• Title/Summary/Keyword: Variance of Analysis

Search Result 6,248, Processing Time 0.035 seconds

Fractal dimension from radiographs of bone as indicators of possible osteoporosis (골다공증의 표식자로서 방사선학적 fracrtal dimension의 유용성에 관한 연구)

  • LEE Keon-Il
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.17-26
    • /
    • 1998
  • The purpose of this study was to investigate whether a radiographic estimate of osseous fractal dimension is useful in the characterization of structural changes in bone. Ten specimens of bone were progressively decalcified in fresh 50 ml solutions of 0.1 N hydrochloric acid solution at cummulative timed periods of 5, 10, 20, 30, 60 and 90 minutes, and radiographed from 0 degree projection angle controlled by intraoral parelleling device. The test set of 70 radiographs was digitized and digitally filtered to reduce film -grain noise. I performed one-dimensional variance and fractal analysis of bony profiles or scan lines. Correlation analysis quantified the relationship between variance and fractal dimension. The obtained results were as follow. 1. After the first stage of decalcification variance and fractal dimension of scan line pixel intensities generally decreased with a range of 57.94 to 12.64 and 1.59 to 1.36. 2. Correlation coefficient(r) relating variances to fractal dimensions was consistantly excellent(range r=0.90 to 0.98). 3. Variance and fractal dimension were much alike in ability to discriminate, at leat on a group basis, between control and decalcified specimens.

  • PDF

Power Algorithms for Analysis of Variance Tests

  • Hur, Seong-Pil
    • Journal of the military operations research society of Korea
    • /
    • v.13 no.1
    • /
    • pp.45-64
    • /
    • 1987
  • Power algorithms for analysis of variance tests are presented. In experimental design of operational tests and evaluations the selection of design parameters so as to attain an experiment with desired power is a difficult and important problem. An interactive computer program is presented which uses the power algorithms for ANOVA tests and creates graphical presentations which can be used to assist decision makers in statistical design. ANOVA tests and associated parameters (such as sample size, types and levels of treatments, and alpha-level)are examined.

  • PDF

Relationship between Perception for Appraisal of Perioperative Nurses and Performance and Organizational Commitment (수술실 간호사의 성과 평가에 대한 인식이 조직몰입 및 성과에 미치는 영향)

  • Kang, Kyoung-Hee;Park, Sung-Ae
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.17 no.2
    • /
    • pp.189-197
    • /
    • 2011
  • Purpose: This study was an analysis of the relationship between perception for appraisal of staff nurses in operating rooms and performance and organizational commitment. Method: The survey was conducted with 176 staff nurses in operating rooms in 2 hospitals in Seoul. Data were analyzed using frequency, one-way ANOVA, Pearson correlation analysis, and stepwise multiple regression. Result: 1. Perception for appraisal including accuracy and justice was significantly related to organizational commitment (r=.496, P=.000). Perception for appraisal including accuracy and justice was slightly related to performance (r=.220, P=.003). 2. In order to determine the percentage of the variance of performance and organizational commitment that could be predicted by perception for appraisal, perception for appraisal was entered in the regression equation. Accuracy accounted for 25% of the variance in the organizational commitment. To determine the percentage of the variance of performance that could be predicted by perception for appraisal and organizational commitment, the perception for appraisal and organizational commitment were entered in the regression equation. Organizational commitment accounted for 21% of the variance in the performance. Consequently accuracy predicted organizational commitment. Organizational commitment predicted performance. Conclusions: Findings indicate the need to increase accuracy of performance appraisal to promote organizational commitment and performance in perioperative nurses.

Factors Affecting Patient Moving for Medical Service Using Multi-level Analysis (환자이동에 영향을 미치는 개인 및 병원요인 분석)

  • Kim, Sun Hee;Lee, Hae Jong;Lee, Kwang Soo;Shin, Hyun Woung
    • Korea Journal of Hospital Management
    • /
    • v.19 no.4
    • /
    • pp.9-20
    • /
    • 2014
  • The purpose of this study is to find out factors affecting patient moving to receive medical service. This study is analyzed by multi-level model with patient and hospital level by using SAS 9.3. Total number of patients is 600,000 persons for inpatients and 550,000 patients for outpatients. The degree of the factors, which is combined with personnel factor and hospital factor, can be analyzed by Intra-Class Correlation (ICC). The percentage of group(hospital) level variance of the total variance for out-bound moving case are 30.6% at inpatients, and 28.3% at outpatients. And the percentage of hospital level variance of the total variance for moving distance, are 26.7%, 32,5% respectively. Conclusionally, although the main factor of moving is patient level, hospital is also very important factor to make decision to go out-bound. It contributed to about 1/3 for hospital choice. And, when the one make decision, he will consider the hospital type, number of bed, and training institute in hospital level. Through this study to find out hospital factors affecting patient moving for medical service, it must be continued to find out which factors have more influence to choice the hospital among disease type after this.

