• Title/Summary/Keyword: Valve opening speed

Search Result 54, Processing Time 0.023 seconds

Experimental Study for Investigating the Optimum Operating Conditions of a Seawater Ice Machine (해수제빙장치의 최적 운전 조건 탐색을 위한 실험적 연구)

  • Li, H.;Joo, W.J.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.76-82
    • /
    • 2010
  • This paper investigates the optimum operating conditions to construct total automatic control system with high energy efficiency of a newly developed seawater ice machine. The machine has an electronic expansion valve(EEV) and a variable speed rotating drum with an evaporator installed inside. The coefficient of performance(COP) was used as an index to evaluate energy efficiency of the machine. At first, the opening angle of EEV was adjusted to obtain COP of the machine at a constant speed of the drum. Then, we checked seawater ice product versus opening angles of the EEV. Finally, effect of drum's rotating speed in response to product of seawater ice and seawater ice temperature were considered.

Analysis and Evaluation of Capillary Passive Valves in Microfluidic Systems Using a Centrifugal Force

  • Cho, Han-Sang;Kim, Ho-Young;Kang, Ji-Yoon;Kwak, Seung-Min;Kim, Tae-Song
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.155-159
    • /
    • 2004
  • This work reports the theoretical and experimental investigations of capillary bust valves to regulate liquid flow in microchannels. The theoretical analysis uses the Young-Laplace equation and geometrical considerations to predict the pressure at the edge of the valve opening. Numerical simulations are employed to calculate the meniscus shape evolution while the interface is pinned at the valve edge. Microchannels and valves are fabricated using soft lithography. A wafer-rotating system, which can adjust the driving pressure by rotational speed, induces a liquid flow. Experimentally measured valve-bursting pressure agrees with theoretical predictions.

Cooling and Heating Performances of a CO2 Heat Pump with the Variations of Operating Conditions (운전조건 변화에 따른 이산화탄소 열펌프의 냉난방 성능특성 비교)

  • Cho, Hong-Hyun;Baek, Chang-Hyun;Lee, Eung-Chan;Kang, Hun;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.6
    • /
    • pp.454-462
    • /
    • 2008
  • Since operating conditions are significantly different for heating and cooling mode operations in a $CO_2$ heat pump system, it is difficult to optimize the performance of the $CO_2$ cycle. In addition, the performance of a $CO_2$ heat pump is very sensitive to outdoor temperature and gascooler pressure. In this study, the cooling and heating performances of a variable speed $CO_2$ heat pump with a twin-rotary compressor were measured and analyzed with the variations of EEV opening and compressor frequency. As a result, the cooling and heating COPs were 2.3 and 3.0, respectively, when the EEV opening was 22%. When the optimal EEV openings for heating and cooling were 28% and 16%, the cooling and heating COPs increased by 3.3% and 3.9%, respectively, over the COPs at the EEV opening of 22%. Beside, the heating performance was more sensitive to EEV opening than the cooling performance. As the compressor speed decreased by 5 Hz, the cooling COP increased by 2%, while the heating COP decreased by 8%.

The Characteristic Study of Capacity Control of an Industrial Cooler Using an Invertor Compressor with Varing the Ambient Temperatures (인버터 압축기를 채용한 산업용 수냉각기의 외기온도 변화에 따른 용량제어 특성)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.238-243
    • /
    • 2011
  • The ambient temperature of the experimental conditions changes by varying the speed of the compressor and the electronic expansion valve opening. The effects of changing valve opening to the entire system has been investigated. The results show that the ambient temperatures of $35^{\circ}C$ and $30^{\circ}C$ controlled at 30Hz must be avoided. The capacity control range of the control compressor with changing speed is about 43~100% at $35^{\circ}C$, 43~100% at $25^{\circ}C$ and 48~100% at $10^{\circ}C$, respectively. The results show the capacity control range decreases with decreasing ambient temperature.

MODELING OF PRESSURE CONTROL SYSTEM OF BOILER (보일러 풍압 제어 계통의 모델링)

  • Park, Min-Ho;Mok, Hyung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.362-366
    • /
    • 1987
  • The amount of inflowing Air into the boiler has controlled by manipulating the opening of valve, damper and vane, as fan operated by induction motor operats at constant speed, but these control methods are not efficient. Thus VVVf(Variable Voltage Variable Frequency) control of fan has selected to improve efficiency and to acquire power savings. Control system of Air Flow is affected by nonlinearity caused by load variation, vane opening, etc. The analysis of control parameter causing nonlinearity is needed to acquire optimal control and excellent transient response. This paper provides modeling of boiler with various load conditions and vane opening, and analysis of this system.

