• Title/Summary/Keyword: Valve-opening pressure

Search Result 191, Processing Time 0.031 seconds

Flow Measurements at the Exit of a Throttle Valve in Gasoline Engines (가솔린 엔진의 스로틀 밸브 출구에서 유동측정)

  • Kim, Sung-Cho;Kim, Cheol;Choi, Jong-Geon;Wee, Hwa-Bok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 2002
  • The flow and combustion patterns have been investigated inside the gasoline engine cylinder with the swirl or tumble flow, whereas the air flow characteristics, which are generated in the part of intake system before entering into the intake manifold, have not been known completely. It is necessary to analyze the flow field in the intake system consisting of air rater, throttle valve and intake manifold. The throttle valve, used to control the intake air flow rate, is important because it makes various mass flow rate and flow patterns. Three-dimen-sional How characteristics such as velocities, turbulent intensities and Reynolds shear stresses are measured by the hot wire anemometer at the exit of the throttle valve with the variation in the valve opening angle($15^{\circ}$, $45^{\circ}$, $75^{\circ}$ and $90^{\circ}$) and the Reynolds numbers (45000, 70000 and 140000). There are a lot of changes in flow characteristics at $75^{\circ}$ due to the large recirculation flow comparing with those of the other cases, and the streamwise velocity is especially enforced strongly below the valve shaft. The other component velocities are relatively large near the centerline parallel to the valve shaft. The effects of the Reynolds number on the flow field are not severe.

Design review of fuel vent-relief valve (연료 벤트/릴리프 밸브의 설계 분석)

  • Jang, JeSun;Kil, GyoungSub;Han, SangYeop;Park, Jong-Ho
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2012
  • A vent-relief valve performs as a safety-valve assembly for liquid propellant feeding system of space launch vehicle, which relives pressurant propellant tanks during the filling and the flight. At vent mode, valve is opened and closed by driving pneumatic pressure, and at relief mode, valve is automatically operated to set relief pressure. In this study, we have analyzed a basic layout of vent-relief valve which is designed using foreign LVs(Saturn) to satisfy requirements of Korean Space Launch Vehicle. The simulation model of vent-relief valve is designed by using the AMESim code to verify design parameters and evaluate pneumatic behaviors of valve. In this study, we performed dynamic characteristic simulations on design parameters. And we could predict opening/closing time and pressures, operating performances on design parameters. Using this results, we could suggest detail design and boundary conditions of design.

Optimization of Diesel Engine Performance with Dual Loop EGR considering Boost Pressure, Back Pressure, Start of Injection and Injection Mass (과급압력, 배압, 분사 시기 및 분사량에 따른 복합 방식 배기 재순환 시스템 적용 디젤 엔진의 최적화에 대한 연구)

  • Park, Jung-Soo;Lee, Kyo-Seung;Song, Soon-Ho;Chun, Kwang-Min
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.136-144
    • /
    • 2010
  • Exhaust gas recirculation (EGR) is an emission control technology allowing significant NOx emission reduction from light-and heavy duty diesel engines. The future EGR type, dual loop EGR, combining features of high pressure loop EGR and low pressure loop EGR, was developed and optimized by using a commercial engine simulation program, GT-POWER. Some variables were selected to control dual loop EGR system such as VGT (Variable Geometry Turbocharger)performance, especially turbo speed, flap valve opening diameter at the exhaust tail pipe, and EGR valve opening diameter. Applying the dual loop EGR system in the light-duty diesel engine might cause some problems, such as decrease of engine performance and increase of brake specific fuel consumption (BSFC). So proper EGR rate (or mass flow) control would be needed because there are trade-offs of two types of the EGR (HPL and LPL) features. In this study, a diesel engine under dual loop EGR system was optimized by using design of experiment (DoE). Some dominant variables were determined which had effects on torque, BSFC, NOx, and EGR rate. As a result, optimization was performed to compensate the torque and BSFC by controlling start of injection (SOI), injection mass and EGR valves, etc.

Flow Structure Interaction 3-D Reciprocating Compressor and Impact Analyses of Compressor Discharge Valve (압축기 토출벨브의 유체-구조 연계해석 및 충돌해석)

  • Octavianty, Ressa;Kim, Dong-Hyun;Park, Kang-Gyun;Jung, Won-Hyun;Ahn, Jae-Woo;Moon, Kyeong-Ho;Ko, Young-Pil;Kim, Hyeong-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.633-640
    • /
    • 2007
  • In this paper, 3-D reciprocating compressor is taken into flow-structure interaction analysis. The full cycle process consisted of cylinder expansion and compression has been modeled without considering flow leakage through cylinder wall. Fully-coupled FSI analysis of this compressor model was iteratively solved and gives sufficient result with the experimental test. The study is emphasized to thoroughly investigate discharge valve motion, opening and closing, in order to determine discharge valve region which is prone to have high effective stress. The cylinder pressure is successfully validated before conducting impact analyses between discharge valve and other susceptible supported structure. Velocity profile has been obtained in FSI analysis is used as initial condition to carry out further impact analyses. Stress result of discharge valve and valve spring gives preliminary estimation of higher stress area due to its impact phenomena.

