• Title/Summary/Keyword: Valve noise

Search Result 274, Processing Time 0.023 seconds

Modeling and Dynamic Characteristics Analysis of a Continuously Variable Damper with Reverse type Semi-active Suspension. (반능동현가장치용 리버스 무단연속가변댐퍼의 모델링 및 동특성 해석)

  • 박재필;최창림;윤영환;최병근;정용길
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.937-941
    • /
    • 2004
  • Since semi-active suspension systems of automobile, of which suspension damper are controlled actively, exhibit high performance with light system weight, low cost and low energy consumption. From this view point, semi-active suspension systems are greatly expected to be in the mainstream of future controlled suspension systems. In this Paper, mathematical modeling and dynamic characteristics analysis of a reverse continuously variable damper and valve used for semi-active suspension systems are investigated. The mathematical model of piston with valve are proposed by IMAGINE/AMESim in the paper. To verify the mathematical model developed, the dynamic characteristics are simulated by IMAGINE/AMESim and are compared with experimental results. It was confirmed that the developed models represent well the actual system and can be used for control system design.

  • PDF

Identification of Noise Source from Main Steam Line in Power Plant (발전소 주증기 배관 소음 발생 원인 규명)

  • Sohn, M.S.;Lee, J.S.;Lee, S.K.;Lee, W.R.;Lee, S.K.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.23-28
    • /
    • 2003
  • In heavy nuclear power plant, high energy through main steam line is provided to turbine that generate the electric power. Since plant had generated power, high noise has been occurred. Noise make equipments and work environment worse. For finding out the location and the cause of making noise, noise was measured along main steam line at open/close test of Main Steam Isolation Valve (MSIV hereafter). As the result, it was identified that the vortex shedding in the cavity of MSIV is main noise source. The profile change of MSIV seat ring was proposed as the method of noise reduction. After filletting MSIV seat ring, the noise level reduced $10{\sim}20dB$ compared before the change of profile.

  • PDF

A Study on Falling Pressure Surge of ABS Using High Frequency PWM Control (고주파수 PWM제어를 이용한 ABS의 맥동 저감에 관한 연구)

  • Lee, Yong-Joo;Kim, Byeong-Woo;Park, Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.3
    • /
    • pp.38-44
    • /
    • 2003
  • The solenoid valve in ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the valve is switched from open state to closed state, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder are made. In this study, we identify Pressure surge phenomenon in the braking process of a ABS, and investigate the way to reduce the phenomenon. For the purpose of theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. To reduce the surge, high frequency control of 20kHz was attempted. The result showed that the surge pressure of 50% was reduced compared to one observed in the low frequency control. Duty variation of high frequency can control current of solenoid valve and prevent sudden change of displacement.

Development of numerical method to predict broadband radiation noise resulting in fluid-induced vibration and acoustic-induced vibration of pipe (배관의 유동 유발 진동 및 음향 유발 진동 기인 광대역 방사 소음 예측을 위한 수치 해석 기법 개발)

  • Sangheon Lee;Cheolung Cheong;Songjune Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.112-121
    • /
    • 2024
  • The pipping system is widely used in many industries as equipment for transporting fluids over long distances. In high-pressure pipe, as the speed of the fluid increases, a loud noise is generated. Therefore, various studies have been conducted to reduce pipe noise. In this paper, a pipe noise analysis was developed to predict and quantitatively assess the flow-induced vibration and acoustic-induced vibration due to valve flow in high-temperature and high-pressure. To do this, a high-fidelity fluid analysis technique was developed for predicting internal flow in the pipe with valve. In additional, the contribution of compressible/incompressible pressure by frequency band was evaluated using the wavenumber-frequency analysis. To predict a low/middle frequency pipe noise, the vibroacoustic analysis method was developed based on Finite Element Method (FEM). And the pipe noise prediction method for the middle/high frequency was developed based on Statistical Energy Analysis (SEA).

