 얻을 수 있지만, 이러한 정량값들을 이용할 때는 분절별로 적지 않은 정상변이가 있음을 고려해야 한다. 이 연구에서는 관류에 대한 정량값에서 정상변이를 고려한 새로운 지표들을 유도하고, 이러한 지표들이 임상적 유용성을 가지는지 생존심근 평가를 통해 알아보았다. 대상 및 방법: 심근관류 SPECT에서 관류의 정상변이를 구하기 위해 55명(남:여=28:27)의 관상동맥질환 저확률군을 선정하였다. 이들에게서 $^{201}Tl$ 휴식기/$^{99m}Tc-MIBI$ 부하기 심근관류 SPECT를 실시하고, 20분절 모델을 이용하여 $^{201}Tl$ 휴식기 관류정량값에 대한 각 분절의 평균(m)과 표준편차(SD)를 구하였다. 생존심근 평가를 위해서는 관상 동맥질환을 진단 받고 관상동맥우회로이식술(CABG)을 시행한 환자 48명을 연구대상에 포함하였다. 이들은 수술전 $^{201}Tl$ 휴식기/$^{99m}Tc$-MIBI 부하기 게이트/$^{201}Tl$ 24시간 지연 SPECT을 실시하였고, 수술 3개월 후 추적 게이트 SPECT를 실시하여 생존심근을 판정하였다. 수술 전 $^{201}Tl$ 24시간 지연 SPECT에서 분절별 $Q_{delay}$ (관류정량값), ${\Delta}_{delay}$ ($Q_{delay}$ - m), $Z_{delay}$ (($Q_{delay}$ - m)/SD)가 정의되었고 이들의 생존심근에 대한 진단성적은 수신자특성곡선 상의 곡선하면적(AUC)을 통해 평가하였다. 결과: 관류정량값은 분절 사이에 상당한 변이를 보여, 남자의 경우 최저치 분절에서 $51.8{\pm}6.5$, 최고치 분절에서 $87.0{\pm}5.9$였고, 여성의 경우 최저치 분절 $58.7{\pm}8.1$, 최고치 분절 $87.3{\pm}6.0$으로 나타났다. 생존심근에 대한 진단성능 평가에서 $Q_{delay}$의 AUC는 0.633인데 반해 ${\Delta}_{delay}$$Z_{delay}$의 AUC는 각각 0.735와 0.716으로 나타나 $Q_{delay}$에 비해 유의하게 높은 값을 보였다(각각 p=0.001, 0.018). 가장 높은 AUC를 보인 ${\Delta}_{delay}$는, 최적분리점 -24.7에서 85%의 예민도와 53%의 특이도를 가지는 것으로 나타났다. 결론: 심근관류 SPECT의 자동 정량화 분석에서 관류정량값의 정상변이는 분절에 따라 상당한 것으로 나타났다. 이들을 고려하여 유도된 정량적 지표들은 직접적인 관류정량값에 비해 생존심근 진단에서 더 나은 진단성적을 보였다. 이 연구는 심근관류 SPECT의 정량적 분석에서 정상변이의 고려가 중요함을 시사한다.

PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석 (A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests)

  • 윤선희;김양중;강영직;박수영;김호신;류형기
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

서남극 남 쉐틀랜드 군도 마리안 소만에서 바람 및 강수에 의한 여름철 수층 구조의 변화와 부유물질 분산 (Wind-and Rain-induced Variations of Water Column Structures and Dispersal Pattern of Suspended Particulate Matter (SPM) in Marian Cove, the South Shetland Islands, West Antarctica during the Austral Summer 2000)

