• 제목/요약/키워드: Valve Leakage

검색결과 283건 처리시간 0.024초

LPG 용기 밸브용 O-링의 누설안전성에 관한 해석적 연구 (Numerical Study on the Leakage Safety of O-rings for a LPG Cylinder Valve)

  • 김청균;김도현
    • 한국가스학회지
    • /
    • 제11권2호통권35호
    • /
    • pp.37-42
    • /
    • 2007
  • 본 논문에서는 밸브몸체와 밸브스템 사이의 사각그루브에 설치한 두 개의 O-링에 대한 누설 안전성을 해석한 결과를 제시하고 있다. O-링시일의 누설 안전성에 대한 해석은 압축률과 LPG 가스압력의 변동에 따라 발생되는 누설 안전성을 유한요소해석 프로그램 MARC로 계산하였다. FEM 해석결과에 따르면, LP가스 충전압력 $8kg/cm^2$에서 안전변의 안전한 작동압력 상한치 $24.8kg/cm^2$에 이르기까지 압력하중을 압력용기 안전기준에 의거 계산한 결과는 안전한 것으로 나타났다. 다만, 두 개의 O-링의 안전성을 충분하게 확보하기 위해서는 O-링소재의 시효경화 효과를 고려하는 것이 바람직하다.

  • PDF

Management of Recurrent Paravalvular Leakage in a Very High-Risk Patient: A Case Report

  • Park, Sung Jun;Kim, Young Woong;Yoo, Jae Suk;Kim, Joon Bum;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제48권1호
    • /
    • pp.59-62
    • /
    • 2015
  • Interventional device closure has emerged as a less invasive alternative to surgery in the management of paravalvular leakage. However, this procedure involves various problems such as a high probability of residual leakage or hemolysis. Here, we report a case of residual paravalvular leakage despite two attempts at interventional closure in a patient with a history of four previous mitral valve replacements. The fifth operation for the primary repair of paravalvular leakage was performed successfully. Careful evaluation before the procedure and specially designed devices are essential for the interventional treatment of paravalvular leakage. Surgery can be performed adequately in the management of paravalvular leakage even in high-risk patients.

판막치환술 후 심한 용혈 현상으로 재치환한 경험 (Severe Hemolysis after St. Jude Medical Valve Replacement in the Aortic Position -A Redo Case Report -)

  • 조영철
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.706-710
    • /
    • 1988
  • Intravascular hemolysis occurs in the majority of patient with mechanical valve prosthesis. The primary cause is mechanical trauma to red cells from turbulent blood flow through the prosthesis. Degree of hemolysis is dependent upon the type, size and material of valve and aggravated by paravalvular leakage. Clinically important hemolytic anemia is required medical management or consideration of reoperation. In severe hemolysis, reoperation is recommended without delay when seems to be renal failure. In this case, postoperative severe mechanical hemolysis was developed immediately after aortic valve replacement with St. Jude medical valve in a 13 year-old male patient. Neither significant paravalvular leakage nor valvular dysfunction was found through redo, but the mechanical valve was strongly suspected the cause of severe hemolysis. The St. Jude Medical valve was changed with Ionescu-Shiley bioprosthesis and any significant clinical problems were not noted through the postoperative course.

  • PDF

반도체 제조장비용 챔버 가스누출 방지를 위한 제어모듈 개발 (Controller for Gas Leakage Protection in Semiconductor Process Chamber)

  • 박성진;이의용;설용태
    • 한국산학기술학회논문지
    • /
    • 제6권5호
    • /
    • pp.373-377
    • /
    • 2005
  • 본 논문에서는 반도체 제조장비의 챔버 내부 가스누출을 방지하기위한 보완모듈을 제시하였다. MFC(mass flow controller) 다음단의 최종밸브와 챔버 사이의 가스관에 압력센서를 부착시켜, 압력센서의 신호와 최종밸브의 동작신호를 디지털 회로를 이용하여 실시간으로 감지하고 가스누출을 방지하도록 하였다. LED 모듈을 이용하여 공정중에 발생하는 2차 소성물로 인한 가스의 흐름과 관련된 시스템 고장을 표시한다. 본 연구에서 개발한 모듈을 이용하면 챔버 내에서의 가스누출로 인한 장비의 손상과 안전사고 등을 예방하는 효과가 있다.

