• 제목/요약/키워드: Vapor passage

검색결과 16건 처리시간 0.028초

스크린 메쉬를 이용한 판형 히트 파이프의 개발 (Development of Flat Plate Heat Pipe Using Screen Meshes)

  • 이용덕;홍영호;김현태;김구영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1506-1511
    • /
    • 2003
  • The present study proposes a new structure for a flat plate heat pipe which could embody a thin thickness, any shapes and high heat density a unit area. It is on the structure for the formation of vapor passages and the support of the case of the flat plate heat pipe. A screen mesh is used as the one. To verify the validity of the one, the flat plate heat pipe of 1.08mm thickness was made with a layer of the screen mesh with 14 and 100 mesh number respectively and tested. Here the screen mesh with 14 mesh number plays a role of the vapor passage and the support of the case and the screen mesh with 100 mesh number functions as the wick structure. T he results show that the screen mesh excellently carries out the function of the vapor passage and the support of the case.

  • PDF

히트 스프레더의 열전달 성능에 관한 연구 (A Study on the Heat Transfer Performance of a Heat Spreader)

  • 김현태;이용덕;오민정;장성욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1258-1263
    • /
    • 2004
  • The present study proposes a new structure for a heat spreader which could embody a thin thickness, any shapes and high heat flux per unit area. It is on the structure for the formation of vapor passages and the support of the case of the heat spreader. A screen mesh is used as the one. To verify the validity of the one, the heat spreader of 1.4mm and 1.6mm thickness was made with 14 mesh and 100 mesh number. In this paper, The performance test of heat spreader conducted in order to compare with the heat transfer performance of conventional heat pipe. As the results, The heat spreader has excellent cooling and heat transfer performance.

  • PDF

비정질 강섬유 혼입 고강도콘크리트의 수증기압력 평가 (Evaluation on Water Vapor Pressure of Amorphous Steel Fiber reinforced High Strength Concrete)

  • 김덕우;김규용;황의철;손민재;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.44-45
    • /
    • 2018
  • In this study, water vapor pressure of high strength concrete reinforced with amorphous steel fiber(AF) was evaluated. Experimental results show that spalling occurs when the incorporation rate of amorphous steel fiber is 0.5 vol.% or more. This is because the ratio of AF increased per unit area influenced the formation of the water vapor pressure discharge passage by the polypropylene fiber(PPF) melting. Therefore, it is necessary to find the proper mixing ratio of AF and PPF to prevent spalling.

  • PDF

태풍 에위니아 영향력에서의 GPS 가강수량 변화 분석 (Analysis of GPS Precipitable Water Vapor Variation During the Influence of a Typhoon EWINIAR)

  • 송동섭;윤홍식
    • 대한토목학회논문집
    • /
    • 제26권6D호
    • /
    • pp.1033-1041
    • /
    • 2006
  • 본 연구에서는 2006년 7월 10일경 한반도에 영향을 미친 태풍 에위니아가 진행하는 동안 GPS/MET 기술을 이용하여 한반도의 GPS 가강수량의 시공간적 변화량을 계산하였다. 22개소의 GPS 상시관측소를 이용하여 1시간 간격의 대류권의 건조지연량과 습윤 지연량을 산출하고 지상기상관측 정보를 이용하여 가강수량으로 환산하였다. 가강수량으로 환산하기 위하여 가중 평균 기온식은 기존의 한국형 가중 평균 기온식 결정 연구에서 제시된 식을 적용하였다. 보다 정확한 GPS 가강수량의 결정을 위하여 기압 정보를 역해면 경정하여 관측소 해발고도상의 기압으로 환산하여 적용하였다. 최종적으로 GPS 가강수량도를 작성하여 태풍 에위니아 진행 동안 MTSAT 수증기 영상 및 레이더 영상과 함께 시공간적 변화를 비교하였다.