  • 유규철;윤호일;오재경;강천윤;김예동;배성호
    • 한국해양학회지:바다
    • /
    • 제8권4호
    • /
    • pp.357-368
    • /
    • 2003
  • 남극 세종기지 앞에 위치한 마리안 소만의 여름 수층 구조과 부유물질 분산기작을 이해하기 위해 빙벽 앞에서 CTDT 연속측정을 하였으며, 측정기간 동안의 조석, 부유물질농도, 유속, 그리고 기상요인도 함께 분석되었다. 45 시간동안 1시간 간격으로 측정된 연속 수층 특성 분포에 의하면, 수심 0∼20 m에는 저온$.$저염$.$고탁도의 혼합 표층수가 존재하였고, 수심 20∼40 m에 고온$.$고염$.$저탁도의 최대수온층인 맥스웰 만 유입수가 나타난다. 그 아래의 수심 40∼70 m에는 주변 해수에 비해 저온$.$고탁도의 아빙하성 유출수인 중층 플름(빙하기저부)이 위치한다. 마지막으로 수심 70 m 이하에 나타나는 저층수는 저온$.$고염$.$저탁도의 특성을 보였다. 늦여름 (2 월초)에 연안의 높아진 설선에서 녹아 소만으로 유입하는 담수의 특성은 유입지역의 특성(지형, 빙하조건, 퇴적물의 구성 등)에 따라 수온과 부유물질농도에서 차이를 보였으며, 바람이 거의 불지 않는 측정시기 동안에는 저염$.$고탁도의 표층 플름이 유입지역에 제한적으로 나타났다. 지속적으로 강한 바람이 불 경우, 빙벽 앞에서 육성기원의 혼탁한 담수성 플름, 저온의 중빙하성 용승수/조수빙하 융빙수 그리고 맥스웰 만 유입수가 혼합되면서 표층에 혼합층(저온$.$저염$.$고탁도)이 발달하였다. 소만의 강수는 단기간 빙하성 유출 증가의 가장 큰 요인이며, 중빙하성 용승수의 발생은 조수빙하의 상태와 강수량이 크게 좌우하였다. 특히 많은 양의 강수로 인해 아빙하성 중층 플름의 유출량이 커지면서 중층 이하의 수심에 저염화를 초래하였다. 그러나 입자가 거의 없을 정도로 깨끗한 중앙 빙벽에서 나오는 중빙하성 용승수와 중층 플름의 유입량이 클지라도, 낮은 부유물질농도로 인해 육성기원 입자의 소만 퇴적율은 작을 것이다.

KODOS-89 지역 망간단괴의 산상 및 분포 특성 (Occurrence and Distribution of Manganese Nodules in KODOS-89 Area, Northeast Pacific)

