• Title/Summary/Keyword: Valid Time

Search Result 724, Processing Time 0.072 seconds

An Energy-Dissipation-Ratio Based Structural Health Monitoring System (에너지소산률을 이용한 구조물의 건전도 모니터링에 관한 연구)

  • Heo, Gwang-Hee;Shin, Heung-Chul;Shin, Jae-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.165-174
    • /
    • 2004
  • This research develops a technique which uses energy dissipation ratio in order to monitor the structural health on real time basis. For real-time monitoring, we employ the NExT and the ERA which enable us to obtain real-time data. Energy dissipation ratio is calculated from those data only with the damping and natural frequency of the structure, and from the calculated values we develop an algorithm (Energy dissipation method) which decides the damage degree of structure. The Energy dissipation method developed in this research is proved to be valid by comparison with other methods like the eigenparameter method and the MAC. Especially this method enables us to save measuring time and data which are the most important in real-time monitoring, and its use of the ambient vibration also makes it easy to monitor the whole structure and its damage points.

Virucidal Efficacy against Avian Influenza Virus of a Disinfectant Spray Containing Grapefruit Seed Extracts, Citric Acid, Malic Acid and Benzalkonium Chloride (자몽종자추출물, 구연산, 사과산 그리고 염화벤잘코늄을 주성분으로 하는 스프레이형 소독제의 조류인플루엔자바이러스에 대한 살바이러스 효과)

  • Cha, Chun-Nam;Park, Eun-Kee;Jung, Ji-Youn;Yoo, Chang-Yeol;Kim, Suk;Lee, Hu-Jang
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.4
    • /
    • pp.266-273
    • /
    • 2016
  • Objectives: This study evaluated the virucidal efficacy against avian influenza virus (AIV) of a disinfectant spray containing 0.25% grapefruit seed extract, 0.2% citric acid, 0.0625% malic acid and 0.0125% benzalkonium chloride. Methods: The disinfectant spray was diluted several times with hard water (HW) and organic matter (OM). Two point five mL of each diluent was added into each test tube, and 2.5 mL of AIV suspension was inserted into each test tube. After 30 minutes of virus-disinfectant contact reaction at $4^{\circ}C$, 2.5 mL of 10% inactivated fetal bovine serum was added into each test tube to neutralize the sanitizer efficacy. The neutralized solutions were serial 10-fold dilutions with phosphate buffer solution, and 0.2 mL of the diluents was injected into the allantoic cavity of five ten-day-old-chickens per dilution time. After incubation of the embryos for five days, the viability of the AIV was examined by hemagglutination titer. The valid dilution of the disinfectant spray was estimated according to the dilution time that the virus titer was inactivated more than $10^4$ 50% egg-infective dose (EID50)/mL compared with pathogen control. Results: In HW and OM conditions, the valid dilutions of the disinfectant spray against AIV were seven- and three-fold dilutions, respectively. The AIV titer of the pathogen control was more than 6.1 log10EID50/mL, and there was no embryonic toxicity. Conclusion: The present study showed that this disinfectant spray has effective virucidal activity against AIV.

Study on the Relations to Estimate Instrumental Seismic Intensities for the Moderate Earthquakes in South Korea (국내 중규모 지진에 대한 계측진도 추정식 연구)

  • Yun, Kwan-Hee;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.323-332
    • /
    • 2018
  • Recent two moderate earthquakes (2016 $M_w=5.4$ Gyeongju and 2017 $M_w=5.5$ Pohang) in Korea provided the unique chance of developing a set of relations to estimate instrumental seismic intensity in Korea by augmenting the time-history data from MMI seismic intensity regions above V to the insufficient data previously accumulated from the MMI regions limited up to IV. The MMI intensity regions of V and VI was identified by delineating the epicentral distance from the reference intensity statistics in distance derived by using the integrated MMI data obtained by combining the intensity survey results of KMA (Korea Meteorological Administration) and 'DYFI (Did You Feel It)' MMIs of USGS. The time-histories of the seismic stations from the MMI intensity regions above V were then preprocessed by applying the previously developed site-correction filters to be converted to a site-equivalent condition in a manner consistent with the previous study. The average values of the ground-motion parameters for the three ground motion parameters of PGA, PGV and BSPGA (Bracketed Summation of PGA per second for 30 seconds) were calculated for the MMI=V and VI and used to generate the dataset of the average values of the ground-motion parameters for the individual MMIs from I to VI. Based on this dataset, the linear regression analysis resulted in the following relations with proposed valid ranges of MMI. $MMI=2.36{\times}log_{10}(PGA(gal))+1.44$ ($I{\leq}MMI$$MMI=2.44{\times}log_{10}(PGV(kine))+4.86$ ($I{\leq}MMI$$MMI=2.59{\times}log_{10}(BSPGA(gal{\cdot}sec))-1.02$ ($I{\leq}MMI$

