• Title/Summary/Keyword: Variance of Analysis

Search Result 6,248, Processing Time 0.037 seconds

CBCT-based assessment of root canal treatment using micro-CT reference images

  • Lamira, Alessando;Mazzi-Chaves, Jardel Francisco;Nicolielo, Laura Ferreira Pinheiro;Leoni, Graziela Bianchi;Silva-Sousa, Alice Correa;Silva-Sousa, Yara Terezinha Correa;Pauwels, Ruben;Buls, Nico;Jacobs, Reinhilde;Sousa-Neto, Manoel Damiao
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.245-258
    • /
    • 2022
  • Purpose: This study compared the root canal anatomy between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) images before and after biomechanical preparation and root canal filling. Materials and Methods: Isthmus-containing mesial roots of mandibular molars(n=14) were scanned by micro-CT and 3 CBCT devices: 3D Accuitomo 170 (ACC), NewTom 5G (N5G) and NewTom VGi evo (NEVO). Two calibrated observers evaluated the images for 2-dimensional quantitative parameters, the presence of debris or root perforation, and filling quality in the root canal and isthmus. The kappa coefficient, analysis of variance, and the Tukey test were used for statistical analyses(α=5%). Results: Substantial intra-observer agreement (κ=0.63) was found between micro-CT and ACC, N5G, and NEVO. Debris detection was difficult using ACC (42.9%), N5G (40.0%), and NEVO (40%), with no agreement between micro-CT and ACC, N5G, and NEVO (0.05<κ<0.12). After biomechanical preparation, 2.4%-4.8% of CBCT images showed root perforation that was absent on micro-CT. The 2D parameters showed satisfactory reproducibility between micro-CT and ACC, N5G, and NEVO (intraclass correlation coefficient: 0.60-0.73). Partially filled isthmuses were observed in 2.9% of the ACC images, 8.8% of the N5G and NEVO images, and 26.5% of the micro-CT images, with no agreement between micro-CT and ACC, and poor agreement between micro-CT and N5G and NEVO. Excellent agreement was found for area, perimeter, and the major and minor diameters, while the roundness measures were satisfactory. Conclusion: CBCT images aided in isthmus detection and classification, but did not allow their classification after biomechanical preparation and root canal filling.

A STUDY ON THE EFFECT OF DENTIN BONDING AGENTS APPLIED OVER ENAMEL ABOUT THE BOND STRENGTH OF COMPOSITE RESIN (접착강화제가 치아경조직과의 접착강도 변화에 미치는 영향에 관한 연구)

  • Choi, Woong-Dae;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 1995
  • The purpose of this study was to investigate the effect of dentin bonding agents on the bond strength of composite resin restorations in case of applying the dentin bonding agents to acid etched enamel surfaces. Freshly extracted 364 bovine anterior teeth were selected as a adherents. 320 enamel specimens were divided into two groups(unetched group (1) and etched group (2) for testing the shear bond strength, 40 specimens were used for the hardness testing, and 4 specimens of rest were to observe the resin-tag formation into etched enamel surfaces. All surfaces of enamel specimens were polished with 320~1500 SiC paper under continuous running water. In Group (1), 100 enamel specimens were polished and unetched. 220 polished enamel specimens in Group (2) were etched with 37 % phosphoric acid solution for 60 seconds, washed with water for 20 seconds, and dried with a light air pressure for 60 seconds. Three kinds of dentin bonding agents(Gluma, Prisma, Scotchbond 2) were evaluated the effect on the bond strength to conditioned enamel surfaces. Shear bond strengths were measured on the three cases such as a coating of primer only, a coating of sealer only, and a sequential coating of primer and sealer to acid etched enamel surfaces were compared with the bond strengths measured by the coating of enamel bonding agent followed by the bonding of composite resin (Photo clearfil bright, Kuraray, Japan) to unetched and acid etched enamel surfaces. In addition, the hardness tested on the adhesive fractured surface between composite resin enamel as a mean of evaluation of a factor whether the mechanical bond strengths were affected and the penetration of dentin bonding agents into etched enamel surfaces was also observed. Bond strengths were measured using the method of shear bond strength by a universal testing machine (Instron-4467, USA), statistical test were applied to the results using a one way analysis variance(ANOVA), and hardness was measured by the Vicker's Hardness Tester(MHT-i, Matsuzawa, Japan) and the penetration of the resins were observed by the SEM (Hitachi, S-2300, Japan). The following conclusions were drawn; 1. Enamel bonding agent showed to affect the improvement of bond strength of composite resin to enamel surface both unetched and etched. 2. Dentin bonding agents could be resulted in increase of bond strength to unetched enamel surface, but there were no statistical significances. 3. Bond strengths to etched enamel surface were significantly decreased with a coating of dentin primer only. 4. Coating of sealer only and coating of primer and sealer noticed the similar bond strengths of composite resin to etched enamel using the enamel bonding agents. 5. The applying method proved to be more effective than the kinds of dentin bonding agents on the bond strength of composite resin to etched enamel than the kind of dentin. 6. Vicker's hardness numbers of dentin bonding agents were lower than that of composite resin, but the degree of penetration of dentin bonding agents into etched enamel surfaces was excellent.