  • 이경용;문재운
    • 한국해양학회지
    • /
    • 제27권3호
    • /
    • pp.210-227
    • /
    • 1992
  • 태평양 클라리온, 클리퍼톤 균열대내 북서단에 위치해 있는 KODOS-89 지역에 분포 하는 망간단괴의 형태 및 화학적 성실은 해저지형에 따라 상이하다. 해저평원 지역은 토도로카이트/버나다이트 및 Mn/Fe 비가 크며, 망간, 구리, 니켈, 아연의 함량이 높 고, 철 및 코발트의 함량이 낮은 산화성 속성기원의 단괴가 지배적이며, 해저지역은 속성기원과 상반된 구성 광물 및 금속 함량을 갖는 수성기원의 단괴로 대표된다. 속성 기원의 단괴는 결정질 산화광물의 침전이 퇴적물내에서 이루어지기 때문에 거칠은 표 면조직(r-형)을 가지며, 단괴의 크기가 증가함에 따라 구형, 타구형, 쟁반형의 외형으 로 변모한다. 이에 비하여, 수성기원의 단괴는 해수로부터 미정질 산화광물이 흡착되 므로 매끈한 표면조직(s형)을 가지며, 다단괴형 또는 불규칙형의 외형으로 특징된다. 망간단괴의 분포밀도는 해저산 지역이 평균 13.3 kg/m$^2$로 높으며, 해저평원 지역은 평균 3.9 kg/m$^2$로 낮지만 고위로 지역에 비해 저위로 지역이 높다. 이러한 망간단괴 의 분포밀도 변화는 일차적으로는 씨앗효과에 의해 이차적으로는 위도에 따른 퇴적물 내 유기물 함량 차이에 의해 비롯되었다고 생각된다. 즉, 해져산 지역은 수성작용에 의한 단괴의 성장으로 기존의 단괴가 잘 쪼개지므로서 씨앗효과가 증대하여 분포밀도 가 높다. 해저평원 지역중 남부 지역은 주변에 해저산이 많이 분포되어 있어 핵물질의 공급이 용이하며, 이와 더불어 적도 고생산대로부터 원할한 유기물 공급으로 속성작용 이 촉진되어 북부 지역에 비해 높은 분포밀도를 갖는다. 화산응회암과 현무암이 흔재되어 있으면서 자성이 낮은 것으로 알 려져 있는 L-2층에 대비할 수 있다.화학 적 역할을 규명하는데 중요하게 이용될 것으로 판단된다.TEX>반찬젓갈${\lrcorner}$의 유리아미노산은 ${\ulcorner}$일본병조림젓갈${\lrcorner}$의 약 2배이다. 5) 아미노산 전체양에 점유하는 글루타민산은 ${\ulcorner}$일본병조림젓갈${\lrcorner}$이 45.5%, ${\ulcorner}$반찬젓갈${\lrcorner}$이 29.2%이다. 6) 주체적 아미노산은 ${\ulcorner}$시장젓갈${\lrcorner}$에는 글루타민산, leucine, alanine, lysine의 4종류, ${\ulcorner}$반찬젓갈${\lrcorner}$에는 글루타민산, leucine, alanine의 3종류, ${\ulcorner}$일본병조림젓갈${\lrcorner}$은 글루타민산이 현저하게 많다.회하였다.ollowed fro all Sullungtang samples from Hanwoo. The results showed that the overall quality of Sullungtang significantly decreased as the parity increased for Hanwoo cows. The Sullungtang extracted

  • PDF

탄소 및 질소안정동위원소 조성에 의한 남해안 진동만 양식 미더덕의 먹이원 평가 (Food Sources of the Ascidian Styela clava Cultured in Suspension in Jindong Bay of Korea as Determined by C and N Stable Isotopes)

  • 문창호;박현제;윤성규;곽정현
    • 한국해양학회지:바다
    • /
    • 제19권4호
    • /
    • pp.302-307
    • /
    • 2014
  • 2008년 4월에서 2009년 1월 사이에 진동만 미더덕의 섭식 생태를 설명하기 위하여 $20{\mu}m$ 이상(coarse particulate organic matter, CPOM) 그리고 $0.7{\mu}m$ 이상 $20{\mu}m$ 이하(fine POM)의 크기가 나누어진 각각의 부유입자유기물과 미더덕에 대한 ${\delta}^{13}C$${\delta}^{15}N$ 값의 월별 변동을 비교 분석하였다. CPOM과 FPOM의 ${\delta}^{13}C$${\delta}^{15}N$을 월별로 비교한 결과 전체적으로 CPOM(평균 $-18.5{\pm}1.2$‰, $9.3{\pm}0.7$‰)이 FPOM(평균 $-20.5{\pm}1.5$‰, $8.4{\pm}0.5$‰)에 비해 유의하게 높은 값을 나타내었다. 미더덕의 ${\delta}^{13}C$${\delta}^{15}N$ 값은 각각 평균 $-18.9({\pm}1.7)$‰과 $11.6({\pm}0.7)$‰로 나타났는데, 이와 같은 비값들은 CPOM 보다는 FPOM의 월별 변동과 비슷한 경향을 보여 이들이 CPOM에 비하여 상대적으로 FPOM에 더 높은 영양 의존도를 가진다는 것을 강하게 시사해 주었다. 그러나 미더덕의 먹이원으로서 CPOM과 FPOM의 상대적인 중요성은 시기에 따른 각 요소의 가용성(availability)에 크게 의존하는 것으로 나타났는데, 이와 같은 결과는 부유입자물질의 크기에 관계없이 미더덕에 의한 비선택적 먹이 섭식을 잘 반영하는 듯 하였다. 본 연구 결과는 미더덕의 지속적인 양식생산을 유지하기 위해 가용 먹이원으로서 식물플랑크톤과 함께 미소 부유입자유기물의 유용성을 고려해야함을 잘 나타내 주었다.