Testing for validity of isometric muscle endurance test as an abdominal muscular endurance evaluation methods (복근 지구력 평가 도구로서 등척성 수축 후 버티기 방법의 타당성 비교 검증)

  • Park, Soon-Tae;Hur, Sung-Hoon;Lee, Jang-Kyu;Lee, Jong-Sam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.815-827
    • /
    • 2014
  • The current study was undertaken to verify appropriateness of muscle endurance test at three different angles ($30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$) of isometric contraction position, and to sought valid and reliable testing method that provide an alternative to sit-ups. Total 92 young and healthy subjects (68 males and 24 females) were recruited, and the following results were obtained. 1. A low correlations in males, but a high correlations in females was found when the comparisons were made between aerobic and muscle endurance capability. 2. Measuring tolerance time, by using isometric contraction was showed a significant correlation with the repetition numbers of sit-ups. 3. The highest correlation was found at 40 inclined degrees of plane, and the lowest correlation was drawn from 50 inclined degrees of plane. Based on these results, it was concluded that measuring tolerance time during maintaining an isometric contraction at 40 inclined degrees of plane is a valid and effective tool for measuring abdominal muscle endurance, and it can be used as an alternative way of sit-up, which potentially risky for inducing many back-associated injuries. Further studies need to be undertaken to determine for optimal angles, that can safely be applied for people of various age groups and physical conditions.

Real-Time Shooting Area Analysis Algorithm of UAV Considering Three-Dimensional Topography (입체적 지형을 고려한 무인항공기의 실시간 촬영 영역 분석 알고리즘)

  • Park, Woo-Min;Choi, Jeong-Hun;Choi, Seong-Geun;Hwang, Nam-Du;Kim, Hwan-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1196-1206
    • /
    • 2013
  • In this paper, based on the information about navigation system of UAV with PTZ camera and 3D topography, algorithm able to show us in real-time UAV's geographical shooting location and automatically calculate superficial measure of the shooting area is proposed. And the method that can automatically estimate whether UAV is allowed to shoot a specific area is shown. In case of an UAV's shooting attempt at the specific area, obtainability of valid image depends on not only UAV's location but also information of 3D topography. As a result of the study, Ground Control Center will have real-time information about whether UAV can shoot the needed topography. Therefore, accurate remote flight control will be possible in real-time. Furthermore, the algorithm and the method of estimating shooting probability can be applied to pre-flight simulation and set of flight route.

An Application of Dirichlet Mixture Model for Failure Time Density Estimation to Components of Naval Combat System (디리슈레 혼합모형을 이용한 함정 전투체계 부품의 고장시간 분포 추정)

  • Lee, Jinwhan;Kim, Jung Hun;Jung, BongJoo;Kim, Kyeongtaek
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.4
    • /
    • pp.194-202
    • /
    • 2019
  • Reliability analysis of the components frequently starts with the data that manufacturer provides. If enough failure data are collected from the field operations, the reliability should be recomputed and updated on the basis of the field failure data. However, when the failure time record for a component contains only a few observations, all statistical methodologies are limited. In this case, where the failure records for multiple number of identical components are available, a valid alternative is combining all the data from each component into one data set with enough sample size and utilizing the useful information in the censored data. The ROK Navy has been operating multiple Patrol Killer Guided missiles (PKGs) for several years. The Korea Multi-Function Control Console (KMFCC) is one of key components in PKG combat system. The maintenance record for the KMFCC contains less than ten failure observations and a censored datum. This paper proposes a Bayesian approach with a Dirichlet mixture model to estimate failure time density for KMFCC. Trends test for each component record indicated that null hypothesis, that failure occurrence is renewal process, is not rejected. Since the KMFCCs have been functioning under different operating environment, the failure time distribution may be a composition of a number of unknown distributions, i.e. a mixture distribution, rather than a single distribution. The Dirichlet mixture model was coded as probabilistic programming in Python using PyMC3. Then Markov Chain Monte Carlo (MCMC) sampling technique employed in PyMC3 probabilistically estimated the parameters' posterior distribution through the Dirichlet mixture model. The simulation results revealed that the mixture models provide superior fits to the combined data set over single models.

