• Title/Summary/Keyword: Variable Output

Search Result 1,174, Processing Time 0.029 seconds

Studies on the Hemodynamic Changes in Cirrhosis of the Liver (간경변증(肝硬變症)에서의 혈역학적(血力學的) 변화(變化)에 관(關)한 연구(硏究))

  • Kim, Jung-Il;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.2
    • /
    • pp.11-27
    • /
    • 1970
  • Cardiac output, plasma volume and renal plasma flow were determined to evaluate hemodynamic changes in 29 patients with cirrhosis of the liver. The results obtained were as follows. 1. The mean plasma volume was 3793+895ml and it was significantly higher than the normal controls. The mean blood volume ($5266{\pm}1222ml$) and blood volume per kg body weight ($95.7{\pm}23.41ml$) were also increased significantly. The mean plasma volume per kg body weight ($69.1{\pm}19.1ml$) showed increased tendency and the mean difference between blood volume and plasma volume per kg body weight ($26.4{\pm}7.05ml$) was in lower limit of normal range. 2. The mean cardiac output was $7708{\pm}2652ml/min$ and it was significantly increased. The mean cardiac index ($4924{\pm}1998ml/min/M^2$), stroke volume ($96.2{\pm}34.2ml/beat$), stroke index ($62.3{\pm}27.34ml/M^2$) and fractional cardiac index ($1.54{\pm}0.577$) were also increased significantly. The mean total -peripheral resistance was $1664{\pm}753.8\;dynes\;sec\;cm^{-5}M^2$ and it was significantly lower than the normal controls. 3. The mean renal plasma flow was $537{\pm}146.8ml/min/1.73M^2$ and it was normal to decreased tendency. The mean endogenous creatinine clearance ($66.7{\pm}23.0ml/min/1.73M^2$) was significantly decreased. Filtration fraction was variable, but it was slightly lower than normal in most cases. The mean renal fraction of cardiac output ($11.4{\pm}6.27%$) was relatively decreased. 4. Although renal plasma flow was normal or decreased in general, it was definitely diminished in patients with creatinine clearance less than $60ml/min/1.73M^2$, resistant ascites, and signs of azotemia (elevated BUN and serum creatinine). 5. Diminished glomrular filtration rate with low filtration fraction and decreased renal fraction of cardiac output observed strongly supported increased renal afferent arteriolar resistance. 6. Renal circulatory impairment preceded azotemia or oroliguria in cirrhosis. 7. Clinical findigns and liver function were not correlated with hemodynamic changes, except for esophageal varices associated with high cardiac output obsedved. 8. No definite correlation of renal hemodynamics with plasma volume or cardiac output was found.

  • PDF

Analysis of Signal Integrity of High Speed Serial Interface for Ultra High Definition Video Pattern Control Signal Generator (UHD급 영상패턴 제어 신호발생기를 위한 고속 시리얼 인터페이스의 신호 무결성 분석)

  • Son, Hui-Bae;Kweon, Oh-Keun
    • Journal of Broadcast Engineering
    • /
    • v.19 no.5
    • /
    • pp.726-735
    • /
    • 2014
  • In accordance with 4K UHD(Ultra High Definition) LCD television's higher resolution and data expansion, LCD TV had to face problems such as increasing numbers of cables and tangible skews problems among cables. The V-by-One HS is a new interface technology in the path between the image processing IC and timing control (TCON) board. The variable speed from 600 Mbps to 3.75 Gbps effectively meets the requirements of various different pixel rates. In this paper, we use the V-by-One HS interface to illustrate our proposed simulation method of frequency resonance mode and PCB design approach to model the effects of signal integrity for high speed video signal using an IBIS models.

A Study on the Phase-looked Dielectric Resonator Oscillator using Bias Tuning (바이어스 동조를 이용한 위상 고정 유전체 공진 발진기에 관한 연구)

  • 류근관;이두한;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1982-1990
    • /
    • 1994
  • We implemented a PLDRO(Phase Locked Dielectric Resonator Oscillator) using the concept of the feedback property of PLL(Phase Locked Loop) for Ku-band(10.95-11.70 GHz). The conventional approaches to a PLDRO design use varactor diode tuning method.. But in theis paper, the PLDRO has the advantage of the frequency sensitivity to changes in the supple voltage of the oscillating device without the frequency-variable part by varactor diode voltage-control. and uses a SPD(Sampling Phase Detector) for phase-comparision. The PLDRO is composed of the DRO phase-locked to the reference signal of UHF band by using a SPD for high frequency stability and can be available for European FSS(Fixed Satellite Service) at 10.00GHz. The PLDRO generates the output power of 8.67 dBm at 10.00 GHz and has a phase noise of -81 dBc/Hz at 10 kHz offset from carrier. The hamonic and spurious characteristics have -42.33 dBc and -65dBc respectively. This PLDRO has much better frequency stability, lower phase noise, and more economical effect for a satellite system than conventional DRO.