이어도 해양과학기지 관측 파고와 인공위성 관측 유의파고 차이의 특성 연구 (2004~2016) (Characteristics of the Differences between Significant Wave Height at Ieodo Ocean Research Station and Satellite Altimeter-measured Data over a Decade (2004~2016))

  • 우혜진;박경애;변도성;이주영;이은일
    • 한국해양학회지:바다
    • /
    • 제23권1호
    • /
    • pp.1-19
    • /
    • 2018
  • 이어도 해양과학기지 유의파고 자료와 인공위성(GFO, Jason-1, Envisat, Jason-2, Cryosat-2, SARAL) 고도계 유의파고 자료를 비교하기 위하여 2004년 12월부터 2016년 5월까지 약 12년 동안의 위성-이어도 관측 유의파고 사이의 일치점 데이터베이스를 생산하였다. 위성 유의파고는 이어도 해양과학기지 유의파고에 대하여 약 0.34 m의 평균 제곱근 오차와 0.17 m의 양의 편차를 나타내었다. 위성과 이어도 관측 유의파고 차는 특이한 계절변동이나 경년변동을 보이지 않고 위성이 중복 관측하는 기간에 대해서 유사한 변동 특성을 보여 위성 자료의 일관성을 확인할 수 있었다. 위성-이어도 유의파고 차이에 대한 바람장의 영향을 조사한 결과 모든 위성에 대해 평균적으로 0.17 m 정도의 양의 편차가 나타났다. 지형 및 해양과학기지 구조물의 영향을 파악하기 위하여 파향에 대한 파고 오차의 특이성을 분석하였으나 통계적으로 유의미한 특성이 나타나지 않았다. 위성-이어도 일치점의 거리에 따른 영향을 조사하기 위하여 위성-이어도 간의 거리에 대한 함수로 오차의 특성을 분석한 결과 평균은 거리와 무관하게 0.14 m로 거의 일정하게 유지되는 반면에 오차의 최댓값과 최솟값 사이의 진폭은 이어도로부터 멀어질수록 선형적으로 증가하는 특성이 발견되었다. 반면에 동해 해양기상위성부이를 활용한 위성 유의파고 자료의 정확도 평가 결과, 위성-실측 자료 사이의 평균 제곱근 오차는 0.27 m로 상대적으로 작은 오차가 발생하였으며, 이어도 파고 자료와 같이 특이한 오차 특성은 발견되지 않았다. 이어도 파고 관측 기기의 상이성을 고려하여 이 연구에서는 위성 유의파고 자료를 기반으로 이어도 유의파고 자료를 보정하는 식을 제안하였다. 또한 이어도 해양과학기지가 국제적인 해양관측 기지로 격상되기 위해서는 자료의 신뢰도 확보가 우선되어야 함을 강조하고 방법과 전략을 제시하였다.

편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구 (A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method)