Analysis of Problems of Water Supply Capacity Determination in Water Resources Systems (수자원시스템의 용수공급량 결정방법의 문제점 분석)

  • Lee, Gwang-Man;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.4
    • /
    • pp.331-342
    • /
    • 2014
  • In water resources planning, to decide proper water supply capacity is a very important task. Once water supply system such as a dam is decided, it will affect whole range of water resources circumstances for a long time. Even though systematic approaches have been implemented since 1980, many problems are still prevail in reality. Especially some issues related to the reliability analysis method used in planning dams in Korea have been persistently brought up. This study is to diagnose problems on the reliability criterion in water supply capacity assessment of water resources systems and discuss a valid method. As a result, the estimates by the different analysis time intervals, in case of the temporal reliability, show no large difference, but there is a large difference when assessment time intervals are differently applied. The volumetric reliability accounts for 2~3% higher than that of the temporal reliability, and resiliency and vulnerability also show large differences by the analysis time intervals.

Validation of Assessment for Mean Flow Field Using Spatial Averaging of Instantaneous ADCP Velocity Measurements (ADCP 자료의 공간평균을 이용한 평균유속장 산정에 대한 검증)

  • Kim, Dong-Su;Kang, Boo-Sik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.107-118
    • /
    • 2011
  • While the assessment of mean flow field is very important to characterize the hydrodynamic aspect of the flow regime in river, the conventional methodologies have required very time-consuming efforts and cost to obtain the mean flow field. The paper provides an efficient technique to quickly assess mean flow field by developing and applying spatial averaging method utilizing repeatedly surveyed acoustic Doppler current profiler(ADCP)'s cross-sectional measurements. ADCP has been widely used in measuring the detailed velocity and discharge in the last two decades. In order to validate the proposed spatial averaging method, the averaged velocity filed using the spatial averaging was compared with the bench-mark data computed by the time-averaging of the consistent fix-point ADCP measurement, which has been known as a valid but a bit inefficient way to obtain mean velocity field. The comparison showed a good agreement between two methods, which indicates that the spatial averaging method is able to be used as a surrogate way to assess the mean flow field. Bed shear stress distribution, which is a derived hydrodynamic quantity from the mean velocity field, was additionally computed by using both spatial and time-averaging methods, and they were compared each other so as to validate the spatial averaging method. This comparison also gave a good agreement. Therefore, such comparisons proved the validity of the spatial averaging to quickly assess mean flow field. The mean velocity field and its derived riverine quantities can be actively used for characterizing the flow dynamics as well as potentially applicable for validating numerical simulations.

A Cumulative Fair Service Model in Single Server (단일서버에서의 누적적 공정서비스 모델)

  • Lee Ju-Hyun;Park Kyeong-Ho;Hwang Ho-Young;Min Sang-Lyul
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.9
    • /
    • pp.585-591
    • /
    • 2006
  • Generalized Processor Sharing(GPS) model provides instantaneous fair services to currently backlogged sessions. Since this fair service distributes server capacity to backlogged sessions in proportion to their weights, the fairness is only valid between the sessions serviced at the same time. From the long time view, however, this fair service provides different server capacity with one session or another, even if these sessions have the same weights. This paper proposes a cumulative fair service(CFS) model to provide fair server capacity to all sessions in the long time view. This model provides fair service in session Viewpoint because it distributes server capacity in proportion to the weights of sessions. The model and an algorithm referencing that model are analyzed for their properties and performances. Performance evaluations verify that the proposed algorithm provides proportional service capacity to sessions in the long time view.

The Reliability and Validity of Figure-of-8 Walk Test in Patients with Stroke (뇌졸중 환자에서 Figure-of-8 walk test의 신뢰도와 타당도)

  • Kim, Yang-Ho;Lim, Jae-Heon
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • Purpose : The purpose of this study was to establish intra-rater, inter-rater, test-retest reliability, and concurrent validity of figure-of-8 walk test in people with stroke. Methods : The subjects of this study were 17 patients who were diagnosed with a stroke. Subjects were tested twice by the same raters, with 1 day between tests. Subjects were assessed by two physical therapists. Test-retest reliability was calculated using intraclass correlation coefficients (ICC). The concurrent validity was demonstrated by spearman correlation of F8WT with 10m walking test (10MWT), timed up and go test (TUG), Berg balance scale (BBS), dynamic gait index (DGI) and four square step test (FSST). Results : Intra-rater, inter-rater, test- retest of F8WT time, showed high reliability. Intra-rater, inter-rater, test-retest of F8WT steps demonstrated high reliability. Intra-rater, inter-rater, test-retest of F8WT total smoothness score showed below moderate reliability. There was a significant positive correlation of F8WT time with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT time with DGI, BBS. There was a significant positive correlation of F8WT steps with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT steps with DGI. There was a significant positive correlation of F8WT test total smoothness score with BBS. Conclusion : The time, and number of steps in F8WT show high inter, intra-rater, test-retest reliability. The F8WT smoothness shows below moderate reliability. The F8WT shows high concurrent validity with other comparable balance, and walking tests. The F8WT is a valid and reliable measure for assessing walking function in patients with a stroke.