  • PDF

산화제 개폐밸브 플랜지 기밀 해석 및 시험에 관한 연구 (Study on Leakage Analyses and Experimets on a Main Oxidizer shut-off Valve)

  • 유재한;홍문근;배영우;이수용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.251-253
    • /
    • 2010
  • 산화제 개폐밸브 개발 과정의 시험에서 금속 코니컬 씰이 장착된 밸브 중간 플랜지부에서 외부 누설이 발생하였다. 이에 기밀과 관련된 형상 변수인 볼트 수 및 플랜지 형상이 변경된 3가지 모델에 대하여 구조 해석을 수행하여, 설계 변경에 따른 무게 증가를 줄이고 동시에 플랜지간 벌어짐 양이 가장 적은 모델을 개선 모델로 선정하였다. 선정된 모델의 플랜지 부를 모사하는 시험 치구를 제작하여 기밀시험을 재수행하여 누설이 발생하지 않는 것은 확인하였으며, 결과적으로 플랜지 부의 기밀을 확보할 수 있는 설계 해석 방법을 검증하였다.

  • PDF

핵 밸브들의 인수 시험을 위한 누출량 시험(Ⅵ) (Leakage Testing for Acceptance Testing of Nuclear Valves (Ⅵ))

  • 주승환
    • 기술사
    • /
    • 제33권2호
    • /
    • pp.39-43
    • /
    • 2000
  • 여기서는 원자력발전소의 격납 용기에 달린 핵 밸브들을 인수 할 때, 적용될 누설시험을 해설한다. 시험할 핵 밸브들은 공급자가 제품을 제작하여 납품하기 이전에 제작사의 주관아래 실시되는 경우와, 발주자가 제품을 인수받고 난 후, 발주자의 주관으로 실시하는 경우가 있을 것이다. 경우가 어떻든 시험 절차는 다르지 않다. 이들에 관하여 자세한 시험 절차들을 소개한다.

  • PDF

IonescuShiley 조직판막 치환수술후 발생한 판막부전에 관한 임상적 연구 -7년간의 장기성적- (Valve Failure of the lonescu-Shiley Bovine Pericardial xenograft: 7 Year Follow - Up)

  • 함시영
    • Journal of Chest Surgery
    • /
    • 제20권1호
    • /
    • pp.55-69
    • /
    • 1987
  • The result of valve failure with the lonescu-Shiley pericardial xenograft was presented with the review of current knowledge. This study reviewed 557 patients, who underwent total of 683 lonescu-Shiley pericardial valve replacement from 1979 to 1985 at Seoul National University Hospital. There were 357 patients who had mitral valve replacement, 73 with aortic valve and 127 with double valve replacement. There were 35 operative deaths. The survivors were followed at OPD. There were 32 patients who had prosthetic valve failure, whose ages ranged from 11 to 58 years [mean 27.8] and their postop interval was 56 ~ 22 months [range; 6-87] The causes of valve failure are prosthetic valve endocarditis in 14, primary disruption or calcification in 13, paravalvular leakage in 4, and others in 2 patients. Redo valve replacement was done in 12 patients after a mean interval of 50 * 20 months. [range; 6-79 months] Actuarial analysis of late results indicates actuarial freedom from endocarditis at 6 year is 87.9 ~ 6.8%, and actuarial freedom from primary disruption or calcification or paravalvular leakage at 5 year is 84.4 * 2.3%. In this series, however, valve failure due to thrombosis is not included.

