• 제목/요약/키워드: Variation Part

검색결과 1,559건 처리시간 0.039초

AT LEAST TWO SOLUTIONS FOR THE SEMILINEAR BIHARMONIC BOUNDARY VALUE PROBLEM

  • Jung, Tacksun;Choiy, Q-Heung
    • Korean Journal of Mathematics
    • /
    • 제22권4호
    • /
    • pp.633-644
    • /
    • 2014
  • We get one theorem that there exists a unique solution for the fourth order semilinear elliptic Dirichlet boundary value problem when the number 0 and the coefficient of the semilinear part belong to the same open interval made by two successive eigenvalues of the fourth order elliptic eigenvalue problem. We prove this result by the contraction mapping principle. We also get another theorem that there exist at least two solutions when there exist n eigenvalues of the fourth order elliptic eigenvalue problem between the coefficient of the semilinear part and the number 0. We prove this result by the critical point theory and the variation of linking method.

A Combined Process Control Procedure by Monitoring and Repeated Adjustment

  • Park, Changsoon
    • Communications for Statistical Applications and Methods
    • /
    • 제7권3호
    • /
    • pp.773-788
    • /
    • 2000
  • Statistical process control (SPC) and engineering process control (EPC) are based on different strategies for processes quality improvement. SPC reduces process variability by detecting and eliminating special causes of process variation. while EPC reduces process variability by adjusting compensatory variables to keep the quality variable close to target. Recently there has been needs for a process control proceduce which combines the tow strategies. This paper considers a combined scheme which simultaneously applies SPC and EPC techniques to reduce the variation of a process. The process model under consideration is an integrated moving average(IMA) process with a step shift. The EPC part of the scheme adjusts the process back to target at every fixed monitoring intervals, which is referred to a repeated adjustment scheme. The SPC part of the scheme uses an exponentially weighted moving average(EWMA) of observed deviation from target to detect special causes. A Markov chain model is developed to relate the scheme's expected cost per unit time to the design parameters of he combined control scheme. The expected cost per unit time is composed of off-target cost, adjustment cost, monitoring cost, and false alarm cost.

  • PDF

인천시 위생매립지 쓰레기 조성 및 침출수 특성에 관한 연구 (A Study on Composition of Municipal Solid Wastes and Characteristics of Leachate in In-Cheon Sanitary Landifil Site)

  • 박석환;정문식
    • 한국환경보건학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 1992
  • This study was performed to investigate the seasonal variation of the composition of domestic solid wastes and the characteristics of the leachate sampled in In-Cheon sanitary landfill site. The results were as follows 1. Combustible part was larger than incombustible part of the domestic solid wastes in spring and sumer. 2. The food waste was major source of solid wastes in In-Cheon city as 36.5%, and its variation by seasons was negligible. 3. BOD of the leachate was in the range of 853~7, 350mg/l, and fluctuated by seasons. 4. The mean of COD$_{cr}$ Was 5, 044mg/l, the mean of COD$_{Mn}$ was 2, 212mg/l. Namely, the method by $K_{2}Cr_{2}O_{7}$ was more sensitive than the method by KMnO$_{4}$. 5. TOC was in the range of 773~3, 958mg/l, it was lower than BOD.

  • PDF

영구동토 지대에서 Thermal Siphon의 효율성 연구 (An Study on Efficiency and Application of Thermal Siphon in the Permafrost)

  • 강재모;김학승
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

各種 燐化合物溶媒 抽出系에 있어서 4f 및 5f 系列 元素의 抽出速度 및 分配率의 溫度依存性 (Extraction Rate and Temperature Dependency of Distribution Ratio of 4f and 5f Series Element in the Various Phosphorus Compounds)

  • 이진택
    • 대한화학회지
    • /
    • 제13권3호
    • /
    • pp.199-204
    • /
    • 1969
  • 4f 및 5f 系列 元素의 溶媒抽出에 있어서 分配速度를 測定해 본 結果 4f 系列의 前半部와 後半部 間에 明白한 差異를 볼 수 있었다. 三價의 Am 및 Cm은 4f 系列의 前半部와 類似함을 알았다. 또한 分配率과 抽出溫度와의 關係를 檢討해 본 結果 抽出系에 따라 獨特한 增加 또는 減少傾向이 나타났으며 또한 Chelate 抽出系에 있어서는 原子番號 存在性이 있음을 알았다

  • PDF

Temperature-time analysis for steel structures under fire conditions

  • Wong, M.B.;Ghojel, J.I.;Crozier, D.A.
    • Structural Engineering and Mechanics
    • /
    • 제6권3호
    • /
    • pp.275-289
    • /
    • 1998
  • The objective of the paper is to present a method whereby the time required for a steel structure to sustain the effects of a prescribed temperature rise according to real fire curves can be calculated. The method is divided into two parts. The first part deals with the post-yield behaviour of steel structures at elevated temperatures. It takes into account the variation of the properties of steel material with temperature in an incremental elastoplastic analysis so that the safety factor of the structure under certain fire conditions can be assessed. The second part deals with the heat transfer problem of bare steel members in real fire. Factors affecting the heat transfer process are examined and a model for predicting the temperature variation with time under real fire conditions is proposed. This model results in more accurate temperature predictions for steel members than those obtained from previously adopted model.

조립식 아이스하버식 어도의 현장 적용을 위한 수리모형실험 (Hydraulic Model Experiment for Field Application of Iceharbor-type Precast Fishway)

  • 김재옥;박상현;조재원;황종서;조국현;조성주
    • 한국농공학회논문집
    • /
    • 제46권2호
    • /
    • pp.3-14
    • /
    • 2004
  • This study was conducted to assess the possibility of the field application of the iceharbor-type precast fishway. When overflow depth of weir is 4.0 cm in model fishway, upper part velocities appear appropriate for upstream migration of fish and the lowest overflow wall (right line) in lower part has shown velocity distribution more or less inadequate for upstream migration. Except that right line, left and middle line revealed that velocities are appropriate for upstream migration of fish. Therefore, we concluded that this fishway owing to be not broad growth width of overflow velocities according to increasing discharges can correspond to variation of water level. Also We consider that various velocities in fishway were effective, because slow velocity line can guide flow for upstream migration. For low flow, the arrangement of different crest level or each overflow part (higher left, middle and lower right, or lower left, middle and higher right) was more effactive than unform crert level. Hole plays an important role as migration pass during drought and flood flow. Therefore, We concluded that this fishway can cope with water depth variation by various overflow wall height change and raise the field applicability with better performance hydraulically and structurally.

회전브러시가 장착된 진공청소기 흡입장치의 난류유동에 대한 수치해석 (NUMERICAL STUDY OF TURBULENT FLOW IN A INTAKE PART OF VACUUM CLEANER WITH ROLLING BRUSH)

  • 박태선
    • 한국전산유체공학회지
    • /
    • 제17권2호
    • /
    • pp.58-64
    • /
    • 2012
  • Turbulent flows in a intake part of vacuum cleaner are studied by RANS simulations. The governing equations are solved by the SIMPLE algorithm based on the finite volume method of the unstructured grid system. The predicted results show that the suction performance is closely related to the variation of flow structure in the intake part. In order to investigate for the cleaning of bedclothes and carpet without sticking, several design changes are applied. The introduction of a solid cylinder in the intake part changes vortical structures significantly. Based on this result, a new design with spiral brushes is proposed. The design shows a good behavior for the suction performance and the flow control.