• 제목/요약/키워드: Vacuum pressure difference

검색결과 100건 처리시간 0.024초

대기압/진공 조건의 트라이보 시험기를 이용한 박막 코팅의 마찰/마모 특성 비교 (Comparison of Friction and Wear Characteristics of Thin Film Coatings Using Tribotesters at Atmospheric/Vacuum Conditions)

  • 김해진;김대은;김창래
    • Tribology and Lubricants
    • /
    • 제35권6호
    • /
    • pp.389-395
    • /
    • 2019
  • In various industries, thin film coatings are used to improve friction and wear characteristics. Various types of tribotesters are used to evaluate the friction and wear characteristics of such thin film coatings. In this study, we fabricated a micro-tribotester and Tribo-scanning electron microscopy (SEM) to compare the friction and wear characteristics of copper (Cu) coatings under an atmospheric pressure and a vacuum condition, respectively. The reliability of the different types of tribotesters was evaluated by performing calibrations for the sensor to measure the friction forces and normal loads. Using the two different types of devices, the friction and wear tests are conducted at the same experimental conditions excluding environment conditions such as the atmospheric pressure and vacuum condition. The friction coefficient at the vacuum condition is lower than at the atmospheric pressure. This difference in friction characteristics is due to the fact that wear phenomena occur differently according to the atmospheric pressure and vacuum condition. At the atmospheric pressure, the abrasive wear is the main wear mechanism. At the vacuum condition, the adhesive wear is the main wear mechanism. The reason for the difference in the wear mechanism of the Cu coating at the atmospheric pressure and the vacuum condition is that the oxidation phenomenon, which does not appear at the vacuum condition, occurs at the atmospheric pressure; therefore, the characteristics of the Cu coating change accordingly.

음압 직각 다공질 공기베어링의 동특성에 관한 유한차분 해석 (Finite Difference Analysis of Dynamic Characteristics of Negative Pressure Rectangular Porous Gas Bearings)

  • 황평;콴폴리냐;이춘무;김은효
    • Tribology and Lubricants
    • /
    • 제22권2호
    • /
    • pp.93-98
    • /
    • 2006
  • The numerical analysis of the negative pressure porous gas bearings is presented. The pressure distribution is calculated using the finite difference method. The Reynolds equation and Darcy's equation are solved simultaneously. The air bearing stiffness and damping are evaluated using the perturbation method. Rectangular uniform grid is employed to model the bearing. The vacuum preloading is considered. The pressure in the vacuum pocket is assumed to be a constant negative pressure. The total load, stiffness, damping and flow rate are calculated fur several geometrical configurations and several values of negative pressure. It is found that too large vacuum pocket can result in negative total force.

진공 압력차이법에 의한 나노 정밀도를 가지는 폴리디메틸실록산 형상복제 (Fabrication Process of a Nano-precision Polydimethylsiloxane Replica using Vacuum Pressure-Difference Technique)

  • 박상후;임태우;양동열;공홍진;이광섭
    • 폴리머
    • /
    • 제28권4호
    • /
    • pp.305-313
    • /
    • 2004
  • 본 연구는 나노 복화공정을 이용하여 마이크로 혹은 나노공정에 응용이 가능한 형상모형 제작공정 개발과 폴리디메틸실록산 (polydimethylsiloxane)를 이용하여 만들어진 형상모형의 몰드로 나노급 정밀도의 폴리디메틸실록산 형상을 복제하는 공정에 관한 것이다. 본 연구에서 제안한 나노 복화공정은 복잡한 형상모형 (pattern)이나 2차원 형상을 CAD 파일 없이 비트맵 그림파일을 이용하여 직접적으로 200nm 정밀도를 가지는 형상으로 만들 수 있다. 형상모형은 펨토초 레이저를 이용하여 이광자 흡수 중합법으로 제작하기 때문에 형상의 정밀도는 레이저 범의 회절한계 이하로 얻을 수 있다. 이렇게 제작된 마스터 형상모형은 본 연구에서 제안한 진공압력차이법으로 폴리디메틸실록산 몰드를 제작하여 기존의 제작방법에 비하여 정밀한 제작이 가능함을 보였으며 또한 제작된 몰드를 이용하여 양각의 플리디메틸실록산 스탬프를 제작하였다.