  • PDF

A Design and Construction of Phase-locked Dielectric Resonator Oscillator for VSAT (VSAT용 위상고정 유전체 공진 발진기의 설계 및 구현)

  • 류근관;이두한;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1973-1981
    • /
    • 1994
  • A PLDRO(Phase Locked Dielectric Resonator Oscillator) in Ku-band(10.95-11.70GHz) is designed with the concept of the feedback property of PLL(Phase Locked Loop). A series feedback type DRO is developed, and VCDRO(Voltage Controlled Dielectric Resonator Oscillator) using a varactor diode as a voltage-variable capacitor is implemented to tune oscillating frequency electrically. Then, PLDRO is designed by using a SPD(Sampling Phase Detector). This PLDRO is phase-locked voltage controlled DRO to reference source(VHF band) by SPD at 10.00 GHz for European FSS(Fixed Satellite Service). The PLDRO generates output power greater than 10dBm at 10.00 GHz and has phase noise of -80 dBc/Hz at 10 KHz offset from carrier. This PLDRO achieves much better frequency stability than conventional VCDRO.

  • PDF

Design of Digital PWM Controller for Voltage Source Inverter (전압형 인버터를 위한 디지털 PWM 제어기 설계)

  • 이성백;이종규;정구철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.3
    • /
    • pp.27-33
    • /
    • 1993
  • This paper presents the &tal controller for driving high frequency voltage fed PWM inverter that carrier frequency is over 2OkHz.We analyzed the conventional PWM to select a proper PWM pattern. as the result, obtained PWM pattern of the controller in which asynchronus staircase sinusoidal waveform is used as reference signal, and variable carrier ratio method was used for PWM control. The PWM controller is designed by fully digital method. Especially, Thk proposed controller is consisted of 8 bit one-chip microprocessor and digital logic. the former is for arithmetic and data processing, and the latter is for PWM pattern synthesis. Therefore, The responsibility and controllability is improved. Also, Data processing capability is improved using proper program to output modulation index with 9 bits. Circuits configuration of digital controller are made up of one chip 8051 and EPLD, and its controllability is tested by operating voltage fed inverter. Harmonics and current waveform is evaluated and analyzed for the voltage fed inverter system.

  • PDF

A Nonlinear Sliding Mode Controller for IPMSM Drives with an Adaptive Gain Tuning Rule

  • Jung, Jin-Woo;Dang, Dong Quang;Vu, Nga Thi-Thuy;Justo, Jackson John;Do, Ton Duc;Choi, Han Ho;Kim, Tae Heoung
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.753-762
    • /
    • 2015
  • This paper presents a nonlinear sliding mode control (SMC) scheme with a variable damping ratio for interior permanent magnet synchronous motors (IPMSMs). First, a nonlinear sliding surface whose parameters change continuously with time is designed. Actually, the proposed SMC has the ability to reduce the settling time without an overshoot by giving a low damping ratio at the initial time and a high damping ratio as the output reaches the desired setpoint. At the same time, it enables a fast convergence in finite time and eliminates the singularity problem with the upper bound of an uncertain term, which cannot be measured in practice, by using a simple adaptation law. To improve the efficiency of a system in the constant torque region, the control system incorporates the maximum torque per ampere (MTPA) algorithm. The stability of the nonlinear sliding surface is guaranteed by Lyapunov stability theory. Moreover, a simple sliding mode observer is used to estimate the load torque and system uncertainties. The effectiveness of the proposed nonlinear SMC scheme is verified using comparative experimental results of the linear SMC scheme when the speed reference and load torque change under system uncertainties. From these experimental results, the proposed nonlinear SMC method reveals a faster transient response, smaller steady-state speed error, and less sensitivity to system uncertainties than the linear SMC method.