수증기안정동위원소를 이용한 해안지역 수분의 이동경로에 관한 연구 (Moisture Transport Observed by Water Vapor Isotopes in the Vicinity of Coastal Area, Incheon, Korea)

  • 이정훈;최희진;오진만;나운성;곽호제;허순도
    • 자원환경지질
    • /
    • 제46권4호
    • /
    • pp.339-344
    • /
    • 2013
  • 물의 순환의 복잡한 기작을 이해하는 데 수증기동위원소는 중요한 단서를 제공할 수 있으며 지구과학의 다양한 영역(고기후학, 수리지질학, 대기학, 해양학 및 생태학)에 적용될 수 있다. 수분의 전지구적 또는 지역적 이동에 대한 연구는 물의 순환 및 대기에서의 에너지이동을 좀 더 잘 이해하는 데 도움을 줄 것이다. 본 연구에서는 해안근처에서의 수분의 이동을 파악하기 위해서 태풍 볼라벤이 한반도를 통과하는 기간동안(2012년 8월 27일부터 8월 29일까지) 수증기의 안정동위원소를 극지연구소에 설치된 동위원소분석기를 이용하여 측정하였다. 수분동위원소의 두 동위원소의 선형관계식($D=7.8x^{18}O+10.1$)으로부터 해양 기원의 수증기가 증발에 의해 이동되어 측정되었음을 알 수 있었다. 날씨가 맑을 때는 해양으로부터 증발되어 다른 물리적인 변동없이 직접 이동된 수증기의 동위원소 조성(산소동위원소, ${\delta}^{18}O$=-14‰)을 보여 주었으며, 태풍이 통과하면서 수분동위원소의 값은 10‰ 정도 낮은 값을 보였다. 태풍의 통과로 인해 상대습도는 증가하였으며 수분동위원소값은 감소하는 소위 "우량효과(amount effect)"를 보여주었다.

A Study on the Flow Field Characteristics of Air Induction System for Reducing the Signal-to-Noise in the MAFS Output

  • 유성출
    • 한국분무공학회지
    • /
    • 제5권1호
    • /
    • pp.49-57
    • /
    • 2000
  • This study presents the flow visualization results, velocity and turbulence intensity measurements made within an air filter cover and entry region of a mass air flow sensor (MAFS) which is used in an induction system of 3.8L engine. Flow structure in two air filter cover assemblies were examined. The first was a clear plastic replica of the production cover while the second was a modified clear plastic cover with a geometry configured to reduce fluctuations. High speed flow visualization and laser doppler velocimetry (LDV) systems were used to reveal and analyze the flow field characteristics encountered in the sensor design process under steady flow conditions. A 40-watt copper vapor laser was used as a light source. Its beam is focused down to a sheet of light approximately 1.5mm thick. The light scattered off the particles was recorded by a 16mm high speed rotating prism camera at 5000 frames per second. A comparison of the flow patterns and LDV measurements in the original and modified air filter covers is presented to illustrate the controlling effect of the cover design on the turbulence structure formation near the bypass and on the sensor output signal. In both axial and radial planes of the main passage it was found that the turbulence flow pattern is remarkably influenced by the air filter cover and main passage configuration.

  • PDF

EVAPOTRANSPIRATION RATE AND GRAFT-TAKING OF GRAFTED SEEDLINGS UNDER ARTIFICIAL LIGHTING

  • Kim, Y. H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.632-638
    • /
    • 2000
  • This paper represents the characteristics of evapotranspiration rate (EVTR) and graft-taking of watermelon grafted seedlings in a graft-taking enhancement system using fluorescent lamps as artificial lighting source. Four air temperature levels of 23, 25, 27 and 29C, three humidity levels of 85, 90 and 95%R.H. and two photosynthetic photon flux (PPF) levels of 30 and 50 ${\mu}$mol m$\^$-2/ S$\^$-1/ were provided to investigate the effects of air temperature, relative humidity and light intensity on EVTR and graft-taking of grafted seedlings. EVTR of grafted seedlings increased with increasing air temperature and the passage of time after grafting. Also EVTR increased with decreasing relative humidity. As relative humidity decreased and air temperature increased, vapor pressure deficit increased and thus EVTR increased. It is required to maintain a low level vapor pressure deficit for suppressing EVTR of grafted seedlings during first 1-2 days after grafting. Therefore, less EVTR at initial stage after grafting would be adequate for smooth joining of the scion and rootstock.