Evaluation of Effectiveness of Vacuum Oral Cleaner Developed for Patients with Limited Mobility

  • Lee, Jae-Hyun;Jung, Ki-Won;Kim, Hee-Kyung;Koo, Ki-Tae;Kim, Sung-Hun
    • 대한치과의사협회지
    • /
    • 제54권12호
    • /
    • pp.1035-1044
    • /
    • 2016
  • Purpose : The purpose of this study was to compare the plaque removal effects of vacuum oral cleaner developed for the patients with limited mobility with those of manual toothbrushes and high pressure injection oral cleaner (dental water jet). Meterials and methods : Thirty human subjects were measured with Patient Hygiene Performance index (PHP index) and O'Leary index before and after the use of toothbrush, high pressure injection oral cleaner and vacuum oral cleaner. These three different oral hygiene methods were conducted with seven-day intermittence. Then the statistical analysis was carried out to define plaque removal rate of three different oral hygiene methods (${\alpha}=.05$). Results : According to the efficacy analysis of plaque removal before and after the oral cleaning using each of three methods, significant reduction in plaque after the treatment compared to the previous state when using toothbrush, high pressure injection oral cleaner, and vacuum oral cleaner was observed (P < 0.001). PHP index of tooth brushing was higher than that of the high pressure injection oral cleaner, while PHP index of vacuum oral cleaner did not show significant difference from either of the other two methods. There was no significance difference in O'Leary index among the three methods. Conclusion : Effect of plaque removal using the vacuum oral cleaner is comparable to that of manual tooth brush or high pressure injection oral cleaner, so it will be helpful for self-oral hygiene care of the patients with limited mobility.

  • PDF

Pressure Effect on Safranine Penetration in Some Hardwood Species

  • Chong, Song-Ho;Ahmed, Sheikh Ali;Park, Byung-Su;Chun, Su-Kyoung
    • 한국가구학회지
    • /
    • 제18권2호
    • /
    • pp.111-119
    • /
    • 2007
  • An experiment was conducted to know the safranine impregnation distance from surface to inward using 6 different hardwood species. During impregnation, 3 parameters were applied-vacuum, pressure and soaking time. Only vacuum treatment did not increase the permeability of wood. Vacuum followed by pressure increased the penetration depth of safranine in radial, tangential and longitudinal direction. Longitudinal penetration was found easy to impregnate. Comparing with radial and tangential direction, radial penetration was found easy. There was a striking difference among sapwood and heartwood permeability. Safranine input depth was found highest in diffused porous wood rather than in ring porous wood. At increased vacuum and pressure, safranine penetration was found easy.

  • PDF

Modeling and Control of an Electronic-Vacuum Booster for Vehicle Cruise Control

  • Lee, Chankyu;Kyongsu Yi
    • Journal of Mechanical Science and Technology
    • /
    • 제16권10호
    • /
    • pp.1314-1319
    • /
    • 2002
  • A mathematical model and control laws for an Electronic-Vacuum Booster (EVB) for application to vehicle cruise control will be presented. Also this paper includes performance test result of EVB and vehicle cruise control experiments. The pressure difference between the vacuum chamber and the apply chamber is controlled by a PWM-solenoid-valve. Since the pressure at the vacuum chamber is identical to that of the engine intake manifold, the output of the electronic-vacuum booster Is sensitive to engine speed. The performance characteristics of the electronic-vacuum booster have been investigated via computer simulations and vehicle tests. The mathematical model of the electronic-vacuum booster developed in this study and a two-state dynamic engine model have been used in the simulations. It has been shown by simulations and vehicle tests that the EVB-cruise control system can provide a vehicle with good distance control performance in both high speed and low speed stop and go driving situations.

FEM을 이용한 진공유리 패널의 지지대 설계변수 설정 (The Pillar Design Variable Determination up of the Vacuum Glazing Panel using FEM)

  • 김재경;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제10권4호
    • /
    • pp.101-106
    • /
    • 2011
  • There are various methods in the flat panel display manufacture. The cost reduction effect is very big in case of using the screen printing method. The screen printing method is much used in the process of forming PDP barrier and can apply to the process of arranging the pillars for maintaining the vacuum gap of the vacuum glazing panel. The pillar which is one of the core elements for comprising vacuum glazing maintains the vacuum gap overcoming the vacuum pressure difference with the atmospheric pressure generated in vacuum glazing. At the same time, the deformation phenomenon by vacuum pressure is relived. In this paper, by using FEM about three considered in the pillar design and arrangement kinds of limiting factors, the simulation was performed. The pillar optimum arrangement method at within the maximum allowable tensile stress and heat transfer coefficients according to the arrangement try to be presented based upon the analyzed result data review and this validity tries to be verified by FEM.