  • PDF

A Study on Exhaust Gas Characteristics and Engine Performance of EGR Valve Installed Engine for Development of EGR Valve Test System (EGR 밸브 평가 장치 개발을 위한 EGR 장착 엔진 성능 및 배출 가스 특성 연구)

  • Na, D.H.;Ko, C.S.;Seo, H.J.;Lee, C.E.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.52-57
    • /
    • 2012
  • In this study, in order to understand contents and ranges of design for the EGR Valve test system for improving quality and performance of EGR Valve, engine performance and exhaust gas characteristic of 3L-class diesel engine was analyzed. Experimental operation of engine performance test was performed with 50% engine load and 20% and 100% opening ratio of EGR Valve. From test of performance and exhaust gas characteristic of engine, torque output of engine and temperature and pressure of inlet and outlet of EGR Valve were measured. As a result, for design of EGR Valve test system, input fluid flow of EGR Valve must be set the same amount with exhaust gas flow that was below of engine speed of 2,500 rpm, and temperature of inlet of EGR Valve must be set under about $510^{\circ}C$. And the difference of temperature between inlet and outlet of EGR Valve must be over than about $200^{\circ}C$. Exhaust gas of inlet and outlet of EGR Valve were under 1 bar that was not considerable, and the difference of pressure between inlet and outlet of EGR Valve were under 1 bar that could not effect on mechanical operation of EGR Valve.

A Numerical Analysis for Fuel Consumption by Improvement of Intake/Exhaust Valve Timing in a Common Rail Diesel Engine for a Generator (커먼레일 디젤엔진의 흡배기밸브 타이밍 개선을 통한 연비절감에 대한 수치해석적 연구)

  • Kim, Seung Chul;Kim, Chung Kyun
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.32-38
    • /
    • 2017
  • The common rail diesel engine used in this study uses mechanically driven camshaft for the operation of intake and exhaust valves, and the timing of valve opening and closing is fixed according to the operating conditions of the vehicle. However, the electric generator engine operates at a constant speed and partial load. Therefore, in order to optimize the design of common rail diesel engine for power generation, the characteristics of diesel combustion and emissions according to the change of valve timing were examined and calculated in terms of fuel economy. The valve timing of the diesel engine influenced the combustion characteristics by changing the intake and exhaust flow and it was considered that the fuel efficiency of the generator could be improved.

An Empirical Model for Decoupling Control of a Variable Speed Refrigeration System (가변속 냉동시스템의 비간섭제어를 위한 실험적 모델)

  • Hua, Li;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.81-87
    • /
    • 2006
  • This paper deals with an empirical model for decoupling control to control the refrigeration system effectively. The conventional control schemes of the system are mainly focused on representative two control methods, superheat control and capacity control. The capacity control is basically conducted to respond partial loading conditions on the purpose of energy saving. The superheat control is mainly carried out to maintain maximum coefficient of performance (COP). In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. The capacity and superheat can not be controlled independently because of interfering loop when the compressor speed and opening angle electronic expansion valve is varied. Therefore, we suggest decoupling model to eliminate the interfering loop at first. Next, each transfer function in decoupling control model is obtained from number of experiments.

  • PDF

Experimental Study on the Cooling Performance of a Variable Speed $CO_2$ Cycle with Internal Heat Exchanger and Electronic Expansion Valve (내부열교환기 및 전자팽창장치를 적용한 가변속 이산화탄소 사이클의 냉방성능에 관한 실험적 연구)

  • Cho Honghyun;Ryu Changgi;Kim Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.209-215
    • /
    • 2005
  • Since a transcritical $CO_2$ cycle shows lower performance than conventional air conditioners in the cooling mode operation, it is required to enhance the performance of the $CO_2$ cycle by applying advanced technologies and optimizing components. In this study, the cooling performance of a $CO_2$ system measured by varying refrigerant charge amount, compressor frequency, EEV opening and length of internal heat exchanger. As a result, the cooling COP of the basic system without internal heat exchanger was 2.1. The cooling performance of the modified cycle applying internal heat exchanger improved by $4-9\%$ over the basic cycle.

Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System (오일쿨러의 고정밀 온도 제어를 위한 PI 및 피드포워드 제어기 설계)

  • Byun, J.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.89-95
    • /
    • 2010
  • This paper deals with design method of proportional-integral(PI) and feedforward controller for obtaining precise temperature and high energy efficiency of oil cooler system in machine tools. The compressor's speed and opening angle of an electronic expansion valve are controlled to keep reference value of temperature at oil outlet and superheat of an evaporator. Especially, the feedforward controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.l^{\circ}C$ and maximum overshoot $0.2^{\circ}C$ under abrupt disturbances.