  • PDF

Analysis on the spread variance by the spill-over spot on the spark sonance

  • Kim, Jeong-lae;Hwang, Kyu-sung
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.237-242
    • /
    • 2019
  • Spark variance technique is melded the jagged spill-over-sonance status of the glitter-differentiation knowledge level (GDKL) on the spark knowledge gestalt. The knowledge level condition by the spark knowledge gestalt system is comprised with the spill-over-sonance system. As to search a spot of the glitter situation, we are obtained of the spark value with black-red dot by the spill-over upper structure. The concept of knowledge level is comprised the reference of glitter-differentiation level for variance signal by the spark sonance gestalt. Further presenting a jagged variance of the GDKL of the maximum in terms of the spill-over-sonance gestalt, and spark spot sonance that was the a spark value of the far variance of the Spa-kg-FA-${\rho}_{MAXN}$ with $17.68{\pm}2.22units$, that was the a spark value of the convenient variance of the Spa-kg-CO-${\rho}_{MAXN}$ with $7.55{\pm}0.59units$, that was the a spark value of the flank variance of the Spa-kg-FL-${\rho}_{MAX}$ with $2.70{\pm}0.48units$, that was the a spark value of the vicinage variance of the Spa-kg-VI-${\rho}_{MAX}$ with $0.48{\pm}0.05units$. The spill-over sonance will be to appraisal at the jagged ability of the spill-over-sonance gestalt with black-red dot by the spark knowledge level on the GDKL that is presented the glitter-differentiation gestalt by the knowledge level system. Spill-over knowledge system will be possible to restrain of a gestalt by the special signal and to employ a spark data of spill-over sonance level.

BER Analysis of a Quadrature Receiver with an Autocalibration Function (자동보정 기능을 가진 Quadrature 수신기의 BER 해석)

  • Kwon, Soon-Man;Lee, Jong-Moo;Cheon, Jong-Min;Park, Min-Kook;Kim, Jong-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.457-459
    • /
    • 2005
  • In this paper the BER consideration of a quadrature receiver that has an autocalibration method is considered. The analysis is based on the derivation of the statistical characteristics of the imbalances in gain and phase between in-phase and quadrature components that may cause severe performance degradation of the receiver. The density. mean and variance functions of the estimates of gain and phase imbalances are discussed. Then it is shown that the estimates are asymptotically minimum variance unbiased with respect to the integration time in sampling. A brief consideration on the BER calculation follows.

  • PDF

A STUDY ON THE EFFECT OF POWER TRANSFORMATION IN SPATIAL STATISTIC ANALYSIS

  • LEE JIN-HEE;SHIN KEY-IL
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.3
    • /
    • pp.173-183
    • /
    • 2005
  • The Box-Cox power transformation is generally used for variance stabilization. Recently, Shin and Kang (2001) showed, under the Box-Cox transformation, invariant properties to the original model under the large mean and relatively small variance assumptions in time series analysis. In this paper we obtain some invariant properties in spatial statistics. Spatial statistics, Invariant Property, Variogram, Box-Cox power Transformation.

Quantitative Analysis of Bayesian SPECT Reconstruction : Effects of Using Higher-Order Gibbs Priors

  • S. J. Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.133-142
    • /
    • 1998
  • In Bayesian SPECT reconstruction, the incorporation of elaborate forms of priors can lead to improved quantitative performance in various statistical terms, such as bias and variance. In particular, the use of higher-order smoothing priors, such as the thin-plate prior, is known to exhibit improved bias behavior compared to the conventional smoothing priors such as the membrane prior. However, the bias advantage of the higher-order priors is effective only when the hyperparameters involved in the reconstruction algorithm are properly chosen. In this work, we further investigate the quantitative performance of the two representative smoothing priors-the thin plate and the membrane-by observing the behavior of the associated hyperparameters of the prior distributions. In our experiments we use Monte Carlo noise trials to calculate bias and variance of reconstruction estimates, and compare the performance of ML-EM estimates to that of regularized EM using both membrane and thin-plate priors, and also to that of filtered backprojection, where the membrane and thin plate models become simple apodizing filters of specified form. We finally show that the use of higher-order models yields excellent "robustness" in quantitative performance by demonstrating that the thin plate leads to very low bias error over a large range of hyperparameters, while keeping a reasonable variance. variance.

  • PDF

A Study on Addiction Toward Luxury Product (명품 중독(名品 中毒)에 관(關)한 연구(硏究))

  • Lee, Seung-Hee
    • Journal of Fashion Business
    • /
    • v.10 no.4
    • /
    • pp.140-150
    • /
    • 2006
  • The purpose of this study was to examine affecting the addictive buying behavior toward fashion luxury products. 227 female college students were who purchased fashion luxury products surveyed for this study. For data analysis, descriptive statistics, factor analysis, and multiple regression were used. As the results, addictive buying toward luxury products was classified into three factors: impulse addictive, money addictive, and psychological addictive. Also, consumers' individuality pursuit was classified into four factors: unique choice, non-similarity choice, individual choice and non-social interest. Multiple regression results revealed that impulse buying, stress, and unique choice accounted for 38% of the explained variance in addictive buying toward luxury products. Also, regression results indicated that impulse buying, stress, unique choice and reference group accounted for 38% of the explained variance in impulse addictive buying. Finally, regression results pointed out that unique choice and impulse accounted 24% of the explained variance in psychological addictive buying. Based on these results, fashion social responsibility marketing strategies would be suggested.

Comparison of Storage Lifetimes by Variance Assumption using Accelerated Degradation Test Data (파괴적 가속열화시험 데이터의 분산가정에 따른 수명비교)

  • Kim, Jonggyu;Back, Seungjun;Son, Youngkap;Park, Sanghyun;Lee, Moonho;Kang, Insik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.173-179
    • /
    • 2018
  • Estimating reliability of a non-repairable system using the degradation data, variance assumption such as homogeneity (constant) or heteroscedasticity (time-variant) could affect accuracy of reliability estimation. This paper showed reliability estimation and comparison results under normal conditions using accelerated degradation data obtained from destructive measurements, according to variance assumption of the data at each measurement time. Degradation data from three accelerated conditions with stress factors of temperature and humidity were used to estimate reliability. The $B_{10}$ lifetime was estimated as 1243.8 years by constant variance assumption, and 18.9 years by time-variant variance. And variance assumption provided different analysis results of important stresses to reliability. Thus, accurate assumption of variance at each measurement time is required when estimating reliability using degradation data of a non-repairable system.