열음극 전리진공계 특성연구 (The study of hot cathode ionization vacuum gauges)

  • 홍승수;정광화;신용현;임종연;이상균
    • 한국진공학회지
    • /
    • 제7권4호
    • /
    • pp.277-284
    • /
    • 1998
  • 전달표준기(transfer gauge)로 사용되는 열음극 전리진공계의 교정을 위하여 초고진 공표준기의 압력비(pressure ratio), 오리피스 콘덕턴스, 그리고 porous plug 콘덕턴스 측정 에 대한 연구를 수행하였다. 이 표준기를 이용하여 제조회사가 다른 두 개의 전리진공계를 $7{times}10^{-7}$~$4{times}10^{-3}$ Pa압력구간에서 아르곤 가스를 사용하여 교정하였다. 그 결과 extractor 전 리진공계의 고진공과 초고진공 사이에서 압력에 따른 비직선성의 차이는 4%로 나타났고, stabil 전리진공계는 3%정도로 나타났다. Extractor 전리진공계의 경우 기체의 감도를 적절 히 조절해서 사용하면 진공계 자체 불확도인 10%이내의 오차범위에서 사용이 가능함을 알 수 있었다. 또한 stabil 전리진공계는 별도의 감도 조절하지 않고도 최대 4% 오차범위에서 사용이 가능함을 알 수 있었다.

  • PDF

초음속 디퓨져 시동 과정에 관한 수치 모사; 초기 진공도에 따른 디퓨져 내부 충격파 구조의 발달 과정 (Numerical simulation on starting transients in supersonic exhaust diffuser; evolution of internal shock structures with different initial cell pressures)

  • 박병훈;임지환;윤응섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.46-55
    • /
    • 2005
  • For the sea-level performance test of rocket motor designed to operate in the upper atmosphere, ejectors with no induced secondary flow are generally used, which serves dual purposes of evacuating the test cell and performing as a supersonic exhaust diffuser (SED). The main concern of this research is to simulate starting transients in order to visualize evolution of internal shock structures in SED with different initial cell (vacuum chamber) pressures. RANS code with low Reynolds $k-\varepsilon$ turbulence model was employed for these computations. Numerical results were compared with the pressure measurements previously performed [Proceedings of 2004 Annual Conference, KIMST], and showed good agreements with pressure-time history of measured data. In the case of low vacuum chamber pressure, abrupt impingement of the under-expanded supersonic jet from the nozzle onto the diffuser wall was observed, whereas initial impingement point was located downstream and moved slowly upstream in the case of non-vacuum chamber pressure. In spite of initially dissimilar evolution of shock structures, iso-mach contour revealed that the steady shock structures had little difference except the location of flow separation and normal shock.

  • PDF

Effect of membrane deformation on performance of vacuum assisted air gap membrane distillation (V-AGMD)

  • Kim, Yusik;Choi, Jihyeok;Choi, Yongjun;Lee, Sangho
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.51-62
    • /
    • 2022
  • Vacuum-assisted air gap membrane distillation (V-AGMD) has the potential to achieve higher flux and productivity than conventional air gap membrane distillation (AGMD). Nevertheless, there is not much information on technical aspects of V-AGMD operation. Accordingly, this study aims to analyze the effect of membrane deformation on flux in V-AGMD operation. Experiments were carried out using a bench-scale V-AGMD system. Statistical models were applied to understand the flux behaviors. Statistical models based on MLR, GNN, and MLFNN techniques were developed to describe the experimental data. Results showed that the flux increased by up to 4 times with the application of vacuum in V-AGMD compared with conventional AGMD. The flux in both AGMD and V-AGMD is affected by the difference between the air gap pressure and the saturation pressure of water vapor, but their dependences were different. In V-AGMD, the membranes were found to be deformed due to the vacuum pressure because they were not fully supported by the spacer. As a result, the deformation reduced the effective air gap width. Nevertheless, the rejection and LEP were not changed even if the deformation occurred. The flux behaviors in V-AGMD were successfully interpreted by the GNN and MLFNN models. According to the model calculations, the relative impact of the membrane deformation ranges from 10.3% to 16.1%.