• Title/Summary/Keyword: Vapor tube

Search Result 315, Processing Time 0.024 seconds

Laminar Film Condensation Model of Pure Steam in a Vertical Tube (수직관 내 순수 증기의 층류 액막 응축 모델)

  • Kim, Dong Eok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.33-40
    • /
    • 2014
  • In this study, a new model for calculating the liquid film thickness and condensation heat transfer coefficient in a vertical condenser tube is proposed by considering the effects of gravity, liquid viscosity, and vapor flow in the core region of the flow. In order to introduce the radial velocity profile in the liquid film, the liquid film flow was regarded to be in Couette flow dragged by the interfacial velocity at the liquid-vapor interface. For the calculation of the interfacial velocity, an empirical power-law velocity profile had been introduced. The resulting liquid film thickness and heat transfer coefficient obtained from the proposed model were compared with the experimental data from other experimental study and the results obtained from the other condensation models. In conclusion, the proposed model physically explained the liquid film thinning effect by the vapor shear flow and predicted the condensation heat transfer coefficient from experiments reasonably well.

A Pulse Power Supply for a Metal Vapor Laser Using IGBTs (IGBT를 사용한 금속증기레이저용 펄스 전원)

  • 진정태;차병헌;김철중;이흥호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.415-419
    • /
    • 2004
  • A pulse power supply using IGBTs and MPC (magnetic pulse compression) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a vacuum tube or thyratron type pulse power supply. A series-connected IGBT array generated a long pulse of its pulse width 2 ${\mu}\textrm{s}$ md then it was compressed to less than 100 ns by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 10 mm inner diameter and 0.5 m discharge length. and successfully operated.

Flow Visualization of Oscillation Characteristics of Liquid and Vapor Flow in the Oscillating Capillary Tube Heat Pipe

  • Kim, Jong-Soo;Kim, Ju-Won;Jung, Hyun-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1507-1519
    • /
    • 2003
  • The two-phase flow patterns for both non-loop and loop type oscillating capillary tube heat pipes (OCHPs) were presented in this study. The detailed flow patterns were recorded by a high-speed digital camera for each experimental condition to understand exactly the operation mechanism of the OCHP. The design and operation conditions of the OCHP such as turn number, working fluid, and heat flux were varied. The experimental results showed that the representative flow pattern in the evaporating section of the OCHP was the oscillation of liquid slugs and vapor plugs based on the generation and growth of bubbles by nucleate boiling. As the oscillation of liquid slugs and vapor plugs was very speedy, the flow pattern changed from the capillary slug flow to a pseudo slug flow near the annular flow. The flow of short vapor-liquid slug-train units was the flow pattern in the adiabatic section. In the condensing section, it was the oscillation of liquid slugs and vapor plugs and the circulation of working fluid. The oscillation flow in the loop type OCHP was more active than that in the non-loop type OCHP due to the circulation of working fluid in the OCHP. When the turn number of the OCHP was increased, the oscillation and circulation of working fluid was more active as well as forming the oscillation wave of long liquid slugs and vapor plugs in the OCHP. The oscillation flow of R-142b as the working fluid was more active than that of ethanol and the high efficiency of the heat transfer performance of R -142b was achieved.

Prediction of Service Life of a Respirator Cartridge for Organic Solvent by Using Yoon and Nelson's Adsorption Model (Yoon과 Nelson의 흡착모델을 이용한 방독마스크 정화통의 수명예측(I))

  • Kim, Ki-Hwan;Won, Jung-Il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.20-31
    • /
    • 2008
  • A respirator is useful to protect a worker from the harmful gases and vapors in the workplace, and the evaluation of respirator cartridge service life is important for the worker's health and safety. The performance of cartridge is effected by several factors such as concentration of gas and vapor, humidity, temperature, adsorbents and cartridge packing density. Adsorption model was applied to both sampling tube and respirator cartridge to predict the service life for organic vapors. The variables of the adsorption model were measured from the experiment with the sampling tube, and it was used to predict the service life of respirator cartridge. In the experiment, we used carbon tetrachloride as a organic vapor and activated carbon take out respirator cartridge as activated carbon. As a result, it was possible to predict the service life of respirator cartridge and predicted service life was quite correct. Breakthrough time decreased with increase of CCl4 concentration. In case of sampling tube, adsorbed amount of CCl4 was larger than respirator cartridge due to linear velocity. Also, rate constant of sampling tube was larger than respirator cartridge, because of, effect of flow rate, packing density. In the prediction of service life of respirator cartridge by using sampling tube, the time required for 50% contaminant breakthrough(${\tau}$) is more effective than the rate constant(k').

Condensation Heat Transfer for the R-11 Superheated Vapor with and without Noncondensable Gas (R-11의 응축열전달에 미치는 부응축가스 및 과열의 영향)

  • CHO Kwon-Ok;KUM Jong-Soo;OH HOO-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.85-93
    • /
    • 1985
  • An experimental investigation on condensing heat transfer for the Refrigerant-11 superheated vapor during condensation on the 40 mm O.D by 75 mm long horizontal tube is carried out under the various conditions of air contents as noncondensable gas, condensing pressure, and coolant temperature. The data span a refrigerant flow range from 23 to 63 kg/h and weight fractions of noncondensable gas range from 0 to $15\%$. The comparisons are made using data obtained by the authors and further data obtained from other sources. The characteristics of the condensing heat transfer of refrigerant superheated vapor with and without noncondensable gas flowing horizontally are revealed experimentally, and on the basis of the data obtained, correlations for predicting heat transfer coefficient during condensation on the tube are proposed.