  • PDF

The Sensitivity Analysis for LRV Opening Pressure in CANDU (중수로 원전에서 액체방출밸브의 개방압력에 대한 민감도평가)

  • Kim, S.M.;Kho, D.W.;You, S.C.;Kim, J.H.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.40-44
    • /
    • 2015
  • Sensitivity on the reactor safety was evaluated for the safety margin and time delay applied to the opening pressure of liquid relief valve(LRV) of the primary heat transport system(PHTS) in the pressurized heavy water reactor(PHWR) type nuclear power plant. Since the LRV is the pressure boundary for the PHTS in the safety analysis, the operating of LRV has a significant effect on the safety analysis results. Therefore it is required during the regulatory review of Wolsong Unit 1 safety analysis to find the safety effect of the application of safety margin and time delay to the LRV opening pressure for the safety analysis of PHTS pressurizing events.

A Numerical Study on the IRWST Pool Temperature Distributionin in APR1400 (APR1400 IRWST Pool 온도분포 해석)

  • Kang, Hyung-Seok;Bae, Yoon-Y.;Park, Jong-Kyung
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.813-820
    • /
    • 2001
  • The Safety depressurization System(SDS) of KNGR prevents RCS from overpressurization by discharging high pressure and temperature coolant through the I-sparger into the IRWST during an accident. If IRWST water temperature rise locally, around the sparger, beyond $200_{\circ}$2000 F by the discharged coolant, unstable steam condensation can cause large pressure load on the IRWST wall. To investigate whether this condition can be avoided for the design basis event IOPOSRV(Inadvertent Opening of one Pilot Operated Safety Relief Valve), the flow and temperature distribution of water in the IRWST is calculated by using CFX 4.3 computational fluid dynamic code. According to the results, since pool water temperature does not exceeds temperature limit within 50 seconds after the opening of one POSRV, it can be assured that the integrity of IRWST wall is maintained.

  • PDF

MODELING OF PRESSURE CONTROL SYSTEM OF BOILER (보일러 풍압 제어 계통의 모델링)

  • Park, Min-Ho;Mok, Hyung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.362-366
    • /
    • 1987
  • The amount of inflowing Air into the boiler has controlled by manipulating the opening of valve, damper and vane, as fan operated by induction motor operats at constant speed, but these control methods are not efficient. Thus VVVf(Variable Voltage Variable Frequency) control of fan has selected to improve efficiency and to acquire power savings. Control system of Air Flow is affected by nonlinearity caused by load variation, vane opening, etc. The analysis of control parameter causing nonlinearity is needed to acquire optimal control and excellent transient response. This paper provides modeling of boiler with various load conditions and vane opening, and analysis of this system.

  • PDF

Pressure Variations in Intake and Exhaust Manifold of a Single Cylinder Engine (단기통 엔진의 흡.배기계의 압력 변동에 관한 연구)

  • Choi, Seuk-Cheun;Lee, Young-Hun;Lee, Sang-Chul;Chung, Han-Shik;Lee, Kwang-Young;Jeong, Hyo-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.775-780
    • /
    • 2003
  • In this study, a computer analysis has been developed for predicting the pipe pressure of the intake and exhaust manifold in a single cylinder engine. To get the boundary conditions for a numerical analysis, one dimensional and unsteady gas dynamic calculation is performed by using the MOC(Method Of Characteristic). The main numerical parameters are the variation of the exhaust pipe diameters to calculate the pulsating flow when the intake and exhaust valves are working. As the results of numerical analysis, the shapes and distributions of the exhaust pipe pressures were influenced strongly on the cylinder pressure. As the exhaust pipe diameter is decreased, the amplitude of exhaust pressure is large and the cylinder pressure was showed low in the region of intake valve opening time.

  • PDF

Analysis and Performance Test of an Electronic Expansion Valve for CO2 (CO2 냉매용 전자팽창밸브의 해석 및 평가)

  • Kim, Ook-Joong;Yoon, Seok-Ho;Hong, Yong-Ju;Kim, Jeong-Yup;Kang, Sin-Il
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1491-1496
    • /
    • 2009
  • Fluid flow and structural analyses of an electronic expansion valve (EEV) using CO2 as a working refrigerant are carried out to estimate the mass flow rate and maximum stress. An engineering sample EEV that the orifice diameter is 1.8 mm was fabricated. The mass flow rates were measured at various EEV inlet temperatures and pressures for several EEV openings using experimental heat pump system. The sample EEV has over 35 MPa burst pressure and the maximum mass flow rate of CO2 through the EEV increased to 100 g/s at full opening condition.

  • PDF

A Study on the Bandwidth Frequency of Directional Control Valves based on the Amplitude of the Metering-Orifice Pressure (미터링 오리피스 압력 진폭을 이용한 방향제어밸브 대역폭 주파수에 관한 연구)

  • Kim, Sungdong;Jeon, Sehyeong;Shin, Daeyoung
    • Journal of Drive and Control
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • The spool displacement of a directional control valve can be considered as the standard signal for the measurement of its bandwidth frequency. When the spool displacement is not available, the metering-orifice system is suggested in this study as an alternative way to measure the - 3 dB amplitude-ratio bandwidth frequency of the hydraulic directional-control valve. The amplitude ratio of the metering-orifice pressure can be adjusted to equal that of the spool displacement through the controlling of the metering-orifice opening area. A series of experiments were conducted to verify the effectiveness of the metering-orifice system. The metering orifice was confirmed as adequate for the measurement of the - 3 dB amplitude-ratio bandwidth frequency.