• 제목/요약/키워드: Valve Monitoring

검색결과 129건 처리시간 0.029초

발전용 밸브누설 음향 진단 및 감시시스템 (Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현 (Valve monitoring system design and implementation using an infrared sensor and ZigBee)

  • 심현;오재철
    • 한국전자통신학회논문지
    • /
    • 제10권1호
    • /
    • pp.73-80
    • /
    • 2015
  • 화학공장과 같이 위험지역에 설치된 밸브장치는 폭발의 위험을 방지하기 위해 방화 방폭장치로 밀폐되어 있다. 본 논문에서는 방폭장치로 인해 외부전원장치를 사용할 수 없는 밸브장치에 적외선센서와 Zigbee 센서를 이용하여 위험지역의 밸브의 열림도를 측정하여 개폐여부를 확인하고, 밸브 개폐 작동시간을 로그화하여 운전 관리자가 공장을 관리 통제할 수 있는 저전력 모니터링 시스템을 제안한다. 전력관리기능을 적용하기 위해 개선된 비동기LPL 알고리즘을 적용한 전력제어 릴레이보드를 개발하고, 이를 적용한 방폭형 지능형 밸브시스템과 공장 밸브 개폐모니터링 시스템을 설계하고 이를 구현 및 테스트 하였다.

발전용 밸브누설 실시간 감시기술 연구 (Study on the Real-Time Leak Monitoring Technique for Power Plant Valves)

  • 이상국
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

체크밸브의 원격 상태감시 시스템 구현 (Realization of Remote Condition Monitoring System for Check Valve)

  • 이승연;전정섭;유준
    • 제어로봇시스템학회논문지
    • /
    • 제11권8호
    • /
    • pp.662-668
    • /
    • 2005
  • This paper presents a realization of check valve condition monitoring system based on fault diagnosis algorithm and Fieldbus communication. We first acquired AE(acoustic emission) sensor data at the check valve test loop, extract fault features through the teamed neural network, and send the processed data to a remote site. The overall system has been implemented and experimented results are given to show its effectiveness.

SVM을 이용한 버터플라이 밸브의 캐비테이션 상태감시 (Cavitation Condition Monitoring of Butterfly Valve Using Support Vector Machine)

  • 황원우;고명환;양보석
    • 한국소음진동공학회논문집
    • /
    • 제14권2호
    • /
    • pp.119-127
    • /
    • 2004
  • Butterfly valves are popularly used in service in the industrial and water works pipeline systems with large diameter because of its lightweight, simple structure and the rapidity of its manipulation. Sometimes cavitation can occur. resulting in noise, vibration and rapid deterioration of the valve trim, and do not allow further operation. Thus, the monitoring of cavitation is of economic interest and is very importance in industry. This paper proposes a condition monitoring scheme using statistical feature evaluation and support vector machine (SVM) to detect the cavitation conditions of butterfly valve which used as a flow control valve at the pumping stations. The stationary features of vibration signals are extracted from statistical moments. The SVMs are trained, and then classify normal and cavitation conditions of control valves. The SVMs with the reorganized feature vectors can distinguish the class of the untrained and untested data. The classification validity of this method is examined by various signals that are acquired from butterfly valves in the pumping stations and compared the classification success rate with those of self-organizing feature map neural network.

Guidelines for Transcatheter Aortic Valve Replacement in Korea: Past Obstacles and Future Perspectives

  • Choo, Suk Jung;Shinn, Sung Ho;Kim, Kyung Hwan;Kim, Wook Sung;Oh, Sam-Sae;Lee, Sak
    • Journal of Chest Surgery
    • /
    • 제51권4호
    • /
    • pp.231-240
    • /
    • 2018
  • Background: Analyses of the efficacy and safety of transcatheter aortic valve replacement (TAVR) in most countries have been based on outcomes obtained in accordance with national practice guidelines and monitoring protocols. The purpose of this study is to share our experience regarding the process for establishing guidelines and monitoring protocols for the use of TAVR in Korea, in the hopes that it may be helpful to others undergoing a similar process in their own country. Methods: The Korean guidelines for TAVR were established on June 1, 2015 in through a tri-party agreement involving the Department of Health and Welfare, the Korean Society of Thoracic and Cardiovascular Surgery and the Korean Society of Cardiology. We agreed to monitor the guidelines transparently and to exchange opinions regarding amendments or continuation of its contents after 3 years of monitoring. Results: The monitoring meetings were not held as regularly as agreed, and monitoring was also made difficult by insufficient and incomplete data. Nevertheless, during the meetings, measures to improve the monitoring process were discussed, and accordingly, an agreement was made to continue the monitoring process, with the aim of completing data collection by 2018. Conclusion: Compliance with guidelines is critical for assessing the efficacy and safety of TAVR. Moreover, the TAVR monitoring process must be properly conducted for an accurate evaluation to be made. Any country planning to introduce TAVR may encounter difficulties with regards to the optimal initiation strategy and subsequent monitoring. Nevertheless, continued efforts should be made to persuade the government and the corresponding medical societies to facilitate the optimal application of TAVR.