  • PDF

Mass production of carbon nanotubes using Vapor Phase Growth (기상합성법을 이용한 탄소나노튜브의 대량합성)

  • 류승철;이태재;이철진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.123-126
    • /
    • 2001
  • Multiwalled carbon nanotubes were massively produced by the catalytic reaction of C$_2$H$_2$ - Fe(CO)$\sub$5/ mixture at 750 - 950$^{\circ}C$ in a quartz tube reactor and over quartz substrates. Well-aligned MWNT array grows perpendicular to the quartz tube reactor and the quartz substrates at an average of 60 nm in diameter and up to several thousands of micrometers in length. This method does not require any pretreatment of substrates and CNTs are grown at atmospheric pressure. It could be suitable for mass production of multiwalled nanotubes. Scanning electron microscope and transmission electron microscope images of the nanotubes deposited on the substrates allowed us to monitor the quality of MWNTs grown under different operating conditions.

  • PDF

Effects of Non-absorbable Gases in the Absorption of Water Vapor by Aqueous LiBr Solution Film on Horizontal Tube Banks

  • Kwon, Ky-Seok;Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.19-27
    • /
    • 2001
  • In the present study, the effects of film Reynolds number (60∼200) and volumetric content of non-absorbable gases (0∼10%) in water vapor on the absorption process of aqueous LiBr solution were investigated experimentally. The formation of solution film on the horizontal tubes of six rows was observed to be complete for Re>100. Transition film Reynolds number was found to exist above which the Nusselt number and Schmidt number diminishes with solution flow rate. As the concentration of non-absorbable gases increased, mass transfer rate decreased more seriously than heat transfer rate did. the degradation effects of non-absorbable gases seemed to be significant especially when small amount of non-absorbable gases was introduced to the pure water vapor.

  • PDF

An Experimental Study of the Modified Chemical Vapor Deposition Process -Temperature Distribution and Particle Deposition Measurements- (수정된 화학증착(MCVD)에 관한 실험적 연구 - 온도분포와 입자부착 측정)

  • 조재걸;최만수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3057-3065
    • /
    • 1994
  • An experimental study has been made for heat transfer and particle deposition during the Modified Chemical Vapor Deposition process which is currently utilized to manufacture high quality optical waveguides. The distributions of tube wall temperatures, rates and efficiencies of particle deposition were measured. Results indicate that the temperature distributions of the tube wall in the axial direction yield the quasi-steady form in which temperature distributions fit in one curve if the relative distance from the moving torch is used as an axial coordinate. Due to the repeated heatings from the traversing torch, the wall temperatures are shown to reach the minimum ahead of torch and it is shown that the two torch formulation suggested by Park and Choi is valid to predict this minimum temperature. Measured wall temperatures, particle deposition efficiencies and tapered entry length are compared with the previous modelling results and shown to be in agreement.

Effects of Inner Jet Injection on Particle Deposition in the Annular Modified Chemical Vapor Deposition Process Using Concentric Tubes (환상형원관을 사용하는 수정된 화학증착(MCVD)방법에서 내부 제트분사가 입자부착에 미치는 영향)

  • 최만수;박경순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.212-222
    • /
    • 1994
  • In the annular Modified Chemical Vapor Deposition process using two concentric tubes, the inner tube is heated to maintain high temperature gradients to have high thermophoretic force which can increase particle deposition efficiency. However, higher axial velocity in a narrow gap between inner and outer tubes can result in a longer tapered entry length. In the present paper, a new concept using an annular jet from the inner tube is presented and shown to significantly reduce the tapered entry length with maintaining high efficiency. Effects of a jet injection on heat transfer, fluid flow and particle deposition have been studied. Of particular interests are the effects of jet velocity, jet location and temperature on the deposition efficiency and tapered length . Torch heating effects from both the previous and present passes are included and the effect of surface radiation between inner and outer tubes is also considered.

Robust Design for Shape Parameters of High Pressure Thermal Vapor Compressor by Numerical Analysis (전산해석을 통한 고압열증기압축기 형상변수에 관한 강건 설계)

  • Park, Il-Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.12
    • /
    • pp.931-937
    • /
    • 2008
  • A high motive pressure thermal vapor compressor(TVC) for a commercial multi-effect desalination(MED) plant is designed to have a high entraining performance and its robustness is also considered in the respect of operating stability at the abrupt change of the operating pressures like the motive and suction steam pressure which can be easily fluctuated by the external disturbance. The TVC having a good entraining performance of more than entrainment ratio 6.0 is designed through the iterative CFD analysis for the various primary nozzle diameter, mixing tube diameter and mixing tube length. And then for a couple of TVC having a similar entrainment ratio, the changes of the entrainment ratio are checked along the motive and suction pressure change. The system stability is diagnosed through the analyzing the changing pattern of the entrainment ratio.