Anticoagulation therapy with warfarin sodium is used to reduce the risk of thromboembolic events in patients with valvular heart disease, prosthetic heart valve, recurrent myocardiac infarction, etc. To keep anticoagulation state and minimize bleeding risk, patients with high risk of thromboembolism have been usually hospitalized for heparinization before oral surgery like extraction. However, this protocol requires time and high expense because of the long period of hospitalization and this is why low-molecular-weight heparin (LMWH) therapy is receiving attention in medical field as well as dentistry. LMWH has several advantages over unfractionated heparin (UFH) including predictable anticoagulant response which makes coagulation monitoring unnecessary in most patients and longer half-life than heparin which enables the patients to give themselves a subcutaneous injection once or twice daily. These advantages of LMWH make patients get oral surgery on an outpatient basis so that they can save time and cost. This case report introduces the use of LMWH in dental surgery and suggests proper use of LMWH. Though LMWH bridging therapy is widely used most of the previous studies are observational studies. Therefore randomized controlled trials are necessary to evaluate the safety and efficacy of LMWH bridging therapy.
The purpose of CBA(cost-benefit analysis) in risk assessment is to show whether the benefits of implementing additional risk reduction methods(RRMs) derived through risk assessment outweigh its costs and it is proper to implement the methods. In this paper CBA has been conducted in order to select the most effective and reasonable RRM as implementing the RRM derived after QRA for the high pressure urban gas pipelines. As conducting QRA again by applying the derived RRMs, No. 10 measure which includes pipeline corrosion monitoring, MOV(motor operated valve) installation and the method to protect pipeline damage caused by third-party mechanical interference has showed the highest risk reduction effect. Also it has been considered to be reasonably practicable by conducting CBA and then is selected as the most effective and reasonable RRM on the objects of this paper.
An auto sampling and filtering unit was developed for monitoring automation of a fermentation process and its performance was evaluated. The automatic sampling and filtering unit was constructed with a glass filter, a diaphragm suction pump, and a flow direction change valve. To evaluate operating stability, delivery volumes of the suction pump were measured according to the experimental conditions of cellulose powder, pore size of the glass filter and suction head of the pump. The developed unit could deliver the sample solution under any experimental conditions except the filter pore size of
After conducting QRA(quantitative risk assessment) for the high pressure urban gas pipelines planned to be installed, RMMs(risk mitigation measures) when the societal risk is outside the acceptable region have been derived in this paper. Also risk reduction rates are calculated for each RMM. As a result of QRA, we find out that damaged distance caused by radiational heat is largely dependent upon the wind velocity and the atmospheric stability. The measure that has the highest risk reduction effect is No. 10 which includes pipeline corrosion monitoring, MOV(motor operated valve) installation and the method to protect pipeline damage caused by third-party mechanical interference, and which shows 75 % of risk reduction effect.
Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.
Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.
Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70