Condition Monitoring of Check Valve Using Neural Network

  • Lee, Seung-Youn;Jeon, Jeong-Seob;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2198-2202
    • /
    • 2005
  • In this paper we have presented a condition monitoring method of check valve using neural network. The acoustic emission sensor was used to acquire the condition signals of check valve in direct vessel injection (DVI) test loop. The acquired sensor signal pass through a signal conditioning which are consisted of steps; rejection of background noise, amplification, analogue to digital conversion, extract of feature points. The extracted feature points which represent the condition of check valve was utilized input values of fault diagnosis algorithms using pre-learned neural network. The fault diagnosis algorithm proceeds fault detection, fault isolation and fault identification within limited ranges. The developed algorithm enables timely diagnosis of failure of check valve’s degradation and service aging so that maintenance and replacement could be preformed prior to loss of the safety function. The overall process has been experimented and the results are given to show its effectiveness.

  • PDF

Development of Life Test Equipment with Real Time Monitoring System for Butterfly Valves

  • Lee, Gi-Chun;Choi, Byung-Oh;Lee, Young-Bum;Park, Jong-Won;Nam, Tae-Yeon;Song, Keun-Won
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권1호
    • /
    • pp.40-46
    • /
    • 2017
  • Small valves including ball valves, gate valves and butterfly valves have been adopted in the fields of steam power generation, petrochemical industry, carriers, and oil tankers. Butterfly valves have normally been applied to fields where in narrow places installing the existing valves such as gate valves and ball valves have proven difficult due to the surrounding area and the heavier of these valves. Butterfly valves are used to control the mass flow of the piping system under low pressure by rotating the circular disk installed inside. The butterfly valve is benefitted by having simpler structure in which the flow is controlled by rotating the disc circular plate along the center axis, whereas the weight of the valve is light compared to the gate valve and ball valve above-mentioned, as there is no additional bracket supporting the valve body. The manufacturing company needs to acquire the performance and life test equipment, in the case of adopting the improving factors to detect leakage and damage on the seat of the valve disc. However, small companies, which are manufacturing the industrial valves, normally sell their products without the life test, which is the reliability test and environment test, because of financial and manpower problems. Furthermore, the failure mode analysis of the products failed in the field is likewise problematic as there is no system collecting the failure data on sites for analyzing the failures of valves. The analyzing and researching process is not arranged systematically because of the financial problem. Therefore this study firstly tried to obtain information about the failure data from the sites, analyzed the failure mode based on the field data collected from the customers, and then obtained field data using measuring equipment. Secondly, we designed and manufactured the performance and life test equipment which also have the real time monitoring system with the naked eye for the butterfly valves. The concept of this equipment can also be adopted by other valves, such as the ball valve, gate valve, and various others. It can be applied to variously sized valves, ranging from 25 mm to large sized valves exceeding 3000 mm. Finally, this study carries out the life test with square wave pressure, using performance and life test equipment. The performance found out that the failures from the real time monitoring system were good. The results of this study can be expanded to the other valves like ball valves, gate valves, and control valves to find out the failure mode using the real time monitoring system for durability and performance tests.

AE 센서를 이용한 Check Valve 상태감시 시스템 구현 (Realization of Check Valve Condition Monitoring system using AE sensor)

  • 전정섭;이승연;백승문;유준;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.49-51
    • /
    • 2004
  • This paper presents a realization of fault detection algorithm and Fieldbus based communication for condition monitoring of check valve. We first acquired the AE(Acoustic Emission) sensor data at the KAERI check valve test loop, extract fault features through the learned Neural network, and send the processed data to a remote site. The overall system has been implemented and experimental results are given to show its effectiveness.

  • PDF

Check Valve 상태감시를 위한 통신 및 센서신호처리 기능 구현 (Realization of Communication and Sensor Signal Processing Technique for Condition Monitoring of Check Valve)

  • 전정섭;조재근;김정수;유준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.223-226
    • /
    • 2003
  • This paper presents a realization of sensor signal processing(noise filtering) and Fieldbus based communication for condition monitoring of check valve. we first acquired the AE(Acoustic Emission) sensor data at the KAERI check valve test loop, and their frequencies were analyzed to find the informative band. To reject background noises, bandpass filters have been designed. Also, to send the processed data to a remote site, wired communication facility has been realized via DeviceNet.

  • PDF