Prediction of Two-phase Flow Patterns and Noise Evaluation for Evaporator Pipe in a Refrigerator (냉장고 증발기 배관의 2상유동양식 예측 및 소음 평가)

  • Heo, So-Jung;Kim, Min-Seong;Han, Hyung-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.916-923
    • /
    • 2011
  • The refrigerant after the expansion valve interchanges the heat at the evaporator. At this moment, the state of gas and liquid becomes two-phase flow and causes irregular noise. In order to avoid the noise, the two-phase flow pattern should be predicted. In this paper, the procedure to predict the two-phase flow patterns such as churn flow and annular flow was suggested using the CFD software. The experiments using refrigerant-supplying equipment was carried out and the noise levels according to the flow pattern were measured. The flow patterns predicted by this procedure showed good agreement with those by experiments. The churn flow is noisier than annular flow pattern.

Reduction of airborne and structure-borne noise of naval ship pump (함정용 펌프의 공기음 및 고체음저감)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.942-947
    • /
    • 2002
  • In this study, reduction of airborne and structure-borne noise of naval ship pump is presented. Since piping system arrangement such as valve location, flexible joint, pipe diameter and elbow location, discharge basin affect greatly on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system. It is shown that structure-borne noise of the motor with single resilient mount system exceeds criterion. Therefore, it is concluded that double resilient mount system is inevitable. Two kinds of mount is studied for upper mount; spring and rubber type. Although both mounts show good performance at low frequency including rpm frequency, 63Hz, spring mount is found to be inadequate at high frequency, because spring coil acts as a path for SBN.

  • PDF

Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review

  • Spencer C. Lacy;Mina M. Benjamin;Mohammed Osman;Mushabbar A. Syed;Menhel Kinno
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.108-115
    • /
    • 2023
  • BACKGROUND: Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS: We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS: We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS: This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.

Valve induced noise and vibration evaluation procedure for process piping of offshore production facility (Offshore 선 Process 배관계의 밸브 소음/진동 평가 절차)

  • Lee, JooHun;Choi, ChoongYoung;Kim, JaeHong;Kwun, Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.201-204
    • /
    • 2014
  • Recent year, the vibration induced fatigue and noise of piping work become critical in offshore hydrocarbon production facilities with increasing requests by major oil company. In this paper, the risk base piping vibration induced fatigue assessment of NORSOK L-002 standard and UK Energy Institute guideline have been introduced with real project application practice. Also the piping breakout noise evaluation by flow restriction devices of compressible and in-compressible flow are reviewed with its practical application on real project.

  • PDF

An Experimental Study on the Acoustic Characteristics of a Reciprocal Compressor (냉장고용 왕복동식 압축기의 소음특성에 관한 실험적 연구)

  • 박철희;차용웅;홍성철;주재만;김영헌;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.196-201
    • /
    • 1997
  • In point of noise and vibration, it is easy to occur a noise and vibration, because the reciprocal compressor is composed of crank shaft, rod piston and etc. Therefore, it is important to understand the mechanism of reciprocal compressor. In this study, we measured the sound pressure level of compressor. There are two dominent frequencies. The first of one results from the suction part. In suction process, the suction valve flutteres, and it produces the noise of the first frequency. The other results from the structural vibration of the shell resonated by discharge pipe. Thus, to reduce the noise of compressor, it will be most efficiency to redesign muffler for the first frequency and discharge pipe for the second frequency.

  • PDF

The Effects of an Abnormal Adjusting Intake and Exhaust Valves on the Combustion Characteristics of SI Engine (흡.배기 밸브의 밀착이상이 엔진연소특성에 미치는 영향)

  • Park Kyoung-Suk;Son Sung-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.123-129
    • /
    • 2005
  • The unbalance of the power output, noise, and vibration is happened by the disproportionate pressure variation in the cylinder. For this reason, decrease of the pressure in the cylinder and increase of the residual gas effect on the engine performance. If the abnormal combustion is continued, the crack would be occurred in the engine block. And it could be broken down. For the normal combustion of the SI engine, it is important to supply the balanced mixture by each operating condition. In this study, it was tested the combustion characteristics in the cylinder according to the abnormal adjusting of intake & exhaust valve. This test is willing to set a basic data's analysis fur developing an automotive diagnosis system by analyzing the pressure in the cylinder, the output signal of MAP sensor, the exhaust gas, etc.