  • PDF

작은 인공판막주위 누출에 의한 용혈성 빈혈 (Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • 제29권4호
    • /
    • pp.444-448
    • /
    • 1996
  • 작은 인공판막주위 누출에 의한 용혈성 빈혈은 인공판막 치환술후올수 있는 합병증중의 하나이다. 경도의 용혈은 대개 기계 판막으로 대동맥 판막 치환술을 시행했을 때 생기 지만, 드물게는 승모판막 치환 술 후에 생 기도 더욱 드물게 조직판막 치환술 후에도 생 긴다 조직판막 치환술후에 용혈성 빈혈은 거의 생기지 않는다. lonescu-Shiley 심낭판막 치환술을 받은 환자에서 용혈성 빈혈은 승모판막에서는 없었고, 대동맥판막 에서 주로 발생하였다고 보고되 어 왔다. 41세 여자환자가 갑자기 진한적색뇨가생겨 본원에 입원하였다. 이 환자는 10년전 승모판막 폐쇄부전증으로 승모판막 치환술(lonescu-Shiley판막 27mm)을 받았던 병 력 이 있다. 심초음파검사상 판막을 통한 경도의 승모판막 폐쇄부전과 함께 판막의 비후가 관찰되었으나 판막주 위를 통해 세어나오는 판막주위 누출의 소견은 관찰할 수 없었다. 말초혈액도말검사상정적혈구성 정색소성 빈혈을 보였다. 혈액 및 요 검사에서 심한 용혈소견이 보였다. 51. Jude Medical 양엽 판막(size 27mm)으로 승모판막 치환술을 시행하였다. 수술시 lonescu-Shiley 판막에 판엽의 석 회화와 뒤틀림 ( istortion)이 있었고, 술자위 치 에서 1시 방향에 직경 5mm의 작은 판막주위 누출이 발견되었으며 이것이 용혈성 빈혈의 원인으로 생각되었다. 승모판 막 재치환술후 용혈소견은 완전히 사라졌다. 저자들은 작은 인공판막주위 누출에 의한 심한 용혈성 빈혈이 발생한 1예를 경험하였기에 문헌고찰 과 함께 보고하는 바이다.

  • PDF

산업용 표준의 압력시험 방법에 의한 고압 배관용 리테이너형 볼밸브의 구조해석에 관한 연구 (A Study on Structural Analysis of High-Pressure Pipeline Retainer-Type Ball Valve by Pressure Testing of the Industrial Standard)

  • 김철규;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제18권5호
    • /
    • pp.13-18
    • /
    • 2015
  • This study has been performed to evaluate the safety of the retainer-type ball valve for a high-pressure pipeline to a district heating plant. The retainer-type ball valve is an improved design for conventional ball valves, such as the floating ball valve and the trunnion ball valve. Numerical analysis of the valve design verification has been applied to investigate the safety factor and seat leakage of the DN300 and DN400 sizes. The given condition to solve the structural analysis was based on the international standard for ISO 5208. In this study, the methods for structural analysis are described in detail. The structural analysis results present the deformations, the equivalent stresses, and the safety factors. Through these results, this study successfully demonstrates the safety and seat leakage of the retainer-type ball valve. They also streamline the process of development for valve manufacturing.

T-50 항공기 유압조절 밸브 수명연장 방안 (A Study on Life Cycle Extension of T-50 Aircraft Hydraulic Control Valve)

  • 남용석;김태환;백승진;김승현;송석봉
    • 항공우주시스템공학회지
    • /
    • 제4권2호
    • /
    • pp.16-20
    • /
    • 2010
  • In General, the hydraulic system of T-50 Advanced Trainer is applied to flight control system, wheel & Brake system and fuel system for aircraft operation. The hydraulic system is operation with pressure of 3000psi. and many mechanical parts which is operated by hydraulic system has been stressed in incomplete environment same as heat and friction. for example, Oil leakage had occurred in the shutoff valve of FFP used in a certain period of time. After study, The crack progressed by fatigue due to the irregular hydraulic pressure and vibration has been identified as the reason of oil leakage. This paper presents life cycle extension plans of FFP shutoff valve by configuration improvements of shutoff valve and FFP hydraulic motor.

  • PDF