  • 이석기;안규동;이병국
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.59-67
    • /
    • 1995
  • 현재 국내에서 원자흡광법에 의한 혈중연 분석은 분석선 283.3 nm에서의 $D_2$ 보정 방식을 이용한 흑연로 원자흡광법이 주로 이용되고 있으며, 일반적인 시료중 납에 관한 분석은 217.0 nm에서의 $D_2$ 보정 방식이 보편화되어 있다. 그러나 이들 방식은 바탕 보정에 제한성 때문에 새로운 바탕 보정법에 대해 관심을 가지게 되었다. 그러던 중 1980년대 말부터 혈중연 분석자들은 연 분석에 있어 Zeeman effect 보정방식이 보다 좋은 결과를 나타낸다 하여 이 방법에 대하여 관심을 갖게 되었다. 따라서 본 연구는 국내 대부분의 혈중연 분석기관들이 보유하고 있는 $D_2$ 보정방식 (217.0과 283.3 nm)의 혈중연 측정결과를 편광 Zeeman effect 보정방식의 측정 결과와 비교함으로서 현재 사용 중인 기기 들의 측정결과의 타당성을 검토하기 위하여 시도하였으며 다음과 같은 결과를 얻었다. Zeeman형의 바탕보정 방식을 사용하는 기기의 결과를 편의상 1.00으로 하고, $D_2$ 형 보정 장치의 217.0 nm와 283.3 nm에서의 결과를 짝비교 (paired t-test)를 하였을 때 혈중연 농도가 $20.0{\mu}g/dl$ 이하인 경우에 0.92와 0.90으로 Zeeman형보다 낮은 값으로 분석되었으며 통계적으로 유의하였다.(P<0.001). $20.1-40.0{\mu}g/dl$인 군에서는 $D_2$ 보정방식의 결과간에 차이는 없었다. Zeeman 및 $D_2$ 보정방법에서는 혈중연 증가에 따른 바탕보정장치의 변동이 적었고 혈중연 이외의 다른 금속 즉, 철, 구리, 아연에서는 바탕보정장치에 관계없이 철은 역상관인 것으로 나타났으며, 구리와 아연은 정상관을 갖는 것으로 나타났다. 연구 결과로 미루어보아 두방법간의 차이가 없으므로 혈중연 분석에 있어서 Zeeman형 바탕보정 장치를 사용하거나 $D_2$ 바탕보정 방식(217.0, 283.3nm)의 기기를 사용하여도 무난할 것으로 생각된다.

  • PDF

가을철 차광 처리에 따른 진달래와 영산홍의 생리적 반응 (Physiological Responses of Rhododendron mucronulatum and R. indicum with Shading Treatment in Autumn Season)

  • 이경재;송기선;정영숙;윤택승;홍성권;김재현;이상우;김종진
    • 원예과학기술지
    • /
    • 제28권3호
    • /
    • pp.403-408
    • /
    • 2010
  • 본 실험은 비닐온실 내에서 0%, 35%, 55%, 75% 차광처리에 따른 진달래($Rhododendron$ $mucronulatum$ Turcz.)와 영산홍($R.$ $indicum$ (L.) Sweet) 묘목의 생리적 반응을 조사하기 위하여 수행되었다. 차광처리는 생육 후반기인 2008년 9월 9일부터 11월 5일까지 시행되었다. 차광처리는 9월의 낮 온도를 0.9-$1.7^{\circ}C$, 10월에는 0.8-$1.7^{\circ}C$ 정도를 낮추는 효과가 관측되었다. 차광처리 전 진달래 및 영산홍의 함수율은 각각 68.5%, 66.3%이었으며, 차광처리 기간 후 75% 차광 하의 진달래의 함수율은 66.2%로써 3.4%가 감소하였으며, 영산홍은 65.9%로써 0.6%가 감소하였다. 두 수종 모두 차광 수준이 높아질수록 감소율이 낮아지는 유사한 경향을 보였다. 영산홍의 광합성능력은 차광 수준이 높아질수록 높았는데 75% 차광에서 $9.63{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$로 가장 높았다. 한편, 세포간극 내 $CO_2$의 농도, 기공전도도 및 증산율 역시 전광 하의 묘목에 비하여 차광처리에 따라 높았는데 55%, 35% 및 75% 차광순이었다. 수분이용효율은 전광의 묘목이 차광처리 묘목에 비하여 상대적으로 높은 것으로 조사되었다. 차광처리를 받지 않은 진달래 잎색은 자주색에 가까운 색으로 변색한 반면, 차광처리 수준이 높을수록 육안으로도 녹색이 지속되고 있는 것이 관찰되었다. 이러한 차광 수준별 진달래 잎색의 변화를 Munsell Color Chart로 정리한 결과 전광의 경우 R(red)과 Y(yellow) chart의 색이 많은 반면 차광 수준이 높을수록 G(green), Y의 chart에 속하는 비율이 높아 여전히 녹색을 많이 띄고 있었다.