Selecting the Batters of National Baseball Squad using Data Envelopment Analysis (DEA를 이용한 야구 국가대표단의 타자 선발에 관한 연구)

  • Suk, Yeung-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.165-172
    • /
    • 2014
  • The purpose of this paper is to identify whether the national baseball squad made up of the best players may get the outstanding results in the international competitions or not. Using Data Envelopment Analysis, the relative efficiency of players in Korean Baseball Organization is estimated as performance measure, and compared with the efficiency scores of national squad members. The paper focuses on the proper choice of DEA model in a baseball setting, thereby selecting the BCC model with non-discretionary variable. Two input variables(plate appearances and stolen bases to enforce) and three output variables(runs, on-base plus slugging and stolen base percentage) are used to evaluate the efficiency of the baseball players. Results showed that 22 players among 97 players were classified as efficient and 8 players among 12 national squad members were as efficient. These findings indicate a potential for DEA to be a major part of the analytical approaches in evaluating the relative efficiency of players.

Study on Following of Parmeter ${\alpha}$ of 2-DOF PID Controller Using Fuzzy Algorithm

  • Lee, Sang-Min;Cho, Yong-Sung;Park, Jong-Oh;Choo, Yeon-Gyu;Lim, Young-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.307-311
    • /
    • 2003
  • 2-mass system is generally used as controller of the variable-speed to transfer electromotion power to mechanical load such as industrial robot, driving parts of electric vehicle, rolling machine system of steel plant and driving parts of elevator. In this case, PI controller is often used as a velocity controller because of simplicity of system. But PI control algorithm is not enough for obtaining the control characteristics required for this system. To solve this problem, 2-mass system based on the PID controller derives the optimum PID parameters by pole assignment and estimation of the ITAE performance index. In this case, the system have tenacious properties about disturbance, but it causes extreme overshoot and vibration because of rapidly output of controller in early transient response about desired value. And if speed control system is applied by 2-DOF parameter ${\alpha}$, a temporary value, we must induce most suitable parameter by complicate pole assignment and estimation of the ITAE performance index whenever ${\alpha}$ changes. In this paper, to solve this problem we suggest control algorithm to followed exactly value of ${\alpha}$ as 2-DOF parameter by using fuzzy algorithm . So, intelligence algorithm modeled by human knowledge, experience, teachability and judgment follow exact ${\alpha}$ value and it can compose the efficient 2-DOF PID controller to improve following performance, overshoot decrease.

  • PDF

Efficient Partitioning of Matched Filter for Long Pulse in Active Sonar Application (능동 소나에서 시간적으로 긴 펄스에 대한 정합 필터의 효율적인 분할 기법)

  • Shin, Donghoon;Kim, Jin Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.262-267
    • /
    • 2014
  • Recently, long pulses are transmitted for target detection in active sonar application. Matched filtering implemented by simple convolution algorithm, requires massive computational power for long replica. The computational loads are reduced significantly by implementing the convolution in the frequency domain with overlap add method, but the performance degrades for specified input/output system delay which constrains the size of FFT function. For performance improvement, the replica could be partitioned into uniform blocks (FDL) by re-using IFFT operations, or variable blocks of increasing length (MC) by using the largest possible blocks to calculate the convolution. In this paper, by combining the strong points of the two methods, we propose a new filter partition structure that allows for further optimization of the previous two methods.

DC-DC Converter for Low-Power Power Management IC (저-전력 전력 관리 회로를 위한 DC-DC 변환기)

  • Jeon, Hyeondeok;Yun, Beomsu;Choi, Joongho
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.174-179
    • /
    • 2018
  • In this paper, design of high-efficiency DC-DC converter is presented for low-power PMIC (power management integrated circuit). As PMIC technologies for IoT and wearable devices have been continuously improved, high-efficiency energy harvesting schemes should be essential. Since the supply voltage resulting from energy harvesting is low and widely variable, design techniques to achieve high efficiency over a wide input voltage range are required. To obtain a constant switching frequency for wide input voltage range, frequency compensation circuit using supply-voltage variation sensing circuit is included. In order to obtain high efficiency performance at very low-power condition, accurate burst-mode control circuit was adopted to control switching operations. In the proposed DC-DC buck converter, output voltage is set to be 0.9V at the input voltage of 0.95~3.3V and maximum measured efficiency is up to 78% for the load current of 180uA.