  • PDF

Analysis of Nursing Studies of Coping Conducted in Korea from 1978 to 1995 (대처 개념의 국내 간호연구 분석)

  • 소향숙;조복희;홍미순
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.3
    • /
    • pp.709-729
    • /
    • 1996
  • This study was done to analyze the trends of research on coping in Korea, to suggest future direction, for research on coping, and ultimately to contribute to an increase in explanation of adaptation. This article reviewed 79 nursing research papers on coping done since 1978 by examining them according to the period of publication or presentation, research design, type of subjects, measurement instruments, research for a degree or not, range of reliability, and association of coping and related variables. The results are as follows : The number of studies on coping increased rapidly from the mid-1980's and decreased slowly from the mid-1990's. The maority of the studies were surveys, comparative studies, or correlational studies. The subects of the 46 studies were healthy people, while those in the remaining studies were patients with a variety of illnesses. Thirth-eight studies on coping were done for master's thesis, three for dissertion, and 38 were not degrees. The Bell and Jalowiec coping scales have not been used since the early 1990's. In contrast, Lazarus and Folkman's W.C.C.L. has been used increasingly since that time. The reliabilities of the coping scale were reported in 37 cases and the Cronbach's alpha coefficients were .71 to .86. All subjects reported using more problem-oriented coping than emotion-oriented coping in short-term or emotion-oriented coping and healthy groups did more long-term coping. It was difficult to describe consistently the relationship between stress and coping according to the type of coping scale or research subjects, but generally moderate relationships were found. This was due to instrumental problems and no consideration of situational context. The subject group who used more short-term coping and less long-term coping reported poorer mental status, and higher scores in burnout and state anxiey than others. That is, the relationship between stress and adaptation increased the power of explanation with intervening the mediating effect of coping. The association of locus of control, mastery, social support, and self-concept with coping showed positive relationships : those of uncertainty and severity in illness with coping showed negativerelationships ; those of state anxiety and depression with short-term coping were positive, and those of self-esteem with long-term coping or problem-oriented coping were negative. There were significant differences in the scores of types of coping according to religion, level of education, and socio-economic status. That is, Presbyterians and Catholics, those with higher education levels and higher socio-economic status used more long-term or problem-oriented coping. On the basis of the above findings the following recommendations are made : 1. There is a need to test the mediating effect of coping variable in order to clarify the concept. 2. Longitudinal studies are needed to determine the patterns of change in coping strategies when stressful events are encountered. 3. It's necessary to develop a reliable and variable measurement tool for coping. 4. There is a need to identify subscales of coping to increase explanation of variance 5. It's necessary to consider personal, situational, and antecedent variables : the characteristics of subject populations, the natures of illness and treatment situations. 6. The power of explanation of studies designed to identify the stress-adaptation process should be increased using the combination model of process-oriented coping and cognitive-structural model.