  • PDF

수직관내 미포화수의 강제대류 천이비등에 대한 역학적 모델 (A Mechanistic Model for Forced Convective Transition Boiling of Subcooled Water in Vertical Tubes)

  • Lee, Kwang-Won;Baik, Se-Jun;Han, Sang-Good;Joo, Kyung-Oin;Yang, Jae-Young
    • Nuclear Engineering and Technology
    • /
    • 제27권4호
    • /
    • pp.503-517
    • /
    • 1995
  • 강제대류 천이비등 열유속을 보다 실제 적으로 예측하기 위한 역학적 모델을 개발하였다. 이 모델은 가열된 벽면 근처를 어떤 기포기둥(Vapor Blanket)이 통과할 때 일어나는 다단계 비등과정 즉, 임계 기포기둥의 형성, 기포기둥밑의 미소액막(Macrolayer)의 기화 및 고갈, 그리고 얇은 기체막에서 일어나는 불안정한 막비등과정에 기초하였다. 핵비등이탈점 (DNB )과 막비등이탈점 (DFB)사이의 천이비등 곡선상의 열유속은 임계 기포기둥이 주어진 벽면을 통과할 동안 상기한 각 비등과정의 지속 시간비(Time Fraction)를 각 비등열유속에 곱한 후 그것을 합하여 정량화하였다. 이 모델의 예측치를 현재까지 발표된 문헌들에 나타난 실험치와 비교한 결과, 본 모델은 저건도 및 10 bar 근처의 고압조건의 실험치를 잘예측하는 것으로 나타났다.

  • PDF

소결금속 윅과 메탄올을 사용하며 바이패스라인이 부착된 루프히트파이프의 작동 특성 (Operating Characteristics of a Sintered-Metal Wick/Methanol Loop Heat Pipe Having a Bypass Line)

  • 부준홍;정의국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2130-2135
    • /
    • 2007
  • Operating characteristics of a loop heat pipe (LHP) having a bypass line was investigated experimentally. The LHP had a sintered metal wick as a capillary structure and methanol as a working fluid. The sintered metal wick was made of stainless steel of which the average pore size was 5 ${\mu}m$and porosity of 47%. A bypass line of a small diameter was attached between the vapor escape passage and the liquid reservoir. The dimension of the flat evaporator was $50(L){\times}40(W){\times}30(H)$ mm and that of the condenser was $50(L){\times}40(W){\times}11(H)$ mm. Wall and pipe material of the LHP was stainless steel and heating area was 35(W) mm${\times}$35(L) mm. The inner diameters of vapor and liquid transport lines were 4.0 mm and 2.0 mm, and the lengths of the two lines were both 0.5 m. The LHP was tested for three different tilt angles of horizontal, favorite tilt, and adverse tilt. The thermal load range was up to 290 W at the condenser above evaporation position. Furthermore, the effect of a bypass line on the start-up transient as well as steady-state operation was presented and discussed.

  • PDF

지상용 소형 루프히트파이프 성능에 관한 연구 (Thermal Performance of a Small-scale Loop Heat Pipe for Terrestrial Application)

  • 정원복;부준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1052-1057
    • /
    • 2004
  • A small-scale loop heat pipe with polypropylene wick was fabricated and tested for its thermal performance. The container and tubing of the system was made of stainless steel and several working fluids were used to see the difference in performance including methanol, ethanol, acetone, R134a, and water. The heating area was 35 mm ${\times}$ 35 mm and there were nine axial grooves in the evaporator to provide a vapor passage. The pore size of the polypropylene wick inside the evaporator was varied from 0.5 m to 25 m. The size of condenser was 40 mm (W) ${\times}$ 50 mm (L) in which ten coolant paths were provided. The inner diameter of liquid and vapor transport lines were 2.0 mm and 4.0 mm, respectively and the length of which were 0.5 m. The PP wick LHP was operated with methanol, acetone, and ethanol normally. R134a was not compatible with PP wick and water was unsuitable within operating limit of $100^{\circ}C$. The minimum thermal load of 10 W (0.8 W/cm2) and maximum thermal load of 80 W (6.5 W/cm2) were achieved using methanol as working fluid with the condenser temperature of $20^{\circ}C$ with horizontal position.

  • PDF