• Title/Summary/Keyword: Valve Monitoring

Search Result 129, Processing Time 0.036 seconds

Implementation of Monitering system of Electromotion valve using 8255A (8255A를 이용한 전동밸브의 모니터링 시스템 구현)

  • Cho, Hyun-Seob;Ryu, In-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1694-1695
    • /
    • 2007
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal(Al2O3) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($Al_{2}O_{3}$) growth and we will design about realtime monitoring systems of the automatic gas contol DC- Motor for single crystal($Al_{2}O_{3}$) growth

  • PDF

Development of Remote Monitoring System of Temperature Controller for Cold-Storage (저온냉장장치용 온도제어기의 원격 모니터링 시스템 개발)

  • Lim, Dae-Young;Ryoo, Young-Jae;Chang, Young-Hak;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2486-2488
    • /
    • 2003
  • This paper describes a remote monitoring system of temperature controller for cold-storage, of farm produce. In the cold-storage, it is important that farm produces are fresh. Unfortunately, when an operator goes out from the cold-storage temperature change could be occurred due to the various reasons, for an example, a valve of cooler is broken. The temperature change results in a serious problem of the quality of farm produce. To prevent the problem, the operator has to look to the current state of the temperature of the cold-storage, even he is in long away. Thus, the monitoring system to show the temperature should be required to the operator who can move away. Therefore, this paper propose of the remote monitoring system of the temperature. The proposed system is expected to help the operator's facilities, and the management of farm produce.

  • PDF

A Studies on the Bio-monitoring using Shell Valve Movements (SVMs) of Pacific Oyster Crassostrea gigas for Toxic Dinoflagellates, Genus Alexandrium (참굴, Crassostrea gigas의 패각운동을 이용한 유독와편모조 Alexandrium 속의 모니터링 연구)

  • Kim, Yoon Jeong;Yoon, Yang Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.778-784
    • /
    • 2017
  • We investigated the possibility of a bio-monitoring system for predicting toxic dinoflagellates (Genus Alexandrium) by the measuring shell valve movements(SVMs) of Pacific oyster, Crassostrea gigas (Mollusca: Bivalvia) using the Hall element sensor. We then described the SVMs of Pacific oyster exposed to the toxic algae under laboratory conditions. Pacific oyster used for experiment were fed Isochrysis galbana until they stabilized and kept under hunger conditions for three days to prevent the influence of food before the experiment. Pacific oyster were exposed to the toxic dinoflagellate, A. fundyense, and the potentially toxic dinoflagellate, A. affine. When Pacific oyster were exposed to A. fundyense, SVMs increased over 10 times/hr at low cell densities of 20 cells/mL. SVMs increased again at $14.1{\pm}5.7times/hr$ at 500 cells/mL, and $27.9{\pm}11.1times/hr$ at the high cell density of 5,000 cells/mL. However, in the presence of A. affine, SVMs increased at $6.7{\pm}3.9times/hr$ until 300 cells/mL, while they increased greatly to $15.3{\pm}10.8times/hr$ at 1,000 cells/mL. The SVMs of Pacific oyster indicated differences depending on species for toxic dinoflagellates. Therefore, the SVMs of Pacific oyster could be useful for A. fundyense, but would bedifficult to apply for A. affine.

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

Development of electro hydraulic ballast remote valve control system with diagnostic function using redundant modbus communication (이중화 모드버스 통신을 이용한 퍼지기반 고장진단기능을 가진 선박 밸러스트 전기유압식 원격밸브제어시스템 개발)

  • Kim, Jong Hyun;Yu, Yung Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.292-301
    • /
    • 2014
  • This paper describes development of distributed type independent electro-hydraulic ballast valve remote control system with diagnostic function based on fuzzy inference using redundant Modbus communication and ethernet Modbus TCP/IP. Diagnostic function estimate degradation of system components and diagnose system faults, which results in shortage of fault maintenance time and improvement of system safety. Slave devices which control each valve and master device which command, monitor and diagnose slave system are developed. Slave devices are connected to master device with redundant Modbus networks and master device is connected to ship's integrated control system with Modbus TCP/IP. Also this paper describes development of simulator to test and confirm whether developed system can be integrated with ship's integrated control and monitoring system.

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.

The Study of Control Algorithm for Stand alone PV System (독립헝 태양광 발전 시스템의 제어 알고리즘에 관한 연구)

  • Kim, Tae-Yeop;Jung, Maeng-Hwa;Goh, Gweon-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1382-1384
    • /
    • 2002
  • The flooded type battery is used for solar lighting system. Because the characteristic of flooded type battery is the short life time, the maintenance cost is high. So the using flooded type battery in this system is inappropriate. The valve regulated lead acid batter.(VRLA) is the maintenance free and cycle service purpose. This paper presents the development of control system and monitoring system to applied VRLA battery for maintenance free and long life time in system.

  • PDF

The Study of Thyristor Valve Water Cooling Control Systems (대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구)

  • 임익헌;류호선
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF

A Design of Realtime Monitoring System of Automatic gas Control DC-MOTOR for Single Crystal($A1_2O_3$) growth (단결정($A1_2O_3$) 성장을 위한 자동가스 조절용 DC-MOTOR의 실시간 모니터링 시스템 구현)

  • Lee, Hyung-Chung;Park, Chong-Kug;Cho, Hyeon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2489-2491
    • /
    • 2004
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal($A1_2O_3$) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($A1_2O_3$) growth and we will design about realtime monitoring systems of the automatic gas control DC- Motor for single crystal($A1_2O_3$) growth.

  • PDF

Development of Solar Lighting Controller and Monitoring System (태양광 가로등 제어장치 및 모니터링 시스템 개발)

  • Kim, Tae-Yeop;Jung, Maeng-Hwa;Goh, Kwon-Sung;Yoo, Kwang-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.331-333
    • /
    • 2001
  • The flooded type battery is used for solar lighting system. Because the characteristic of flooded type battery is the short life time, the maintenance cost is high. So the using floe fed type battery in this system is inappropriate. The valve regulated lead acid batter(VRLA) is the maintenance free and cycle service purpose. This paper presents the development of control system and monitoring system to applied VRLA battery for maintenance free and long life time in system.

  • PDF