  • PDF

Association Between Body Mass Index and Cognitive Function in Mild Cognitive Impairment Regardless of APOE ε4 Status

  • Ye Sol Mun;Hee Kyung Park;Jihee Kim;Jiyoung Yeom;Geon Ha Kim;Min Young Chun;Hye Ah Lee;Soo Jin Yoon;Kyung Won Park;Eun-Joo Kim;Bora Yoon;Jae-Won Jang;Jin Yong Hong;Seong Hye Choi;Jee Hyang Jeong
    • Dementia and Neurocognitive Disorders
    • /
    • v.21 no.1
    • /
    • pp.30-41
    • /
    • 2022
  • Background and Purpose: In this study we aimed to find the association between neuropsychological performance and body mass index (BMI) in patients with mild cognitive impairment (MCI). In addition, we investigated the effects of the apolipoprotein E (APOE) genotype in the relationship between the BMI and cognition in MCI. Methods: We enrolled a cohort of 3,038 subjects with MCI aged 65-90 from the Clinical Research Center for Dementia of South Korea and a dementia cohort of the Ewha Womans University Mokdong Hospital. MCI patients were classified into three subgroups according to the Asian standard of BMI. We compared cognitive performances between groups by one-way analysis of variance. To investigate the effects of the APOE genotype, we used multivariate linear regression models after adjusting for possible confounders. Results: Even though normal BMI groups were younger, had more females, and had less comorbidities, the higher BMI groups had better cognitive functions. Among subjects with APOE ε4 carriers, there was a positive relationship between the BMI and the memory task alone. Conclusions: Our findings suggested that higher BMI in patients with MCI were associated with better cognitive performance. The effects of the APOE ε4 genotype in the associations between BMI and cognition were distinguishing. Therefore, according to physical status, APOE ε4 genotype-specific strategies in the assessments and treatments may be necessary in elderly patients with MCI.

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

A Study on the Residents' Perception about New Towns of Seoul Metropolitan Area (수도권 신도시에 대한 주민의 인식 평가 연구)

  • Yoon, Jeong-Joong;Yoon, Jeong-Ran
    • Journal of the Korean Regional Science Association
    • /
    • v.35 no.3
    • /
    • pp.45-58
    • /
    • 2019
  • The government is recently pushing for five large-scale public housing sites near Seoul, the so-called third wave of new towns. In this regard, this study sought to analyze the key considerations in planning new towns from the perspective of the residents who are the consumers, using survey data. For this purpose, frequency analysis and variance analysis(ANOVA) were conducted on existing first and second era of new towns and the third era of new towns scheduled for construction. Eight indicators, such as environmental comfort, self-sufficiency such as jobs, transportation access and convenience, were set as subordinate variables, and characteristics of residents, including gender, age, number of households, household income, occupation, and residential areas, were set as explanatory variables. According to the analysis, the respondents rated the first era of new towns more positively than the second era of new towns. For self-sufficiency items such as jobs, both the first and second era of new towns showed low levels. In addition, for the eight indicators, the first era of new towns were no significant differences depending on gender, number of households, or household income, and the second era of new towns were no significant differences by the number of households, household income, occupations or place of residence. However, for new towns in the third period, the assessment of the importance of each indicator by age, number of households, household income and occupation showed significant differences. The results of the multi-comparison analysis of the third era of new towns showed that the importance of environmental comfort was highly valued by the youth, the managerial/professional/clerical position, single or five more persons of household, and the youth, high income household, the managerial/professional/clerical position when it comes to accessibility and convenience of transportation. It suggests that various personal characteristics and demands for each of the planning indicators need to be considered in planning for the third era of new towns.

Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD) (전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가)

  • Lee, Joo-Ah;Back, Geum-Mun;Kim, Yeon-Soo;Son, Soon-Yong;Choi, Kwan-Woo;Yoo, Beong-Gyu;Jeong, Hoi-Woun;Jung, Jae-Hong;Kim, Ki-Won;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.125-134
    • /
    • 2014
  • This study is to provide basic information regarding photoneutron doses in terms of radiation treatment techniques and the number of portals in intensity-modulated radiation therapy (IMRT) by measuring the photoneutron doses. Subjects of experiment were 10 patients who were diagnosed with prostate cancer and have received radiation treatment for 5 months from September 2013 to January 2014 in the department of radiation oncology in S hospital located in Seoul. Thus, radiation treatment plans were created for 3-Dimensional Conformal Radiotherapy (3D-CRT), Volumetric-Modulated Arc Radiotherapy (VMAT), IMRT 5, 7, and 9 portals. The average difference of photoneutron dose was compared through descriptive statistics and variance analysis, and analyzed influence factors through correlation analysis and regression analysis. In summarized results, 3D-CRT showed the lowest average photoneutron dose, while IMRT caused the highest dose with statistically significance (p <.01). The photoneutron dose by number of portals of IMRT was $4.37{\pm}1.08mSv$ in average and statistically showed very significant difference among the number of portals (p <.01). Number of portals and photoneutron dose are shown that the correlation coefficient is 0.570, highly statistically significant positive correlation (p <.01). As a result of the linear regression analysis of number of portals and photoneutron dose, it showed that photoneutron dose significantly increased by 0.373 times in average as the number of portals increased by 1 stage. In conclusion, this study can be expected to be used as a quantitative basic data to select an appropriate IMRT plans regarding photoneutron dose in radiation treatment for prostate cancer.

Models for Estimating Genetic Parameters of Milk Production Traits Using Random Regression Models in Korean Holstein Cattle

  • Cho, C.I.;Alam, M.;Choi, T.J.;Choy, Y.H.;Choi, J.G.;Lee, S.S.;Cho, K.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.5
    • /
    • pp.607-614
    • /
    • 2016
  • The objectives of the study were to estimate genetic parameters for milk production traits of Holstein cattle using random regression models (RRMs), and to compare the goodness of fit of various RRMs with homogeneous and heterogeneous residual variances. A total of 126,980 test-day milk production records of the first parity Holstein cows between 2007 and 2014 from the Dairy Cattle Improvement Center of National Agricultural Cooperative Federation in South Korea were used. These records included milk yield (MILK), fat yield (FAT), protein yield (PROT), and solids-not-fat yield (SNF). The statistical models included random effects of genetic and permanent environments using Legendre polynomials (LP) of the third to fifth order (L3-L5), fixed effects of herd-test day, year-season at calving, and a fixed regression for the test-day record (third to fifth order). The residual variances in the models were either homogeneous (HOM) or heterogeneous (15 classes, HET15; 60 classes, HET60). A total of nine models (3 orders of $polynomials{\times}3$ types of residual variance) including L3-HOM, L3-HET15, L3-HET60, L4-HOM, L4-HET15, L4-HET60, L5-HOM, L5-HET15, and L5-HET60 were compared using Akaike information criteria (AIC) and/or Schwarz Bayesian information criteria (BIC) statistics to identify the model(s) of best fit for their respective traits. The lowest BIC value was observed for the models L5-HET15 (MILK; PROT; SNF) and L4-HET15 (FAT), which fit the best. In general, the BIC values of HET15 models for a particular polynomial order was lower than that of the HET60 model in most cases. This implies that the orders of LP and types of residual variances affect the goodness of models. Also, the heterogeneity of residual variances should be considered for the test-day analysis. The heritability estimates of from the best fitted models ranged from 0.08 to 0.15 for MILK, 0.06 to 0.14 for FAT, 0.08 to 0.12 for PROT, and 0.07 to 0.13 for SNF according to days in milk of first lactation. Genetic variances for studied traits tended to decrease during the earlier stages of lactation, which were followed by increases in the middle and decreases further at the end of lactation. With regards to the fitness of the models and the differential genetic parameters across the lactation stages, we could estimate genetic parameters more accurately from RRMs than from lactation models. Therefore, we suggest using RRMs in place of lactation models to make national dairy cattle genetic evaluations for milk production traits in Korea.

Bioequivalence of Boryung Torsemide Tablet to Torem Tablet (Torasemide 10 mg) by High Performance Liquid Chromatography/UV Detector

  • Cho, Hea-Young;Kang, Hyun-Ah;Park, Chan-Ho;Kim, Se-Mi;Kim, Dong-Ho;Park, Sun-Ae;Kim, Kyung-Ran;Hur, Hyeon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two torasemide tablets, Torem tablet (Roche Korea Co., Ltd., Korea, reference drug) and Boryung Torsemide tablet (Boryung Pharmaceutical Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (furosemide) to human serum, serum samples were extracted using 5 mL of ethyl acetate. Compounds were analyzed by reverse-phase HPLC method with UV detection. This method showed linear response over the concentration range of 0.05 ug/mL with correlation coefficient of 0.999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ug/mL which was sensitive enough for pharmacokinetic studies. Twenty-eight healthy male Korean volunteers received each medicine at the torasemide dose of 20 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of torasemide were monitored by an HPLC-UV for over a period of 12 hr after the administration. $AUC_{t}$(the area under the serum concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum serum drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{t}$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_{t}$ ratio and the $C_{max}$ ratio for Boryung Torsemide/Torem were log 0.97-10g 1.03 and log 0.93log 1.12, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Boryung Torsemide tablet and Torem tablet are bioequivalent.

MECHANICAL PROPERTIES OF LASER-WELDED CAST TITANIUM AND TITANIUM ALLOY (원심 주조된 타이타늄과 타이타늄 합금의 레이저 용접 특성)

  • Yun, Mi-Kyung;Kim, Hyun-Seung;Yang, Hong-So;Vang, Mong-Sook;Park, Sang-Won;Park, Ha-Ok;Lee, Kwang-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.642-653
    • /
    • 2006
  • Purpose : The purpose of this study was to investigate the effect of the output energy(voltage) of laser welding on the strength and properties of joint of cast titanium(CP Gr II) and titanium alloy(Ti-6Al-4V). Material and method : Cast titanium and its alloy rods(ISO6871) were prepared and perpendicularly cut at the center of the rod. After the cut halves were fixed in a jig, and the joints welded with a laser-welding machine at several levels of output voltage of $200V{\sim}280V$. Uncut specimens served as the non-welded control specimens The pulse duration and pulse spot size employed in this study were 10ms and 1.0mm respectively. Tensile testing was conducted at a crosshead speed of 0.5mm/min. The ultimate tensile strength(MPa) was recorded, and the data (n=6) were statistically analyzed by one-way analysis of variance(ANOVA) and Scheffe's test at ${\alpha}$=0.05. The fracture surface of specimens investigated by scanning electron microscope (SEM). Vickers microhardness was measured under 500g load of 15seconds with the optimal condition of output voltage 280V. Results : The results of this study were obtained as follows, 1. When the pulse duration and spot size were fixed at 10ms and 1.0mm respectively, increasing the output energy(voltage) increased UTS values and penetration depth of laser welded to titanium and titanium alloy. 2. For the commercial titanium grade II, ultimate tensile strength(665.3MPa) of the specimens laser-welded at voltage of 280V were not statistically(p>0.05) different from the non-welded control specimens (680.2MPa). 3. For the titanium alloy(Ti-6Al-4V), ultimate tensile strength(988.3MPa) of the specimens laser-welded at voltage of 280V were statistically(p<0.05) different from the non-welded control specimens (665.0MPa). 4. The commercial titanium grade II and titanium alloy(Ti-6Al-4V) were Vickers microhardness values were increased in the fusion zone and there were no significant differences in base metal, heat-affected zone.